40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 256 of 344  Not logged in ELOG logo
ID Dateup Author Type Category Subject Text Attachments
  12838   Fri Feb 17 20:10:18 2017 gautamUpdateIMCWFS servos turned back on[Koji, gautam]

Turns
out the "problem" with WFS2 and
  
  12839   Sat Feb 18 14:09:06 2017 ranaUpdateIMCWFS servos turned back onYikes. Please change the all teh WFS
DQ channels sample rates from 2048 down to
512 Hz. I doubt we ever need anything about
  
  12840   Sat Feb 18 21:50:48 2017 gautamUpdateIMCWFS servos turned back onHere is a comparison  WFS_error_noise.pdf 
  12841   Tue Feb 21 10:08:35 2017 steveUpdatePEMnoisy morningOur new janitor Francisco is started working
in IFO room today.

 outside_activity.png 
  12842   Tue Feb 21 13:51:35 2017 CraigSummaryGeneralAlternative Calibration SchemeWe get SNR in two ways: the amplitude of
applied force and the integration time. 
So we are limited in two ways: stability
  
  12843   Tue Feb 21 17:05:14 2017 SteveUpdateGeneralProjector lamp replacedThis bulb was
blown out on Feb 4, 2017 after 2 months
of operation.
 blownup.jpg 
  12844   Wed Feb 22 08:54:17 2017 steveUpdatePEM PSL enclousure particle countETMX sus damping recovered.  PSL enclousure
is dusty at 20V rotation speed. Rainy days
as outside condition.
 dusty__PSL.png 
  12845   Wed Feb 22 10:16:54 2017 ranaSummaryGeneralAlternative Calibration SchemeOK, but the questions still stands: "   
  12846   Thu Feb 23 09:32:20 2017 KojiUpdateSUS wire standoffs updateKyle took high quality images of 
the three sapphire prisms using the microscope
@Downs. He analyzed the images to see the
 Sapphire_prism_1(A015).pngSapphire_prism_2(A016).pngSapphire_prism_3(A014).png 
  12847   Thu Feb 23 10:59:53 2017 gautamUpdateCOCRC folding mirrors - coating optimizationI've now made
 PR3_R_170222_2006.pdfPR3_123_TOnoise_170222_2203.pdfPR3_123_Layers_170222_2203.pdfPR3AR_R_170222_2258.pdfPR3AR_123_Layers_170222_2258.pdf 
  12848   Thu Feb 23 14:50:26 2017 SteveUpdateGeneral USB microscope returnedThe microscope shipped back to the vendor
for credit yesterday.

  
  12849   Thu Feb 23 15:48:43 2017 johannesUpdateComputersc1psl un-bootableUsing the PDA520 detector on the AS port
I tried to get some better estimates for
the round-trip loss in both arms. While setting
 scope_PDA520_ITM_aligned_ETM_misaligned.pngscope_PDA520_ITM_slightly_misaligned.pngpmc_trans_last10days.png 
  12850   Thu Feb 23 18:52:53 2017 ranaUpdateComputersc1psl un-bootableThe fringes seen on the oscope are mostly
likely due to the interference from multiple
light beams. If there are laser beams hitting
  
  12851   Thu Feb 23 19:44:48 2017 johannesUpdateComputersc1psl un-bootableYes, that was one of the things that I
wanted to look into. One thing Gautam and
I did that I didn't mention was to reconnect
 slow_startup_logs.tar.gz 
  12852   Fri Feb 24 20:38:01 2017 johannesUpdateComputersc1psl boot-stall culprit identified[Gautam, Johannes]

c1psl finally booted up again,
PMC and IMC are locked.
  
  12853   Mon Feb 27 15:33:10 2017 SteveUpdateVACRGA scan at day 130Valve configuration: vacuum normal

Vacuum envelope: 23.5 C

RGA head: 46.6 C
 rgascan@130d.png 
  12854   Tue Feb 28 01:28:52 2017 johannesUpdateComputersc1psl un-bootableIt turned out the 'ringing' was
caused by the respective other ETM still
being aligned. For these reflection measurements
  
  12855   Tue Feb 28 08:04:48 2017 steveUpdatePEMETMX damping recoveredETMX sus damping recovered.

Note: The giant metal garbage container
was moved from the south west corner of CES
 ETMX.png 
  12856   Tue Feb 28 18:25:22 2017 ranaUpdatePEMETMX damping recoveredHuh? So should we ask them to put the container
back? Or do you have some other theory about
ETMX tripping that is not garbage related?
  
  12857   Tue Feb 28 21:05:44 2017 ranaSummaryIOOMC Length offset changes MCWFS offsetsThe input offset on the MC length servo
board changes the lock point of the length
loop (by how much? need to calibrate this
  
  12858   Wed Mar 1 08:28:04 2017 SteveUpdateOptical Leversoplev laser RINGautam and Steve,

New JDSU 1103P HeNe oplev laser
RIN was measured on the SP table with cover
 RIN_1103P.pngRIN_HeNe.png 
  12859   Wed Mar 1 16:00:41 2017 gautamUpdateComputer Scripts / ProgramsMatlab R2016b installedSince it would be nice to have the latest
version of Matlab, with all its swanky new
features (?), available on the control room
  
  12860   Wed Mar 1 17:25:28 2017 SteveUpdateLSCMCREFL condition picturesGautam and Steve,

 

Our MCREFL rfpd
 IMG_3646.JPGmcRefl_1.jpgmcRefl_3.jpgmcRefl_5.jpg 
  12861   Wed Mar 1 21:15:40 2017 LydiaUpdateIMCFront panel for 29.5 MHz amplifier box
I installed the front panel today.
While I had the box out I also replaced
 RF_amp_(1).pdf 
  12862   Wed Mar 1 23:56:09 2017 gautamUpdateIMCFront panel for 29.5 MHz amplifier boxThe
alignment wasn't disturbed for the photo-taking
- I just re-checked that the spot is indeed
  
  12863   Thu Mar 2 13:59:04 2017 SteveUpdateOptical Leversoplev laser RINThe laser got much better at low frequency
as it warmed up. This laser is almost as
good as the electronics?
 1103P@2d.png 
  12864   Thu Mar 2 17:58:45 2017 ranaUpdateOptical Leversoplev laser RINThis measurement looks bogus - the difference
between dark and not dark is not significant
enough to believe. Need to figure out how
  
  12865   Thu Mar 2 20:32:18 2017 LydiaUpdateIMCFront panel for 29.5 MHz amplifier box[gautam, lydia]

I pulled out the box and found
the problem: the +24 V input to the amplifier
  
  12866   Fri Mar 3 17:24:21 2017 SteveUpdateOptical Leversoplev laser RINCorrected oplev laser RIN plot at
day 3

RXA:
 3march17.pdf 
  12867   Sun Mar 5 12:41:23 2017 gautamUpdateIMCWFS servo-steppinI've been sitting on some data for
a while now which I finally got around to
plotting. Here is a quick summary:
 WFS_stepping.pngWFS_comparisons.pdfWFSdigitalAA.pdf 
  12868   Mon Mar 6 09:12:59 2017 SteveUpdatesafety crane inspection 2017All 3 cranes inspected by professional
Fred Goodbar of Konecranes and load tested
with 450 lbs at max reach on Friday, March
 inspection_2017.jpg 
  12869   Mon Mar 6 12:34:30 2017 johannesSummaryASSASS light injection scenariosWhat we want from the light source for
the AS port light injection:


Frequency control for locking
  
  12870   Mon Mar 6 14:47:49 2017 gautamUpdateSummary PagesCode status check script modifiedFor a few days now, the "code status"
page
has been telling us that the summary pages
  
  12871   Mon Mar 6 16:32:36 2017 SteveUpdateGeneralold NPRO 16 years old Lightwave NPRO M126-1064-700,
sn 415 power output is tripping continously
to zero.
  
  12872   Tue Mar 7 15:17:19 2017 SteveBureaucracyGeneralproperty tagProperty tag found.  property_tag.jpg 
  12873   Wed Mar 8 15:28:37 2017 SteveUpdateOptical Leversoplev laser RINGautam and Steve,




 RIN.jpgRIN_1103P_rotated.pdf 
  12874   Wed Mar 8 18:18:51 2017 johannesUpdateComputer Scripts / Programsloss scriptI started a loss script on Donatella that
will scan the beam spot across ETMY, recording
the reflected power from the arm via the
  
  12875   Thu Mar 9 15:25:12 2017 KojiUpdateGeneralIMC/XYarms aligned/lockedAs per Steve's request, I've checked
the alignment of the IMC and the arms. These
three cavities are locked and aligned.
  
  12876   Thu Mar 9 17:26:43 2017 SteveUpdateGeneralattempted ETMY picture takingI removed the video monitoring can and
replaced it with Olympus SP-570UZ camera.
It has no IR blocker. The OSEM light are
  
  12877   Thu Mar 9 20:11:04 2017 KojiUpdateGeneralattempted ETMY picture takingThe attached is the ETMY image with the
single arm locked. This was the best I could
do. Here is the recipe
 P3090032.JPG 
  12878   Thu Mar 9 20:38:19 2017 ranaConfigurationIOOMC lock acquisition settings changed; no more HOM locksThe MC was sort of misaligned. It was locking
on some vertical HOMs. So I locked it and
aligned the suspensions to the input beam
  
  12879   Thu Mar 9 22:28:11 2017 johannesUpdateComputer Scripts / Programsloss scriptloss map script running on Rossa that moves
the beam on ETMX. Yarm was misaligned for
this, most recent PIT and YAW settings were
  
  12880   Fri Mar 10 11:37:25 2017 gautamUpdateComputer Scripts / Programsloss scriptThis was still running at ~9.30am today
morning, at which point I manually terminated
it after confirming with Johannes that it
  
  12881   Fri Mar 10 18:00:22 2017 SteveUpdateGeneralattempted ETMY picture takingYour technique works Koji  P3100044.JPGP3090024.JPG 
  12882   Fri Mar 10 19:48:56 2017 johannesUpdateComputer Scripts / Programsloss scriptLoss script running again, on Pianosa this
time. Due to an oversight in the code the
beam wasn't actually moved across ETMY
  
  12883   Sat Mar 11 20:11:58 2017 johannesUpdateComputer Scripts / Programsloss scriptYarm script running on Pianosa. Still working
on visualization of the ETMX lossmap.

  
  12884   Mon Mar 13 16:47:41 2017 SteveUpdatePEMY-arm air conditon belts replacedThe east end AC unit is arching over and
running rough at CES. Called for mechanic.......

Both belts were replaced and the
  
  12885   Tue Mar 14 09:08:11 2017 SteveUpdateOptical LeversETMX HeNe is deadETMX oplev laser is dead. It will be replaced
this after noon. Sus damping recovered.
 this_morning.png 
  12886   Tue Mar 14 10:40:30 2017 SteveUpdateSUSOSEM filters are inWe have 50 pieces in the clean cabinet.  filters.jpg 
  12887   Tue Mar 14 10:56:33 2017 gautamUpdateCOCRC folding mirrors - coating optimizationRana suggested including some additional
terms to the cost function to penalize high
sensitivity to deviations in the layer thickness
 PR3_R_170313_1701.pdfPR3AR_123_Layers_170313_1701.pdfPR3AR_R_170313_1752.pdfPR3AR_123_Layers_170313_1752.pdf 
ELOG V3.1.3-