Entry  Wed Dec 30 22:17:07 2009, kiwamu, Update, General, Camera input and monitor output 
The input channels of the cameras and the output channels for the monitors are summarized on the
wiki.
The channel table on the wiki is very helpful when you want to make a change in the video matrix.
Entry  Mon Jan 18 23:44:19 2010, kiwamu, Update, Electronics, triple resonant circuit for EOM whole_circuit.pngdesigned_circuit.png
The first design of the triple resonant EOM circuit has been done.
If only EOM has a loss of 4 Ohm, the gain of the circuit is expected
to be 11 at 55MHz 
Entry  Tue Jan 19 02:39:57 2010, kiwamu, Update, Electronics, design complete --- triple resonant circuit for EOM --- realistic.pngscaling.png
The design of the triple resonant circuit has been fixed. 
I found the optimum configuration, whose gain is still 11 at 55MHz even
if there are realistic losses.
    Reply  Tue Jan 19 03:27:47 2010, kiwamu, Update, Electronics, Re: triple resonant circuit for EOM 
1. You are right, the gain for the single resonant circuit was about 9.3 in my measurement.
But the reason why the triple is better than the single resonant circuit comes from the transformer.
The impedance can be degraded by a loss of the transformer, because it got worse after applying the transformer in the past measurement.
    Reply  Tue Jan 19 23:26:07 2010, kiwamu, Update, Electronics, Re:Re: triple resonant circuit for EOM matching_edit.pngeq1.pngdesigned_response.png


    
        
            Quote:
        
        
            
            5.  For the impedance matching, I will select a transformer so that 55MHz is matched. In contrast I will
Entry  Wed Feb 10 17:28:02 2010, kiwamu, Update, Electronics, triple resonant EOM ---- preliminary result mod_depth.png
I have made a prototype circuit of the triple resonant EOM.
The attached is the measured optical response of the system.
The measured gains at the resonances are 8.6, 0.6 and 7.7 for 11MHz, 29.5MHz and 55MHz respectively.
    Reply  Thu Feb 11 16:52:53 2010, kiwamu, Update, Electronics, triple resonant EOM ---- preliminary result 
The commercial resonant EOM of New Focus has the modulation efficiency of 50-150mrad/Vrms.
( This number is only true for those EOM made from KTP such as model4063
and model4463
Entry  Fri Feb 12 13:15:41 2010, kiwamu, Update, Electronics, triple resonant EOM --- liniaryity test linearity_edit.png

I have measured the linearity of our triple resonant EOM (i.e. modulation
depth versus applied voltage)
Entry  Fri Feb 12 18:58:46 2010, kiwamu, Update, Green Locking, take some optics away from the ETM end table DSC_1164.JPGDSC_1172.JPG
In the last two days Steve and I took some optics away from the both ETM end table.
This is because we need an enough space to set up the green locking stuff into the end table, and also need to know how much space is available.
Optics we took away are : Alberto's RF stuff, fiber stuff and some optics
    Reply  Tue Feb 16 11:12:51 2010, kiwamu, Update, Green Locking, Re:take some optics away from the ETM end table 


    
        
            Quote:
        
        
            
            
            
  
    Reply  Tue Feb 16 16:24:30 2010, kiwamu, Update, Green Locking, Re:Re:take some optics away from the ETM end table 
I put the TRY_PD back to the end table and aligned it. Now it seems to be working well.


    
        
            Quote:
        
        
            
Entry  Fri Feb 19 15:29:14 2010, kiwamu, Update, COC, Gluing dumbbells and magnets 
Jenne and kiwamu
We have glued the dumbbells to the magnets that will be used for the
ITMs 
Entry  Fri Feb 19 16:40:43 2010, kiwamu, Update, Green Locking, rearrange the optics on the end table DSC_1202.JPGDSC_1207.JPG
Koji and kiwamu
The existing optics on the ETMX/ETMY end table were rearranged in this
morning.
Entry  Tue Feb 23 19:00:45 2010, kiwamu, Configuration, VAC, vent finished 
The vent has been finished.
Now the pressure inside the chamber is 760 torr, and it's getting equilibrium with the atmospheric pressure.
Therefore we are ready and can open the door of the chamber tomorrow.
Entry  Tue Mar 2 12:20:54 2010, kiwamu, Update, PSL, stray beam 
In order to block stray beams, I have put some beam dumps and razor blades on the PSL  table.
There were three undesired spots in total. I found two spots on the south side door of the PSL room, close to Mach-Zehnder.
Another spots was on the middle of the north door. Now they all are blocked successfully.
Entry  Thu Mar 18 15:33:17 2010, kiwamu, Summary, Electronics, advantege of our triple resonant EOM electrode.png
In this LVC meeting I discussed about triple resonant EOMs with Volker who was a main person of development of triple
resonant EOMs at University of Florida.
Actually his EOM had been already installed at the sites. But the technique to make a triple resonance is different from ours.
    Reply  Sat Mar 20 18:34:19 2010, kiwamu, Summary, Electronics, RE:advantege of our triple resonant EOM 
Yes, I found it.
Their advantage is that their circuit is isolated at DC because of the input capacitor.
And it is interesting that the performance of the circuit in terms of gain is supposed to be roughly the same as our transformer configuration.
Entry  Tue Mar 30 21:11:42 2010, kiwamu, Summary, Green Locking, conversion efficiency of PPKTP efficiency_waist_edit.png
With a 30mm PPKTP crystal the conversion efficiency from 1064nm to 532nm is
expected to 3.7 %/W.
Therefore we will have a green beam of more than 20mW by putting 700mW
    Reply  Wed Mar 31 02:57:48 2010, kiwamu, Update, Green Locking, frequency counter for green PLL FCnoise.png
Rana found that we had a frequency counter SR620 which might be helpful for lock acquisition of the green phase
lock. 
It has a response of 100MHz/V up to 350MHz which is wide range and good for our purpose. 
    Reply  Wed Mar 31 11:52:32 2010, kiwamu, Summary, Green Locking, Re:conversion efficiency of PPKTP 
Good point. There is a trick  to avoid a divergence.
Actually the radius of the cylindrical wave is set to the spot size at the surface of the crystal instead of an actual beam waist. This is the
idea Dmass told me before.
    Reply  Mon Apr 12 14:20:10 2010, kiwamu, Update, Green Locking, PZT response for the innolight 
I measured a jitter modulation caused by injection of a signal into
laser PZTs.
The measurement has been done by putting a razor blade in the middle way of the beam path to cut the half of the beam spot, so that a change of
Entry  Wed Apr 21 10:09:23 2010, kiwamu, Update, Green Locking, waist positon of Gaussian beam in PPKTP crystals focal_positin_edit.png
Theoretically the waist position of a Gaussian beam (1064) in our PPKTP crystal differs by ~6.7 mm from that of the incident Gaussian beam.
So far I have neglected such position change of the beam waist in optical layouts because it is tiny compared with the entire optical path.
But from the point of view of practical experiments, it is better to think about it.
    Reply  Tue Apr 27 14:18:53 2010, kiwamu, Update, Green Locking, waist positon of Gaussian beam in PPKTP crystals mode_in_PPKTP.png
The mode profile of Gaussian beams in our PPKTP crystals was calculated.
I confirmed that the Rayleigh range of the incoming beam (1064 nm) and that of the outgoing beam (532 nm)
is the same.
Entry  Fri May 7 21:55:59 2010, kiwamu, Update, PSL, remove Mach-Zehnder  NO_MachZehnder_s.jpg
[Koji, Kiwamu]
The Mach-Zehnder on the PSL table was removed.
A path for 166 MHz modulation in the Mach-Zehnder (MZ) was completely removed, the setup for another path remains the same as before.
    Reply  Wed May 12 10:33:32 2010, kiwamu, Update, Green Locking, Re: Reflection from ETM and ITM ! 
The procedure you wrote down as a standard is right.   I explain reasons why we didn't do such way. 


For our situation, we can rotate the polarization angle of the incident beam by using a HWP in front of the Faraday.  
Entry  Sun May 16 12:51:08 2010, kiwamu, Update, Green Locking, reflected beam at PD 
Mode matching to the cavity has been done.
Now the reflection from the cavity is successfully going into the PD.
However I could not see any obvious error signal.
Entry  Thu May 20 12:10:44 2010, kiwamu, Update, Photos, ETMY end table ETMY_s.png
 I updated the photo of ETMY end table on the wiki.
http://lhocds.ligo-wa.caltech.edu:8000/40m/Optical_Tables
Entry  Thu May 20 12:34:46 2010, kiwamu, Configuration, 40m Upgrading, optical breadboards with legs leg1_small.pngleg2_small.png
Yesterday Steve and I revived two legs to mount some optical breadboards outside of the end table.
These legs had been used as oplev's mounts many years ago, but now they are served for 40m upgrading. These are really nice.

    Reply  Thu May 20 13:29:40 2010, kiwamu, Update, Green Locking, mode profile at PPKTP crystal PPKTPmode.png
 I measured again the mode profile of the beam going through the PPKTP crystal by using the beam scan.
The aimed beam waist is 50 um (as described in entry 2735), 
    Reply  Thu May 20 14:18:59 2010, kiwamu, Update, Green Locking, mode profile of 40m cavity MMT40mcavity.png
The mode profile of the green beam going through 40m cavity was measured.
According to the fitting the coupling efficiency to the cavity is 98.46%, but still the beam looks loosely focused
Entry  Mon May 24 14:28:35 2010, kiwamu, Update, Electronics, bad power supply of a vme rack 
In this morning I found daqawg didn't work.
After looking for the cause, I found one of the vme racks mounted on 1Y6 doesn't work correctly.
It looks like the vme rack mounting c0daqawg could not supply any power to the frontends.
    Reply  Tue May 25 07:22:59 2010, kiwamu, Update, Electronics, bad power supply of a vme rack 
Notes on May 25th
 Don't do the following things !! This causes bad cross-talking
Entry  Tue May 25 07:58:23 2010, kiwamu, Update, elog, elog down 
I found the elog got down around 7:30 am in this morning.
So I restarted it by running the script: "start-elog-nodus" as instructed on the wiki.
http://lhocds.ligo-wa.caltech.edu:8000/40m/How_To/Restart_the_elog
    Reply  Tue May 25 09:12:46 2010, kiwamu, Configuration, Green Locking, effect from air conditioner green_spot.png
We should completely turn off the air conditioner when working on green locking.
Even if green beams propagates inside of chambers, the air conditioner
does affect the spatial jitter of the beam. 
    Reply  Tue May 25 10:06:09 2010, kiwamu, Update, Electronics, bad power supply of a vme rack 
 I got a VME crate from Peter's lab. It is already installed in
1Y6 instead of the old broken one.
I checked its power supply, and it looked fine. It successfully supplies +5, +12 and -12 V. And then I put c0daqawg and c1pem1 back from 1Y7.
    Reply  Tue May 25 16:32:26 2010, kiwamu, HowTo, Electronics, front ends are back 
 [Alex, Joe, Kiwamu]
Eventually all the front end computers came back !! 
    Reply  Wed May 26 04:14:21 2010, kiwamu, Update, Green Locking, locked OLTF_endPDH.png
I guess I succeeded in locking of the cavity with the green beam 
 Strictly speaking, the laser frequency of the end NPRO is locked to the 40 meter arm cavity.
    Reply  Thu May 27 02:22:24 2010, kiwamu, Update, Green Locking, more details stimes.pngspectrum.pngETMX_small.png
 Here are some more plots and pictures about the end PDH locking with the green
beam. 
-- DC reflection
Entry  Thu May 27 10:30:32 2010, kiwamu, HowTo, Green Locking, PSL setup for green locking 
 I leave notes about a plan for the green locking especially on the PSL
table.
    Reply  Sun May 30 17:51:04 2010, kiwamu, HowTo, PEM, Allegra dataviewer 
I found the dataviewer didn't work only on Allegra. This thing sometimes happened as described in
the past entry.
I rebooted Allegra, then the problem was fixed.
    Reply  Mon May 31 00:10:18 2010, kiwamu, Update, IOO, MC alignment 
  [Alberto, Kiwamu]
The MC alignment is getting better by steering the axis of the incident
beam into the MC.
    Reply  Mon May 31 17:47:34 2010, kiwamu, Update, IOO, today's plan : MC alignment 
[Alberto, Kiwamu]
0. have a coffee and then dress up the clean coat.
1. level the MC table
    Reply  Thu Jun 3 13:14:27 2010, kiwamu, Update, IOO, mode measurement of new input optics inside_vac_2.png
I corrected the sketch of the new IOO. 
The sketch in the last entry was also replaced by the new one. 
http://nodus.ligo.caltech.edu:8080/40m/3029 
    Reply  Thu Jun 3 14:01:51 2010, kiwamu, Update, IOO, mode measurement of new input optics check_measurement_edit.png
I checked the measured data of the mode profile which was taken
on the last Tuesday.
For the vertical profile, 
    Reply  Wed Jun 9 11:13:11 2010, kiwamu, Update, Green Locking, lock with PDH box 
A progress on the end PDH locking :

by using a modified PDH box the green laser on the X-end station is locked to the arm cavity.
    Reply  Fri Jun 11 11:54:42 2010, kiwamu, Update, Green Locking, end PDH with thermal feedback LPF.pngthermal_feedback.png
A thermal feedback was installed to the end PDH locking and it works well. There
are no saturations 
    Reply  Fri Jun 11 14:31:04 2010, kiwamu, Update, IOO, mode matching of new IOO profile_MMT.pngdist_MMO.png
We decided not to care about the mode after MMT1.
So far Koji, Alberto and I have measured the beam profile after MMT1,
 but we are going to stop this measurement and go ahead to the next step i.e. putting MMT2
    Reply  Tue Jun 15 16:28:32 2010, kiwamu, Update, IOO, Mode Profile after Mode Matching Telescope newIOO_overlap_edit.png
We obtained a good mode match overlap of 99.0% for the new IOO.
And if we move the position of MMT2 by another 10 cm away from MMT1,
we will have 99.6% overlap. 
    Reply  Fri Jun 18 21:45:39 2010, kiwamu, Update, IOO, Mode Profile after Mode Matching Telescope (Round 2) MMT20100618_edit.pngnewIOO_overlap_edit.png
           [Joe, Kiwamu]
The better mode overlap of 99.3%
    Reply  Sun Jun 20 18:28:25 2010, kiwamu, Update, Green Locking, Re: lock with PDH box 
On the wiki I summarized about the modification of the PDH box which is currently running on the end PDH locking. 
http://lhocds.ligo-wa.caltech.edu:8000/40m/Electronics/PDH_Universal_Box
The box was newly labeled "G1"
ELOG V3.1.3-