  12084   Wed Apr 20 14:36:45 2016 SteveUpdatePEMdusty labIt is worth wiping table top covers. Use
isopropanol soaked lint free wipes.

 
 AP_accm.jpgwiped_AP.jpgtemp-partic_6months.png3_years_PEM.png 
  12087   Fri Apr 22 13:58:13 2016 SteveUpdatePEMleaky roof is fixedDan sealed the leak today.

 
 leakyRoof_(2).jpg 
  12096   Thu Apr 28 08:49:47 2016 SteveUpdatePEMpossible noise sources schedule
Building:        
Campus (see attached Map)        

       
 Campus_B&W_Map-2.pdf 
  12209   Tue Jun 21 14:12:10 2016 SteveUpdatePEM vacuum envelope wipedI wiped down the cranes with wet towel
and Mario our janitor did the chamber tops
with the tubes.
 60dPEM.png 
  12318   Thu Jul 21 08:24:20 2016 SteveUpdatePEMants alartThe heat drives the ants to the lab! 
Make sure the light doors are tight on the
chambers.
 ants_Alart.jpg 
  12365   Wed Aug 3 14:52:37 2016 SteveSummaryPEMGuralps as connectedGuralps as connected with
pictures
  
  12383   Mon Aug 8 10:35:12 2016 SteveUpdatePEMvent 78 day 38 




 Vent38days.pngvent78d40RgaBg.png 
  12406   Fri Aug 12 21:26:28 2016 ranaUpdatePEMMic Self NoiseSeems to good to be true. Maybe you're
over fitting? Please put all the traces on
one plot and let us know how you do the parameter
  
  12408   Mon Aug 15 12:23:56 2016 PrafulUpdatePEMMic Self NoiseI didn't have a separate training set
and data set, so I think that's why the
graphs came out looking too good. The units
 9x 
  12429   Mon Aug 22 16:33:32 2016 SteveUpdatePEMthe lab temp is upThe IFO room temp is up a bit and it is
coming down. The out side temp is not really
high.
 temp.png 
  12431   Mon Aug 22 18:35:16 2016 PrafulUpdatePEMthe lab temp is upThe temperature is decreasing slowly but
is still above 24 C.

 temp_plot.pngtemp_plot.pngtemp_plot.png 
  12498   Fri Sep 16 14:15:28 2016 steveUpdatePEMpartical countsSouth end flow bench and both clean room
assembly flow benches measured zero counts
for 0.3 and 0.5 micron size particales.
 80days.png 
  12538   Fri Oct 7 15:36:03 2016 SteveUpdatePEMthe lab temp is upThe IFO room temp is up




 tempUp.pngPEM4d.png 
  12558   Thu Oct 13 14:49:57 2016 KojiConfigurationPEMXLR(F)-XLR(M) cable took from the fibox to the Blue microphone[Gautam Koji]

XLR(F)-XLR(M) cable for the blue
microphone is missing. Steve ordered one.
  
  12582   Thu Oct 27 09:38:32 2016 SteveUpdatePEMmouseWe may have a mouse in the lab. 
Do not leave any food scrap in trash ! Traps will be set.
 mouse.jpg 
  12605   Tue Nov 8 08:51:59 2016 SteveUpdatePEMmouse hole sealedThis is where the mammal came though. It
is reach able from room 108 CES

 CES108rs.jpg 
  12629   Mon Nov 21 11:30:01 2016 SteveUpdatePEMrat is cut and removedLast jump at rack Y2.  rat#2.png 
  12656   Fri Dec 2 10:57:08 2016 steveUpdatePEM door seal replacedThe south end door leaky weather seals
replaced.

The aim is here to get some overpressure
 1_year_PEM.png 
  12673   Thu Dec 8 07:56:05 2016 SteveUpdatePEMEQ6.5m Northen CANo damage. ITMY is glitching, so it has
not been damped.

 
 eq6.5FerndaleCA.png16d_glitching-_trend.pngEQ6.5_&4.7mFerndaleCa.png 
  12687   Thu Dec 29 10:24:56 2016 SteveUpdatePEMEQ5.7mHawthorn NVSus damping restored.

 
 eq5.7HawthorneNV.png 
  12696   Mon Jan 9 09:18:47 2017 SteveUpdatePEMpower glitchThere was a power glitch last night around
1:15am

The vacuum was not effected.
 MondayMorning.png 
  12711   Fri Jan 13 10:53:03 2017 SteveUpdatePEMdoors are fixedControl room to outside door was
realigned. 

  
  12712   Fri Jan 13 14:18:28 2017 SteveUpdatePEMair condition fixedThe old control room AC  has been
stick in heating mode for
about 2 months. It's thermostate
 PEM_120d.png 
  12743   Fri Jan 20 14:42:12 2017 SteveUpdatePEMCaltech weather stationWe should be able to connect to this station   
  12744   Fri Jan 20 17:12:37 2017 SteveUpdatePEMEM172 mic is hooked up in the PSLGautam and Steve,

It is hanging in the midle of the
PSL enclosure. Wired to 1X1 to get plus and
 EM172c.jpg 
  12789   Thu Feb 2 17:34:25 2017 ranaUpdatePEMEM172 mic is hooked up in the PSLI don't know if anyone looked at the
time series (not trend) or spectrum of the
Microphone after installation, but it looks
 MicFail.pdf 
  12790   Thu Feb 2 17:43:20 2017 gautamUpdatePEMEM172 mic is hooked up in the PSLI had noticed something wonky with the
microphone, but neglected to elog it. I had
tested it after installation by playing a
 Mic_broken.png 
  12836   Fri Feb 17 10:56:12 2017 steveUpdatePEMparticle counter moved into PSL enclousureThe MET#1 particle counter was moved from
CES wall at ITMX to PSL enclousure south
west corner at 11am.
 from_here.jpgto_here.jpgPSL_particles.png 
  12841   Tue Feb 21 10:08:35 2017 steveUpdatePEMnoisy morningOur new janitor Francisco is started working
in IFO room today.

 outside_activity.png 
  12844   Wed Feb 22 08:54:17 2017 steveUpdatePEM PSL enclousure particle countETMX sus damping recovered.  PSL enclousure
is dusty at 20V rotation speed. Rainy days
as outside condition.
 dusty__PSL.png 
  12855   Tue Feb 28 08:04:48 2017 steveUpdatePEMETMX damping recoveredETMX sus damping recovered.

Note: The giant metal garbage container
was moved from the south west corner of CES
 ETMX.png 
  12856   Tue Feb 28 18:25:22 2017 ranaUpdatePEMETMX damping recoveredHuh? So should we ask them to put the container
back? Or do you have some other theory about
ETMX tripping that is not garbage related?
  
  12884   Mon Mar 13 16:47:41 2017 SteveUpdatePEMY-arm air conditon belts replacedThe east end AC unit is arching over and
running rough at CES. Called for mechanic.......

Both belts were replaced and the
  
  12895   Mon Mar 20 17:12:08 2017 steveUpdatePEMparticle counter inside of PSL enclousureThe logging script is multiplying by 100
instead of 10 !

 enclousure_partical_count.png 
  12908   Mon Mar 27 15:36:27 2017 SteveUpdatePEMparticle counter inside of PSL enclousure 




 HEPA_flow_effects.png 
  12909   Mon Mar 27 16:01:55 2017 SteveUpdatePEMX arm AC set to 68F 

The X arm air conditioner was not
regulating properly. The arm temp was warmer
  
  12930   Thu Apr 6 15:35:44 2017 SteveUpdatePEM envioirmental noiseBuilding:        
Central Engineering Services

     
  
  13046   Wed Jun 7 10:07:00 2017 SteveUpdatePEMair condition thermostateThe Y arm ac thermostate was calibrated
after cooling water relay replacement by
Mike.... yesterday. The set temp is remaind
  
  13183   Thu Aug 10 14:13:23 2017 KiraSummaryPEMtemperature sensorGoal is to build a temperature sensor accurate
to 1 mK. Schematic is shown below. This does
not take into account the DC gain that occurs.
 IMG_20170810_121637~2.jpgIMG_20170810_134422~2.jpg 
  13184   Thu Aug 10 14:14:17 2017 KiraUpdatePEMpreviously built temp sensorI decided to see what was inside the sensor
that had been previously made. According
to elog 1102, the temperature sensor is LM34,
 IMG_20170810_112315.jpg 
  13188   Thu Aug 10 21:22:06 2017 ranaSummaryPEMtemperature sensor
Should we use the AD590 or the
AD592? They're sort of the same, but
have slightly different packages and specs.
Given
 tempsensnoise2.pdftempnoise_final.pdf 
  13190   Fri Aug 11 10:27:49 2017 KiraUpdatePEMtemperature sensorSince there seems to be little difference
between AD590 and AD592, I guess we could
just go with the AD590. The temperature noise
  
  13191   Fri Aug 11 10:48:39 2017 KiraUpdatePEMtemperature sensorQuick update: we actually have AD587KRZ
and AD592, so we could start by using that
and seeing how it works.
  
  13193   Fri Aug 11 11:56:02 2017 ranaUpdatePEMtemperature sensorMight as well order several of a few different
varieties today. Its good to have some extra
in stock; we don't always want to have
  
  13194   Fri Aug 11 12:27:25 2017 KiraUpdatePEMtemperature sensorUsed AD592CNZ and AD586 (5V output) to
create a circuit that works and is responsive
to temperature changes. At room temp, using
 IMG_20170811_121608.jpgIMG_20170811_121619.jpg 
  13202   Mon Aug 14 09:49:18 2017 KiraUpdatePEMtemperature sensorDecided to try adding in an OP amp just
to see if it would work. Added LT1012
and a 100k resistor to the circuit (I originally
 IMG_20170814_092452.jpgIMG_20170814_092513.jpg 
  13203   Mon Aug 14 12:52:33 2017 KiraUpdatePEMtemperature sensorI didn't realize that the LT1012 needed
an additional input to function. I added
in +15V and -15V to pins 7 and 4, respectively and
 IMG_20170814_121131.jpgIMG_20170814_121139.jpgIMG_20170814_121758~2.jpg 
  13209   Tue Aug 15 11:50:21 2017 KiraSummaryPEMtemp sensor packaging/mountFor the final packaging/mounting of the
sensor to the seismometer, I have thought
of two options.
  
  13210   Tue Aug 15 13:32:38 2017 KiraUpdatePEMtemperature sensorTested to make sure that even when only
the AD586 was heated that there was no change
in the reading. I did so by placing the AD586
  
  13214   Wed Aug 16 16:05:53 2017 KiraUpdatePEMtemp sensor PCBTried taking the circuit from the breadboard
to the PCB. I attached all the components
to adapters that would allow them to be connected
 IMG_20170816_154514.jpgIMG_20170816_154541.jpg 