  639   Mon Jul 7 13:49:27 2008 YoichiHowToPSLMZ offset, gain tipsJohn, Yoichi

This morning John found that MZ servo is
  
  642   Mon Jul 7 16:30:08 2008 steveUpdatePSLPSL-PEM 16 days trendThis morning the laser head temp was up to
20.3C  because the laser chiller was overflowing.
I removed 700 cc water. 
 pempsl16d.jpg 
  645   Tue Jul 8 08:16:56 2008 steveUpdatePSLPMC problemThe PMC is unhappy. PMC auto locker is not
working.
DC output slider adjust has to be moved from
 pmc.jpg 
  648   Tue Jul 8 12:25:54 2008 JohnSummaryPSLISS gain set to 2dB    
  649   Tue Jul 8 21:46:38 2008 YoichiConfigurationPSLGC650M moved to the PMC transmissionI moved a GC650M, which was monitoring the
light coming out of the PSL, to the transmission
port of the PMC to see the transmitted mode
  
  659   Fri Jul 11 09:29:02 2008 steveUpdatePSLthe PMC still hangs upMorning alarms:

PMC high voltage is railing, it's auto locker
 pmc4d.jpg 
  662   Sat Jul 12 23:28:31 2008 ranaUpdatePSLPMC needs helpAs everyone has noticed recently, the PMC
seems to have a PZT problem. It often zooms
 Untitled.png 
  663   Sun Jul 13 17:19:29 2008 ranaSummaryPSLMOPA SLOWM CalibrationJohn, Rana

We first unlocked the FSS and ramped the
 SLOWDCcalibration.png 
  665   Mon Jul 14 00:36:19 2008 JohnSummaryPSLSlow sweep of laser temp - PMC PZT responseJohn, Rana

Follow up to # 663
 SlowTsweep.png 
  672   Tue Jul 15 10:24:57 2008 steveUpdatePSLPMC temp & pzt voltageThe PMC pzt HV was happy with no HEPA temp
stability.
Can we thermally insulate the pmc ?
 pmctemp.jpg 
  684   Wed Jul 16 17:36:51 2008 JohnDAQPSLFSS input offsetI changed the nominal FSS input offset to
0 from 0.3. Tolerance remains unchanged at
+/-0.05.
  
  688   Thu Jul 17 08:30:15 2008 steveUpdatePSLPMC relocked manuallyThe PMC pzt HV and the servo gain adj. are
railing at max this morning
 pmc4d.jpg 
  689   Thu Jul 17 12:15:21 2008 EricUpdatePSLSwept PMC PZT voltage rangeI unlocked the PMC and swept over C1:PSL-PMC_RAMP's
full range a couple of times this morning.
 The PMC should now be relocked and returned
  
  692   Thu Jul 17 20:13:34 2008 YoichiUpdatePSLPMC alignment/mode matching effortI'm working to improve the mode matching of
PMC.
Because I noticed that the beam was hitting
  
  699   Fri Jul 18 19:41:09 2008 YoichiUpdatePSLPMC PZT investigationI measured the HV coming to the PMC PZT by
plugging it off from the PZT and hooking
it up to a DVM.
 Hysteresis.pngStepResponse.png 
  701   Fri Jul 18 23:24:24 2008 robUpdatePSLPMC PZT investigation[quote]I measured the HV coming to the PMC
PZT by plugging it off from the PZT and hooking
it up to a DVM.
  
  702   Sat Jul 19 19:39:44 2008 robUpdatePSLPMC PZT investigation[quote][quote] The 64k is the series resistor
after the PA85, not the modeled resistance
of the PZT itself.[/quote]
  
  703   Sat Jul 19 19:41:56 2008 YoichiAoGPSLThe author of the entry 702 is Yoichi not RobI made a mistake.   
  711   Tue Jul 22 03:03:22 2008 John, RobUpdatePSLFSS open loop transfer functionWith the common gain slider maxed out the
unity gain frequency is 58kHz.
  
  712   Tue Jul 22 09:24:17 2008 steveUpdatePSLlaser powerLaser power reality of 120 days  power120d.jpg 
  713   Tue Jul 22 11:55:22 2008 ranaUpdatePSLNote from R. Abbott re: the PMCan email from Rich:
[CODE]Your PZT is broken.
  
  714   Tue Jul 22 13:15:14 2008 robUpdatePSLNote from R. Abbott re: the PMC[quote]an email from Rich:
[CODE]Your PZT is broken.
  
  715   Tue Jul 22 13:16:09 2008 John, RobUpdatePSLFSS open loop transfer function[quote]With the common gain slider maxed out
the unity gain frequency is 58kHz.
  
  719   Wed Jul 23 01:42:26 2008 ranaConfigurationPSLFSS RFPD: Examined, "repaired", and re-installed[U]Rob said that there might be something
wrong with the FSS RFPD since the loop gain
is so low.[/U]
 Untitled.pdf 
  726   Wed Jul 23 18:42:18 2008 JenneUpdatePSLAlignment of AOM[Rana, Yoichi, Jenne]

Short Version:  We are selecting the wrong
  
  735   Thu Jul 24 19:29:26 2008 YoichiConfigurationPSLC1:PSL-STAT_FSS_NOM_C_GAIN is changed from 30 to -0.7Koji, Yoichi

Since the light power going to the ref. cavity
  
  736   Thu Jul 24 21:04:58 2008 ranaUpdatePSLFSSSince Jenne and Yoichi are going to finish
up their refcav/FSS work in the morning I
decided to
  
  741   Fri Jul 25 19:57:18 2008 JenneUpdatePSLRef Cav & PMC"PMC is in, but is still being worked on.
 Leave it alone." ---Rana
  
  745   Sun Jul 27 23:06:17 2008 ranaUpdatePSLPMC, MZ, MC-MMT, etc.With the new PMC now in I aligned the MZ to
the new beam (there is sadly no steering
between the PMC and the MZ). 
  
  746   Mon Jul 28 11:20:13 2008 JenneUpdatePSLWork on the FSS and Reference Cavity[Yoichi, Jenne, Koji]

The Reference Cavity's saga continues....
  
  749   Mon Jul 28 17:44:07 2008 ranaUpdatePSLPMC PZT v. temperatureThis plot shows that the PMC [COLOR=darkblue]PZT
has ~20 Vpp fluctuations on a 24 hour timescale[/COLOR]
which is correlated to the 24 hour temperature
 Untitled.pdf 
  751   Mon Jul 28 23:41:07 2008 robConfigurationPSLFSS/MC gains twiddled
I found the FSS and MC gain settings in a
weird state.  The FSS was showing excess
  
  758   Tue Jul 29 19:41:38 2008 YoichiUpdatePSLFSS loop transfer functionsLast night I measured a bunch of transfer
functions on the FSS loop.
All the loop gains were measured with the
 7x 
  761   Tue Jul 29 23:04:34 2008 YoichiUpdatePSLFSS loop transfer functions[quote]
The measurement of the PZT open loop TF is
very suspicious. According to this, the PC
 OpltfPZTOnlyRaw.epsOpltfPZTOnly.eps 
  767   Wed Jul 30 13:09:40 2008 josephb, EricConfigurationPSLPMC scan experimentWe turned the PSL power down by a factor of
4, blocked one half of the Mach Zehnder and
scanned the PMC by applying a ramp signal
  
  772   Wed Jul 30 16:35:56 2008 EricUpdatePSLPMC Scan GraphsGraphs of the PMC scan data that I got earlier
today. 
 PMCLongScanPeak.tiffPMCLongScanWide.tiffPMCShortScanPeak.tiffPMCShortScanWide.tiff 
  775   Thu Jul 31 10:27:17 2008 ranaUpdatePSLPMC Scan Graphs[quote]Graphs of the PMC scan data that I
got earlier today. 
[/quote]
  
  778   Fri Aug 1 01:13:32 2008 ranaConfigurationPSLPSL Quad change and new scriptKoji and I changed a few optics so that now
~60% of the beam that went to the PSL POS
QPD
  
  781   Fri Aug 1 16:33:52 2008 ranaConfigurationPSLPSL Quad change and new scriptHere's the sensor ringdown trend from the
kick.
 Untitled.png 
  791   Mon Aug 4 13:43:02 2008 YoichiSummaryPSLFSS loop calibrationAs a part of the effort to repair the FSS
loop bandwidth, I tried to calibrate the
FSS loop.
 P7310048.JPGcavity-response.pdfcavity-response2.pdfcavity-gain.pdf 
  873   Sat Aug 23 09:39:51 2008 rana, jenneUpdatePSLPMC SurveyJenne, Rana

We scoped out the PMC situation yesterday.
  
  874   Mon Aug 25 10:07:35 2008 JenneUpdatePSLNumbers for the PMC servo board (Re: entry # 873)Jenne, Rana

These are the numbers that go along with
  
  876   Mon Aug 25 10:51:06 2008 steveUpdatePSLpsl headtemp is coming downThe laser water cooler was overflowing this
morning.
I removed 500 cc water from the chiller.
 ht4dw.jpg 
  878   Mon Aug 25 12:13:49 2008 JenneUpdatePSLBroken PMC Servo Board[SIZE=3]I broke the PMC servo board[/SIZE]
(on accident).
  
  879   Mon Aug 25 14:18:36 2008 JenneUpdatePSLPMC servo board is fixedThe PMC servo board is back in place, all
fixed up with a shiny new resistor.  The
PMC locks, and the MC locks (I'm not saying
  
  884   Tue Aug 26 09:04:59 2008 ranaConfigurationPSLPMC Servo Board: Out for RepairsI've started modifying our PMC board to bring
it up to the 21st century - [B][COLOR=blue]leave
the screen alone[/COLOR][/B] or else you
  
  892   Wed Aug 27 13:55:43 2008 rana,jenneUpdatePSLPMC Servo BoardBoard is back in. PMC is locked.

Nominal gain is now 15 dB with brick. We
  
  893   Thu Aug 28 18:56:14 2008 ranaConfigurationPSLbeam block distortedThere was a beam block after the Mach Zender.
Who or what put this there?
  
  895   Fri Aug 29 02:40:43 2008 rana,jenneUpdatePSLPMC Servo Board[quote]Board is back in. PMC is locked.
[/quote]
 pmclp-07.pdfpmclp_40m_080824.mpmclp.m 
  896   Fri Aug 29 10:20:32 2008 YoichiConfigurationPSLbeam block distorted[quote]There was a beam block after the Mach
Zender. Who or what put this there?
  
ELOG V3.1.3-