  12687   Thu Dec 29 10:24:56 2016 SteveUpdatePEMEQ5.7mHawthorn NVSus damping restored.

 
 eq5.7HawthorneNV.png 
  12696   Mon Jan 9 09:18:47 2017 SteveUpdatePEMpower glitchThere was a power glitch last night around
1:15am

The vacuum was not effected.
 MondayMorning.png 
  12711   Fri Jan 13 10:53:03 2017 SteveUpdatePEMdoors are fixedControl room to outside door was
realigned. 

  
  12712   Fri Jan 13 14:18:28 2017 SteveUpdatePEMair condition fixedThe old control room AC  has been
stick in heating mode for
about 2 months. It's thermostate
 PEM_120d.png 
  12743   Fri Jan 20 14:42:12 2017 SteveUpdatePEMCaltech weather stationWe should be able to connect to this station   
  12744   Fri Jan 20 17:12:37 2017 SteveUpdatePEMEM172 mic is hooked up in the PSLGautam and Steve,

It is hanging in the midle of the
PSL enclosure. Wired to 1X1 to get plus and
 EM172c.jpg 
  12789   Thu Feb 2 17:34:25 2017 ranaUpdatePEMEM172 mic is hooked up in the PSLI don't know if anyone looked at the
time series (not trend) or spectrum of the
Microphone after installation, but it looks
 MicFail.pdf 
  12790   Thu Feb 2 17:43:20 2017 gautamUpdatePEMEM172 mic is hooked up in the PSLI had noticed something wonky with the
microphone, but neglected to elog it. I had
tested it after installation by playing a
 Mic_broken.png 
  12836   Fri Feb 17 10:56:12 2017 steveUpdatePEMparticle counter moved into PSL enclousureThe MET#1 particle counter was moved from
CES wall at ITMX to PSL enclousure south
west corner at 11am.
 from_here.jpgto_here.jpgPSL_particles.png 
  12841   Tue Feb 21 10:08:35 2017 steveUpdatePEMnoisy morningOur new janitor Francisco is started working
in IFO room today.

 outside_activity.png 
  12844   Wed Feb 22 08:54:17 2017 steveUpdatePEM PSL enclousure particle countETMX sus damping recovered.  PSL enclousure
is dusty at 20V rotation speed. Rainy days
as outside condition.
 dusty__PSL.png 
  12855   Tue Feb 28 08:04:48 2017 steveUpdatePEMETMX damping recoveredETMX sus damping recovered.

Note: The giant metal garbage container
was moved from the south west corner of CES
 ETMX.png 
  12856   Tue Feb 28 18:25:22 2017 ranaUpdatePEMETMX damping recoveredHuh? So should we ask them to put the container
back? Or do you have some other theory about
ETMX tripping that is not garbage related?
  
  12884   Mon Mar 13 16:47:41 2017 SteveUpdatePEMY-arm air conditon belts replacedThe east end AC unit is arching over and
running rough at CES. Called for mechanic.......

Both belts were replaced and the
  
  12895   Mon Mar 20 17:12:08 2017 steveUpdatePEMparticle counter inside of PSL enclousureThe logging script is multiplying by 100
instead of 10 !

 enclousure_partical_count.png 
  12908   Mon Mar 27 15:36:27 2017 SteveUpdatePEMparticle counter inside of PSL enclousure 




 HEPA_flow_effects.png 
  12909   Mon Mar 27 16:01:55 2017 SteveUpdatePEMX arm AC set to 68F 

The X arm air conditioner was not
regulating properly. The arm temp was warmer
  
  12930   Thu Apr 6 15:35:44 2017 SteveUpdatePEM envioirmental noiseBuilding:        
Central Engineering Services

     
  
  13046   Wed Jun 7 10:07:00 2017 SteveUpdatePEMair condition thermostateThe Y arm ac thermostate was calibrated
after cooling water relay replacement by
Mike.... yesterday. The set temp is remaind
  
  13183   Thu Aug 10 14:13:23 2017 KiraSummaryPEMtemperature sensorGoal is to build a temperature sensor accurate
to 1 mK. Schematic is shown below. This does
not take into account the DC gain that occurs.
 IMG_20170810_121637~2.jpgIMG_20170810_134422~2.jpg 
  13184   Thu Aug 10 14:14:17 2017 KiraUpdatePEMpreviously built temp sensorI decided to see what was inside the sensor
that had been previously made. According
to elog 1102, the temperature sensor is LM34,
 IMG_20170810_112315.jpg 
  13188   Thu Aug 10 21:22:06 2017 ranaSummaryPEMtemperature sensor
Should we use the AD590 or the
AD592? They're sort of the same, but
have slightly different packages and specs.
Given
 tempsensnoise2.pdftempnoise_final.pdf 
  13190   Fri Aug 11 10:27:49 2017 KiraUpdatePEMtemperature sensorSince there seems to be little difference
between AD590 and AD592, I guess we could
just go with the AD590. The temperature noise
  
  13191   Fri Aug 11 10:48:39 2017 KiraUpdatePEMtemperature sensorQuick update: we actually have AD587KRZ
and AD592, so we could start by using that
and seeing how it works.
  
  13193   Fri Aug 11 11:56:02 2017 ranaUpdatePEMtemperature sensorMight as well order several of a few different
varieties today. Its good to have some extra
in stock; we don't always want to have
  
  13194   Fri Aug 11 12:27:25 2017 KiraUpdatePEMtemperature sensorUsed AD592CNZ and AD586 (5V output) to
create a circuit that works and is responsive
to temperature changes. At room temp, using
 IMG_20170811_121608.jpgIMG_20170811_121619.jpg 
  13202   Mon Aug 14 09:49:18 2017 KiraUpdatePEMtemperature sensorDecided to try adding in an OP amp just
to see if it would work. Added LT1012
and a 100k resistor to the circuit (I originally
 IMG_20170814_092452.jpgIMG_20170814_092513.jpg 
  13203   Mon Aug 14 12:52:33 2017 KiraUpdatePEMtemperature sensorI didn't realize that the LT1012 needed
an additional input to function. I added
in +15V and -15V to pins 7 and 4, respectively and
 IMG_20170814_121131.jpgIMG_20170814_121139.jpgIMG_20170814_121758~2.jpg 
  13209   Tue Aug 15 11:50:21 2017 KiraSummaryPEMtemp sensor packaging/mountFor the final packaging/mounting of the
sensor to the seismometer, I have thought
of two options.
  
  13210   Tue Aug 15 13:32:38 2017 KiraUpdatePEMtemperature sensorTested to make sure that even when only
the AD586 was heated that there was no change
in the reading. I did so by placing the AD586
  
  13214   Wed Aug 16 16:05:53 2017 KiraUpdatePEMtemp sensor PCBTried taking the circuit from the breadboard
to the PCB. I attached all the components
to adapters that would allow them to be connected
 IMG_20170816_154514.jpgIMG_20170816_154541.jpg 
  13224   Thu Aug 17 10:41:58 2017 KiraUpdatePEMtemp sensor PCBGot it to work. One of the connections
was faulty. I decided to check the temperature
measured against a thermometer. The sensor
 IMG_20170817_095917.jpg 
  13232   Mon Aug 21 13:07:08 2017 KiraUpdatePEMtemp sensor PCBOn Friday, I cleaned up the circuit so
that there are only three connections needed
(+15V, -15V, GND) and a BNC connector for
 IMG_20170821_124121.jpgIMG_20170821_124429~2.jpgIMG_20170821_124108.jpg 
  13269   Tue Aug 29 15:41:17 2017 KiraSummaryPEMheater circuitI worked with Kevin and Gautam to create
a heater circuit. The first attachment is
Kevin's schematic of the circuit. The
 heater_circuit.pdfsimulation.pngheater_setup.jpgIMG_20170829_131126.jpg 
  13272   Wed Aug 30 06:45:32 2017 KevinSummaryPEMNew Heater CircuitI changed the heater circuit described
in this
elog to a current sink. The new and old
 circuit.pdf 
  13285   Fri Sep 1 15:46:12 2017 KiraUpdatePEMtemp sensor updateI took off the AD590 and attached it to
two long wires leading out from the board.
This will allow us to attach the sensor to
 IMG_20170901_144729.jpg 
  13292   Tue Sep 5 09:47:34 2017 KiraSummaryPEMheater circuit calculationsI decided to calculate the fluctuation
in power that we will have in the heater
circuit. The resistors we ordered have 50
  
  13295   Tue Sep 5 17:18:17 2017 KiraUpdatePEMtemp sensor updateToday, I stuck on the sensors to a metal
block using a flag, rubber bands, and some
thermal paste (1st attachment). I then wrapped
 IMG_20170905_144924.jpgIMG_20170905_165042.jpg 
  13296   Tue Sep 5 17:52:06 2017 KiraUpdatePEMtemp sensor updateto get the sensors to read the same values
they have to be in direct thermal contact
with the metal block - there can't be
  
  13302   Fri Sep 8 07:54:04 2017 SteveUpdatePEMM8.1 eqNothing tripped. No obvious damage.  M8.1.png 
  13303   Fri Sep 8 10:22:30 2017 SteveUpdatePEMtemp sensor updateThe weight of SS can with copper liner 
is 12.2 kg

Is 1 Amp for the heating jacket
  
  13309   Mon Sep 11 16:46:09 2017 SteveUpdatePEMearthquakes


 M5.4eq.png 
  13311   Tue Sep 12 11:44:16 2017 KiraUpdatePEMtemp sensor updateGot it to work. A cable was broken and
the AD586 also broke at the same time so
it took a while to find the problem. I had
  
  13322   Tue Sep 19 14:00:41 2017 SteveUpdatePEMearthquakesNo sus tripped. Seimometers do not see
the 5.3M  ?

 7.1MX5.3J.png 
  13397   Mon Oct 23 09:17:41 2017 SteveUpdatePEMants alartDo not leave organic trash or food boxes
in the 40m to attrack ants !
 ants.jpgants2.jpg 
  13402   Fri Oct 27 09:34:20 2017 SteveUpdatePEMearthquakesLompoc 4.3M and 3.7M Avalon

 
 recentEQs.png 
  13419   Wed Nov 8 16:39:24 2017 KiraUpdatePEMADC noise measurementGautam and I measured the noise of the
ADC for channels 17, 18, and 19. We plan
to use those channels for measuring the noise
 ADC-fit.pngIMG_20171108_162532.jpgIMG_20171108_162556.jpg 
  13424   Fri Nov 10 13:46:26 2017 SteveUpdatePEMM3.1 local earthquakeBOOM
SHAKA-LAKA
 3.1M_local_EQ.png 
  13427   Tue Nov 14 16:02:43 2017 KiraSummaryPEMseismometer can testingI made a model for our seismometer can
using actual data so that we know approximately
what the time constant should be when we
 time_const.png 
  13438   Tue Nov 21 16:00:05 2017 KiraUpdatePEMseismometer can testingI performed a test with the can last week
with one layer of insulation to see how well
it worked. First, I soldered two heaters
 cooling_fit.pngIMG_20171121_164835.jpg 