  5378   Sat Sep 10 16:10:42 2011 KeikoUpdateLSC3f demodulation board checkThere is a LP filter just after the RF
input of an demodulation board (its schematic
can be found as D990511-00-C on DCC). I have
 REFL33-input-filter.png 
  5380   Sat Sep 10 18:57:52 2011 KeikoUpdateLSC3f demodulation board checkThe
phase delay due to the RF input filter on
the demodulation board will not bother the
  
  5385   Sun Sep 11 22:36:32 2011 KeikoUpdateLSC3f demodulation board checkFilters
at the RF inputs of REFL33 and REFL165 demodulation
boards were measured again. The filters will
 REFL33.pngREFL165.png 
  5386   Mon Sep 12 13:24:07 2011 KeikoUpdateLSC3f demodulation board checkI also quickly
checked the orthogonality of the demodulation
board for REFL33 and REFL165 using function generators
  
  5387   Mon Sep 12 16:27:01 2011 KeikoUpdateLSC3f demodulation board checkWait. I am checking the whitening filters
of the 33 and 165 demodulation boards.
Also, 
  
  5388   Mon Sep 12 18:40:35 2011 KeikoUpdateLSC3f demodulation board checkLSC-REFL33-I-IN1(IN2, OUT) and   
  5394   Tue Sep 13 15:00:25 2011 KeikoUpdateLSC3f demodulation board checkWhitening filters for the REFL33 &
165 demodulated channels were measured and
confirmed that they are working. They can
 WF33.pdfWF165.pdf 
  5399   Tue Sep 13 23:08:51 2011 KeikoUpdateLSC3f demodulation board checkKeiko,
Jamie , Kiwamu
The
 REFL33-modified.pngREFL165-modified.png 
  5412   Thu Sep 15 01:06:20 2011 KeikoUpdateLSC3f demodulation board checkIn addition to REFL 33 ans 165, I checked
the orthogonality for the other existing
three channels.
  
  5413   Thu Sep 15 01:17:10 2011 KeikoUpdateLSCMICH locked and attempt to lock PRCL Anamaria, Keiko
- We aligned MICH and were successfully
locked MICH using AS55Q. The other
  
  5440   Fri Sep 16 21:26:12 2011 KeikoUpdateLSC3f demodulation board checkThe demodulation
phases and gains for the all existing channels, 
  
  5441   Fri Sep 16 21:36:25 2011 KeikoUpdateLSCPOY11 and POY55 were added New
channels, POP55 and POY11 are connected to
the rack and now available on the data system.
  
  5445   Sat Sep 17 01:53:41 2011 KeikoUpdateLSCPOY and POP beams clipped Keiko, Paul, Kiwamu
We found
  
  5464   Mon Sep 19 16:44:16 2011 KeikoHowToLSCProcedure for the demodulation board check Here
I note the procedure for the demodulation
board orthogonality check for the future
  
  5472   Mon Sep 19 23:19:40 2011 KeikoUpdateIOOAM modulation mistery Keiko, Anamaria
We started to investigate the AM
modulation mistery again. Checking just after
  
  5474   Tue Sep 20 03:02:23 2011 KeikoUpdateLSClocking activity tonight Keiko,
Anamaria, Koji
We
  
  5483   Tue Sep 20 16:31:24 2011 KeikoUpdateIOOSmall modulation depth Modulation
resonator box is removed and the modulation
  
  5484   Tue Sep 20 16:38:25 2011 KeikoUpdateIOOSmall modulation depthResonator
box and the modulations are back now. But
the modulation depth seems to be a bit smaller
  
  5491   Tue Sep 20 23:01:37 2011 KeikoUpdateIOOAM modulation misteryKeiko, Suresh
AM modulations are still there ... the
  
  5495   Wed Sep 21 02:49:39 2011 KeikoSummaryLSCLSC matricesI created 3 kinds of LSC matrices, PRMI condition
with carrier resonant in PRC, PRMI condition
  
  5502   Wed Sep 21 16:44:18 2011 KeikoUpdateIOOAM modulation misteryAM
modulation depths are found to be 50 times smaller
 P9210138.JPGP92101381.jpg 
  5504   Wed Sep 21 18:53:03 2011 KeikoUpdateIOOAM modulation miseryThe signal
offset due to the AM modulation is estimated
by a simulation for PRCL for
 AM0.pngAMratio1.pngAMratio50.png 
  5512   Thu Sep 22 01:45:41 2011 KeikoUpdateLSCLocking status updateKeiko, Anamaria
Tonight we want to measure the LSC
matrix for PRMI and compare the simulation
 PRCL-OLT.pdfMICH-OLT.pdf 
  5520   Thu Sep 22 17:29:42 2011 KeikoUpdateIOOAM modulation misteryAM
modulation will add offset on SRCL signal
as well as PRCL signal. About 2% of the signal
 AMmod0MICH.pngAMmod1e-1MICH.pngAMmod0SRCL.pngAMmod3e-3SRCL.pngAMmod3e-3SRCL-AS55I.png 
  5538   Sat Sep 24 09:55:42 2011 KeikoUpdateIOOAM modulation misteryFrom the night day before yesterday (Sep
22nd, Thursday night. Sorry for my late update),
there
  
  6358   Mon Mar 5 18:12:00 2012 KeikoUpdateLSCRAM simulation update I wrote an RAM simulation script
... it calculates the LSC signal offset and
the operation point offset depending on the
 Mar5RAM2.pngMar5RAM3.png 
  6363   Tue Mar 6 15:22:02 2012 KeikoUpdateLSCRAM simulation update

    

       
            
  
  13065   Thu Jun 15 14:24:48 2017 Kaustubh, JigyasaUpdateComputersOttavia Switched OnToday, I and Jigyasa connected the Ottavia
to one of the unused monitor screens Donatella.
The Ottavia CPU had a label saying 'SMOKED''.
  
  13067   Thu Jun 15 19:49:03 2017 Kaustubh, JigyasaUpdateComputersOttavia Switched OnIt has been working fine the whole day(we
didn't do much testing on it though).
We are leaving it on for the night.
  
  13068   Fri Jun 16 12:37:47 2017 Kaustubh, JigyasaUpdateComputersOttavia Switched OnOttavia had been left running overnight
and it seems to work fine. There has been
no smell or any noticeable problems in the
  
  13071   Fri Jun 16 23:27:19 2017 Kaustubh, JigyasaUpdateComputersOttavia Connected to the Netgear BoxI just connected the Ottavia to the Netgear
box and its working just fine. It'll
remain switched on over the weekend.
  
  12999   Fri May 19 19:18:53 2017 KaustubhSummaryGeneralTesting of the new Photo Detectors ET-3010 and ET-3040Motivation:

I got some hands-on-experience
on using RF photodetectors and the Network
 IMG_20170519_173247922.jpgIMG_20170519_173253252.jpgIMG_20170519_173300174.jpgPD_test_setup.png 
  13005   Mon May 22 18:20:27 2017 KaustubhSummaryGeneralTesting of the new Photo Detectors ET-3010 and ET-3040I am adding the text files with the data
readings and paramater settings along
with the Bode Plot of the data. I plotted
 ET-3040_test.zipET-3040_test.pdf 
  13009   Tue May 23 18:09:18 2017 KaustubhConfigurationGeneralTesting ET-3010 PDIn continuation with the previous(ET-3040
PD) test.

The ET-3010 PD requires to be fiber
  
  13011   Wed May 24 18:19:15 2017 KaustubhUpdateGeneralET-3010 PD TestSummary:

In continuation to the previous
test conducted on the ET-3040 PD,  I
 PD_test_setup.pngET-3010_test.pdfET-3010_test.zip 
  13016   Sat May 27 10:26:28 2017 KaustubhUpdateGeneralTransimpedance CalibrationUsing Alberto's paper LIGO-T10002-09-R
titled "40m RF PDs Upgrade", I
calibrated the vertical axis in the bode
 ET-3040_test_transimpedance.pdfET-3010_test_transimpedance.pdfFormula_for_Transimpedance.pdf 
  13077   Fri Jun 23 02:43:43 2017 KaustubhHowToComputer Scripts / ProgramsTaking Measurements From AG4395ASummary:

I have written a code(a basic one
which needs a lot of improvements, but still
 Test_Files_and_Code.zipBode_Plot_with_Error_Bands.pdf 
  13078   Fri Jun 23 02:55:18 2017 KaustubhUpdateComputer Scripts / ProgramsScript RunningI am leaving a script running on the Pianoso
for the night. For this purpose, even
the AG4395A is kept on. I'll see the
  
  13086   Thu Jun 29 00:13:08 2017 KaustubhUpdateComputer Scripts / ProgramsTransfer Function TestingIn continuation to my previous posts, I
have been working on evaluating the data
on transfer function. Recently, I have calculated
 Correlation_Plot.pdf2x100_Test_Files_and_Code_and_Correlation_Files.zip 
  13109   Mon Jul 10 21:31:15 2017 KaustubhHowToComputer Scripts / ProgramsDetails on Cavity Scan AnalysisSummary:

The
following elog describes the procedure followed
 Attachments.zip 
  13116   Thu Jul 13 16:10:34 2017 KaustubhSummaryComputer Scripts / ProgramsCavity Scan Simulation CodeThe code
to produce a cavity scan simulation and then
fitting the data and re-evaluating the initiallt
  
  5470   Mon Sep 19 21:19:25 2011 KatrinUpdateGreen LockingBroadband photodiode characterizationAnother Hamasutu S3399 photodiode was tested
with the electronic circuit as described
in LIGO-D-1002969-v.
 current_noise_S3399.pdfidet_S3399.pdfS3399_response.pdfcurrent_noise_S3399_v2.pdfidet_S3399_v2.pdf 
  5511   Thu Sep 22 01:05:28 2011 KatrinUpdateGreen LockingNew modulation frequency (Y arm)[Kiwamu / Katrin]
 
On Wednesday, the green light was
  
  5531   Fri Sep 23 17:31:14 2011 KatrinUpdateGreen LockingStray light reduction (Y)I inserted several beam blocks and iris
on the Y arm Green table. There was/is lots
of stray light because a lot of the mirrors
  
  5585   Fri Sep 30 15:22:17 2011 KatrinUpdateGreen LockingWhat happened on green YARM? 
This is a kind
  
  5619   Tue Oct 4 20:34:20 2011 KatrinUpdateGreen Locking7kHz Peak in servo input YARM[Kiwamu, Katrin]
As reported earlier an oscillation
around 7kHz is an the PDH error signal. The
 servoinput.pngservoinput2.png 
  5623   Wed Oct 5 18:31:02 2011 KatrinUpdateGreen LockingExchanged mirror on YARM tableOn the Green YARM end table the second
mirror behind the laser has been exchanged.
Reason: The light is impinging on
  
  5631   Fri Oct 7 17:35:26 2011 KatrinUpdateGreen LockingPower on green YARM tableAfter all realignment is finished, here
are the powers at several positions:
 
 DSC_3496_power.JPG 
  5646   Mon Oct 10 18:53:04 2011 KatrinUpdateGreen LockingMirrors whose angle of incidence is not 45The angle of incidence of light is for
some mirrors on the YARM end table different
from 45° even though the mirrors are
  
  5657   Wed Oct 12 18:54:02 2011 KatrinUpdateGreen Locking60 Hz oscillation due to broken BNC cableThere was a 60 Hz and 120 Hz oscillation
on the green PDH photo diode output. After
a long search, I could identify that
  