40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 258 of 341  Not logged in ELOG logo
ID Date Author Type Categorydown Subject Text Attachments
  6316   Fri Feb 24 18:59:04 2012 JenneUpdateComputersPyNDS and a Plot

    

       
            
  
  6341   Wed Feb 29 17:32:11 2012 MikeUpdateComputersPyNDS and a Plot


   
        
            
  
  6431   Tue Mar 20 17:50:44 2012 SureshUpdateComputersBeam Scan machine fixedThere was something wrong with the Beam
Scan PC.  The  mouse and screen
were not responding and the PC was asking
  
  6434   Wed Mar 21 19:12:27 2012 steveUpdateComputersAC power back on both ends

    

       
            
  
  6463   Wed Mar 28 21:15:53 2012 ranaOmnistructureComputersWireless router for GCI installed a NETGEAR Wireless Router (WPN824N)
today on the 131 network. The admin password
for it as well as the wireless access password
  
  6465   Thu Mar 29 13:23:05 2012 JenneOmnistructureComputersWireless router for GC

    

       
            
 IMG_0079.JPG 
  6467   Thu Mar 29 19:13:56 2012 JamieOmnistructureComputersWireless router for GCI retrieved the newly "secured"
router from Junaid.  It had apparently
been hooked up to the GC network via it's
  
  6479   Tue Apr 3 12:42:19 2012 Mike J.UpdateComputersHysteresis ModelHere's my first hysteresis model in Simulink.
It's based on the equation y=Amplitude*sin(frequency*t+phase)+(hysteresis/frequency2)
as a solution to y''+frequency2*y+hysteresis=0.
 hysteresis1.mdl 
  6485   Wed Apr 4 21:43:16 2012 Mike J.UpdateComputersBetter Hysteresis ModelA better hysteresis model based on the
simple harmonic oscillator equation. Useless
variables have been removed and output can
 SHO_hyst.png 
  6487   Thu Apr 5 01:07:08 2012 Mike J.UpdateComputersHysteresis PlotsHere are the hysteresis plots from the
most recent
model, which uses a modified harmonic
 SHO_hyst_plot.png 
  6494   Fri Apr 6 11:32:09 2012 JenneUpdateComputersRAID array is rebuilding....Suresh reported to Den, who reported to
me (although no elogs were made.....) that
something was funny with the FB.  I
  
  6495   Fri Apr 6 14:39:21 2012 JamieUpdateComputersRAID array is rebuilding....The RAID (JetStor SATA 416S) is indeed
resyncing itself after a disk failure. 
There is a hot spare, so it's stable for
  
  6498   Fri Apr 6 16:35:37 2012 DenUpdateComputersc1iooc1ioo computer can not connect to the framebuilder
and everything is red in the status for this
machine, C1:FEC-33_CPU_METER is not moving.
  
  6502   Fri Apr 6 20:24:31 2012 Mike J.UpdateComputersSensorayThe Sensoray device is currently viewing
Monitor 4 and plugged into Pianosa. 
The user interface is run at /home/controls/Downloads/sdk_2253_1.2.2_linux/python
  
  6503   Fri Apr 6 20:38:41 2012 Mike J.UpdateComputersSensoray Turns out that the "MPEG-4 VES"
video format is just bad for captured video. 
Everything except "MP4" and "MPEG-TS"
  
  6505   Sat Apr 7 01:45:02 2012 Mike J.UpdateComputersEven Better Hysteresis Model and Plots The new hysteresis model is slightly
based on the SHO equation, but with the force
being out of phase with the position by an
 hyst_v3.pnghyst_v_3.pnghyst_v_3-x(t).png 
  6507   Sat Apr 7 02:01:29 2012 Mike J.UpdateComputersProjector Cable ManagementI replaced the projector video and power
cables with longer ones, and zip-tied them
to the ceiling and wall so they don't block
 projector_cables.jpg 
  6513   Mon Apr 9 20:02:19 2012 Mike J.UpdateComputersSensorayThe highest resolution available is 720x480
pixels. Bit depth of captured images and
video is most likely 16 bits per pixel. Video
 out_0.jpg 
  6517   Tue Apr 10 23:56:44 2012 ranaUpdateComputersSensorayNow that Mike has got the Sensoray working,
Jenne/Suresh should grab some new images
of the ETM cage as Keiko did so that we can
  
  6518   Wed Apr 11 12:25:11 2012 RyanUpdateComputersUpdating aLIGO ConlogOver the next few days, I will be working
on upgrading the aLIGO Conlog install to
include new bugfixes distributed by Patrick
  
  6530   Thu Apr 12 22:04:17 2012 Mike J.UpdateComputersNew Hysteresis Model & PlotsThe new hysteresis model uses a triangle
wave with offset zero points as the position
function and a sinusoidal force function,
 hyst_combo.pngferro_hyst.png 
  6539   Tue Apr 17 10:55:50 2012 RyanUpdateComputersUpdating aLIGO Conlog

    

       
            
  
  6585   Mon Apr 30 18:46:34 2012 ranaUpdateComputersmegatronLast week I found that megatron was still
off after the power outage. Apparently, the
power recovery checklist had not been followed
  
  6592   Tue May 1 17:42:15 2012 Mike J.UpdateComputersSensorayI've upgraded the Sensoray GUI so it can
now switch the video channel it receives,
thanks to the videoswitch script.
 V4L2_Capture_Demo_r01.png 
  6645   Tue May 15 23:40:46 2012 Mike J.UpdateComputersImage SubtractionI acquired 2 raw frames of MC2 using "/users/mjenson/sensoray/sdk_2253_1.2.2_linux/capture
-n -s 720x480 -f 1", one while the
laser was off the mode cleaner and another
 mc2_1.bmpmc2_2.bmpmc2_1-mc2_2.bmp 
  6646   Wed May 16 11:53:45 2012 JenneUpdateComputersImage Subtraction

    

       
            
  
  6662   Tue May 22 20:24:06 2012 JamieUpdateComputersrossa is now running Ubuntu 10.04Now same as pianosa and rosalba. 
I'll upgrade allegra on Friday.
  
  6677   Thu May 24 16:13:05 2012 yutaUpdateComputersASS scripts on new ubuntu machines[Den, Yuta]

Background:
  
  6683   Fri May 25 16:58:54 2012 JamieConfigurationComputers.bashrc for workstationsI have setup a shared .bashrc for all the
workstations that is symlinked to the normal
location on all machines:
  
  6684   Fri May 25 17:50:38 2012 JamieUpdateComputersASS scripts on new ubuntu machines


   
        
            
  
  6685   Fri May 25 17:52:08 2012 JamieUpdateComputersallegra now running Ubuntu 10.04The last of the control room machines is
now upgraded.
  
  6703   Tue May 29 15:29:16 2012 JamieUpdateComputerslatest pynds installed on all new control room machinesThe DASWG lscsoft package repositories
have a lot of useful analysis software. 
It is all maintained for Debian "sqeeze",
  
  6722   Thu May 31 00:56:13 2012 JamieMetaphysicsComputersPlease remember to check in code changesI know it's really hard to remember, but
our future selves will thank us dearly if
we remember to commit all of our code changes
  
  6737   Fri Jun 1 02:33:40 2012 JenneUpdateComputersc1sus and c1iscex - bad fb connectionsSomething bad happened to c1sus and c1iscex
~20 min ago.  They both have "0x2bad"
's.  I restarted the daqd on the framebuilder,
  
  6738   Fri Jun 1 08:01:46 2012 steveUpdateComputersc1sus and c1iscex are down

    

       
            
 compdown.png 
  6740   Fri Jun 1 09:50:50 2012 JamieUpdateComputersc1sus and c1iscex - bad fb connections

    

       
            
  
  6742   Fri Jun 1 14:40:24 2012 JamieUpdateComputersc1sus and c1iscex - bad fb connections

    

       
            
  
  6761   Wed Jun 6 00:37:11 2012 JenneUpdateComputersmx_stream restarted on iscey, susJust as Yuta and I were sitting down to
look at our beatnote (really the output of
the freq discriminator) on Dataviewer, all
  
  6765   Wed Jun 6 14:17:56 2012 steveUpdateComputersiMac orderedRana, Steve,
 
  
  6772   Wed Jun 6 22:04:19 2012 JamieUpdateComputersFailed attempt to get pianosa to support dual monitorsI've spent an inordinate amount of time
trying to figure out how to get pianosa to
support dual monitors.  It apparently
  
  6773   Wed Jun 6 22:23:53 2012 JamieUpdateComputersFailed attempt to get pianosa to support dual monitorsI managed to get pianosa working again
with just a single monitor.  I'm done
trying to configure it for dual, though.
  
  6774   Wed Jun 6 22:25:05 2012 JamieUpdateComputerszita now running ubuntu 10.04I'll finish the rest of the config to turn
it into a full-fledged workstation tomorrow.
  
  6783   Thu Jun 7 10:39:21 2012 JamieUpdateComputerspianosa dual monitor workingI decided to remove what I thought was
the problematic extra nVidia video card,
since there are already two DVI outputs build-in. 
  
  6784   Thu Jun 7 12:49:50 2012 JamieUpdateComputerszita network configuredAdded zita to the martian host table, and
configured his network accordingly:

zita            A       192.168.113.217

  
  6795   Mon Jun 11 22:51:11 2012 JenneUpdateComputerstdsavg not workingtdsavg isn't working:
controls@rossa:/opt/rtcds/caltech/c1/scripts/LSC
6$ tdsavg 10 C1:LSC-ASDC_IN1
  
  6796   Tue Jun 12 00:15:51 2012 JenneUpdateComputersrtcds: command not foundWe can't compile any changes to the LSC
or the GCV models since Jamie's new script
/ program isn't found.  I don't know
  
  6797   Tue Jun 12 01:03:18 2012 JenneUpdateComputersmini boot festAs usual, we noticed the frame builder
wasn't connecting happily with the rest of
the computers just as we were about to lock
 stock-vector-wine-icon-on-computer-keyboard-original-illustration-58731781.jpg 
  6800   Tue Jun 12 02:09:43 2012 JenneUpdateComputersmini boot fest

    

       
            
  
  6801   Tue Jun 12 11:25:05 2012 JamieUpdateComputersrtcds: command not found

    

       
            
  
  6807   Tue Jun 12 17:46:09 2012 JenneUpdateComputersrtcds: command found

    

       
            
  
ELOG V3.1.3-