40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 257 of 341  Not logged in ELOG logo
IDup Date Author Type Category Subject Text Attachments
  12888   Tue Mar 14 15:05:18 2017 SteveUpdateOptical Levershistory of ETMX oplev laser 




 ETMX_1103P_3y.png 
  12889   Thu Mar 16 08:22:16 2017 SteveUpdateSUSETMX damping Finally I see what kicks the sus damping
off

 laser_power_glitch.png 
  12890   Fri Mar 17 10:47:16 2017 SteveUpdateOptical Levers ETMX oplev laser replacedJDSU 1103P. sn T8070866, made March 2007,
output power 2.7 mW,  on pd 17,750 counts,

GV
  
  12891   Fri Mar 17 14:49:09 2017 gautamUpdateLSCMCREFL condition picturesI did a quick measurement of the beam size
on the MC REFL PD today morning. I disabled
the MC autolocker while this measurement
 IMG_7219.JPGMCREFL_X.pdfMCREFL_Y.pdf 
  12892   Fri Mar 17 15:30:39 2017 SteveSummarySUSoplev laser summary updated   
     March  17, 
2017        
 oplev_sums.png 
  12893   Mon Mar 20 11:18:58 2017 gautamUpdateCDSNo internet connectivity on control room machinesThere
is no internet connectivity on any of the
  
  12894   Mon Mar 20 14:39:44 2017 gautamUpdateCDSNo internet connectivity on control room machinesKoji
diagnosed that the NAT router was to blame
  
  12895   Mon Mar 20 17:12:08 2017 steveUpdatePEMparticle counter inside of PSL enclousureThe logging script is multiplying by 100
instead of 10 !

 enclousure_partical_count.png 
  12896   Tue Mar 21 15:13:44 2017 gautamUpdateIMCIMC input beam mode matching[valera, gautam]

Last night, Valera and I looked
into two aspects of the IMC:
 IMG_7220.JPGIMC_ModeMatch.pdfsingleLensSensitivity.pdfsensitivity.pdfIMCmodeMatch.m 
  12897   Tue Mar 21 21:21:58 2017 gautamUpdateIOOWFS filter banks updatedThe arrangement of filters in the WFS loop
filter banks have been altered, Rana will
update with details of the motivation behind
 MCWFS_screen.png 
  12898   Tue Mar 21 21:59:48 2017 gautamUpdateIMCIMC input beam mode matching[valera, gautam]

We implemented the plan outlined
in the previous elog. The visibility (Pmax-Pmin)/(Pmax+Pmin) calculated
 IMG_3654.JPGIMG_3655.JPG 
  12899   Wed Mar 22 00:33:00 2017 gautamUpdateIMCIMC length offset nulling[valera, gautam]

Motivation: see this
elog
 offsetInvestigation.pdfoffset_summing_amp.pdf 
  12900   Wed Mar 22 16:58:25 2017 gautamUpdateIMCWFS sensing matrix measurementsI've taken a bunch of transfer function
measurements from the MC ASC PIT and YAW
channels to the WFS error signals using the
  
  12901   Thu Mar 23 01:44:53 2017 gautamUpdateIMCWFS sensing matrix measurementsThanks to Koji's nice MATLAB script
using DttData functions, I was able to quickly
analyze the TF data. Essentially, this measurement
 IMC_WFS_segment_TF.pdfIMC_WFS_channels_TF.pdfTFsummary.pdfIMC_WFS_170322.xlsx.zip 
  12902   Thu Mar 23 08:43:11 2017 ranaUpdateIMCWFS sensing matrix measurementsFor sensing matrix, better to use single
frequency sine response. We don't want
to measure around the bounce or above the
  
  12903   Thu Mar 23 23:38:58 2017 gautamUpdateIMCMC SUS damping gains stepped downI've reduced the gains of the damping
on all 3 MC SUS by a factor of 3 for overnight
observation as part of the ongoing feedforward
  
  12904   Fri Mar 24 11:26:57 2017 gautamUpdateIMCMC SUS damping gains restoredI've restored the damping loop gains
to their nominal values. Analysis of the
coherence between MCL and seismometer channels
  
  12905   Fri Mar 24 12:21:27 2017 gautamSummaryIOOMCL / MCF / CalibrationI repeated this measurement as follows:


Added a filter in the MC_F
filterbank (FM9) to account for the Pomona
 6x 
  12906   Fri Mar 24 19:04:18 2017 gautamUpdateIMCSeismic feedforward and WFS[valera, gautam]

On Wednesday at the meeting, we
were discussing why we aren't able to
 MCL_comparison.pdfseis_comparison.pdf 
  12907   Mon Mar 27 12:48:36 2017 ranaSummaryIOOMCL / MCF / CalibrationWhat readouts do we have for the PMC length?
If we could have a calibrated &
whitened error and control signal
  
  12908   Mon Mar 27 15:36:27 2017 SteveUpdatePEMparticle counter inside of PSL enclousure 




 HEPA_flow_effects.png 
  12909   Mon Mar 27 16:01:55 2017 SteveUpdatePEMX arm AC set to 68F 

The X arm air conditioner was not
regulating properly. The arm temp was warmer
  
  12910   Mon Mar 27 20:29:05 2017 ranaSummaryDetCharSummary pages broken againGoing to the summary pages and looking
at 'Today' seems to break it and
crash the browser. Other tabs are OK, but
  
  12911   Mon Mar 27 20:41:21 2017 rana, gautamUpdatePSLPMC DAQ assay for feed-forward integrationWe are thinking to use the PMC signals
to help us in figuring out the feedback /
feedforward stuff and making it better.
 TEK00000.PNG20170327_194931.jpg20170327_204554.jpg 
  12912   Mon Mar 27 22:40:44 2017 KojiSummaryIOOMCL / MCF / CalibrationIn http://nodus.ligo.caltech.edu:8080/40m/11793
I posted the calibrated PMC free-running
displcament with/without IMC locked. Unfortunately,
  
  12913   Tue Mar 28 16:47:40 2017 SteveUpdatesafetyProjector bulb is out againThree replacement
bulbs ordered

Rana can discribe
  
  12914   Tue Mar 28 21:06:53 2017 ranaSummaryCDS/cvs/cds/caltech/chans back on svn1.6Debian doesn't like EPICS. Or our XY
plots of beam spots...Sad!

 Screenshot-Untitled_Window.png 
  12915   Wed Mar 29 09:24:28 2017 SteveUpdateloresummery pagesThe summery pages are working at a slow
motion speed. It's response time 12 minutes.
  
  12916   Wed Mar 29 11:41:19 2017 gautamUpdatePSLPMC DAQ assay for feed-forward integrationThe C1IOO frontend machine that resides
in 1X1/1X2 has 2 ADCs, ADC0 and ADC1. The
latter has 28 out of 32 channels unused at
 C1ALS_PSLnamespace.pngPMCcheckout.pdfD980352-A-40m_151119.pdf 
  12917   Wed Mar 29 16:38:00 2017 SteveOmnistructureTreasuresus fiber illluminated   fiber.jpg 
  12918   Thu Mar 30 00:16:09 2017 gautamUpdatePSLPSL NPRO PZT calibrationAs part of the ongoing effort to try and
calibrate the PMC DAQ channels into physical
units, I tried to get a calibration for the
  
  12919   Thu Mar 30 10:41:56 2017 ranaOmnistructureTreasuresus fiber illluminatedVery, very cool!     
  12920   Thu Mar 30 18:11:01 2017 ranaUpdatePSLPMC DAQ assay for feed-forward integrationWhat you have drawn looks good to me: the
cut should be between TP3 and pin3 of the
AD620. This should maintain the DC coupled
  
  12921   Fri Mar 31 10:16:07 2017 SteveUpdatesafetylaser safety glasses annual inspectionLaser safety glasses cleaned in "
Dawn Ultra " mild soap - water solution
and measured for 1064 nm transmission at
 march2017.jpg2017march.jpg 
  12922   Fri Mar 31 16:10:33 2017 SteveUpdateTreasureLes Guthman Les Guthman interviews  gradstudent
Graig.

Main laser emergency shut off was
  
  12923   Sun Apr 2 23:14:30 2017 ranaUpdateComputer Scripts / Programsnodus update/upgrade/rebootI just did remote apt-get update, apt-get
upgrade, and then reboot on nodus. ELOG started
up by itself.
  
  12924   Mon Apr 3 17:09:47 2017 gautamUpdateCDSC1PSL burt-restoredWhen I came in this morning, Steve had
re-locked the PMC and IMC - but I could see
a ~1Hz intensity fluctuation on the PMC REFL video
  
  12925   Mon Apr 3 17:25:13 2017 gautamUpdatePSLPSL NPRO PZT calibrationSummary:

By sweeping the laser frequency
and looking at the PMC PDH error signal,
 PDHerr.pdfNPROcalib.pdf 
  12926   Mon Apr 3 23:07:09 2017 gautamUpdatePSLPMC DAQ assay for feed-forward integrationI made some changes to the DAQ path on
the PMC servo board, as per the plan posted
earlier in this thread. Summary of changes:
  
  12927   Tue Apr 4 11:24:21 2017 SteveUpdatesafetyProjector bulb is out againShipped out for repair.




  
  12928   Tue Apr 4 17:27:58 2017 ranaUpdatePSLPSL NPRO PZT calibrationgood cal. I wonder if this data also gives
us a good measurement of the cavity pole
or if the photo-thermal self-locking effect
  
  12929   Wed Apr 5 16:05:47 2017 gautamUpdateGeneralNB code checkout[evan, gautam]

We spent some time trying to get
the noise-budgeting code running today. I
  
  12930   Thu Apr 6 15:35:44 2017 SteveUpdatePEM envioirmental noiseBuilding:        
Central Engineering Services

     
  
  12931   Fri Apr 7 13:46:23 2017 SteveUpdateSUSETMX enclosure feedthoughETMX enclosure feedtrouh cabeling corrected.  bad.jpggood.jpg 
  12932   Mon Apr 10 09:49:32 2017 SteveUpdateOptical Leversoplev laser RIN test planningWe are planning to test 3 identical 1103Ps
RIN with  continous temp monitoring
and control later.
  
  12933   Mon Apr 10 09:58:35 2017 SteveSummarySUSoplev laser summary updated 




  
  12934   Mon Apr 10 14:21:57 2017 ranaUpdateOptical Leversoplev laser RIN test planningI'm suspicious of this temperature
sensor comparison. Usually, what they mean
by accuracy is not the same as what we mean.
  
  12935   Mon Apr 10 15:22:46 2017 ranaConfigurationWikiDokuWikis are back upAIC Wiki updated
to latest stable version of DokuWiki: 
  
  12936   Mon Apr 10 15:37:11 2017 gautamUpdateCOCRC folding mirrors - v3 of specs uploaded Koji and I have been going over these calculations
again before we send a list of revised requirements
to Ramin. I've uploaded v3 of the specs
 8x 
  12937   Mon Apr 10 16:00:26 2017 rebeccaUpdateCamerasPylon installation warningWhen trying to install an older version
of Pylon packaged for Debian that Joe B.
had sent, it gave the warning that the package
  
ELOG V3.1.3-