  10612   Wed Oct 15 19:56:38 2014 JenneUpdateLSCWhich side of optical spring are we on? Meas vs Model I have plotted measured data from
last night (elog
10607) with a version of the result from
 AntispringModel_NegOffsetMeas_comparison.pdfSpringModel_NegOffsetMeas_comparison.pdf 
  14759   Mon Jul 15 03:30:47 2019 KruthiUpdateCalibration-RepairWhite paper as a Lambertian scattererI made some rough measurements, using the
setup I had used for CCD calibration, to
get an idea of how good of a Lambertian scatterer
 BRDF_paper.png 
  15531   Mon Aug 17 23:36:10 2020 gautamUpdateALSWhitening and ALS noiseI finally managed to
install a differential-receiving whitening
board in 1Y2 - 4 channels are available at
 ALSimprovement.pdf 
  15533   Tue Aug 18 13:55:23 2020 ranaUpdateALSWhitening and ALS noiseNo, there should be no unscheduled visits
from any inspector, marshal, tech, or vendor.
They all have to be escorted or they don't
  
  15532   Mon Aug 17 23:41:50 2020 gautamUpdateBHDWhitening and air BHD dark noiseSummary:

With the chosen transimpedance
of 300 ohms, in order to be able to see the
 BHD_whitening.pdf 
  16972   Tue Jul 5 20:05:06 2022 TomislavUpdateElectronicsWhitening electronics noiseFor whitening electronics noise for WFS1,
I get (attachment). This doesn't seem
right, right?
 whitening_noises.png 
  13563   Sat Jan 20 01:20:37 2018 gautamUpdateElectronicsWhitening filter D990694We use D990694
in various places. Today, Rana alerted me
to an important consideration to be kept
 whiteningBoardLimitations.pdf 
  13564   Sat Jan 20 15:57:11 2018 ranaUpdateElectronicsWhitening filter D990694this
is the note from Hartmut Grote on this
topic from 2004
  
  13568   Tue Jan 23 01:33:23 2018 gautamUpdateElectronicsWhitening filter D990694After discussing with Koji, we looked at
the aLIGO
incarnation of this board. Interestingly,
  
  13572   Wed Jan 24 00:48:47 2018 gautamUpdateElectronicsWhitening filter D990694I plan to do some characterization of this
problem. The plan is to use THD
as a metric for whether we are having hidden
  
  3790   Tue Oct 26 22:57:37 2010 JenneConfigurationComputersWhy doesn't DTT work?!?DTT has only SUS and "X02" channels
under C1 in the drop down channel selection
menu.  Basically, we can't measure any
  
  3793   Wed Oct 27 10:53:03 2010 josephbConfigurationComputersWhy doesn't DTT work?!?Test points for the SUS channels should
be there.  They have been working previously
this week.  Possibly break down points
  
  4027   Wed Dec 8 14:46:19 2010 josephb, kiwamuUpdateCDSWhy the ETMX daq channels were not recorded last nightWhen adding
the ETMX DAQ channels using the daqconfig
gui (located in /opt/rtcds/caltech/c1/scripts/)
  
  14829   Mon Aug 5 17:23:26 2019 gautamSummaryComputersWiFi Settings on asiaThe VEA laptop asia was configured to be
able to connect to too many WiFi networks
- it was getting conflicted in its default
  
  13905   Thu May 31 19:51:06 2018 KojiUpdateGeneralWiFi router firmware update / rebootingThe model of our martian wifi router (NETGEAR
R6400) was found in the FBI router list to
be rebooted asociated with the malware "VPNFilter"
  
  2664   Tue Mar 9 09:32:31 2010 KojiSummaryGeneralWideband measurement of Fast PZT responseI have measured a wideband response
of the fast PZT in the LWE NPRO 700mW in
the Alberto's setup.
 PZT_response.png 
  1105   Sun Nov 2 20:44:58 2008 ranaUpdateASSWiener Filter performance over 5 hoursI took one 2 hour stretch of data to calculate
a MISO Wiener filter to subtract the Ranger
seismometer
 f.pngf1.png 
  1111   Mon Nov 3 22:35:40 2008 ranaUpdateASSWiener Filter performance over 5 hours[FONT=Comic Sans MS]To speed up the Wiener
filter work I defined a 256 Hz version of
the original 16kHz IOO-MC_L signal. The
 DAQ.pdf 
  1112   Tue Nov 4 00:47:53 2008 ranaUpdateASSWiener Filter performance over 5 hoursSame as before, but now with a working Ranger
seismometer.
 f2.pngf.png 
  5102   Wed Aug 3 02:28:08 2011 Manuel, IshwitaUpdateWienerFilteringWiener Filtering in X-armWiener Filtering was applied on the data
collected from the X-arm during the time:
GPS
 WFgur1X1Y2X2YN20000srate2048.pngWFgur2XN20000srate2048.pngWFgur2YN20000srate2048.pngSchermata-6.pngSchermata-7.png 
  854   Tue Aug 19 17:00:19 2008 SharonUpdate Wiener TF calibration - update[I]This is an update for post 814[/I]

I added the calibration gains I got for the
 m_per_m.png 
  6005   Fri Nov 25 12:46:13 2011 MirkoUpdateWienerFilteringWiener filtering tryoutTried the wiener filter with the TF from
p.5900
Tried it out with the TFs from p.5900:
 WienerFiltering.pdf 
  1337   Wed Feb 25 11:48:02 2009 JenneUpdatePEMWiener filtering update - work on filtering some S5 DARM_CTRL dataQuick update on my wiener filtering status:
Joe has been helping me get on the
GRID, so I now have  a grid certificate,
 h1_DARM_64s_4seis_25Feb09.pngh1_DARM_3600s_4seis_25Feb09.png 
  11366   Fri Jun 19 16:54:20 2015 JenneUpdateComputer Scripts / ProgramsWiener scripts in scripts directoryI have put the Wiener filter scripts into 
/opt/rtcds/caltech/c1/scripts/Wiener/ 
  
  4968   Thu Jul 14 17:34:35 2011 Ishwita, ManuelHowToWienerFilteringWiener-Hopf equationsSince we are using Wiener filtering in
our project, we studied the derivation of
Wiener-Hopf equations. Whatever we understood
 derivwf.pdf 
  16346   Mon Sep 20 15:23:08 2021 YehonathanUpdateComputersWifi internet fixedOver the weekend and today, the wifi was
acting bad with frequent disconnections and
no internet access. I tried to log into the
  
  16350   Mon Sep 20 21:56:07 2021 KojiUpdateComputersWifi internet fixedUg, factory resets... Caltech IMSS announced
that there was an intermittent network service
due to maintenance between Sept 19 and 20.
  
  2849   Tue Apr 27 11:16:13 2010 josephbConfigurationCDSWiki page with CDS .mdl names, shared memory allocationI've added a new page in the wiki which
describes the current naming scheme for the
.mdl model files used for the real time code
  
  11345   Wed Jun 3 17:04:08 2015 ericqUpdatePEMWilcoxon Accelerometer Huddle TestI've set up the Wilcoxon accelerometers
on the SP table for a huddle test, to estimate
their noise levels. 
 AccHuddle.jpg 
  11350   Wed Jun 10 02:50:39 2015 ericqUpdatePEMWilcoxon Accelerometer Huddle TestHere are some results for the 3-corner
hat subtraction for the six accelerometers,
from ~1 hour of data that didn't
 hats2Acc.png3hatcode.zip 
  11367   Sun Jun 21 13:21:03 2015 ranaUpdatePEMWilcoxon Accelerometer Huddle TestTo improve our sensor
noise estimate, the ACC cables should
be clamped using a rubber pad and a big dog
  
  11391   Sun Jul 5 18:14:13 2015 IgnacioUpdatePEMWilcoxon Accelerometer Huddle TestUpdated: On Thursday/Friday (sorry
for late elog) I was messing with Eric's
Wilcoxon 731A accelerometer huddle test data
 8x 
  9013   Thu Aug 15 09:34:12 2013 SteveUpdateGeneralWilcoxon cables rescuedEric and Steve,
 We removed Wilcoxon Accelerometer
PS and Amplifier unit under the BS optical
 rescuedGraycables.jpgwilconoxOut.jpgchanGains.jpg 
  2560   Tue Feb 2 15:30:03 2010 AlbertoFrogsTreasureWild OatsFYI. Sitting on the top shelf of George
I found an opened jar of raspberry jam and
an opened jar of creamy peanut butter. Both
  
  2373   Wed Dec 9 18:01:06 2009 KojiUpdateCOCWiping finished[Kiwamu, Jenne, Alberto, Steve, Bob,
Koji]
We
  
  1101   Thu Oct 30 11:07:25 2008 YoichiUpdateComputersWireless bridges arrivedFive wireless bridges for the GPIB-Ethernet
converters arrived.
One of them had a broken AC adapter. We have
  
  2347   Mon Nov 30 11:45:54 2009 JenneUpdateComputersWireless is backWhen Alberto was parting the Red Sea this
morning, and turning it green, he noticed
that the wireless had gone sketchy.
  
  1668   Thu Jun 11 14:54:18 2009 josephb, albertoUpdateComputersWireless networkAfter poking around for a few minutes several
facts became clear:
1) At least one GPIB interface has
  
  6463   Wed Mar 28 21:15:53 2012 ranaOmnistructureComputersWireless router for GCI installed a NETGEAR Wireless Router (WPN824N)
today on the 131 network. The admin password
for it as well as the wireless access password
  
  6465   Thu Mar 29 13:23:05 2012 JenneOmnistructureComputersWireless router for GC

    

       
            
 IMG_0079.JPG 
  6467   Thu Mar 29 19:13:56 2012 JamieOmnistructureComputersWireless router for GCI retrieved the newly "secured"
router from Junaid.  It had apparently
been hooked up to the GC network via it's
  
  12649   Wed Nov 30 11:56:56 2016 LydiaUpdateCDSWiring for Acromag auxex replacementI've attached a schematic for how we
will connect the Acromag mosules to the slow
channel I/O curently going to c1auxex. The
 auxex_acromag.pdf 
  14287   Fri Nov 9 22:24:22 2018 JonOmnistructure Wiring of Vacuum Acromag Chassis CompleteWiring of the power, Ethernet, and indicator
lights for the vacuum Acromag chassis is
complete. Even though this crate will only
 IMG_2987.jpgIMG_2985.jpgIMG_2986.jpg 
  4839   Mon Jun 20 11:04:03 2011 NicoleUpdateSUSWork Plan for Week 2Here is my work plan for this week:
Current Week Plan (Week 2)
  
  4416   Fri Mar 18 17:55:58 2011 SureshConfigurationGreen LockingWork Plan for Y-end Aux laser installationA rough
time-table and the various tasks are given
below: 
  
  3213   Wed Jul 14 10:00:14 2010 josephbUpdatePhase CameraWork near 1Y2 yesterdayRazib and I were attempting to get the
output of a photodiode (PD55A in this case)
recorded, so that we could independently
  
  3215   Wed Jul 14 11:51:48 2010 RazibUpdatePhase CameraWork near 1Y2 yesterday


   
        
            
  
  14773   Thu Jul 18 19:58:56 2019 gautamUpdateCDSWork on Acromag chassisNow that the .db files were prepared, I
wanted to test for errors. So I did the following:


Acromags were mounted on
 IMG_7771.JPGIMG_7770.JPGIMG_7772.JPG 
  746   Mon Jul 28 11:20:13 2008 JenneUpdatePSLWork on the FSS and Reference Cavity[Yoichi, Jenne, Koji]

The Reference Cavity's saga continues....
  
  10213   Wed Jul 16 01:54:25 2014 NichinUpdateGeneralWork plan for next week1) Debugging transimpedance calculations
in the PDFR