40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 258 of 344  Not logged in ELOG logo
ID Date Author Type Categoryup Subject Text Attachments
  13849   Wed May 16 21:02:22 2018 KevinUpdatePEMADC common mode rejection with new seismometer connectionsAs described in this
elog, the ADC for the seismometers now
has the signals wired directly to the ADC
 ADC_noise.pdf 
  13850   Wed May 16 21:47:17 2018 KevinUpdatePEMSeismometer Noise SpectraEarlier today Kira and I reconnected the
EX seismometer. I just took some spectra
of all three seismometers, shown in the attachments,
 BS_vel.pdfEX_vel.pdfEY_vel.pdf 
  13859   Thu May 17 15:38:19 2018 KiraUpdatePEMtest setup with seismometerI've moved my setup to the actual seismometer.
I attached the temperature sensor to the
seismometer (attachment 1) with duct tape,
 IMG_20180517_144420.jpgIMG_20180517_145754.jpgIMG_20180517_151956.jpgIMG_20180517_145121.jpg 
  13864   Fri May 18 14:33:34 2018 KiraUpdatePEMtest setup with seismometerHere is the result of my test. I think
I'll leave the can on over the weekend
because there's a long period of time
 seis_temp_can_on.png 
  13871   Mon May 21 10:15:35 2018 gautamUpdatePEMtest setup with seismometerI guess it's fine for now while we
are still finalizing the setup at EX, but
we should eventually line up the seismometer
  
  13872   Mon May 21 14:17:28 2018 KiraUpdatePEMtest setup with seismometerI have attached the graph for the seismometer
temperature fluctuations over 3 days. As
we can see, there is a noticeable fluctuation
 seis-temp.png 
  13877   Tue May 22 14:49:03 2018 KiraUpdatePEMtest setup with seismometerIt appears that one of the wires was disconnected
overnight or this morning so I wasn't
able to gather data over a full 24 hour period.
 seis-temp-2.png 
  13882   Wed May 23 14:50:33 2018 KiraUpdatePEMtest setup with seismometerThis time the test went without issue.
The first attachment is the data for the
past 24 hours and the second attachment is
 seis-temp-3.pngseis-temp-full-2.png 
  13887   Thu May 24 15:18:12 2018 KiraUpdatePEMPID loop restartedRana said that it wasn't necessary
to gather more data on the temperature fluctuations
so I have reconnected the heater circuit
  
  13888   Thu May 24 16:08:12 2018 KiraUpdatePEMparts listWe will need to order a few things for
our final setup.


1U box to place the heater
 front_panels.zip 
  13894   Tue May 29 16:22:43 2018 KiraUpdatePEMparts listI've updated the parts list to be an
excel document and included every single
part we will need. This is ony a first draft
 parts_list_-_Sheet1.pdf1U-panel-2.fpdEX-can-panel.fpd 
  13895   Tue May 29 16:33:04 2018 SteveUpdatePEMair cond filters replacedChris replaced some air condition filters
and ordered some replacement filter today.

  
  13899   Wed May 30 23:57:08 2018 gautamUpdatePEMBurning smell in office area / control room[koji, gautam]

We noticed quite a strong burning
smell in the office area and control room
  
  13903   Thu May 31 15:48:16 2018 KiraUpdatePEMrunning PID script with seismometerI have attached the result of running the
PID script on the seismometer with the can
on. The daily fluctuations are no more than
 can-on-pid.png 
  13922   Wed Jun 6 15:12:29 2018 KiraUpdatePEMparts from labGot this 1U box from the Y arm that we
could potentially use (attachment 1). It
doesn't have handles on the front but
 IMG_20180606_141149.jpgIMG_20180606_141851.jpgIMG_20180606_141912.jpg 
  13964   Thu Jun 14 15:24:32 2018 SteveUpdatePEM ADC DAC In Line Test Boards are inWe have 6 of these boards now in cabinet
E7

 ADC_DAC_in_(1).JPG 
  13979   Mon Jun 18 11:12:23 2018 KiraSummaryPEMfinishing up work at the labSince I am finishing my job at the lab,
I have stored all my electronics in a box
(attachment 1) and placed it under the table
 IMG_20180618_101640.jpgIMG_20180618_093920.jpgIMG_20180618_093932.jpg 
  13990   Wed Jun 20 09:16:56 2018 SteveUpdatePEMdusty labYou should wipe off the table cover before
you take it off next time.

It is important to turn up the
 AP.JPGITMY.JPGITMX.JPGSP.JPG 
  14001   Thu Jun 21 23:59:12 2018 shrutiUpdatePEMSeismometer temp controlWe (Rana and I) are re-assembling the temperature
controls on the seismometer to attempt PID
control and then improve it using reinforcement
  
  14016   Mon Jun 25 22:27:57 2018 shrutiUpdatePEMSeismometer temp control - heater circuitAfter removing all the clamping screws
from the heater circuit board, I soldered
the wire connecting IRF630 to the output
  
  14030   Thu Jun 28 11:05:48 2018 shrutiUpdatePEMSeismometer temp control equipmentEarlier today I cleared up most of the
equipment at the X end near the seismometer
to make the area walkable. 
  
  14113   Sun Jul 29 20:03:02 2018 ranaUpdatePEMSeismometer temp controlWhile Shruti is re-building Kira's
heater circuit, I looked up how to do one
of these (i.e. what does a real EE say about
 Screen_Shot_2018-07-29_at_8.00.27_PM.png 
  14185   Mon Aug 27 09:14:45 2018 SteveUpdatePEMsmall earth quakes Small earth quakes and suspensions. Which
one is the most free and most sensitive:
ITMX
 small_EQs_vs_SUSs.png 
  14186   Tue Aug 28 15:29:19 2018 SteveFrogsPEMRat is cutThe rat is cut by mechanical trap and it
was removed from ITMX south west location.

A nagy kover patkanyt a fogo elkapta
 rat#2.png.png 
  14266   Fri Nov 2 10:24:20 2018 SteveUpdatePEMroof cleaningPhysical plan is cleaning our roof and
gutters today.
  
  14321   Tue Nov 27 10:50:20 2018 SteveUpdatePEMearth quake MexicoNothing tripped.

 
 5.5M.Mexico.png 
  14323   Thu Nov 29 08:13:33 2018 SteveUpdatePEMEQ 3.9m So CAEQ did not trip anything. atm1

Just
a REMINDER:
our vacuum system is at atm to help the vacuum
 3.9mSoCA.pngVac_as_today.pngas_is.png 
  14949   Tue Oct 8 08:08:18 2019 gautamUpdatePEMPEM BLRMS anomalyYesterday, Koji and I noticed (from the
wall StripTool traces) that the vertex seismometer
RMS between 0.1-0.3 Hz in the X-direction
 PEManomaly.png 
  14989   Wed Oct 23 11:49:21 2019 gautamUpdatePEMPEM BLRMS anomalyI looked into the seismometer situation
a bit more today. Here is the story so far
- I think more investigation is required:
 seisAll_20191021.pdfspecGrams.zip 
  14992   Thu Oct 24 18:37:15 2019 gautamUpdatePEMT240 checkoutSummary:

The Trillium T240 seismometer
needs 
  
  15013   Tue Nov 5 12:37:50 2019 gautamUpdatePEMT240 interface unit pulled outI removed the Trillium T240 DAQ interface
unit from 1X4 for investigation.

It
 T240_recenter.pdfffPotential.pdf 
  15022   Wed Nov 13 19:34:45 2019 gautamUpdatePEMFollow-up on seismometer discussionAttachment
#1 shows the spectra
 seisAll_20191111.pdfffPotential.pdf 
  15023   Wed Nov 13 20:15:56 2019 ranaUpdatePEMFollow-up on seismometer discussionthis
is due to the Equivalence Principle: local
  
  15024   Wed Nov 13 23:40:15 2019 gautamUpdatePEMFollow-up on seismometer discussionHere is some disturbance
in the spacetime curvature, where the local
 seisAll_20191111_1Hz.pdf 
  15025   Thu Nov 14 12:11:04 2019 ranaUpdatePEMFollow-up on seismometer discussionat 1 Hz' this effect is not large so
that's real translation. at lower frequencies
a ground tilt couples to the horizontal sensors
  
  15027   Fri Nov 15 00:18:41 2019 ranaUpdatePEMFollow-up on seismometer discussionThe large ground motion at 1 Hz started
up again tonight at around 23:30. I walked
around the lab and nearby buildings with
 MCshake.pdf 
  15030   Fri Nov 15 12:16:48 2019 gautamUpdatePEMFollow-up on seismometer discussionAttachment
#1 is a spectrogram
 BS_ZspecGram.pdf.zip 
  15032   Mon Nov 18 14:32:53 2019 gautamUpdatePEMFollow-up on seismometer discussionThe nightly seismic activity enhancement
continued during the weekend. It always shows
up around 10pm local time, persists for ~1
  
  15036   Tue Nov 19 21:53:57 2019 gautamUpdatePEMFollow-up on seismometer discussionThe shaking started earlier today than
yesterday, at ~9pm local time.

While the IFO is shaking, I thought
 seisxSpec.pdf 
  15082   Fri Dec 6 17:49:46 2019 ranaSummaryPEMJump test of seismometers: EX needs recenteringYehonathan,  Seismometers.pdfsrc.tgz 
  15083   Sun Dec 8 20:15:41 2019 ranaSummaryPEMJump test of seismometers: EX needs recenteringI have re-centered the EX (and EY) seismometers.
They are Guralp CMG40-T, and have no special
centering procedure except cycling the power
 seis_all_191208.pdf 
  15086   Mon Dec 9 13:08:24 2019 YehonathanSummaryPEMJump test of seismometers: EX needs recenteringI check the seismometers in the last 14
hours (Attached). Seems like the coherenece
is restored in the x direction.
 seis_191208.pdf 
  15162   Tue Jan 28 08:26:53 2020 ranaFrogsPEMshakinghttps://breakthrough.caltech.edu/magazine/2019-aug/#article-Listening-with-Light

  
  15313   Fri Apr 24 00:26:59 2020 ranaSummaryPEML.A. EQ from Tuesday night   April22-EQ.pdf 
  15445   Wed Jul 1 12:50:40 2020 gautamUpdatePEMMC1 accelerometers plugged inI re-connected the 3 accelerometers located
near the MC1/MC3 chamber. It was a bit tedious
to get the cabling sorted - I estimate the
 IMG_8617.JPGIMG_8616.JPG 
  15634   Mon Oct 19 15:40:02 2020 KojiUpdatePEMAlaska EQ M7.5Alaska M7.5 20:54UTC https://earthquake.usgs.gov/earthquakes/eventpage/us6000c9hg/executive

I looked at the suspensions. The
  
  15642   Fri Oct 23 19:01:57 2020 KojiSummaryPEMPSL Particle Counter kit removed from the tableThe particle counter on the 40m PSL was
removed. The package was made together with
the OMC lab particle counter (see the packing
 P_20201022_173529.jpgP_20201022_173419.jpg 
  15863   Thu Mar 4 15:48:26 2021 KojiSummaryPEMWatchdog tripped, Optics damped backEQs seen on Summary pages
https://nodus.ligo.caltech.edu:30889/detcharsummary/day/20210304/pem/seismic_blrms/
  
  16214   Fri Jun 18 14:53:37 2021 AnchalSummaryPEMTemperature sensor network proposalI propose we set up a temperature sensor
network as described in attachment 1.

Here there are two types of units:
 40mTempSensors.pdf 
  16323   Mon Sep 13 17:05:04 2021 TegaSummaryPEMInfrasensing temperature sensor modbus configurationAnchal mentioned it would be good to put
more details about how I arrived at the values
needed to configure the modbus drive for
  
ELOG V3.1.3-