40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 252 of 341  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  2695   Mon Mar 22 16:57:45 2010 josephb,daisuke, alexConfigurationComputersMegatron test points working againWe changed the pointer on /cvs/cds/caltech/target/gds/bin/awgtpman
from
/opt/gds/awgtpman    to
  
  3237   Fri Jul 16 15:57:19 2010 josephb,kiwamuUpdateComputersNew X end FE and IO chassis workWe finished setting up the new X end front
end machine (still temporarily called c1scx),
and attached it to its IO chassis. 
  
  3434   Wed Aug 18 12:24:58 2010 josephb,kiwamuUpdateCDSshmem issueApparently its possible to have working
models get into a bad state in regards to
shared memory, which prevents the model from
  
  3432   Wed Aug 18 11:40:59 2010 josephb,kiwamu,yoichiUpdateCDSEnd station working with latest RCG codeWe were able to get the latest SVN checkout
(revision 2009), working with the c1x00 (IOP)
and c1vgl models at the new X end on the
  
  2517   Fri Jan 15 18:53:05 2010 josephb,peter,kojiUpdateComputersAttempted locking with Megatron replacing ETMY front endThis afternoon we attempted to lock the
interferometer using Megatron insteady of
the usual ETMY front end.
  
  2911   Tue May 11 16:38:16 2010 josephb,rana,rolfUpdateCDSCDS questions and thoughts1) What is c1asc doing?  What is ascaux
used for?  What are the cables labeled
"C1:ASC_QPD" in the 1X2 rack really
  
  303   Fri Feb 8 17:55:53 2008 joshConfigurationPEMPEM-AS_MIC now in PSL enclosureI have moved the microphone to the PSL enclosure,
hanging near the south (Y) side from a support
rod for the overhanging storage area so that
  
  780   Fri Aug 1 11:51:15 2008 justingOmnistructureComputersadded /cvs/cds/site directoryI added a /cvs/cds/site directory.  This is
the same as is dicsussed [URL=http://ilog.ligo-la.caltech.edu/ilog/pub/ilog.cgi?group=detector&date_to_view=04/19/2008&anchor_to_scroll_to=2008:04:19:15:54:09-lisab]here[/URL].
 Right now it just has the text file 'cit'
  
  298   Tue Feb 5 17:39:05 2008 jweinerConfigurationPEMPEM-AS_MIC taken down from AS table, will put in PSL enclosure soonI took down the microphone that Andrey hung
above the AS table his first week in lab.
I want to hang the microphone above the PMC
  
  4772   Tue May 31 14:29:00 2011 jzweizigUpdateCDSframesThere seems to be something strange going
on with the 40m frame builder.
Specifically, there is a gap in the
  
  4407   Sun Mar 13 00:00:58 2011 jzweizig, ranaConfigurationDAQNDS2 code change and restart John has changed the NDS2 code and
restarted it on Mafalda. The issue is that
it goes off the rails everytime the DAQD
  
  10711   Thu Nov 13 22:52:48 2014 kateUpdatePEMSeismometers set up for huddle testJenne, Diego, Kate
We want to conduct a huddle test
with the three 40m seismometers (2 Guralps
 Seismic_13Nov2014.pdfseism_closed.jpgseism_open.jpg 
  13866   Fri May 18 19:10:48 2018 keerthanaUpdateGeneralCode for adjusting the oscillator frequency remotlyTarget: Phase locking
can be acheived by giving a scan to the oscilator
frequency. This frequency is now controlled
 frequency_set.jpg 
  13875   Mon May 21 18:02:55 2018 keerthanaUpdateGeneralTesting of the new mini-circuits frequency counterToday, I tested the new mini-circuit frequency
counter by connecting it with the beat signal
output. The frequency counter works fine.
 frequency_counter.jpg 
  13879   Tue May 22 17:29:27 2018 keerthanaUpdateelogMEDM Diagram for the auxilary laser system control and display.(keerthana, gautam, jon)

In the morning, Jon gave me an
overview of the Auxiliary laser system which
 MEDM_aux.png 
  13915   Mon Jun 4 19:41:01 2018 keerthanaUpdate Finesse code for cavity scanThe cavity scan data obtained from the
Finesse simulation is attached here. Fig1
indicates the cavity scan data in the absence
 Fig1.pngFig2.png 
  13924   Thu Jun 7 10:26:36 2018 keerthanaUpdatePSLobserving the resonance signal corresponding to the injected frequency.

(Johannes, Koji,
Keerthana)

The PLL loop ensures that the frequency
 photodetector_alignment.jpgdesign1.PNG 
  13926   Thu Jun 7 14:35:26 2018 keerthanaUpdateelogTable- useful for doing the scanning.I think this table will help us to fix
the scanning range of the Marconi frequency.
This will also help in predicting the position
  
  13939   Mon Jun 11 13:55:33 2018 keerthanaUpdateGeneralProject UpdatesAs of now, I have made the codes needed
to sweep the marconi frequency for taking
the cavity scan data, the photo diode at
  
  13943   Mon Jun 11 19:16:49 2018 keerthanaUpdateelogComparison of the analytical and finesse values of TMS and FSR.The percentage error which I found out
=[(analytical value - finesse value)/analytical
value]*100
 fitting_1.pdf 
  13945   Mon Jun 11 22:18:18 2018 keerthanaUpdateelogComparison of the analytical and finesse values of TMS and FSR.Oopss !! I made a mistake while taking
the values from my notes. Sorry.

  
  13954   Wed Jun 13 11:59:03 2018 keerthanaUpdateelogcommand line enabled code for frequency scanningI have modified the code for frequency
scanning and have made it completely command
line enabled. The code is written in python.
  
  13956   Wed Jun 13 18:08:36 2018 keerthanaUpdate Finesse code for cavity scanThe unit mentioned in the x-axis was wrong.
So I have remade the graphs. The point where
frequency equals to zero is actually the
 finesse1.pdffinesse2.pdf 
  13995   Thu Jun 21 13:24:00 2018 keerthanaUpdateelogThe cavity scan data of June 20(Jon, Keerthana, Sandrine)

We tried to align the AUX and PSL
laser yesterday. We collected the data from
 AS110_Beat.pdfYEND_Beat.pdf 
  14017   Tue Jun 26 10:06:39 2018 keerthanaUpdateAUXFirst Coherent AUX Scan of PRC Using AM Sidebands(Jon, Keerthana, Sandrine)

I am attaching the plots of the
Reflected and transmitted AUX beam. In the
 TRANS.pdfREFL.pdf 
  14045   Sun Jul 8 22:27:25 2018 keerthanaUpdate AUX diagram(Analisa, Keerthana, Sandrine)

So far we tried four different
techniques to scan the AUX laser. They are,
 PLL-single_demodulation.pdfPLL-double_demodulation.pdf 
  Draft   Wed Jul 11 18:13:19 2018 keerthanaSummaryAUXGouy Phase Measurements from AUX-Laser ScansFrom the Measurement Jon made, FSR is 3.967
MHz and the Gouy phase is 52 degrees. From
this, the length of the Y-arm cavity
  
  14057   Thu Jul 12 14:06:39 2018 keerthanaUpdateelogFinesse and Analytical solution - ComparisonI tried to compare the cavity scan data
we get from the Finesse simulation and that
we expect from the Analytical solution. The
 finesse_cavity.pngAnalytical1.pdfFinesse_Analytical.pdfDifference.pdf 
  13938   Mon Jun 11 11:45:13 2018 keerthana UpdateelogComparison of the analytical and finesse values of TMS and FSR.


Quantity
 finesse1.pdf 
  14039   Thu Jul 5 17:33:36 2018 keerthana, sandrineUpdateelogLights not working
N/S ARM FL.
N/S ARM
INC.


These two lights inside
the 40m-lab are not working.
  
  14040   Thu Jul 5 17:58:04 2018 keerthana, sandrineUpdateelog (Analisa, Sandrine, Keerthana)

Today Annalisa helped us to understand
the new set up used to make the frequency
 setup1.jpgsetup2.jpg 
  6360   Mon Mar 5 23:47:15 2012 keikoConfigurationLSCND2 at REFL OSAND filter ND3 (which is at the   
  6361   Tue Mar 6 00:13:20 2012 keikoUpdateLSCASI signal offset   Screenshot-Untitled_Window.png 
  6368   Tue Mar 6 23:37:31 2012 keikoUpdateSUSMICH noise budget - SUS checkHere are the OSEM spectrum of MICH suspensions
(BS, IX, IY). Bounce and Roll modes are shown
on 16 and 23 Hz. The filters for them has
 6x 
  6375   Wed Mar 7 16:32:09 2012 keikoUpdateLSCOSA I swap an OSA at PSL and OSA at REFL.
It was because the PSL-OSA had a better resolution,
so we place this better one at REFL. The
  
  6376   Wed Mar 7 17:39:40 2012 keikoUpdateLSCMICH noise budget on 5 Mar This is the calibrated MICH noise
budget on Mar 5. There was a sharp peak at
1Hz and a blob on 3 Hz. The demod phase was
 Mar5-MICHbudget.pngMar5-MICHbudget.png 
  6380   Wed Mar 7 20:53:13 2012 keikoUpdateLSCMICH noise budget on 5 Mar 
 
 Mar6-MICHbudget.png 
  6384   Wed Mar 7 23:29:28 2012 keikoUpdateLSCREFL OSA observation kiwamu, keiko
 
 
 REFLOSA.png 
  6385   Thu Mar 8 00:57:48 2012 keikoUpdateLSCMICH noise budget on Mar 5, Mar 6, and oldHere is the recent two noise budgets of
MICH, with the old measurement by Jenne.
The most latest Mar 6 data is quite close
 Mar7MICHbudgettotal.png 
  6393   Fri Mar 9 13:34:13 2012 keikoUpdateLSCupdate on the locking activityWe tried to measure the sensing matrix
for MICH and PRCL last night. They look too
much mixed as we expect... the matrix may
  
  6398   Sat Mar 10 02:00:03 2012 keikoUpdateLSCupdate on the locking activityITMX and ITMY balance for the MICH excitation
(lockin) is adjusted again. Now it's ITMx
= -0.992, ITMy = 1 for MICH (lockin output
  
  6400   Mon Mar 12 01:04:18 2012 keikoUpdateLSCRAM simulation update, RAM LSC matrix I calculated the DRMI RAM LSC
matrix with RAM and the operation point offsets.

    configuration: C1 DRMI
  
  6401   Mon Mar 12 18:57:58 2012 keikoUpdateLSCRAM simulation update, RAM LSC matrix

    

       
            
  
  6417   Wed Mar 14 16:33:20 2012 keikoUpdateLSCRAM simulation / RAM pollution plotIn the last post, I showed that SRCL element
in the MICH sensor (AS55I-mich) is chaned
1% due to RAM.
 Mar14pollution.pngRAMexampleplot.png 
  6419   Wed Mar 14 21:01:36 2012 keikoUpdateLSCevolution of the sensing matrix in PRMI as a function of timeThis is the simulated signals
to compare with the original post #6403
  
  6449   Tue Mar 27 02:18:31 2012 keikoUpdateIOOBeam Profile measurement: IPPOS beamKeiko, Rana, Suresh
Related to the beam profile of IPPOS
today, we tried to measure the beam size
 text9149.pngfirst_cap.pngsecond_cap.pngtext9149.png 
  6452   Tue Mar 27 16:06:59 2012 keikoUpdateIOOBeam Profile measurement: IPPOS beamI changed the ETMY CCD camera angle
so that we can see the suspension frame in
order to repeat the same thing as yesterday.
  
  6458   Tue Mar 27 21:37:51 2012 keikoConfigurationIOOBeam Profile measurement: IPPOS beam From the mode measurement I and Suresh
have done yesterday, I calculated what beam
size we expect at ETM ((1) upper Fig.1)  and
 9x 
  6464   Thu Mar 29 11:29:27 2012 keikoUpdateLSCPOP22/POP110 amplifiresYesterday I and Kiwamu connected two amplifiers
(mini-circuit, ZFL-1000LNB+) for POP22/110.
Dataviewer can see some signals. I'll test
  
  6466   Thu Mar 29 18:42:11 2012 keikoUpdateLSCPOP22/POP110 amplifiresAdding two amplifiers on POP22/110,
I checked the signals going to the dmod board
of 22 and 110.
 P3290004.JPGP3290005.JPG 
ELOG V3.1.3-