40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 261 of 341  Not logged in ELOG logo
ID Date Author Type Category Subjectup Text Attachments
  15884   Tue Mar 9 10:57:06 2021 Paco, AnchalSummaryIMCXARM lock and POX spectra[Paco, Anchal]

- Upon arrival, MC is locked, and
we can see light in MON5 (PRM) (usually dark).
 20210309_POX11_Spec_XARMLocked.pdf20210309_XARM_Locked.tar.gz 
  11845   Thu Dec 3 19:10:28 2015 yutaroUpdateLSCXARM lock with ITMX actuated and related change on ASSTo avoid the strange kicking of ETMX, I
locked XARM with ITMX actuated instead of
ETMX so that I changed elements of C1LSC_OUTPUT_MTRX;
 40.png 
  11860   Mon Dec 7 15:56:35 2015 yutaroUpdateLSCXARM lock with ITMX actuated and related change on ASSI changed the snapshot file for ASS, /opt/rtcds/caltech/c1/scripts/ASS_DITHER_ON.snap
as follows:
  
  69   Tue Nov 6 15:36:03 2007 robUpdateLSCXARM lockedEasily, after resetting the PSL Uniblitz shutters.
 There's no entry from David or Andrey about
the recovery from last week's power outage,
  
  5804   Fri Nov 4 00:13:24 2011 KojiUpdateLSCXARM locked with POX11XARM lock was achieved by POX11_I
Summary:
- The  whitening gains of POX11_I
 POX11.pdf 
  12528   Mon Oct 3 21:24:02 2016 JohannesUpdateGeneralXARM loss measurement[gautam, johannes]

I started a script on Friday night
to collect some data for a reflection armloss
 ReflectionLoss.pdf 
  16975   Wed Jul 6 19:58:16 2022 PacoSummaryNoiseBudgetXARM noise budget[Anchal, Paco, Rana]

We locked the XARM
using POX11
 xarm_nb_2022_07.pdf 
  16945   Fri Jun 24 17:16:59 2022 PacoUpdateALSXAUX cable in control room[JC, Paco]

We took the long BNC cable that
ran from ETMX to ETMY and ran it from ETMX
  
  1704   Fri Jun 26 15:22:28 2009 ClaraUpdatePEMXLR cables tested and labeledWe now have two 80-foot, female-to-female
XLR cables for our pretty new microphones,
one yellow and one purple. They have been
 NC3FXX-EMC.pdfCat11_p35.pdf 
  12558   Thu Oct 13 14:49:57 2016 KojiConfigurationPEMXLR(F)-XLR(M) cable took from the fibox to the Blue microphone[Gautam Koji]

XLR(F)-XLR(M) cable for the blue
microphone is missing. Steve ordered one.
  
  7370   Mon Sep 10 18:42:33 2012 Jenne, Mike J.UpdateCamerasXY beam scan tomorrowWe tweaked the mirror on the AP table to
go through the center of the lens in order
to get a more circular beam, but it seemed
  
  8772   Thu Jun 27 19:17:03 2013 manasaUpdateLSCXarm ALS out-of-loop noiseMeasured
frequency noise is ~10Hz/rtHz @100Hz. 
 ALS_OoL.pdfALS_OoL1.pdf 
  10952   Wed Jan 28 23:53:24 2015 KojiSummaryASCXarm ASS fixX-Arm
ASS was fixed.
ASS_DITHER_ON.snap was updated so
 12.png 
  10974   Wed Feb 4 18:27:55 2015 KojiSummaryASCXarm ASS fixPlease remember
that Xarm ASS needs FM6 (Bounce filters)
  
  13032   Fri Jun 2 00:54:08 2017 KojiUpdateASSXarm ASS restoration workWhile Gautam is working the restoration
of Yarm ASS, I worked on Xarm.

Basically, I have changed the oscillator
 7x 
  10413   Wed Aug 20 04:09:21 2014 ericqUpdateGreen LockingXarm Green PDHI've made
a whole bunch of measurements on the Xarm
green situation.
TL;DRs:

 Xbodes.pdfXspectra.pdfscopeSweep.jpg 
  10415   Wed Aug 20 16:10:43 2014 ericqUpdateGreen LockingXarm Green PDHA MIST simulation tells me that the green
pdh horn-to-horn displacement is about 1.2nm,
or ~18kHz. I used this, along with the scope
 XspectraCombined.pdf 
  10417   Wed Aug 20 21:09:16 2014 ericqUpdateGreen LockingXarm Green PDHI remeasured all of the noise spectra again
today, making sure the input attenuation
was as low as it could safely be. I also
 scopeSweep.jpgXspectra.pdfYspectra.pdfXYcomp.pdf 
  10290   Tue Jul 29 20:14:08 2014 AndresUpdate40m Xend Table upgradeXarm Green steering mirror upgrade Xarm Green Steering Mirror Upgrade
Nick
and I did the upgrade for the green steering
mirror today. 
  
  10291   Tue Jul 29 20:14:10 2014 KojiUpdate40m Xend Table upgradeXarm Green steering mirror upgradeThat
was super fast! Great job, Andres and Nic!
  
  10422   Fri Aug 22 03:55:45 2014 JenneUpdateLSCXarm PDH fine, Yarm PDH/ALS needs work[Rana, Jenne, EricQ]
We did several things tonight. 
First, a list (so I can remember them all),
 Xend_ErrorPointMeasurements.pdfDARM_ALSdiff_vs_sqrtInv.pdf 
  10191   Sun Jul 13 17:06:35 2014 AndresUpdate40m Xend Table upgradeXarm Table Upgrade Calculation and Diagrams of possible new table layout Current Mode Matching
and Gouy Phase Between Steering Mirrors
 CurrentOpticalLayout.pngNewSetUp.PNGAlaModeSolutionplots.pngEntireScaleRangeAlaModeSolution.pngNewXarmOptimizationFromFaraday.m 
  8624   Thu May 23 01:27:11 2013 ManasaSummaryLSCXarm beat note search continuesTowards finding the x-arm beat note:

The green would not lock to a maximum
  
  8629   Thu May 23 13:14:34 2013 KojiSummaryLSCXarm beat note search continuesWe should consider to hook up the temperature
monitors of the NPROs to the ADCs.
  
  14424   Wed Jan 30 19:25:40 2019 gautamUpdateSUSXarm cavity alignmentSquishing cables at the ITMX satellite
box seems to have fixed the wandering ITM
that I observed yesterday - the sooner we
 Xarm.pngXarm_IR.png 
  1472   Fri Apr 10 19:10:53 2009 JenneUpdateGeneralXarm locked?I don't know who left the X arm locked,
but I just ran the Align Full IFO script,
so everything is good in case Yoichi/someone
  
  8203   Fri Mar 1 01:17:06 2013 JenneUpdateLSCXarm oscillationThere is an oscillation in the Xarm at
631Hz, which is not in the Yarm.  There
is a small peak in POY11_I at this frequency,
 POX11_630Hz_osc.pdf 
  8208   Fri Mar 1 16:58:37 2013 yutaUpdateLSCXarm oscillation stoppedPOX11 oscillation at 630 Hz was stopped
by installing 630 Hz resonant gain to LSC_XARM.
After few hours, oscillation stopped.
 POX11_630Hz.png 
  8210   Sat Mar 2 00:09:31 2013 ranaUpdateLSCXarm oscillation stopped  Don't use resonant gain - it
can lead to a loop instability since it makes
the loop have 3 UGFs.
  
  8297   Thu Mar 14 20:22:33 2013 JenneUpdateGreen LockingXbeat attemptI aligned the Xgreen and PSL green to overlap
on the X beat PD, and reconnected the splitter
which combines the X and Y beat signals and
  
  16194   Wed Jun 9 11:46:01 2021 Anchal, PacoSummaryAUXXend Green Laser PDH OLTF measurementWe measured the Xend green laser PDH Open
loop transfer function by following method:


We first measured the feedback
 image-6f2923a3-01ce-4d04-bc53-d8db0238e195.jpgimage-72223f4b-3b74-4574-a7ad-de6628a2c5e9.jpgX_Green_ARM_PDH_OLTF.pdf 
  16197   Thu Jun 10 14:01:36 2021 AnchalSummaryAUXXend Green Laser PDH OLTF measurement loop algebraAttachment 1 shows the closed loop of Xend
Green laser Arm PDH lock loop. Free running
laser noise gets injected at laser head after
 AUX_PDH_LOOP.pdf 
  16202   Tue Jun 15 15:26:43 2021 Anchal, PacoSummaryAUXXend Green Laser PDH OLTF measurement loop algebra, excitation at control pointAttachment 1 shows the case when excitation
is sent at control point i.e. the PZT output.
As before, free running laser noise 
 AuxPDHloop.pdf 
  16213   Fri Jun 18 10:07:23 2021 Anchal, PacoSummaryAUXXend Green Laser PDH OLTF with coherenceWe did the measurement of OLTF for Xend
green laser PDH loop with excitation added
at control point using a SR560 as shown in
 XEND_PDH_OLTF_with_Coherence.pdfBeta_Amp.pdf 
  8607   Tue May 21 18:18:23 2013 ManasaUpdateGreen LockingXend Green alignedX arm aligned to green.
Aligned the X arm to IR. 
Used steering mirrors to align the
  
  8610   Tue May 21 23:29:57 2013 ManasaUpdateGreen LockingXend Green alignedX-green and PSL green have been aligned
so that they interfere at the beat PD for
X. 
  
  16322   Mon Sep 13 15:14:36 2021 AnchalUpdateLSCXend Green laser injection mirrors M1 and M2 not responsiveI was showing some green laser locking
to Tega, I noticed that changing the PZT
sliders of M1/M2 angular position on Xend
  
  8569   Tue May 14 01:56:20 2013 JenneUpdateGreen LockingXend Green tweakedI locked the Xarm on green.  At the
PSL table, I adjusted the steering mirror
to get the beam centered on the GTRX DC PD. 
  
  8570   Tue May 14 02:19:13 2013 KojiUpdateGreen LockingXend Green tweakedNote that I'm supposed to return one of
the two green beat PDs and the power supply.
  
  9367   Tue Nov 12 16:49:22 2013 JenneUpdateLSCXend QPD and Whitening board pulled

    

       
            
 IMG_1262.JPGIMG_1260.JPGIMG_1264.JPGIMG_1276.JPG 
  9418   Wed Nov 20 17:05:15 2013 JenneUpdateLSCXend QPD and Whitening board replaced[EricQ, Jenne]
We have put the Xend QPD back in
place, and centered it.  The whitening
  
  9484   Wed Dec 18 00:26:15 2013 JenneUpdateLSCXend QPD schematic investigationI have looked at the photo of the Xend
QPD from elog
9367, as well as the schematic for the
  
  9486   Wed Dec 18 11:32:34 2013 ranaUpdateLSCXend QPD schematic investigation 
 Since we use the TransMon QPD
for triggering the high/low gain switching
  
  10794   Fri Dec 12 19:54:21 2014 JenneUpdateElectronicsXend QPD whitening board modifiedOkay, I have finished modifying the Xend
QPD whitening board, although I will likely
need to change the gain on Monday.
 QPDwhiteningModification_XtransCompleted_12Dec2014.pdfIMG_1779.JPGQPD_Xtrans_Ytrans_12Dec2014.pdfQPD_Xtrans_Ytrans_DarkVsLock_12Dec2014.pdf 
  10795   Sat Dec 13 00:35:11 2014 ranaUpdateElectronicsXend QPD whitening board modified 
 16 bit. There aren't any 14-bit
ADCs anywhere in LIGO. The aLIGO suspensions
  
  10774   Wed Dec 10 15:05:32 2014 JenneUpdateElectronicsXend QPD whitening board modified alreadyIn April, Koji logged that he had made
some changes to the Yend QPD whitening board
(elog
 IMG_1776.JPG 
  10782   Thu Dec 11 16:42:12 2014 JenneUpdateElectronicsXend QPD whitening board planHere is a little PDF of what I plan to
do to both of the transmission QPD whitening
boards later today.  The idea is to
 QPDwhiteningModification_11Dec2014.pdf 
  7180   Tue Aug 14 16:19:12 2012 JenneUpdateGreen LockingXend doubling crystal heater unplugged, repluggedI went down to the Xend table to look at
it to understand Steve's proposal, and I
noticed that the doubling crystal's heater's
  
  9025   Mon Aug 19 09:36:32 2013 KojiUpdateGreen LockingXend green aligned[Rana Koji]
This is an elog about the activity
on Friday night.
 ALS_OUTOFLOOP_130816.pdf 
  9031   Mon Aug 19 14:22:36 2013 ranaUpdateGreen LockingXend green aligned    
ELOG V3.1.3-