Fri Aug 19 15:36:10 2022, Koji, Update, General, SR785 C21593 CHA+ BNC broken 
|
Wed Aug 17 01:18:54 2022, Koji, Update, General, Notice: SURF SUS test setup blocking the lab way
|
Fri Aug 19 15:20:14 2022, Koji, Update, General, Notice: SURF SUS test setup blocking the lab way
|
Wed Aug 17 07:35:48 2022, yuta, Bureaucracy, General, My wish list for IFO commissioning
|
Fri Aug 19 14:46:32 2022, Anchal, Update, SUS, Open loop transfer function measurements for local damping loops of BHD optics
|
Fri Jul 1 08:50:48 2022, yuta, Summary, LSC, FPMI with REFL/AS55 trial
|
Thu Jul 14 00:10:08 2022, yuta, Summary, LSC, FPMI with REFL/AS55 trial continued   
|
Fri Jul 15 19:13:22 2022, Paco, Summary, LSC, FPMI with REFL/AS55 demod phase adjust
|
Fri Jul 15 22:36:04 2022, rana, Summary, LSC, FPMI with REFL/AS55 demod phase adjust
|
Mon Jul 18 16:39:07 2022, Paco, Summary, LSC, FPMI locking procedure using REFL55 and AS55   
|
Mon Jul 18 21:41:42 2022, Anchal, Summary, LSC, FPMI locking procedure using REFL55 and AS55
|
Tue Aug 9 19:54:31 2022, yuta, Summary, LSC, FPMI locking tonight
|
Thu Aug 18 14:49:35 2022, Yehonathan, Summary, LSC, FPMI Sensitivity
|
Thu Aug 18 18:10:49 2022, Koji, Summary, LSC, FPMI Sensitivity
|
Thu Aug 18 16:35:29 2022, Cici, Update, General, UGF linked to optical gain! 
|
Thu Aug 4 19:01:59 2022, Tega, Update, Computers, Front-end machine in supermicro boxes   
|
Mon Aug 8 17:16:51 2022, Tega, Update, Computers, Front-end machine setup
|
Wed Aug 10 20:51:14 2022, Tega, Update, Computers, CDS upgrade Front-end machine setup 
|
Tue Aug 16 18:22:59 2022, Tega, Update, Computers, c1teststand rack mounting for CDS upgrade 
|
Wed Aug 17 11:10:51 2022, rana, Update, Computers, c1teststand rack mounting for CDS upgrade
|
Wed Aug 17 10:27:49 2022, Cici, Update, General, Locking X-arm AUX laser 
|
Mon Aug 15 10:27:56 2022, Koji, Update, General, Recap of the additional measures for the outage prep    
|
Mon Aug 15 15:43:49 2022, Anchal, Update, General, Complete power shutdown and startup documentation
|
Mon Aug 15 18:06:07 2022, Anchal, Update, General, c1vac issues, 1 pressure gauge died
|
Mon Aug 15 20:09:18 2022, Koji, Update, General, c1vac issues, 1 pressure gauge died
|
Wed Aug 17 10:23:05 2022, Tega, Update, General, c1vac issues, pressure gauge replacement
|
Fri Aug 12 13:40:36 2022, JC, Update, General, Preparing for Shutdown on Saturday, Aug 13
|
Fri Aug 12 02:02:31 2022, Koji, Update, General, Power Outage Prep: nodus /home/export backup
|
Thu Aug 11 17:15:33 2022, Cici, Update, General, Measuring AUX Laser UGF with Red Pitaya 
|
Wed May 20 20:10:34 2020, rana, John Z, Update, Computer Scripts / Programs, NDS2 server / conf updated - seems OK now
|
Thu May 21 15:31:26 2020, gautam, Update, Computer Scripts / Programs, NDS2 service restarted
|
Fri May 22 10:37:41 2020, rana, Update, Computer Scripts / Programs, NDS2 service restarted
|
Mon May 25 10:54:41 2020, rana, Update, Computer Scripts / Programs, NDS2 service restarted
|
Thu Aug 11 16:48:59 2022, rana, Update, Computer Scripts / Programs, NDS2 updates
|
Wed Aug 10 20:30:54 2022, Tega, Summary, SUS, Characterisation of suspension damping 12x
|
Wed Aug 10 19:36:45 2022, Koji, Bureaucracy, General, Lab cleaning and discovery   
|
Wed Aug 10 15:33:59 2022, Cici, Update, General, Working Red Pitaya VNA
|
Wed Aug 10 19:24:19 2022, rana, Update, General, Working Red Pitaya VNA
|
Tue Jul 19 18:41:42 2022, yuta, Update, BHD, Contrast measurements for Michelson and ITM-LO
|
Wed Jul 20 18:07:52 2022, Paco, Update, BHD, BHD MICH test
|
Tue Jul 26 20:54:08 2022, Paco, Update, BHD, BHD MICH test - LO phase control
|
Wed Jul 27 18:30:50 2022, yuta, Update, BHD, LO beam power at BHD DCPDs is significantly lower than expected 
|
Thu Jul 28 14:34:40 2022, Yehonathan, Update, BHD, LO beam power at BHD DCPDs is significantly lower than expected
|
Thu Jul 28 16:51:55 2022, Tega, Update, BHD, Shaking test for LO beam AS beam to BHD DCPDs 
|
Thu Jul 28 20:16:26 2022, Anchal, Update, BHD, Shaking test for LO beam AS beam to BHD DCPDs
|
Fri Jul 29 18:24:53 2022, Tega, Update, BHD, LO beam power improved by factor of 6 after LO and AS beam alignment   
|
Wed Aug 3 16:00:51 2022, yuta, Update, BHD, BHD fringe aligned with reduced LO and AS beam clipping
|
Tue Aug 9 15:33:12 2022, yuta, Update, BHD, BHD fringe contrast improved from 43% to 74%   
|
Tue Aug 9 15:50:22 2022, Koji, Update, BHD, BHD fringe contrast improved from 43% to 74%
|
Fri Jul 29 20:21:11 2022, Koji, Update, PSL, FSSSlow/MCAutolocker issue (docker)
|
Sat Jul 30 10:38:12 2022, Anchal, Update, PSL, FSSSlow/MCAutolocker issue (docker)
|
Sat Jul 30 12:48:18 2022, Koji, Update, PSL, FSSSlow/MCAutolocker issue (docker)
|
Thu Aug 4 11:28:22 2022, Anchal, Update, PSL, FSSSlow/MCAutolocker issue (docker)
|
Mon Aug 8 14:47:10 2022, rana, Update, PSL, FSSSlow/MCAutolocker issue (docker)
|
Wed Jul 20 11:58:45 2022, Paco, Summary, General, Jenne laser kaput?
|
Wed Jul 20 14:12:07 2022, Paco, Summary, General, Jenne laser kaput!
|
Wed Jul 20 15:58:52 2022, Koji, Summary, General, Jenne laser kaput!
|
Mon Jul 25 09:05:50 2022, Paco, Summary, General, Testing 950nm laser found in trash pile 
|
Fri Aug 5 17:03:31 2022, Yehonathan, Summary, General, Testing 950nm laser found in trash pile 
|
Fri Jul 29 22:37:54 2022, Koji, Update, IOO, WFS investigation 
|
Tue Aug 2 01:10:26 2022, Koji, Update, IOO, WFS investigation   
|
Thu Aug 4 21:58:18 2022, Koji, Update, IOO, WFS investigation   
|
Thu Aug 4 22:14:20 2022, Koji, Update, IOO, WFS investigation   
|
Thu Aug 4 22:14:38 2022, Koji, Update, IOO, WFS investigation 
|
Thu Aug 4 22:32:31 2022, Koji, Update, IOO, Upon leaving the lab (WFS investigation)
|
Fri Aug 5 12:42:12 2022, Koji, Update, IOO, IMC WFS: Overnight observation
|
Wed Aug 3 15:01:13 2022, Koji, Update, General, Borrowed Dsub cables
|
Wed May 25 16:56:44 2022, Paco, Configuration, BHD, IFO recovery - IMC alignment
|
Wed May 25 17:34:47 2022, yuta, Configuration, BHD, IFO recovery - IFO alignment
|
Thu May 26 19:55:43 2022, yuta, Configuration, BHD, Oplevs centered, BHD DCPDs are now online    
|
Fri May 27 17:45:53 2022, yuta, Configuration, BHD, BHD camera installed, GRY aligned
|
Thu Jun 2 20:05:37 2022, yuta, Configuration, PSL, IMC input power recovered to 1W, some alignment works 
|
Fri Jun 3 12:13:58 2022, Paco, Configuration, CDS, Fix RFM channels
|
Fri Jun 3 15:22:51 2022, yuta, Update, LSC, Both arms locked with POY/POX, IR beam centered on TMs with ASS 
|
Fri Jun 3 17:42:50 2022, yuta, Update, LSC, MICH locks with AS55_Q
|
Sun Jun 5 19:46:40 2022, Paco, Update, LSC, Fixed IMC Trans sum issue
|
Mon Jun 6 13:35:11 2022, Paco, Update, LSC, First calibrated spectra of MICH at AS55 Q 
|
Fri Jun 17 16:22:21 2022, yuta, Update, LSC, Actuator calibration of BS. ITMX, ITMY, updated MICH displacement spectra from c1cal 6x
|
Thu Jul 7 18:18:19 2022, yuta, Update, LSC, Actuator calibration of ETMX and ETMX  
|
Thu Jul 7 18:22:12 2022, yuta, Update, LSC, Actuator calibration of MC2 using Yarm 
|
Fri Jul 8 16:18:35 2022, rana, Update, LSC, Actuator calibration of MC2 using Yarm
|
Mon Jul 18 17:07:12 2022, yuta, Update, LSC, x4.12 added to ETMX coil outputs to balance with ETMY
|
Thu Jun 16 18:23:15 2022, Paco, Configuration, BHD, Recovering LO beam in BHD DCPDs
|
Tue Jun 21 14:17:50 2022, yuta, Configuration, BHD, BHD DCPDs re-routed to c1sus2 
|
Tue Jul 19 16:00:34 2022, yuta, Configuration, BHD, Fast channels for BHD DCPDs now available in c1lsc but not in c1hpc  
|
Thu Jul 21 21:50:47 2022, Tega, Configuration, BHD, c1sus2 IPC update
|
Fri Jul 22 15:05:26 2022, Tega, Configuration, BHD, c1sus2 shared memory and ADC fix   
|
Fri Jul 22 17:46:10 2022, yuta, Configuration, BHD, c1sus2 watchdog update and DCPD ERR channels
|
Mon Jul 25 17:58:10 2022, Tega, Configuration, BHD, c1sus2 IPC dolphin issue update   
|
Mon Aug 1 18:42:39 2022, Tega, Configuration, BHD, c1sus2 IPC dolphin issue update  
|
Tue Aug 2 17:25:18 2022, Tega, Configuration, BHD, c1sus2 dolphin IPC issue solved 
|
Mon Jul 25 18:09:41 2022, Tega, Configuration, BHD, BHD Homodyne Phase control MEDM screen 
|
Mon Aug 1 17:19:39 2022, Cici, Summary, General, RPitaya Data on Jupyter Notebook
|
Wed Jul 13 17:30:19 2022, Koji, Update, CDS, Too huge script_archive
|
Thu Jul 28 15:11:59 2022, Koji, Update, CDS, Too huge script_archive
|
Thu Jul 28 13:09:28 2022, yehonathan, Update, BHD, Mode matching considerations
|
Wed Jul 27 14:39:04 2022, Deeksha, Update, Electronics, New and improved PZT TF data from the DFD  
|
Tue Jul 26 19:50:25 2022, Deeksha, Update, Computer Scripts / Programs, Vector fitting 
|
Tue Jul 26 21:16:41 2022, Koji, Update, Computer Scripts / Programs, Vector fitting
|
Mon Jul 25 18:22:30 2022, Deeksha, Summary, Wiki, Measured the PZT TF Successfully 6x
|
Mon Jul 25 09:37:39 2022, Deeksha, Update, Electronics, Using the DFD to measure PZT TF 
|
Mon Jul 18 04:42:54 2022, Anchal, Update, Calibration, Error propagation to astrophysical parameters from detector calibration uncertainty   
|
Mon Jul 18 15:17:51 2022, Hang, Update, Calibration, Error propagation to astrophysical parameters from detector calibration uncertainty
|
Tue Jul 19 07:34:46 2022, Anchal, Update, Calibration, Error propagation to astrophysical parameters from detector calibration uncertainty   
|
Sun Jul 24 08:56:01 2022, Hang, Update, Calibration, Error propagation to astrophysical parameters from detector calibration uncertainty
|
Fri Jul 22 17:43:19 2022, Koji, Update, General, Obtained a functional CRT
|
Tue Jul 19 17:18:34 2022, JC, Update, Electronics, New Coil Driver on Rack 1X3
|
Mon Jul 11 11:56:40 2022, he Yehonathan, Update, BHD, MICH AS55 noise budget 
|
Tue Jul 12 09:14:50 2022, rana, Update, BHD, MICH AS55 noise budget
|
Wed Jul 13 10:54:39 2022, Yehonathan, Update, BHD, MICH AS55 noise budget  
|
Wed Jul 13 13:30:48 2022, Yehonathan, Update, BHD, add Laser RIN to MICH budget
|
Mon Jul 18 16:49:57 2022, Yehonathan, Update, BHD, add Laser RIN to MICH budget 
|
Mon Jul 18 18:33:38 2022, Koji, Update, BHD, add Laser RIN to MICH budget
|
Sat Jul 16 02:44:10 2022, Koji, Update, IOO, IMC servo tuning  
|
Fri Jul 15 16:20:16 2022, Cici Hanna, Update, General, Finding UGF   
|
Wed Jul 13 07:16:48 2022, JC, Update, Electronics, Checking Sorensen Power Supplies 
|
Fri Jul 15 12:21:58 2022, JC, Update, Electronics, Checking Sorensen Power Supplies 
|
Thu Jul 14 19:56:15 2022, rana, Update, IOO, mc wfs demod
|
Thu Jul 14 19:09:51 2022, rana, Update, General, EQ recovery
|
Wed Jul 13 18:58:17 2022, Koji, Update, IOO, IMC suspecion
|
Tue Jul 12 14:56:17 2022, Tomislav, Summary, Electronics, Electronics noise measurements 23x
|
Wed Jul 13 13:26:44 2022, rana, Summary, Electronics, Electronics noise measurements
|
Wed Jul 13 12:49:25 2022, Paco, Summary, SUS, SUS frozen
|
Tue Jul 12 19:46:54 2022, Paco, Summary, ALS, How (not) to take NPRO PZT transfer function
|
Tue Jul 12 18:35:31 2022, Cici Hanna, Summary, General, Finding Zeros/Poles With Vectfit
|
Tue Jul 12 13:59:12 2022, rana, Summary, Computers, process monitoring: Monit
|
Tue Jul 12 09:25:09 2022, rana, Update, IOO, IMC WFS
|
Mon Jul 11 19:29:23 2022, Paco, Summary, General, Finalizing recovery -- timing issues, cds, MC1
|
Mon Jul 11 15:26:12 2022, JC, HowTo, VAC, Startup after Power Outage
|
Mon Jul 11 17:41:52 2022, Koji, HowTo, VAC, Startup after Power Outage
|
Tue Apr 12 09:05:21 2022, Jordan, Update, VAC, New Pressure Gauge Install/Pump Spool Vent 6x
|
Wed Apr 13 12:50:07 2022, Tega, Update, VAC, New Pressure Gauge Install/Pump Spool Vent
|
Thu Apr 21 16:36:56 2022, Tega, Update, VAC, cleanup work for vacuum git repo
|
Tue May 24 10:37:09 2022, Tega, Update, VAC, added FRG channels to slow channel ini file
|
Mon Jul 11 17:25:43 2022, Tega, Update, VAC, fixed obsolete reference bug in serial_XGS600 service
|
Mon Jul 11 11:16:45 2022, JC, Summary, Electronics, Startup after Shutdown
|
Fri Jul 8 23:10:04 2022, Koji, Summary, General, July 9th, 2022 Power Outage Prep
|
Fri Jul 8 14:03:33 2022, JC, HowTo, VAC, Vacuum Preparation for Power Shutdown
|
Wed Sep 29 17:10:09 2021, Anchal, Summary, CDS, c1teststand problems summary
|
Thu Sep 30 14:09:37 2021, Anchal, Summary, CDS, New way to ssh into c1teststand
|
Thu Mar 3 15:37:40 2022, Anchal, Summary, CDS, c1teststand restructured
|
Mon Oct 4 11:05:44 2021, Anchal, Summary, CDS, c1teststand problems summary
|
Mon Oct 4 18:00:16 2021, Koji, Summary, CDS, c1teststand problems summary
|
Tue Oct 5 17:58:52 2021, Anchal, Summary, CDS, c1teststand problems summary
|
Tue Oct 5 18:00:53 2021, Anchal, Summary, CDS, c1teststand time synchronization working now
|
Mon Oct 11 17:31:25 2021, Anchal, Summary, CDS, Fixed mounting of mx devices in fb. daqd_dc is running now.
|
Mon Oct 11 18:29:35 2021, Anchal, Summary, CDS, Moving forward?
|
Tue Oct 12 17:20:12 2021, Anchal, Summary, CDS, Connected c1sus2 to martian network
|
Tue Oct 12 23:42:56 2021, Koji, Summary, CDS, Connected c1sus2 to martian network
|
Wed Oct 13 11:25:14 2021, Anchal, Summary, CDS, Ran c1sus2 models in martian CDS. All good!
|
Tue Oct 19 18:20:33 2021, Ian MacMillan, Summary, CDS, c1sus2 DAC to ADC test 
|
Tue Oct 19 23:43:09 2021, Koji, Summary, CDS, c1sus2 DAC to ADC test   
|
Wed Oct 20 11:48:27 2021, Anchal, Summary, CDS, Power supple configured correctly.
|
Tue Oct 26 18:24:00 2021, Ian MacMillan, Summary, CDS, c1sus2 DAC to ADC test 
|
Wed Dec 22 17:40:22 2021, Anchal, Summary, CDS, c1su2 model updated with SUS damping blocks for 7 SOSs
|
Wed Dec 29 20:09:40 2021, rana, Summary, CDS, c1su2 model updated with SUS damping blocks for 7 SOSs
|
Fri Mar 4 11:04:34 2022, Anchal, Summary, CDS, c1susaux2 system setup and running
|
Mon Mar 7 19:38:47 2022, Anchal, Summary, CDS, c1susaux2 slow controls issues
|
Mon Mar 14 12:20:05 2022, Anchal, Summary, CDS, c1susaux2 slow controls acromag chassis installed 
|
Thu Mar 17 19:12:44 2022, Anchal, Summary, CDS, c1auxey1 slow controls acromag chassis installed, not powered
|
Fri Mar 18 18:39:13 2022, Yehonathan, Summary, CDS, c1auxey1 slow controls acromag chassis installed, powered
|
Fri Mar 18 19:10:51 2022, Anchal, Summary, CDS, c1auxey1 slow controls issues
|
Mon Mar 21 18:42:06 2022, Anchal, Summary, CDS, c1auxey1 slow controls issues
|
Mon Apr 4 17:03:47 2022, Anchal, Summary, CDS, c1susaux2 slow controls acromag chassis fixed and installed
|
Wed Jul 6 22:40:03 2022, Tega, Summary, CDS, Use osem variance to turn off SUS damping instead of coil outputs
|
Thu Jul 7 21:25:48 2022, Tega, Summary, CDS, Use osem variance to turn off SUS damping instead of coil outputs
|
Tue Mar 15 11:52:34 2022, Anchal, Summary, CDS, c1su2 model updated for sending Run/Acquire Binary Output to Binary Interface card
|
Tue Mar 15 14:10:41 2022, Anchal, Summary, CDS, c1su2 model remade, reinstalled, restarted after the update
|
Tue Oct 12 17:10:56 2021, Anchal, Summary, CDS, Some more information
|
Wed Jul 6 19:58:16 2022, Paco, Summary, NoiseBudget, XARM noise budget
|
Wed Jul 6 18:51:20 2022, Deeksha, Update, Electronics, Measuring the Transfer Function of the PZT  
|
Wed Jul 6 15:28:18 2022, Tega, Update, SUS, Output matrix diagonalisation : F2P coil balancing
|
Tue Jul 5 20:05:06 2022, Tomislav, Update, Electronics, Whitening electronics noise
|
Fri Jul 1 12:49:52 2022, Koji, Update, IOO, MC2 seemed misaligned / fixed 
|
Thu Jun 30 19:24:24 2022, rana, Summary, PEM, effect of nearby CES construction
|
Thu Jun 30 18:06:22 2022, Paco, Update, ALS, Optimum ALS recovery - part I
|
Thu Jun 30 19:04:55 2022, rana, Summary, PSL, PSL HEPA: How what when why
|
Thu Jun 30 17:19:55 2022, Deeksha, Summary, Electronics, Measured Transfer Functions of the Control Loop, Servo (OLTF); got Vectfit working  
|
Tue Jun 28 18:19:09 2022, Tomislav, Update, Electronics, Electronics noise 
|
Wed Jun 29 18:53:38 2022, rana, Update, Electronics, Electronics noise
|
Tue Jun 28 16:59:35 2022, Paco, Summary, ALS, ALS beat allan deviation (XARM) 
|
Tue Jun 28 18:53:16 2022, rana, Summary, ALS, ALS beat allan deviation (XARM)
|
Wed Jun 29 14:28:06 2022, Paco, Summary, ALS, ALS beat allan deviation (XARM)
|
Tue Jun 28 23:10:34 2022, Yehonathan, Update, BHD, Measurement of AS55 demod board conversion factor
|
Tue Jun 28 22:27:11 2022, Yehonathan, Update, BHD, Measurement of input and output electronics noise 
|
Tue Jun 28 17:07:47 2022, Anchal, Update, Calibration, Added Beatnote channels in demodulation of c1cal
|
Tue Jun 28 16:26:58 2022, Cici, Summary, General, Vector fitting open loop transfer function/Audio cancellation of optical table enclosure   
|
Tue Jun 21 21:17:16 2022, yuta, Update, BHD, RTS models for BHD added but PCIE error remaining   
|
Wed Jun 22 14:44:03 2022, Anchal, Update, BHD, Fixed DC error in c1su2, added new library model for suspensions
|
Tue Jun 28 14:24:23 2022, yuta, Update, BHD, BHD DC PD signals now also sent to c1lsc to circumvent IPC error  
|
Tue Jun 28 09:03:58 2022, JC, Update, General, Organizing and Cleaning
|
Mon Jun 27 18:54:27 2022, yuta, Update, LSC, Modulation depths measurement using Yarm cavity scan
|
Mon Jun 27 13:39:40 2022, Deeksha, Update, Electronics, Setting up the MokuLab
|
Mon Jun 27 13:25:50 2022, Cici, Update, General, Characterizing the Transfer Loop   
|
Fri Jun 24 12:13:16 2022, JC, Update, IOO, WFS issues
|
Sat Jun 25 14:29:48 2022, Anchal, Update, IOO, WFS issues
|
Sat Jun 25 20:23:59 2022, Koji, Update, IOO, WFS issues 
|
Mon Jun 27 12:32:45 2022, yuta, Update, IOO, WFS issues fixed
|
Sat Jun 25 22:18:41 2022, Tomislav, Update, ASC, Simulation and reality comparisons  
|
Fri Jun 24 17:16:59 2022, Paco, Update, ALS, XAUX cable in control room
|
Tue May 4 19:14:43 2021, Yehonathan, Update, General, OSEMs from KAGRA
|
Fri Jun 24 13:29:37 2022, Yehonathan, Update, General, OSEMs from KAGRA
|
Thu Jun 23 15:05:01 2022, Water Monitor, Update, Upgrade, Water Bottle Refill
|
Wed Jun 22 18:55:31 2022, yuta, Update, LSC, Daily alignment work; POY trouble solved 
|
Wed Jun 22 19:41:13 2022, Koji, Update, LSC, Daily alignment work; POY trouble solved
|
Wed Jun 22 17:04:06 2022, Deeksha, Summary, Electronics, Characterising the AUX control loop  
|
Tue Jun 21 22:22:37 2022, Tomislav, Update, ASC, Plots
|
Tue Jun 21 18:41:46 2022, Tomislav, Update, ASC, Simulation plot
|
Tue Jun 21 14:59:22 2022, Cici, Summary, General, AUX Transfer Function Loop Exploration
|
Tue Jun 14 18:45:43 2022, Anchal, Update, SUS, LO2 lower magnets are stuck in coil, won't come off
|
Tue Jun 14 19:34:06 2022, yuta, Update, SUS, Resonant frequency identification from the free swing test 7x
|
Thu Jun 16 18:30:07 2022, Anchal, Update, SUS, New diagonalized input matrices applied
|
Tue Jun 21 08:36:50 2022, Anchal, Update, SUS, Diagonalized input matrices for LO1, freeSwing on ITMY and ITMX
|
Wed Jun 15 15:07:07 2022, Koji, Update, SUS, LO2 SUS stuck fixed 
|
Mon Jun 20 19:46:04 2022, Tomislav, Update, ASC, Simulation plots    
|
Thu Apr 7 11:47:22 2022, Yehonathan, Update, BHD, Initial BHD modeling: AS - LO mode matching
|
Thu Apr 7 21:15:04 2022, Yehonathan, Update, BHD, Initial BHD modeling: AS - LO mode matching
|
Mon May 16 16:13:01 2022, Yehonathan, Update, BHD, Initial BHD modeling: Damped suspension model  
|
Thu Jun 16 17:40:15 2022, Yehonathan, Update, BHD, Comparison of MICH OLTF model with measurement
|
Fri Jun 17 12:05:32 2022, Yehonathan, Update, BHD, Comparison of MICH OLTF model with measurement
|
Fri Jun 17 13:07:08 2022, Koji, Update, BHD, Comparison of MICH OLTF model with measurement
|
Thu Jun 16 19:49:48 2022, Cici, Update, General, Using the SR785
|
Wed Jun 15 15:03:41 2022, Koji, Update, PSL, PMC input beam aligned 
|
Thu Jun 16 15:29:03 2022, yuta, Update, PSL, PMC input beam aligned again, IMC
|
Wed Jun 15 17:12:39 2022, Cici, Summary, General, Preparation for AUX Loop Characterization
|
Tue May 24 11:04:53 2022, JC, Update, VAC, Beginning Pumpdown 
|
Wed May 25 16:38:27 2022, yuta, Update, SUS, Suspensions quick health check 
|
Tue Jun 7 17:26:21 2022, yuta, Update, SUS, ITMY ULCOIL mystery not solved  
|
Tue Jun 7 19:13:12 2022, yuta, Update, SUS, Agreement on suspension damping loop polarity conventions
|
Fri Jun 10 15:02:04 2022, yuta, Update, SUS, Servo gain sign flipped for MC1 WFS relief
|
Tue Jun 7 19:40:45 2022, Anchal, Update, SUS, ITMY changed output matrix to disable use of UL coil 
|
Wed Jun 8 18:16:20 2022, yuta, Update, SUS, ITMY ULCOIL mystery: Coil driver swap test 
|
Thu Jun 9 23:08:39 2022, rana, Update, SUS, ITMY ULCOIL mystery: Coil driver swap test
|
Fri Jun 10 13:02:14 2022, yuta, Update, SUS, ITMY ULCOIL mystery: Coil driver swap test
|
Fri Jun 10 15:04:23 2022, rana, Update, SUS, ITMY ULCOIL mystery: Coil driver swap test
|
Fri Jun 10 21:10:01 2022, yuta, Update, SUS, ITMY ULCOIL mystery: Coil driver swap test
|
Wed Jun 15 17:03:17 2022, yuta, Update, SUS, ITMY ULCOIL issue solved, loose connection in sat amp box   
|
Wed Jun 15 15:45:37 2022, yuta, Update, SUS, LO1 LLCOIL now working, it was loose connection  
|
Wed Jun 15 07:26:35 2022, JC, Update, VAC, Beginning Pumpdown
|
Fri Jun 10 20:11:46 2022, yuta, Update, ASC, Yarm ASS re-tuning in progress
|
Mon Jun 13 20:26:09 2022, yuta, Update, ASC, Yarm ASS re-tuning in progress -part 2- 
|
Tue Jun 14 20:57:15 2022, Anchal, Update, ASC, Yarm ASS working now
|
Tue Jun 14 08:41:36 2022, JC, Update, OPLEV Tables, BS Oplev Table Sketch
|
Fri Jun 10 13:52:22 2022, JC, Update, OPLEV Tables, ITMX, ITMY, and Vertex Table Beam Paths  
|
Wed Jun 8 16:57:46 2022, Koji, Update, IOO, Power Outage 220608: IMC restored
|
Wed Jun 8 16:33:26 2022, Koji, Update, General, Power Outage 220608: HVAC restored
|
Wed Jun 8 16:03:12 2022, Koji, Update, VAC, Power Outage 220608: Vacuum Recovery
|
Tue Jun 7 18:32:46 2022, Deeksha, Update, Electronics, Noise Budgeting ADC (of redpitaya) 
|
Mon Jun 6 21:01:22 2022, yuta, Update, IMC, MC1 OSEM sensor sign flipped, MC1/2/3 free swinging overnight for inmat diagonalization
|
Mon Jun 6 22:08:55 2022, Koji, Update, IMC, MC1 OSEM sensor sign flipped, MC1/2/3 free swinging overnight for inmat diagonalization
|
Mon Jun 6 16:09:23 2022, rana, Configuration, DetChar, Summary Pages: seis BLRMS
|
Mon Jun 6 09:37:16 2022, JC, Update, SUS, InMatCalc
|
Wed Jun 1 12:56:44 2022, Paco, Summary, Electronics, STEMlab 125 handout
|
Tue May 31 17:30:01 2022, Yehonathan, Update, BHD, Green shutters fixed
|
Wed Jun 1 11:56:28 2022, yuta, Update, ALS, Shutter driver for GRY replaced
|
Fri May 27 12:15:30 2022, JC, Update, Electronics, CRT TV / Monitor 6
|
Tue May 31 14:44:02 2022, JC, Update, Electronics, CRT TV / Monitor 6
|
Fri May 27 17:46:48 2022, Paco, Summary, Computers, CDS upgrade visit, downfall and rise of c1lsc models
|
Mon May 16 14:46:35 2022, Tommy, Update, Electronics, RFSoC MTS Work
|
Fri May 27 15:53:17 2022, Tommy, Update, Electronics, RFSoC MTS Work
|
Thu May 26 15:55:10 2022, Tommy, Update, Electronics, RFSoC Power Spectrum
|
Tue May 3 21:05:23 2022, yuta, Update, BHD, AS path alignment, removing a lot of green stuff 7x
|
Wed May 4 13:09:42 2022, Anchal, Update, BHD, IMC table balanced again, IMC is locking, YARM is locking
|
Wed May 4 15:08:59 2022, Tega, Update, BHD, XARM alignment to get flashing
|
Wed May 4 18:52:43 2022, Tega, Update, BHD, POP beam too high at POP SM4 on the ITMX chamber
|
Thu May 5 14:46:22 2022, Anchal, Update, BHD, POP beam height lowered, POP_SM4 raised
|
Thu May 5 17:05:31 2022, Tega, Update, BHD, IMC & X/Y-arm alignment
|
Mon May 9 18:43:03 2022, Anchal, Update, BHD, ITMX table layout corrected
|
Mon May 9 18:49:05 2022, Tega, Update, BHD, Relocate green TRX and TRY PDs/cams/optics from PSL table to BS table 
|
Tue May 10 15:46:38 2022, JC, Update, BHD, Relocate green TRX and TRY components from PSL table to BS table 
|
Tue May 10 18:25:43 2022, Paco, Update, BHD, Green Transmission path
|
Tue May 10 16:31:14 2022, Tega, Update, BHD, ITMX optlev return beam steered to QPD
|
Fri May 6 13:48:34 2022, Anchal, Update, BHD, WFS loop instability fixed
|
Thu May 12 19:55:01 2022, Tega, Update, BHD, AS path alignment 
|
Thu May 12 20:11:18 2022, Anchal, Update, BHD, BHDBS Output beams steered out to ITMY table
|
Thu May 12 20:24:29 2022, yuta, Update, BHD, POX and POY investigation
|
Mon May 16 13:22:59 2022, yuta, Update, BHD, REFL and AS paths aligned at AP table 
|
Mon May 16 19:14:17 2022, Anchal, Update, BHD, Camera set on AS path and BHDBS output path
|
Tue May 17 18:43:38 2022, Anchal, Update, BHD, Placed SRM in ITMY Chamber
|
Wed May 18 08:30:29 2022, Paco, Update, BHD, SRM OpLev
|
Thu May 19 08:51:40 2022, Paco, Update, BHD, SRM OpLev
|
Wed May 18 09:02:52 2022, Anchal, Update, BHD, WFS1 PD centered
|
Wed May 18 17:23:15 2022, Anchal, Update, BHD, Placed PRM in BS Chamber
|
Thu May 19 18:56:08 2022, yuta, Update, BHD, Current OSEM sensor values with all the suspensions aligned
|
Thu May 19 19:05:59 2022, Anchal, Update, BHD, BS Chamber all work finished, BHD path setup
|
Fri May 20 20:03:48 2022, Paco, Update, BHD, ITMY chamber work finished - LO and AS overlapped 
|
Mon May 23 13:16:59 2022, Paco, Update, BHD, End of vent - checks  
|
Tue May 24 15:21:13 2022, Anchal, Update, BHD, Freeswing tests of new SOS started
|
Fri May 20 12:42:23 2022, Tega, Update, VAC, Door installation on the end stations
|
Sat May 14 08:36:03 2022, Chris, Update, DAQ, DAQ troubleshooting
|
Mon May 16 10:49:01 2022, Anchal, Update, DAQ, DAQ troubleshooting
|
Mon May 16 12:59:27 2022, Chris, Update, DAQ, DAQ troubleshooting 
|
Fri May 13 14:26:00 2022, JC, Update, Alignment, LO2 Beam
|
Fri May 13 18:42:13 2022, Paco, Update, Alignment, ITMX and ITMY sat amp failures
|
Thu May 12 13:46:59 2022, Jc, Update, Alignment, POP Beam
|
Thu May 12 17:20:08 2022, Paco, Update, Alignment, POP Beam on CCD
|
Wed May 11 15:49:42 2022, JC, Update, OPLEV Tables, Green Beam OPLEV Alignment
|
Mon May 9 22:19:06 2022, Koji, Update, BHD, BHD Platform Progress status 
|
Mon May 9 23:18:44 2022, Koji, Update, BHD, BHD Platform Progress status 6x
|
Mon Sep 20 15:42:44 2021, Ian MacMillan, Summary, Computers, Quantization Code Summary  
|
Wed Sep 22 14:22:35 2021, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary
|
Mon Sep 27 12:12:15 2021, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary
|
Mon Sep 27 16:03:15 2021, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary
|
Mon Sep 27 17:04:43 2021, rana, Summary, Computers, Quantization Noise Calculation Summary
|
Thu Sep 30 11:46:33 2021, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary  
|
Wed Nov 24 11:02:23 2021, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary
|
Wed Nov 24 13:44:19 2021, rana, Summary, Computers, Quantization Noise Calculation Summary
|
Tue Dec 7 10:55:25 2021, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary    
|
Fri Dec 10 13:02:47 2021, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary    
|
Mon May 9 15:32:14 2022, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary  
|
Mon Apr 18 16:09:07 2022, Yehonathan, Update, BHD, BHD Readout simulation
|
Tue May 3 21:07:17 2022, Yehonathan, Update, BHD, BHD Readout simulation
|
Thu May 5 17:50:48 2022, Yehonathan, Update, BHD, BHD Readout simulation
|
Tue Feb 1 15:33:28 2022, Koji, Summary, BHD, Optomechanics configuration for the in-vacuum aux small optics
|
Wed Feb 2 18:55:58 2022, Koji, Summary, BHD, Optomechanics configuration for the in-vacuum aux small optics
|
Wed Feb 2 21:16:23 2022, Koji, Summary, BHD, Optomechanics configuration for the in-vacuum aux small optics
|
Thu Apr 28 11:53:10 2022, Anchal, Summary, BHD, POP_SM4 and POP_SM5 Assembly
|
Tue May 3 14:02:09 2022, Anchal, Summary, BHD, Installed POP path in ITMX Chamber
|
Thu Apr 14 10:18:35 2022, Paco, Summary, BHD, 2 in oplev mirrors incompatible with LMR2V
|
Thu Apr 14 18:34:51 2022, Paco, Summary, BHD, ITMY Oplev reinstalled (Re: 2 in oplev mirrors incompatible with LMR2V)
|
Fri Apr 29 08:34:40 2022, JC, Update, VAC, RGA Pump Down
|
Tue May 3 13:18:47 2022, JC, Update, VAC, RGA Pump Down
|
Thu Apr 21 18:18:42 2022, yehonathan, Update, BHD, POX Alignment
|
Thu Apr 28 17:45:53 2022, Anchal, Update, BHD, POX Beam issues
|
Sat Apr 30 13:29:33 2022, Paco, Update, BHD, POX Beam issues --- fixed, ASL alignment on vertex chamber
|
Mon May 2 17:51:30 2022, Anchal, Update, BHD, POX Beam aligned on RFPD, YARM locked
|
Wed Apr 27 10:05:55 2022, JC, Update, Coil Drivers, Coil Drivers Update
|
Mon May 2 13:30:52 2022, JC, Update, Coil Drivers, Coil Drivers Update
|
Fri Apr 22 14:14:33 2022, Jordan, Update, VAC, TP3 Forepump tip seal replacement 
|
Mon May 2 10:00:34 2022, Jordan, Update, VAC, TP3 Forepump tip seal replacement
|
Wed Apr 27 16:28:57 2022, Anchal, Summary, BHD, BHD Upgrade - Retreiving arm cavity alignment
|
Thu Apr 28 09:12:18 2022, Anchal, Update, BHD, Restoring arm alignment
|
Thu Apr 28 18:07:04 2022, Anchal, Update, BHD, Restoring arm alignment at EOD
|
Tue Apr 26 16:23:22 2022, Tommy, Update, Electronics, RFSoC2x2 MTS
|
Mon Apr 25 18:00:03 2022, Ian MacMillan, Update, Upgrade, Cable supports update
|
Thu Apr 21 10:35:23 2022, Koji, Update, CDS, DAQ seemed down
|
Mon Apr 25 17:24:06 2022, Anchal, Update, CDS, DAQ still down
|
Tue Apr 19 18:10:10 2022, Paco, Update, BHD, Part V of BHR upgrade - POX11 path, LO path, and ITMX Oplev  
|
Wed Apr 20 08:20:22 2022, Paco, Update, BHD, Part V of BHR upgrade - PR2 weirdness
|
Wed Apr 20 18:50:03 2022, Koji, Update, BHD, Part V of BHR upgrade - PR2 weirdness
|
Thu Apr 21 16:49:01 2022, Paco, Update, BHD, Part V of BHR upgrade - BS Oplev + LO1 offset
|
Thu Apr 21 18:42:47 2022, Tega, Update, BHD, Part V of BHR upgrade - Align LO and AS beams to BHD BS
|
Thu Apr 21 20:33:31 2022, Koji, Update, BHD, AS1 UR OSEM problem localized in the chamber
|
Fri Apr 22 12:03:09 2022, Tega, Update, BHD, AS1 UR OSEM problem localized in the chamber
|
Fri Apr 22 12:15:08 2022, Anchal, Update, BHD, Cable post installation
|
Mon Apr 25 16:57:57 2022, Anchal, Update, BHD, Cable post installation
|
Mon Apr 25 14:19:51 2022, JC, Update, General, Nitrogen Tank
|
Mon Apr 25 14:49:02 2022, Koji, Update, General, Nitrogen Tank
|
Sun Apr 24 13:17:08 2022, Tommy, Update, Electronics, New RFSoC2x2 Overlay
|
Fri Apr 22 07:01:58 2022, Jc, Update, Coil Drivers, Adding Resistors and Reinstalling 8x
|
Fri Apr 22 12:09:51 2022, Anchal, Update, Coil Drivers, Please update DCC pages
|
Mon Apr 18 14:52:47 2022, Ian MacMillan, Summary, SEI, Seismic Study of Buildings and Caltech Campus 7x
|
Thu Apr 21 17:32:35 2022, Ian MacMillan, Summary, SEI, Seismic Study of Buildings and Caltech Campus 
|
Wed Apr 20 16:11:08 2022, Koji, Update, SUS, Outpur resistors updated for LO1 coil drivers / for SR2, LO2, AS1, and AS4 in progress 6x
|
Thu Apr 21 15:22:44 2022, Koji, Update, SUS, Outpur resistors updates for SR2, LO2, AS1, and AS4 done
|
Thu Apr 21 11:31:35 2022, JC, Update, VAC, Gauges P3/P4 
|
Tue Mar 1 16:01:14 2022, Paco, Update, Electronics, RFSoC 2x2 board -- setup for remote work & BALUN saga 
|
Thu Apr 7 20:33:42 2022, Tommy, Update, Electronics, RFSoC 2x2 board -- setup for remote work
|
Fri Apr 8 16:03:58 2022, rana, Update, Electronics, RFSoC 2x2 board -- setup for remote work & BALUN saga
|
Wed Apr 20 14:56:06 2022, Tommy, Update, Electronics, RFSoC 2x2 board -- setup for remote work & BALUN saga
|
Mon Apr 18 15:17:31 2022, Jancarlo, Update, General, Tool box and Work Station Organization
|
Mon Apr 18 23:22:39 2022, Koji, Update, General, Tool box and Work Station Organization
|
Mon Oct 25 13:23:45 2021, Anchal, Summary, BHD, Before photos of BSC
|
Mon Oct 25 17:37:42 2021, Anchal, Summary, BHD, Part I of BHR upgrade - Removed optics from BSC 
|
Tue Oct 26 16:56:22 2021, Paco, Summary, BHD, Part I of BHR upgrade - Locked PMC and IMC
|
Wed Oct 27 16:27:16 2021, Anchal, Summary, BHD, Part II of BHR upgrade - Prep 
|
Wed Oct 27 16:31:35 2021, Anchal, Summary, BHD, Part III of BHR upgrade - Removal of PR2 Small Suspension
|
Thu Oct 28 16:32:32 2021, Paco, Summary, BHD, Part IV of BHR upgrade - Removal of BSC eastern optics
|
Fri Nov 5 12:21:16 2021, Anchal, Summary, BHD, Part VI of BHR upgrade - Removal of ITMYC optics  
|
Wed Dec 15 16:11:38 2021, Anchal, Summary, BHD, Part VIII of BHR upgrade - Placed LO1
|
Wed Dec 15 17:44:18 2021, Koji, Summary, BHD, Part VIII of BHR upgrade - Placed LO1
|
Thu Jan 6 21:04:41 2022, Anchal, Summary, BHD, Part VIII of BHR upgrade - LO1 OSEMs inserted
|
Mon Jan 10 14:52:51 2022, Anchal, Summary, BHD, LO1 OSEMs roughly calibrated and noise measured 
|
Mon Jan 10 18:36:41 2022, Anchal, Summary, BHD, LO1 free swinging test set to trigger
|
Tue Jan 11 12:19:12 2022, Anchal, Summary, BHD, LO1 Input Matrix Diagonalization performed. 
|
Mon Jan 24 18:53:09 2022, Anchal, Summary, BHD, Part VIII of BHR upgrade - LO2 placed and OSEMs tuned
|
Tue Jan 25 10:55:02 2022, Anchal, Summary, BHD, Part VIII of BHR upgrade - LO2 input matrix diagonalization performed.
|
Tue Jan 25 16:42:03 2022, Anchal, Summary, BHD, Reduced filter gains in all damped new SOS
|
Thu Jan 6 11:54:20 2022, Anchal, Summary, BHD, Part IX of BHR upgrade - Placed AS1 and AS4
|
Fri Jan 7 16:17:42 2022, Anchal, Summary, BHD, Part IX of BHR upgrade - Placed AS1 and AS4 filters
|
Sat Jan 8 16:01:42 2022, Paco, Summary, BHD, Part IX of BHR upgrade - Placed LO2 filters
|
Tue Jan 18 14:26:09 2022, Paco, Summary, BHD, Part IX of BHR upgrade - Placed remaining filters SR2, PR3, PR2
|
Tue Jan 11 18:18:29 2022, Anchal, Summary, BHD, Attempted OSEM installation on AS1
|
Tue Jan 11 18:40:25 2022, Anchal, Summary, BHD, AS1 Sat Amp has a PCB issue
|
Thu Jan 13 09:48:41 2022, Anchal, Summary, BHD, AS1 Sat Amp fixed 
|
Thu Jan 13 12:24:08 2022, Anchal, Summary, BHD, AS1 SD and LR magnets broke
|
Mon Jan 24 21:18:40 2022, Paco, Summary, BHD, Part IX of BHR upgrade - AS1 placed and OSEM tuned
|
Tue Jan 25 11:02:54 2022, Anchal, Summary, BHD, Part IX of BHR upgrade - AS1 free swing test failed
|
Thu Jan 27 08:27:34 2022, Paco, Summary, BHD, Part IX of BHR upgrade - AS1 inspection and correction
|
Wed Feb 2 16:32:02 2022, Anchal, Summary, BHD, Part IX of BHR upgrade - AS1 free swing test still not good 
|
Tue Mar 15 18:42:37 2022, Anchal, Summary, BHD, Part IX of BHR upgrade - AS1 resuspended and OSEMs tuned
|
Tue Mar 15 18:45:12 2022, Anchal, Summary, BHD, Part X of BHR upgrade - BHDBS Path setup
|
Thu Jan 13 12:29:27 2022, Anchal, Summary, BHD, AS4 LR magnet broke
|
Fri Jan 14 18:12:47 2022, Anchal, Summary, BHD, AS4 placed in ITMY Chamber, OSEMs connected
|
Tue Jan 18 18:19:22 2022, Koji, Summary, BHD, AS4 placed in ITMY Chamber, OSEMs connected 
|
Wed Jan 19 12:56:52 2022, Paco, Summary, BHD, AS4 OSEMs installation
|
Thu Jan 20 16:42:55 2022, Paco, Update, BHD, AS4 OSEMs installation - part 2
|
Thu Jan 20 18:16:29 2022, Anchal, Update, BHD, AS4 set to trigger free swing test
|
Fri Jan 21 16:40:10 2022, Anchal, Update, BHD, AS4 Input Matrix Diagonalization performed. 
|
Mon Jan 24 17:12:27 2022, rana, Update, BHD, AS4 Input Matrix Diagonalization performed.
|
Mon Jan 24 20:48:48 2022, Anchal, Update, BHD, AS4 Input Matrix Diagonalization performed.
|
Tue Jan 18 15:19:49 2022, Paco, Summary, BHD, Part IV of BHR upgrade - Replaced old SR3 with SOS SR2. OSEM tuning attemtped. 
|
Tue Jan 18 18:16:28 2022, Anchal, Summary, BHD, Part IV of BHR upgrade - SR2 Sat Amp Box inspection
|
Wed Jan 19 12:50:10 2022, Anchal, Summary, BHD, Part IV of BHR upgrade - SR2 OSEM tuning progress.
|
Thu Jan 20 17:03:36 2022, Anchal, Summary, BHD, Part IV of BHR upgrade - SR2 OSEM tuned.
|
Thu Jan 20 18:41:55 2022, Anchal, Summary, BHD, SR2 set to trigger free swing test
|
Fri Jan 21 11:24:42 2022, Anchal, Summary, BHD, SR2 Input Matrix Diagonalization performed. 
|
Thu Oct 28 17:01:54 2021, Anchal, Summary, BHD, Part III of BHR upgrade - Adding temp fixed flat mirror for PR2
|
Thu Jan 27 17:57:35 2022, Anchal, Summary, BHD, Part III of BHR upgrade - Replaced small suspended PR3 with new SOS PR3 and OSEM tuning
|
Thu Jan 27 18:03:36 2022, Paco, Summary, BHD, Part III of BHR upgrade - Install PR2, balance, and attempt OSEM tuning
|
Thu Jan 27 20:46:38 2022, Koji, Summary, BHD, Part III of BHR upgrade - Install PR2, balance, and attempt OSEM tuning 
|
Fri Jan 28 10:37:59 2022, Paco, Summary, BHD, Part III of BHR upgrade - PR2 OSEM finalized, reinsall LO1 OSEMs
|
Fri Jan 28 11:30:52 2022, Koji, Summary, BHD, Part III of BHR upgrade - PR2 OSEM finalized, reinsall LO1 OSEMs
|
Fri Jan 28 16:35:18 2022, Anchal, Summary, BHD, AS1, PR2 and PR3 set to trigger free swing test
|
Wed Feb 2 16:22:00 2022, Anchal, Summary, BHD, Part III of BHR upgrade - PR2 inpute matrix diagonalized 
|
Wed Feb 2 16:27:57 2022, Anchal, Summary, BHD, Part III of BHR upgrade - PR3 inpute matrix diagonalized 
|
Wed Oct 27 16:38:02 2021, Anchal, Summary, BHD, Part II of BHR upgrade - Relocation of TT2 and MMT1/2 alignment
|
Wed Oct 27 18:11:37 2021, Koji, Summary, BHD, Part II of BHR upgrade - Relocation of TT2 and MMT1/2 alignment
|
Wed Oct 27 18:16:45 2021, Koji, Summary, BHD, Part II of BHR upgrade - Relocation of TT2 and MMT1/2 alignment
|
Thu Mar 17 17:23:22 2022, Anchal, Summary, BHD, Part IIa of BHR upgrade - Green laser alignment
|
Mon Mar 21 18:24:07 2022, Anchal, Summary, BHD, Part IIa of BHR upgrade - Green laser alignment on Yarm
|
Thu Mar 24 19:20:28 2022, Anchal, Summary, BHD, Part IIa of BHR upgrade - Green laser alignment on Yarm
|
Fri Mar 25 18:20:28 2022, Anchal, Summary, BHD, Part IIa of BHR upgrade - Green laser alignment on Yarm
|
Sat Mar 26 13:04:38 2022, Paco, Summary, BHD, Part IIa of BHR upgrade - Green laser alignment on Yarm
|
Thu Mar 31 18:58:16 2022, Ian MacMillan, Summary, BHD, Part IIa of BHR upgrade - IR laser alignment on Xarm
|
Tue Apr 5 18:15:06 2022, Anchal, Summary, BHD, Part IIa of BHR upgrade - IR laser alignment on Xarm
|
Wed Apr 6 01:20:48 2022, Koji, Summary, BHD, Part IIa of BHR upgrade - IR laser alignment on Xarm   
|
Wed Apr 6 22:51:47 2022, Koji, Summary, BHD, Part IIa of BHR upgrade - IR laser alignment on Xarm 
|
Wed Apr 6 12:03:51 2022, Anchal, Summary, BHD, Part IIa of BHR upgrade - IR laser alignment on Yarm
|
Thu Apr 7 17:59:51 2022, Anchal, Summary, BHD, Part IIa of BHR upgrade - IR laser alignment on Yarm
|
Fri Apr 8 17:21:31 2022, Ian MacMillan, Summary, BHD, Part IIa of BHR upgrade - IR laser alignment on Yarm
|
Mon Apr 11 21:13:21 2022, Paco, Summary, BHD, Part IIa of BHR upgrade - POY11 debugging
|
Mon Apr 11 21:44:14 2022, Koji, Summary, BHD, Part IIa of BHR upgrade - POY11 debugging  
|
Thu Apr 14 11:52:57 2022, yehonathan, Summary, BHD, Part IIa of BHR upgrade - POY11 debugging 
|
Thu Apr 14 18:39:13 2022, Paco, Summary, BHD, Part IIa of BHR upgrade - POY11 debugging
|
Mon Apr 18 17:53:45 2022, Paco, Summary, BHD, Part IIa of BHR upgrade - POY11 debugging
|
Fri Apr 15 11:59:16 2022, Yehonathan, Update, IOO, IMC completely misaligned
|
Thu Apr 14 09:04:30 2022, Jordan, Update, VAC, RGA Volume RGA Scans 
|
Wed Apr 13 15:57:25 2022, Ian MacMillan, Update, Cameras, Camera Battery Test
|
Wed Apr 13 18:55:54 2022, Koji, Update, Cameras, Camera Battery Test
|
Wed Apr 13 16:23:54 2022, Ian MacMillan, Update, General, Smell in 40m
|
Mon Apr 11 11:00:30 2022, Jancarlo, Update, VAC, C1VAC Reboot and Nitrogen tanks
|
Thu Apr 7 20:41:15 2022, Tommy, Update, Electronics, RFSoC 2x2 Board -- Gain Plotter  
|
Thu Apr 7 20:37:06 2022, Tommy, Update, Electronics, RFSoC 2x2 Board -- Simple Tone Generator
|
Wed Mar 9 11:52:18 2022, Yehonathan, Update, BHD, Simplified BHD readout sketch on ITMY table
|
Wed Mar 9 12:57:52 2022, Koji, Update, BHD, Simplified BHD readout sketch on ITMY table
|
Fri Apr 1 14:26:50 2022, Tega, Update, Optical Levers, Simplified sketch on MC table
|
Fri Apr 1 17:02:02 2022, Koji, Update, Optical Levers, Simplified sketch on MC table
|
Fri Apr 1 22:22:29 2022, Koji, Update, Optical Levers, Simplified sketch on MC table
|
Mon Apr 4 15:49:06 2022, Tega, Update, Optical Levers, Simplified sketch on BS table
|
Wed Oct 20 11:16:21 2021, Anchal, Summary, PEM, Particle counter setup near BS Chamber
|
Thu Oct 21 11:41:31 2021, Anchal, Summary, PEM, Particle counter setup near BS Chamber
|
Thu Oct 21 15:22:35 2021, rana, Summary, PEM, Particle counter setup near BS Chamber
|
Thu Oct 21 15:24:35 2021, rana, Summary, PEM, Particle counter setup near BS Chamber
|
Fri Oct 22 17:35:08 2021, Ian MacMillan, Summary, PEM, Particle counter setup near BS Chamber
|
Fri Apr 1 14:26:19 2022, Ian MacMillan, Summary, PEM, Particle counter setup near BS Chamber
|
Sat Apr 2 15:46:13 2022, rana, Summary, PEM, Particle counter setup near BS Chamber
|
Tue Mar 29 17:35:54 2022, Paco, Update, SUS, Damping fix on BS, AS4, PR2, and PR3
|
Tue Mar 29 15:07:11 2022, Tega, Summary, VAC, Opening of MC and ETM chambers
|
Tue Feb 22 18:47:51 2022, Ian MacMillan, Update, SUS, ETMY SUS Electronics Replacement 
|
Fri Feb 25 14:00:08 2022, Ian MacMillan, Update, SUS, ETMY SUS Electronics Replacement 
|
Fri Feb 25 14:48:53 2022, Ian MacMillan, Update, SUS, ETMY SUS Electronics Replacement 
|
Sat Feb 26 23:48:14 2022, Koji, Update, SUS, ETMY SUS Electronics Replacement
|
Mon Feb 28 15:51:07 2022, Ian MacMillan, Update, SUS, ETMY 1Y4 Electronics Replacement   
|
Thu Mar 3 04:11:36 2022, Koji, Update, SUS, ETMY 1Y4 Electronics Replacement  
|
Thu Mar 3 04:24:23 2022, Koji, Update, SUS, ETMY 1Y4 Electronics Replacement 
|
Thu Mar 3 17:21:11 2022, Ian MacMillan, Update, SUS, ETMY 1Y4 Electronics Replacement
|
Sat Mar 5 02:03:46 2022, Koji, Update, SUS, ETMY 1Y4 Electronics Replacement 6x
|
Mon Mar 21 14:22:52 2022, Anchal, Update, SUS, ETMY Alignmnet offsets needed to be changed
|
Tue Mar 1 19:26:24 2022, Koji, Update, SUS, ETMY SUS Electronics Replacement 
|
Mon Mar 7 16:44:15 2022, Ian MacMillan, Update, SUS, ETMY SUS Electronics Replacement 6x
|
Fri Mar 11 16:43:03 2022, Ian MacMillan, Update, SUS, ETMY SUS Electronics Replacement
|
Fri Mar 25 11:39:14 2022, Anchal, Update, SUS, ETMY SUS Electronics Replacement - Questions
|
Mon Mar 28 16:25:34 2022, Ian MacMillan, Update, SUS, ETMY SUS Electronics Replacement - Questions
|
Thu Mar 17 11:40:41 2022, Paco, Update, SUS, ETMY green PZT HV supply
|
Thu Mar 17 16:50:53 2022, Paco, Update, BHD, XARM AUX alignment
|
Fri Mar 18 17:15:19 2022, Paco, Update, BHD, XARM AUX alignment cont.
|
Mon Mar 21 18:00:05 2022, Ian MacMillan, Update, BHD, XARM AUX alignment cont.
|
Tue Mar 15 13:49:44 2022, Ian MacMillan, Bureaucracy, Treasure, New Screwdriver Bits
|
Tue Mar 15 10:45:31 2022, Paco, Update, General, Assembled small in-vac optics
|
Thu Mar 10 10:05:49 2022, Paco, Update, SUS, AS1 free swing test
|
Thu Mar 10 09:39:59 2022, Jordan, Update, VAC, Leak Testing of New Manual Gate Valve - Attempt #2 
|
Wed Mar 9 10:23:28 2022, Jordan, Update, VAC, Leak Testing of New Manual Gate Valve - Attempt #1
|
Tue Feb 2 17:09:17 2021, yehonathan, Update, BHD, SOS assembly 
|
Tue Feb 2 18:24:54 2021, Koji, Update, BHD, SOS assembly
|
Thu Feb 4 15:14:55 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Feb 16 13:13:39 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Feb 16 15:29:01 2021, Koji, Update, BHD, SOS assembly
|
Tue Feb 16 22:59:36 2021, Yehonathan, Update, BHD, SOS assembly
|
Fri Feb 19 12:21:04 2021, Yehonathan, Update, BHD, SOS assembly
|
Fri Mar 26 10:25:37 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Apr 6 15:42:57 2021, Yehonathan, Update, BHD, SOS assembly
|
Fri Apr 9 20:54:54 2021, Yehonathan, Update, BHD, SOS assembly 
|
Mon Apr 12 17:30:11 2021, Yehonathan, Update, BHD, SOS assembly
|
Mon May 3 16:49:04 2021, Yehonathan, Update, BHD, SOS assembly 
|
Tue Jun 1 16:17:06 2021, Yehonathan, Update, BHD, SOS assembly
|
Wed Jun 2 01:03:19 2021, Koji, Update, BHD, SOS assembly
|
Fri Jun 18 19:02:00 2021, Yehonathan, Update, BHD, SOS assembly  
|
Fri Jun 18 23:53:08 2021, Koji, Update, BHD, SOS assembly
|
Tue Jun 22 17:05:26 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Jul 27 17:14:18 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Jul 27 20:12:53 2021, Koji, Update, BHD, SOS assembly
|
Mon Jun 28 12:35:19 2021, Yehonathan, Update, BHD, SOS assembly    
|
Tue Jun 29 20:45:52 2021, Yehonathan, Update, BHD, SOS assembly 
|
Thu Jul 1 16:45:25 2021, Yehonathan, Update, BHD, SOS assembly
|
Wed Jul 28 12:00:35 2021, Yehonathan, Update, BHD, SOS assembly
|
Thu Sep 23 18:18:07 2021, Yehonathan, Update, BHD, SOS assembly 
|
Tue Oct 26 10:17:14 2021, Yehonathan, Update, BHD, SOS assembly
|
Thu Oct 28 23:13:19 2021, Yehonathan, Update, BHD, SOS assembly   
|
Tue Nov 2 15:02:03 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Nov 2 22:50:30 2021, Koji, Update, BHD, SOS assembly
|
Mon Nov 8 17:22:27 2021, Yehonathan, Update, BHD, SOS assembly 
|
Tue Nov 9 11:11:37 2021, Yehonathan, Update, BHD, SOS assembly
|
Fri Nov 12 23:47:29 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Nov 16 17:42:46 2021, Yehonathan, Update, BHD, SOS assembly    
|
Tue Nov 16 18:28:53 2021, Koji, Update, BHD, SOS assembly 
|
Wed Nov 24 14:15:15 2021, Yehonathan, Update, BHD, SOS assembly
|
Wed Dec 1 12:57:08 2021, Yehonathan, Update, BHD, SOS assembly 7x
|
Mon Dec 6 18:23:04 2021, Yehonathan, Update, BHD, SOS assembly
|
Thu Dec 9 21:57:35 2021, Yehonathan, Update, BHD, SOS assembly 
|
Tue Dec 14 14:02:33 2021, Yehonathan, Update, BHD, SOS assembly 
|
Wed Dec 15 22:09:53 2021, Yehonathan, Update, BHD, SOS assembly
|
Thu Dec 16 18:16:36 2021, Yehonathan, Update, BHD, SOS assembly   
|
Fri Dec 17 17:50:17 2021, Yehonathan, Update, BHD, SOS assembly   
|
Fri Dec 17 19:16:45 2021, Koji, Update, BHD, SOS assembly
|
Fri Dec 17 22:16:07 2021, Yehonathan, Update, BHD, SOS assembly
|
Sat Dec 18 00:56:14 2021, Koji, Update, BHD, SOS assembly
|
Mon Dec 20 13:52:01 2021, Koji, Update, BHD, SOS assembly
|
Mon Dec 20 17:26:13 2021, Yehonathan, Update, BHD, SOS assembly 7x
|
Tue Dec 21 18:04:46 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Jan 4 18:27:23 2022, Paco, Update, BHD, SOS assembly -- PR3    
|
Wed Jan 5 19:18:06 2022, Yehonathan, Update, BHD, SOS assembly -- AS4  
|
Thu Jan 6 17:00:20 2022, Yehonathan, Update, BHD, SOS assembly -- LO2  
|
Thu Jan 6 17:16:51 2022, Yehonathan, Update, BHD, Using Peek screws/nuts
|
Fri Jan 7 17:59:45 2022, Yehonathan, Update, BHD, SOS assembly -- SR2  
|
Fri Jan 7 18:24:25 2022, Koji, Update, BHD, SOS assembly -- SR2
|
Mon Jan 10 14:00:44 2022, not Koji, Update, BHD, SOS assembly -- SR2
|
Tue Jan 11 09:53:14 2022, not Koji, Update, BHD, SOS assembly -- Peek screws and nuts
|
Thu Jan 13 16:08:00 2022, Yehonathan, Update, BHD, gluing magnets after AS1/4 misfortune
|
Fri Jan 14 17:33:10 2022, Yehonathan, Update, BHD, AS4 resurrection  
|
Wed Jan 19 18:15:34 2022, Yehonathan, Update, BHD, AS1 resurrection   
|
Thu Jan 20 12:10:51 2022, Yehonathan, Update, BHD, AS1 resurrection  
|
Mon Jan 24 17:58:21 2022, Yehonathan, Update, BHD, PR2 Suspension
|
Tue Jan 25 18:37:12 2022, TYehonathan, Update, BHD, PR2 Suspension  
|
Thu Feb 24 18:05:58 2022, Yehonathan, Update, BHD, Re-susspension of AS1 
|
Wed Mar 2 14:02:43 2022, Yehonathan, Update, BHD, Re-susspension of AS1
|
Thu Mar 3 17:09:46 2022, Paco, Update, BHD, Re-susspension of AS1
|
Mon Mar 7 16:56:08 2022, Yehonathan, Update, BHD, Re-susspension of AS1  
|
Mon Mar 7 18:53:16 2022, Koji, Update, BHD, Re-susspension of AS1
|
Tue Mar 8 12:24:13 2022, Yehonathan, Update, BHD, Re-susspension of AS1  
|
Tue Mar 8 19:29:36 2022, Paco, Update, BHD, Re-balance of AS1
|
Wed Mar 9 09:35:26 2022, Paco, Update, BHD, Re-balance of AS1
|
Sat Feb 26 01:01:40 2022, Tega, Update, VAC, Ongoing work to get the FRG gauges readouts to EPICs channels
|
Sat Feb 26 15:45:14 2022, Tega, Update, VAC, Ongoing work to get the FRG gauges readouts to EPICs channels
|
Mon Feb 28 19:15:10 2022, Tega, Update, VAC, Ongoing work to get the FRG gauges readouts to EPICs channels
|
Tue Mar 1 20:38:49 2022, Tega, Update, VAC, Ongoing work to get the FRG gauges readouts to EPICs channels   
|
Wed Mar 2 11:50:39 2022, Tega, Update, VAC, Ongoing work to get the FRG gauges readouts to EPICs channels    
|
Wed Mar 2 12:40:08 2022, Tega, Update, VAC, Ongoing work to get the FRG gauges readouts to EPICs channels 6x
|
Sun Mar 6 18:14:45 2022, Tega, Update, VAC, Ongoing work to get the FRG gauges readouts to EPICs channels
|
Mon Mar 7 13:53:40 2022, Tega, Update, VAC, Ongoing work to get the FRG gauges readouts to EPICs channels
|
Mon Mar 7 14:52:34 2022, Koji, Update, VAC, Ongoing work to get the FRG gauges readouts to EPICs channels
|
Tue Mar 8 12:08:47 2022, Tega, Update, VAC, Ongoing work to get the FRG gauges readouts to EPICs channels
|
Mon Mar 7 10:06:32 2022, Yehonathan, Update, IOO, IMC unlocked again, completely misaligned
|
Mon Mar 7 14:55:33 2022, Koji, Update, IOO, IMC unlocked again, completely misaligned
|
Sat Mar 5 01:58:49 2022, Koji, Summary, CDS, paola rescue 
|
Fri Mar 4 18:12:44 2022, Koji, Update, VAC, RGA pumping down
|
Mon Feb 7 09:00:26 2022, Paco, Update, General, Scheduled power outage recovery
|
Mon Feb 7 15:32:48 2022, Yehonathan, Update, General, Y End laser controller
|
Mon Feb 7 16:53:02 2022, Koji, Update, General, Scheduled power outage recovery 
|
Wed Feb 9 11:56:24 2022, Anchal, Update, General, Bringing back CDS
|
Wed Feb 9 13:55:05 2022, Koji, Update, General, Bringing back CDS
|
Wed Feb 9 16:43:35 2022, Paco, Update, General, Scheduled power outage recovery - Locking mode cleaner(s)
|
Thu Feb 10 15:41:00 2022, Anchal, Update, General, Scheduled power outage recovery - Locking mode cleaner(s)
|
Thu Feb 10 17:57:48 2022, Anchal, Update, General, Scheduled power outage recovery - Locking mode cleaner(s)
|
Thu Feb 10 19:03:23 2022, Koji, Update, General, Scheduled power outage recovery - Locking mode cleaner(s)
|
Thu Feb 10 19:46:37 2022, Koji, Update, General, Scheduled power outage recovery - Locking mode cleaner(s)
|
Thu Feb 10 21:10:43 2022, Koji, Update, General, Video Mux setting reset 
|
Fri Feb 11 16:09:11 2022, Anchal, Update, General, Scheduled power outage recovery - Input power increased
|
Mon Feb 14 18:31:50 2022, Paco, Update, General, Scheduled power outage recovery - IMC recovery progress
|
Tue Feb 15 19:32:50 2022, Koji, Update, General, Scheduled power outage recovery - IMC recovery progress    
|
Tue Feb 15 19:40:02 2022, Koji, Update, General, IMC locking
|
Wed Feb 16 15:19:41 2022, Anchal, Update, General, Reconfigured MC reflection path for low power
|
Wed Feb 23 15:08:57 2022, Anchal, Update, General, Removed extra beamsplitter in MC WFS path
|
Thu Feb 24 14:32:57 2022, Anchal, Update, General, MC RFPD DCMON channel got stuck to 0
|
Thu Feb 24 19:26:32 2022, Anchal, Update, General, IMC Locking
|
Sun Feb 27 00:37:00 2022, Koji, Update, General, IMC Locking Recovery    
|
Sun Feb 27 01:12:46 2022, Koji, Update, General, IMC manual alignment procedure
|
Fri Feb 11 11:17:00 2022, Anchal, Update, General, Scheduled power outage recovery
|
Mon Feb 14 21:03:25 2022, Koji, Update, General, Scheduled power outage recovery
|
Mon Feb 14 18:43:49 2022, Paco, Summary, General, SOS materials clean room cleared
|
Thu Feb 10 21:51:02 2022, Koji, Update, CDS, [Solved] Huge random numbers flowing into ETMX/ETMY ASC PIT/YAW  
|
Fri Feb 11 10:56:38 2022, Anchal, Update, CDS, [Solved] Huge random numbers flowing into ETMX/ETMY ASC PIT/YAW
|
Fri Feb 11 12:22:19 2022, rana, Update, CDS, [Solved] Huge random numbers flowing into ETMX/ETMY ASC PIT/YAW
|
Fri Feb 11 17:07:19 2022, Anchal, Update, CDS, [Solved] Huge random numbers flowing into ETMX/ETMY ASC PIT/YAW
|
Thu Feb 10 21:16:27 2022, Koji, Summary, CDS, chiara resolv.conf wierdo
|
Thu Feb 10 14:39:31 2022, Koji, Summary, Computers, Network security issue resolved 
|
Tue Nov 9 13:40:02 2021, Ian MacMillan, Summary, Computer Scripts / Programs, SUS Plant Plan for New Optics
|
Tue Nov 9 16:55:52 2021, Ian MacMillan, Summary, Computer Scripts / Programs, SUS Plant Plan for New Optics
|
Tue Nov 9 18:05:03 2021, Ian MacMillan, Summary, Computer Scripts / Programs, SUS Plant Plan for New Optics
|
Mon Nov 15 15:12:28 2021, Ian MacMillan, Summary, Computer Scripts / Programs, SUS Plant Plan for New Optics
|
Tue Nov 16 17:29:49 2021, Ian MacMillan, Summary, Computer Scripts / Programs, SUS Plant Plan for New Optics
|
Thu Nov 18 20:00:43 2021, Ian MacMillan, Summary, Computer Scripts / Programs, SUS Plant Plan for New Optics
|
Mon Nov 22 16:38:26 2021, Tega, Summary, Computer Scripts / Programs, SUS Plant Plan for New Optics
|
Mon Jan 24 17:10:25 2022, Tega, Summary, Computer Scripts / Programs, SUS Plant Plan for New Optics
|
Thu Jan 27 16:40:57 2022, Tega, Summary, Computer Scripts / Programs, SUS Plant Plan for New Optics 
|
Thu Feb 3 17:15:23 2022, Tega, Summary, Computer Scripts / Programs, SUS Plant Plan for New Optics
|
Wed Feb 9 14:34:27 2022, Ian, Summary, Computer Scripts / Programs, SUS Plant Plan for New Optics
|
Mon Feb 7 16:14:37 2022, Tega, Update, Computers, realtime system reboot problem
|
Fri Feb 4 10:21:39 2022, Anchal, Summary, General, Complete lab shutdown
|
Fri Feb 4 10:04:47 2022, Chub, Update, General, dish soap and clean scrub sponges!
|
Thu Feb 3 14:47:12 2022, Chub, Update, Electronics, new UPS in place
|
Thu Feb 3 10:25:59 2022, Jordan, Update, VAC, TP1 and Manual Gate Valve Install  
|
Thu Jan 20 17:34:07 2022, Koji, Update, BHD, V6-704/705 Mirror now @Downs 
|
Fri Jan 21 14:51:00 2022, Koji, Update, BHD, V6-704/705 Mirror now @Downs   
|
Tue Feb 1 20:16:09 2022, Tega, Update, BHD, PR2 candidate mirror analysis  
|
Mon Jan 31 10:39:19 2022, Jordan, Update, VAC, TP1 and Manual Gate Valve Removal   
|
Mon Jan 24 12:33:41 2022, rana, Configuration, Wiki, AIC Wiki: txz files allowed
|
Thu Jan 6 22:18:47 2022, Koji, Update, CDS, SUS screen debugging
|
Tue Jan 11 10:46:07 2022, Tega, Update, CDS, SUS screen debugging
|
Fri Jan 21 12:46:31 2022, Tega, Update, CDS, SUS screen debugging
|
Tue Jan 11 10:58:58 2022, Tega, Update, SUS, Temporary watchdog
|
Tue Jan 11 13:43:14 2022, Koji, Update, SUS, Temporary watchdog
|
Wed Jan 19 21:39:22 2022, Tega, Update, SUS, Temporary watchdog
|
Thu Jan 20 00:26:50 2022, Koji, Update, SUS, Temporary watchdog
|
Thu Jan 20 17:21:21 2022, Tega, Update, SUS, Temporary watchdog
|
Tue Jan 4 18:26:59 2022, Anchal, Update, BHD, Tested 2" PR2 candidates transmission
|
Wed Jan 5 17:46:04 2022, Anchal, Update, BHD, Tested 2" PR2 candidates transmission
|
Mon Jan 10 18:20:45 2022, Anchal, Update, BHD, Tested 2" PR2 candidates transmission
|
Tue Jan 11 15:21:16 2022, Anchal, Update, BHD, PR2 transmission calculation  
|
Thu Jan 13 17:10:55 2022, Anchal, Update, BHD, PR2 transmission calculation  
|
Fri Jan 14 03:07:04 2022, Koji, Update, BHD, PR2 transmission calculation
|
Fri Jan 14 11:00:29 2022, Anchal, Update, BHD, PR2 transmission calculation
|
Fri Jan 14 13:46:25 2022, Anchal, Update, BHD, PR2 transmission calculation updated  
|
Wed Jan 19 16:22:48 2022, Anchal, Update, BHD, PR2 transmission calculation updated 
|
Thu Jan 20 01:48:02 2022, Koji, Update, BHD, PR2 transmission calculation updated
|
Wed Jan 19 14:41:23 2022, Koji, Update, BHD, Suspension Status
|
Fri Jan 14 14:04:51 2022, Paco, Update, Electronics, RFSoC 2x2 board arrived
|
Thu Dec 16 15:04:12 2021, Chub, Update, Electronics, ITMX feedthroughs and in-vac cables installed
|
Thu Dec 16 15:54:08 2021, Koji, Update, Electronics, ITMX feedthroughs and in-vac cables installed
|
Mon Jan 10 15:45:55 2022, Paco, Update, Electronics, ITMY feedthroughs and in-vac cables installed - part I
|
Tue Jan 11 10:23:18 2022, Paco, Update, Electronics, ITMY feedthroughs and in-vac cables installed - part II
|
Tue Jan 11 14:21:53 2022, Paco, Update, Electronics, BS feedthroughs and in-vac cables installed
|
Fri Jan 14 12:01:21 2022, Anchal, Update, Electronics, BS & ITMY feedthroughs labeled and connected to Sat Amps
|
Tue Dec 14 19:29:42 2021, Paco, Update, BHD, 1Y0 rack work for LO1
|
Mon Jan 3 12:05:08 2022, Paco, Update, BHD, 1Y0 rack work for LO2 AS1 AS4
|
Mon Jan 3 16:46:41 2022, Paco, Update, BHD, 1Y1 rack work for SR2, PR2, PR3
|
Fri Jan 7 17:54:13 2022, Anchal, Update, BHD, PR2 Sat Amp has a bad channel
|
Fri Jan 7 18:28:13 2022, Koji, Update, BHD, PR2 Sat Amp has a bad channel
|
Mon Jan 10 13:35:52 2022, Anchal, Update, BHD, PR2 Sat Amp has a bad channel
|
Mon Jan 10 15:59:46 2022, Koji, Update, BHD, PR2 Sat Amp has a bad channel 6x
|
Mon Jan 10 17:04:47 2022, Anchal, Update, BHD, AS1 Sat Amp CH2 had offset
|
Thu Jan 6 15:10:38 2022, Koji, Update, SUS, ITMX Chamber work   
|
Thu Jan 6 14:08:14 2022, Koji, Update, CDS, More BHD SUS screens added to sitemap
|
Wed Jan 15 08:55:14 2020, gautam, Update, CDS, Yearly DAQD fix
|
Thu Jan 6 12:52:49 2022, Anchal, Update, CDS, Yearly DAQD fix 2022!
|
Thu Jan 6 13:54:28 2022, Koji, Update, CDS, Yearly DAQD fix 2022!
|
Sun Jan 2 20:46:46 2022, Koji, Update, SUS, End SUS Electronics building
|
Wed Dec 22 14:57:05 2021, Koji, Update, General, chiara local backup
|
Thu Dec 23 16:38:21 2021, Koji, Update, General, Is megatron down? (Re: chiara local backup)
|
Fri Dec 24 16:49:41 2021, Koji, Update, General, Is megatron down? (Re: chiara local backup)
|
Fri Dec 17 12:32:35 2021, Koji, Update, SUS, Remaining task for 2021
|
Fri Dec 17 19:19:42 2021, Koji, Update, SUS, Remaining task for 2021
|
Sun Dec 19 07:52:51 2021, Anchal, Update, SUS, Remaining task for 2021
|
Wed Dec 22 18:16:23 2021, Koji, Update, SUS, Remaining task for 2021 
|
Tue Dec 21 16:52:39 2021, Anchal, Summary, Electronics, In-air Sat Amp to Vacuum Flange cables laid for 7 new SOS
|
Tue Dec 21 16:35:39 2021, Koji, Update, VAC, ITMX NW feedthru (LO1-1) connector pin bent 
|
Fri Dec 10 15:59:23 2021, Paco, Update, BHD, Finished Coil driver (even serial number) units tests
|
Thu Dec 16 12:21:16 2021, Anchal, Update, BHD, Coil driver test failed for S2100619-v1
|
Thu Dec 16 17:41:12 2021, Koji, Update, BHD, Coil driver test failed for S2100619-v1 6x
|
Thu Dec 16 15:32:59 2021, Anchal, Update, BHD, Finished Coil driver (odd serial number) units tests
|
Thu Dec 16 17:57:17 2021, Anchal, Update, BHD, Finished Coil driver (odd serial number) units tests
|
Mon Dec 20 14:10:56 2021, Anchal, Update, BHD, All coil drivers ready to be used, modified and tested
|
Wed Dec 15 15:06:08 2021, Jordan, Update, VAC, Vacuum Feedthru Install
|
Wed Dec 15 13:57:59 2021, Paco, Update, Computers, upgraded ubuntu on zita
|
Mon Dec 13 15:05:47 2021, Tega, Update, PEM, git repo for temp sensor and sus medm
|
Tue Dec 14 11:33:29 2021, Tega, Update, PEM, git repo for temp sensor and sus medm
|
Fri Dec 10 21:35:15 2021, Koji, Summary, SUS, Vertex SUS DAC adapter ready  
|
Mon Dec 6 14:26:52 2021, Koji, Update, VAC, Pumping down the RGA section
|
Tue Dec 7 13:12:50 2021, Koji, Update, VAC, Pumping down the RGA section
|
Wed Dec 8 10:14:43 2021, Jordan, Update, VAC, Pumping down the RGA section 
|
Fri Dec 10 19:22:01 2021, Koji, Update, VAC, Pumping down the RGA section
|
Thu Dec 9 00:32:56 2021, Tega, Update, CDS, New SUS medm screen update 
|
Thu Dec 9 18:22:36 2021, Tega, Update, CDS, New SUS medm screen update
|
Fri Dec 10 18:55:58 2021, Tega, Update, CDS, New SUS medm screen update
|
Mon Aug 23 11:51:26 2021, Koji, Update, General, Campus Wide Power Glitch Reported: Monday, 8/23/21 at 9:30am
|
Mon Aug 23 19:00:05 2021, Koji, Update, General, Campus Wide Power Glitch Reported: Monday, 8/23/21 at 9:30am
|
Mon Aug 23 22:51:44 2021, Anchal, Update, General, Time synchronization efforts
|
Tue Aug 24 09:22:48 2021, Anchal, Update, General, Time synchronization working now
|
Tue Aug 24 18:11:27 2021, Paco, Update, General, Time synchronization not really working
|
Tue Aug 24 22:37:40 2021, Anchal, Update, General, Time synchronization not really working
|
Wed Nov 17 17:37:53 2021, Anchal, Update, General, Placed Nodus and fb1 on UPS power
|
Thu Nov 18 15:16:10 2021, Anchal, Update, General, Moved Chiara to 1X7 above nodus powered with same UPS
|
Mon Nov 22 17:42:19 2021, Anchal, Update, General, Connected Megatron to battery backed ports of another UPS
|
Tue Nov 30 17:11:06 2021, Paco, Update, General, Moved white rack to 1X3.5 
|
Wed Nov 24 17:13:31 2021, Yehonathan, Metaphysics, General, Toilet tank broken
|
Tue Nov 30 11:03:44 2021, Yehonathan, Metaphysics, General, Toilet tank broken
|
Mon Nov 29 15:24:53 2021, Hang, HowTo, General, Fisher matrix vs length of each FFT segment   
|
Wed Nov 24 14:34:15 2021, Yehonathan, Update, BHD, Saving on SUSAUX slow channels
|
Tue Nov 23 18:02:05 2021, Anchal, Update, IMC, MC autolocker shifted to python3 script running in docker
|
Thu Nov 18 14:29:01 2021, Koji, Summary, BHD, BHD invac optics / opto-mechanics
|
Wed Nov 17 07:32:48 2021, Chub, Update, General, wire clamp plate mod
|
Wed Nov 17 11:53:27 2021, Koji, Update, General, wire clamp plate mod
|
Tue Nov 16 11:37:26 2021, Hang, HowTo, SUS, Fitting suspension model--large systematic errors 
|
Thu Nov 11 00:11:39 2021, Koji, Summary, SUS, 2" to 3" sleeve issue 6x
|
Fri Oct 29 14:39:37 2021, Anchal, Summary, BHD, 1Y1 cleared. IY3 ready for C1SUS2 I/O and FE.  
|
Tue Nov 2 16:42:00 2021, Paco, Summary, BHD, 1Y1 rack work
|
Tue Nov 2 18:54:41 2021, Anchal, Paco, Update, BHD, Optical fibres laid for BHD upgrade
|
Thu Nov 4 15:03:43 2021, Koji, Summary, BHD, 1Y1 rack work
|
Mon Nov 8 10:13:52 2021, Paco, Summary, BHD, 1Y1 rack work; Sorensens removed
|
Mon Nov 8 13:13:00 2021, Koji, Summary, BHD, 1Y1 rack work; Sorensens removed
|
Mon Nov 8 15:29:05 2021, Paco, Summary, BHD, 1Y1 rack work; New power for cameras
|
Mon Nov 8 18:42:38 2021, Koji, Summary, BHD, Rack Layout / Power Strips
|
Tue Nov 9 19:02:47 2021, Anchal, Summary, BHD, 1Y0 Populated and 1Y1,1Y0 powered
|
Thu Nov 4 18:29:51 2021, Tega, Update, SUS, Setting up suspension test model
|
Fri Nov 5 12:49:32 2021, rana, Update, SUS, Setting up suspension test model
|
Mon Nov 8 17:52:22 2021, Ian MacMillan, Update, SUS, Setting up suspension test model
|
Fri Nov 5 20:35:10 2021, Koji, Update, BHD, Feedthru / Optical Mounts
|
Wed Nov 3 16:55:23 2021, Ian MacMillan, Summary, SUS, SUS Plant Plan for New Optics
|
Mon Nov 1 14:51:34 2021, Koji, Update, General, Checking the vent plan
|
Sun Oct 31 14:21:31 2021, rana, HowTo, Treasure, IFOCad
|
Wed Oct 27 19:34:52 2021, Koji, Summary, Electronics, New electronics racks   
|
Tue Oct 26 14:53:24 2021, Koji, Update, Electronics, Rack
|
Tue Oct 26 13:27:07 2021, Tega, Summary, Electronics, Sat Amp modification Summary 
|
Thu Oct 21 11:38:43 2021, Jordan, Update, SUS, Standoffs for Side Magnet on 3" Adapter Ring SOS Assembly
|
Mon Oct 18 10:02:17 2021, Koji, Update, VAC, Vent Started / Completed 
|
Tue Oct 19 10:59:09 2021, Koji, Update, VAC, Vent Started / Completed
|
Tue Oct 19 11:30:39 2021, Koji, Update, VAC, How to vent TP1
|
Wed Oct 20 15:58:27 2021, Koji, Update, VAC, How to vent TP1
|
Mon Oct 18 16:48:32 2021, Tega, Update, Electronics, Sat Amp modifications
|
Fri Oct 15 16:46:27 2021, Anchal, Summary, Optical Levers, Vent Prep   
|
Fri Oct 15 17:17:51 2021, Koji, Summary, General, Vent Prep 7x
|
Fri Oct 15 20:53:49 2021, Koji, Summary, General, Vent Prep
|
Thu Oct 14 16:38:26 2021, Ian MacMillan, Update, General, Kicking optics in freeSwing measurment
|
Fri Oct 15 12:14:27 2021, Ian MacMillan, Update, General, Kicking optics in freeSwing measurment
|
Thu Oct 14 20:16:22 2021, Yehonathan, Update, General, PRMI free swinging
|
Thu Oct 14 18:30:23 2021, Koji, Summary, VAC, Flange/Cable Stand Configuration
|
Mon Sep 20 12:20:31 2021, Paco, Summary, SUS, PRM and BS Angular Actuation transfer function magnitude measurements   
|
Mon Sep 20 14:22:00 2021, rana, Summary, SUS, PRM and BS Angular Actuation transfer function magnitude measurements
|
Thu Sep 23 15:29:11 2021, Paco, Summary, SUS, PRM and BS Angular Actuation transfer function magnitude measurements
|
Fri Oct 1 14:25:27 2021, yehonathan, Summary, SUS, PRM and BS Angular Actuation transfer function magnitude measurements 
|
Mon Oct 4 16:00:57 2021, Yehonathan, Summary, SUS, PRM and BS Angular Actuation transfer function magnitude measurements  
|
Mon Oct 4 16:10:09 2021, rana, Summary, SUS, PRM and BS Angular Actuation transfer function magnitude measurements
|
Tue Oct 5 20:04:22 2021, Paco, Summary, SUS, PRM and BS Angular Actuation transfer function magnitude measurements
|
Wed Oct 6 15:39:29 2021, Anchal, Summary, SUS, PRM and BS Angular Actuation transfer function magnitude measurements
|
Tue Oct 12 11:32:54 2021, Yehonathan, Summary, SUS, PRM and BS Angular Actuation transfer function magnitude measurements 
|
Tue Oct 12 16:39:52 2021, rana, Summary, SUS, PRM and BS Angular Actuation transfer function magnitude measurements
|
Thu Oct 14 13:40:49 2021, Yehonathan, Summary, SUS, PRM and BS Angular Actuation transfer function magnitude measurements 
|
Thu Oct 14 09:28:46 2021, Yehonathan, Update, PSL, PMC unlocked
|
Thu Oct 14 11:25:49 2021, Yehonathan, Update, PSL, PMC unlocked 
|
Wed Oct 13 15:36:38 2021, Hang, Update, Calibration, XARM OLTF
|
Fri Oct 8 17:33:13 2021, Hang, Update, SUS, More PRM L2P measurements
|
Mon Oct 11 11:13:04 2021, rana, Update, SUS, More PRM L2P measurements
|
Mon Oct 11 13:59:47 2021, Hang, Update, SUS, More PRM L2P measurements   
|
Mon Sep 20 20:43:38 2021, Tega, Update, Electronics, Sat Amp modifications
|
Wed Sep 22 17:22:59 2021, Tega, Update, Electronics, Sat Amp modifications
|
Mon Oct 4 18:35:12 2021, Paco, Update, Electronics, Satellite amp box adapters  
|
Mon Oct 4 20:46:08 2021, Koji, Update, Electronics, Satellite amp box adapters
|
Thu Oct 7 02:04:19 2021, Koji, Update, Electronics, Satellite amp adapter chassis
|
Mon Oct 4 21:58:17 2021, Tega, Update, Electronics, Sat Amp modifications
|
Tue Oct 5 17:01:20 2021, Koji, Update, Electronics, Sat Amp modifications
|
Wed Oct 6 16:31:02 2021, Tega, Update, Electronics, Sat Amp modifications
|
Wed Oct 6 15:04:36 2021, Hang, Update, SUS, PRM L2P TF measurement & Fisher matrix analysis   
|
Mon Oct 4 15:50:31 2021, Hang, Update, Calibration, Fisher matrix estimation on XARM parameters   
|
Fri Oct 1 12:12:54 2021, Stephen, Update, BHD, ITMY (3002) CAD layout pushed to Box 
|
Tue Sep 7 18:00:54 2021, Tega, Summary, Calibration, System Identification via line injection  
|
Tue Sep 21 11:09:34 2021, Anchal, Summary, CDS, XARM YARM UGF Servo and Oscillators added
|
Wed Sep 22 12:40:04 2021, Anchal, Summary, CDS, XARM YARM UGF Servo and Oscillators shifted to OAF
|
Tue Sep 21 11:13:01 2021, Paco, Summary, Calibration, XARM calibration noise   
|
Wed Sep 22 11:43:04 2021, rana, Summary, Calibration, XARM calibration noise
|
Tue Sep 28 16:31:52 2021, Paco, Summary, Calibration, XARM OLTF (calibration) at 55.511 Hz    
|
Thu Sep 30 18:04:31 2021, Paco, Summary, Calibration, XARM OLTF (calibration) with three lines 
|
Mon Sep 13 09:15:15 2021, Paco, Update, LSC, MC unlocked?
|
Mon Sep 13 15:14:36 2021, Anchal, Update, LSC, Xend Green laser injection mirrors M1 and M2 not responsive
|
Thu Sep 30 14:13:18 2021, Anchal, Update, LSC, HV supply to Xend Green laser injection mirrors M1 and M2 PZT restored
|
Wed Sep 29 09:36:26 2021, Jordan, Update, SUS, 2" Adapter Ring Parts for SOS Arrived 9/28/21
|
Thu Sep 23 14:17:44 2021, Tega, Update, Electronics, Sat Amp modifications debugging update
|
Mon Sep 20 15:23:08 2021, Yehonathan, Update, Computers, Wifi internet fixed
|
Mon Sep 20 21:56:07 2021, Koji, Update, Computers, Wifi internet fixed
|
Mon Sep 20 14:11:40 2021, Koji, Update, BHD, End DAC Adapter Unit D2100647
|
Fri Sep 17 20:22:55 2021, Koji, Update, SUS, EQ M4.3 Long beach
|
Thu Sep 16 01:16:48 2021, Koji, Update, General, Frozen 2
|
Thu Sep 16 10:07:25 2021, Anchal, Update, General, Melting 2
|
Thu Sep 16 20:18:13 2021, Anchal, Update, General, Reset
|
Fri Sep 17 00:56:49 2021, Koji, Update, General, Awesome
|
Thu Sep 16 14:08:14 2021, Ian MacMillan, Frogs, , Tour
|
Thu Sep 16 12:06:17 2021, Tega, Update, Computer Scripts / Programs, Temperature sensors added to the summary pages
|
Thu Sep 16 00:00:20 2021, Koji, Update, General, RIO Planex 1064 Lasers in the south cabinet
|
Wed Sep 1 21:55:14 2021, Koji, Summary, General, Towards the end upgrade
|
Wed Sep 15 23:53:54 2021, Koji, Summary, General, Towards the end upgrade  
|
Wed Sep 15 23:38:32 2021, Koji, Update, ALS, ALS ASX PZT HV was off -> restored
|
Fri Mar 19 19:15:13 2021, Jon, Update, CDS, c1auxey assembly
|
Thu Mar 25 12:11:53 2021, Yehonathan, Update, CDS, c1auxey assembly 
|
Thu Mar 25 14:16:33 2021, gautam, Update, CDS, c1auxey assembly
|
Tue Mar 30 17:27:04 2021, Yehonathan, Update, CDS, c1auxey assembly
|
Wed Aug 25 11:48:48 2021, Yehonathan, Update, CDS, c1auxey assembly
|
Mon Sep 13 14:32:25 2021, Yehonathan, Update, CDS, c1auxey assembly
|
Wed Sep 15 11:27:50 2021, Yehonathan, Update, CDS, c1auxey assembly 
|
Thu Apr 15 17:24:08 2021, Jon, Update, CDS, Updated c1auxey wiring plan
|
Mon Apr 19 21:54:55 2021, Yehonathan, Update, CDS, Updated c1auxey wiring plan
|
Wed Apr 28 18:56:57 2021, Yehonathan, Jon, Update, CDS, Updated c1auxey wiring plan
|
Thu Apr 29 16:35:51 2021, Yehonathan, Update, CDS, Updated c1auxey wiring plan
|
Thu Apr 29 19:55:45 2021, Yehonathan, Update, CDS, Updated c1auxey wiring plan
|
Fri Apr 30 19:18:51 2021, Yehonathan, Jon, Update, CDS, Updated c1auxey wiring plan
|
Mon May 3 20:36:46 2021, Yehonathan, Jon, Update, CDS, Updated c1auxey wiring plan
|
Sun May 23 18:28:54 2021, Jon, Update, CDS, Opto-isolator for c1auxey
|
Fri May 28 10:54:59 2021, Jon, Update, CDS, Opto-isolator for c1auxey
|
Thu Jun 3 17:15:17 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey 
|
Thu Jun 3 22:08:00 2021, Koji, Update, CDS, Opto-isolator for c1auxey
|
Fri Jun 4 14:49:23 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
Fri Jun 4 17:46:25 2021, unYehonathan, Update, CDS, Opto-isolator for c1auxey
|
Sun Jun 6 16:33:47 2021, Jon, Update, CDS, BI channels on c1auxey
|
Mon Jun 7 13:14:20 2021, Yehonathan, Update, CDS, BI channels on c1auxey
|
Tue Jun 8 11:54:39 2021, Yehonathan, Update, CDS, BI channels on c1auxey
|
Sun Jun 6 03:02:14 2021, Koji, Update, CDS, Opto-isolator for c1auxey
|
Sun Jun 6 12:15:16 2021, Jon, Update, CDS, Opto-isolator for c1auxey
|
Sun Jun 6 15:59:51 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
Mon Jun 14 15:31:30 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
Tue Jun 15 21:48:55 2021, Koji, Update, CDS, Opto-isolator for c1auxey
|
Wed Jun 16 17:24:29 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
Wed Jun 16 20:32:39 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
Fri Jul 9 18:35:32 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
Mon Jul 12 18:06:25 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
Wed Jul 28 12:47:52 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey  
|
Wed Aug 11 12:06:40 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
Tue Sep 14 17:19:38 2021, Paco, Summary, PEM, Excess seismic noise in 0.1 - 0.3 Hz band
|
Tue Sep 14 19:12:03 2021, Koji, Summary, PEM, Excess seismic noise in 0.1 - 0.3 Hz band 
|
Tue Sep 14 15:57:05 2021, jamie, Frogs, CDS, fb1 /var full after reboot, caused all sorts of problems
|
Tue Sep 14 16:44:54 2021, jamie, Frogs, CDS, fb1 /var full after reboot, caused all sorts of problems
|
Tue Sep 14 17:22:21 2021, Anchal, Update, CDS, Added temp sensor channels to DAQ list
|
Tue Sep 14 16:12:03 2021, Jordan, Update, SUS, SOS Tower Hardware
|
Tue Sep 14 17:14:46 2021, Koji, Update, SUS, SOS Tower Hardware
|
Mon Sep 13 18:19:25 2021, Tega, Update, Computer Scripts / Programs, Moved modbus service from chiara to c1susaux
|
Mon Sep 13 17:05:04 2021, Tega, Summary, PEM, Infrasensing temperature sensor modbus configuration
|
Wed Aug 4 18:19:26 2021, paco, Update, General, Added infrasensing temperature unit to martian network
|
Thu Aug 5 14:59:31 2021, Anchal, Update, General, Added temperature sensors at Yend and Vertex too
|
Tue Aug 10 17:24:26 2021, paco, Update, General, Five day trend
|
Mon Sep 13 04:12:01 2021, Tega, Update, General, Added temperature sensors at Yend and Vertex too
|
Fri Jun 11 20:19:50 2021, Koji, Summary, BHD, BHD OMC invacuum wiring
|
Thu Sep 9 09:54:41 2021, Stephen, Summary, BHD, BHD OMC invacuum wiring - cable lengths  
|
Wed Sep 8 19:06:14 2021, Koji, Update, General, Backup situation
|
Wed Sep 8 18:00:01 2021, Koji, Update, VAC, cronjobs & N2 pressure alert
|
Thu Sep 2 17:53:15 2021, Paco, Summary, Computers, chiara down, vac interlock tripped
|
Thu Sep 2 21:21:14 2021, Koji, Summary, Computers, Vacuum recovery 2 
|
Thu Sep 2 21:49:03 2021, Paco, Summary, Computers, chiara down, vac interlock tripped
|
Fri Sep 3 02:03:15 2021, Tega, Summary, Computers, Strip down large error files
|
Thu Sep 2 19:28:02 2021, Koji, Update, , This week's FB1 GPS Timing Issue Solved
|
Thu Sep 2 19:47:38 2021, Koji, Update, CDS, This week's FB1 GPS Timing Issue Solved
|
Thu Sep 2 20:44:18 2021, Koji, Update, CDS, Chiara DHCP restarted
|
Thu Sep 2 20:47:19 2021, Koji, Update, CDS, Chiara DHCP restarted
|
Wed Sep 1 14:16:21 2021, Jordan, Update, VAC, Empty N2 Tanks
|
Mon Aug 30 17:49:43 2021, Paco, Summary, LSC, XARM POX OLTF 
|
Tue Aug 31 14:55:24 2021, rana, Summary, LSC, XARM POX OLTF
|
Thu Aug 26 10:30:14 2021, Jamie, Configuration, CDS, front end time synchronization fixed?
|
Tue Aug 24 18:44:03 2021, Koji, Update, CDS, FB is writing the frames with a year old date
|
Wed Aug 25 17:31:30 2021, Paco, Update, CDS, FB is writing the frames with a year old date 
|
Thu Aug 26 10:10:44 2021, Paco, Update, CDS, FB is writing the frames with a year old date 
|
Wed Aug 25 18:20:21 2021, Jamie, Update, CDS, GPS time on fb1 fixed, dadq writing correct frames again
|
Wed Aug 25 08:53:33 2021, Jordan, Update, SUS, 2" Adapter Ring for SOS Arrived 8/24/21  
|
Wed Feb 24 22:13:47 2021, Jon, Update, CDS, Planning document for front-end testing
|
Fri Mar 5 17:48:25 2021, Jon, Update, CDS, Front-end testing  
|
Tue Mar 9 16:52:47 2021, Jon, Update, CDS, Front-end testing
|
Tue Mar 16 16:27:22 2021, Jon, Update, CDS, Front-end testing
|
Tue Mar 16 19:04:20 2021, gautam, Update, CDS, Front-end testing
|
Fri Mar 19 18:14:56 2021, Jon, Update, CDS, Front-end testing 
|
Wed Mar 24 19:02:21 2021, Jon, Update, CDS, Front-end testing
|
Mon Mar 29 17:55:50 2021, Jon, Update, CDS, Front-end testing
|
Tue Mar 30 18:21:34 2021, Jon, Update, CDS, Front-end testing
|
Tue Apr 6 07:19:11 2021, Jon, Update, CDS, New SimPlant cymac
|
Tue Apr 6 11:13:01 2021, Jon, Update, CDS, FE testing
|
Sat Apr 10 08:51:32 2021, Jon, Update, CDS, I/O Chassis Assembly
|
Thu Apr 29 10:51:35 2021, Jon, Update, CDS, I/O Chassis Assembly
|
Tue May 4 07:38:36 2021, Jon, Update, CDS, I/O Chassis Assembly
|
Tue May 11 16:29:55 2021, Jon, Update, CDS, I/O Chassis Assembly
|
Tue May 11 17:43:09 2021, Koji, Update, CDS, I/O Chassis Assembly
|
Fri May 28 11:16:21 2021, Jon, Update, CDS, Front-End Assembly and Testing   
|
Sun Jun 6 08:42:05 2021, Jon, Update, CDS, Front-End Assembly and Testing  
|
Tue Jun 22 16:53:01 2021, Ian MacMillan, Update, CDS, Front-End Assembly and Testing
|
Thu Jun 24 17:32:52 2021, Ian MacMillan, Update, CDS, Front-End Assembly and Testing  
|
Fri Jun 25 14:06:10 2021, Jon, Update, CDS, Front-End Assembly and Testing
|
Sat Apr 10 11:56:14 2021, Jon, Update, CDS, 40m LSC simPlant model
|
Tue Apr 13 16:24:38 2021, Ian MacMillan, Update, CDS, 40m LSC simPlant model
|
Mon Apr 19 13:15:20 2021, Ian MacMillan, Update, CDS, 40m LSC simPlant model
|
Wed Apr 21 10:03:01 2021, Ian MacMillan, Update, CDS, 40m LSC simPlant model
|
Wed Apr 21 11:01:37 2021, Rana, Update, CDS, 40m LSC simPlant model
|
Fri Apr 23 15:52:19 2021, Ian MacMillan, Update, CDS, 40m LSC simPlant model  
|
Sun Apr 25 21:21:02 2021, rana, Update, CDS, SUS simPlant model
|
Tue Apr 27 15:15:17 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
|
Thu Apr 29 13:41:40 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Fri Apr 30 12:52:14 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Mon May 3 13:35:12 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Tue May 4 14:55:38 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Wed May 5 15:11:54 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Thu May 6 16:13:24 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Fri May 7 11:19:29 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Wed May 12 13:06:15 2021, Ian MacMillan, Update, CDS, SUS simPlant model   
|
Fri May 21 09:44:52 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Fri May 21 14:36:20 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Thu Jun 3 13:06:47 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
|
Mon Jun 7 17:49:19 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
|
Wed Jun 9 13:50:48 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Tue Jun 15 11:46:40 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
|
Wed Jun 30 14:09:26 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
|
Mon Aug 23 15:25:59 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Mon Aug 23 10:17:21 2021, Paco, Summary, Computers, system reboot glitch
|
Mon Aug 16 23:30:34 2021, Paco, Update, CDS, AS WFS commissioning; restarting models
|
Thu Aug 19 03:23:00 2021, Anchal, Update, CDS, Time synchornization not running
|
Thu Aug 19 14:14:49 2021, Koji, Update, CDS, Time synchornization not running
|
Fri Aug 20 00:28:55 2021, Anchal, Update, CDS, Time synchornization not running
|
Fri Aug 20 06:24:18 2021, Anchal, Update, CDS, Time synchornization not running
|
Wed Aug 18 20:30:12 2021, Anchal, Update, ASS, Fixed runASS scripts
|
Fri May 21 00:05:45 2021, Koji, Update, SUS, New electronics: Sat Amp / Coil Drivers
|
Thu Jun 17 22:25:38 2021, Koji, Update, SUS, New electronics: Sat Amp / Coil Drivers
|
Wed Jul 21 14:50:23 2021, Koji, Update, SUS, New electronics 
|
Tue Aug 17 04:30:35 2021, Koji, Update, SUS, New electronics  
|
Thu Aug 12 11:04:27 2021, Paco, Update, General, PSL shutter was closed this morning
|
Thu Aug 12 14:59:25 2021, Koji, Update, General, PSL shutter was closed this morning
|
Thu Aug 12 20:52:04 2021, Koji, Update, General, PSL shutter was closed this morning 
|
Wed Aug 11 11:35:36 2021, Paco, Update, LSC, PRMI MICH orthogonality plan
|
Fri Aug 6 13:13:28 2021, Anchal, Update, BHD, c1teststand subnetwork now accessible remotely
|
Mon Aug 9 10:38:48 2021, Anchal, Update, BHD, c1teststand subnetwork now accessible remotely
|
Fri Aug 6 17:10:19 2021, Paco, Update, IMC, MC rollercoaster
|
Tue Aug 3 20:20:08 2021, Anchal, Update, Optical Levers, Recentered ETMX, ITMX and ETMY oplevs at good state
|
Mon Aug 2 16:18:23 2021, Paco, Update, ASC, AS WFS MICH commissioning
|
Thu Jul 29 14:51:39 2021, Paco, Update, Optical Levers, Recenter OpLevs
|
Wed Jul 28 20:20:09 2021, Yehonathan, Update, General, The temperature sensors and function generator have arrived in the lab 
|
Wed Mar 24 00:51:19 2021, gautam, Update, LSC, Schnupp asymmetry
|
Wed Jul 28 17:10:24 2021, Anchal, Update, LSC, Schnupp asymmetry
|
Tue Jul 27 23:04:37 2021, Anchal, Update, LSC, 40 meter party
|
Wed Jul 21 18:08:35 2021, yehonathan, Update, Loss Measurement, Loss measurement
|
Thu Jul 22 16:06:10 2021, Paco, Update, Loss Measurement, Loss measurement
|
Sun Jul 25 20:41:47 2021, rana, Update, Loss Measurement, Loss measurement
|
Mon Jul 26 17:34:23 2021, Paco, Update, Loss Measurement, Loss measurement  
|
Sat Jul 17 00:52:33 2021, Koji, Update, General, Canon camera / small silver tripod / macro zoom lens / LED ring light borrowed -> QIL
|
Sun Jul 25 18:21:10 2021, Koji, Update, General, Canon camera / small silver tripod / macro zoom lens / LED ring light returned / Electronics borrowed
|
Mon Jul 19 22:16:08 2021, paco, Update, LSC, PRFPMI locking
|
Fri Jul 16 16:26:50 2021, gautam, Update, Computers, Docker installed on nodus
|
Wed Jul 14 20:42:04 2021, gautam, Update, LSC, Locking
|
Thu Jul 15 14:25:48 2021, Paco, Update, LSC, CM board
|
Wed Jun 16 19:34:18 2021, Koji, Update, General, HVAC    
|
Wed Jul 14 16:19:44 2021, gautam, Update, General, Brrr
|
Wed Jul 14 19:21:44 2021, Koji, Update, General, Brrr
|
Tue May 25 17:42:11 2021, Anchal, Paco, Summary, ALS, ALS Single Arm Noise Budget 
|
Thu May 27 11:03:15 2021, Anchal, Paco, Summary, ALS, ALS Single Arm Noise Budget 
|
Fri May 28 17:32:48 2021, Anchal, Summary, ALS, Single Arm Actuation Calibration with IR ALS Beat 
|
Tue Jun 1 16:55:32 2021, Anchal, Paco, Summary, ALS, Single Arm Actuation Calibration with IR ALS Beat
|
Tue Jun 8 11:40:53 2021, Anchal, Paco, Summary, ALS, Single Arm Actuation Calibration with IR ALS Beat
|
Wed Jun 9 18:29:13 2021, Anchal, Paco, Summary, ALS, Check for saturation in ITMX SOS Driver
|
Fri Jul 9 15:39:08 2021, Anchal, Summary, ALS, Single Arm Actuation Calibration with IR ALS Beat [Correction]
|
Thu Jul 8 11:20:38 2021, Anchal, Paco, Gautam, Summary, LSC, PRFPMI locking attempts
|
Tue Jul 6 17:40:32 2021, Koji, Summary, General, Lab cleaning 7x
|
Tue Jul 6 10:47:07 2021, Paco, Anchal, Update, IOO, Restored MC
|
Tue Jul 6 16:35:04 2021, Anchal, Paco, Gautam, Update, IOO, Restored MC
|
Fri Jul 2 12:42:56 2021, Anchal, Paco, Gautam, Summary, LSC, snap file changed for MICH
|
Wed Jun 30 15:31:35 2021, Anchal, Summary, Optical Levers, Centered optical levers on ITMY, BS, PRM and ETMY
|
Thu Jul 1 16:55:21 2021, Anchal, Summary, Optical Levers, Fixed Centeringoptical levers PRM
|
Thu Jul 1 11:37:50 2021, Paco, Update, General, restarted c0rga
|
Wed Jun 30 18:44:11 2021, Anchal, Summary, LSC, Tried fixing ETMY QPD
|
Thu Jul 1 10:34:51 2021, Paco, Anchal, Summary, LSC, ETMY QPD fixed
|
Tue Jun 29 17:42:06 2021, Anchal, Paco, Gautam, Summary, LSC, MICH locking tutorial with Gautam
|
Sun Sep 6 14:17:18 2020, Jon, Update, Equipment loan, Zurich Instruments analyzer
|
Fri Jun 25 19:14:45 2021, Jon, Update, Equipment loan, Zurich Instruments analyzer
|
Mon Dec 7 11:25:31 2020, gautam, Update, SUS, MC1 suspension glitchy again
|
Wed Dec 9 16:22:57 2020, gautam, Update, SUS, Yet another round of Sat. Box. switcharoo  
|
Sun Jan 3 16:26:06 2021, Koji, Update, SUS, IMC WFS check (Yet another round of Sat. Box. switcharoo)
|
Thu May 13 11:55:04 2021, Anchal, Paco, Update, SUS, MC1 suspension misbehaving 
|
Thu May 13 19:38:54 2021, Anchal, Update, SUS, MC1 Satellite Amplifier Debugged
|
Mon May 24 19:14:15 2021, Anchal, Paco, Summary, SUS, MC1 Free Swing Test set to trigger
|
Tue May 25 10:22:16 2021, Anchal, Paco, Summary, SUS, MC1 new input matrix calculated and uploaded
|
Thu Jun 17 11:45:42 2021, Anchal, Paco, Update, SUS, MC1 Gave trouble again 
|
Thu Jun 17 16:37:23 2021, Anchal, Paco, Update, SUS, c1susaux computer rebooted
|
Tue Jun 22 11:56:16 2021, Anchal, Paco, Update, SUS, ADC/Slow channels issues
|
Tue Jun 22 16:52:28 2021, Paco, Update, SUS, ADC/Slow channels issues
|
Wed Jun 23 09:05:02 2021, Anchal, Update, SUS, MC lock acquired back again
|
Thu Jun 24 16:40:37 2021, Koji, Update, SUS, MC lock acquired back again
|
Thu Jun 17 11:19:37 2021, Ian MacMillan, Update, CDS, CDS Upgrade
|
Mon Jun 21 17:15:49 2021, Ian MacMillan, Update, CDS, CDS Upgrade
|
Fri Jun 18 14:53:37 2021, Anchal, Summary, PEM, Temperature sensor network proposal
|
Wed Jun 9 11:46:01 2021, Anchal, Paco, Summary, AUX, Xend Green Laser PDH OLTF measurement  
|
Thu Jun 10 14:01:36 2021, Anchal, Summary, AUX, Xend Green Laser PDH OLTF measurement loop algebra
|
Mon Jun 14 18:57:49 2021, Anchal, Update, AUX, Xend is unbearably hot. Green laser is loosing lock in 10's of seconds 
|
Tue Jun 15 15:26:43 2021, Anchal, Paco, Summary, AUX, Xend Green Laser PDH OLTF measurement loop algebra, excitation at control point
|
Fri Jun 18 10:07:23 2021, Anchal, Paco, Summary, AUX, Xend Green Laser PDH OLTF with coherence 
|
Thu Jun 17 22:19:12 2021, Koji, Update, Electronics, 25 HAM-A coil driver units delivered
|
Mon Jun 7 15:37:01 2021, Anchal, Paco, Yehonathan, Summary, Cameras, Mon 7 in Control Room Died
|
Wed Jun 16 13:20:19 2021, Anchal, Paco, Summary, Cameras, Mon 7 in Control Room Replaced
|
Wed Jun 2 17:50:50 2021, Paco, Update, Equipment loan, Borrow red cart
|
Thu Jun 3 17:49:46 2021, Paco, Update, Equipment loan, Borrow red cart
|
Wed Mar 10 11:46:22 2021, Paco, Anchal, Summary, IMC, IMC free swinging prep
|
Wed Mar 10 15:00:16 2021, gautam, Summary, IMC, IMC free swinging prep
|
Wed Mar 10 15:29:58 2021, Anchal, Summary, IMC, IMC free swinging prep
|
Thu Jun 3 17:35:31 2021, Anchal, Summary, IMC, Fixed medm button
|
Wed Mar 10 15:35:25 2021, Paco, Anchal, Summary, IMC, IMC free swinging experiment set to trigger at 5:00 am
|
Mon Mar 8 12:01:02 2021, Paco, Anchal, Summary, training, Investigate how-to XARM locking
|
Mon Mar 8 12:40:35 2021, gautam, Summary, training, Investigate how-to XARM locking
|
Mon Mar 8 19:22:56 2021, rana, Summary, SUS, IMC suspension characterization
|
Thu Mar 11 08:13:24 2021, Paco, Anchal, Update, SUS, IMC First Free Swing Test failed due to typo, restarting now
|
Tue Mar 16 19:13:09 2021, Paco, Anchal, Update, SUS, First success in Input Matric Diagonalization 
|
Wed Mar 17 11:57:54 2021, Paco, Anchal, Update, SUS, Tested New Input Matrix for MC1 
|
Wed Mar 17 16:30:46 2021, Anchal, Update, SUS, Normalized Input Matrices plotted better than SURF students 
|
Thu Mar 18 09:18:49 2021, Paco, Anchal, Update, SUS, Testing of new input matrices with new data 
|
Thu Mar 18 12:46:53 2021, rana, Update, SUS, Testing of new input matrices with new data
|
Fri Mar 19 10:49:44 2021, Paco, Anchal, Update, SUS, Trying coil actuation balance
|
Mon Mar 22 11:57:21 2021, Paco, Anchal, Update, SUS, Trying coil actuation balance 
|
Mon Mar 22 15:10:00 2021, rana, Update, SUS, Trying coil actuation balance
|
Mon Mar 22 19:07:50 2021, Paco, Anchal, Update, SUS, Trying coil actuation balance 8x
|
Tue Mar 23 09:16:42 2021, Paco, Anchal, Update, Computers, Power cycled C1PSL; restored C1PSL 
|
Wed Mar 24 09:23:49 2021, Paco, Update, SUS, MC3 new Input Matrix
|
Thu Mar 25 11:46:31 2021, Paco, Anchal, Update, SUS, MC2 Coil Balancing updates   
|
Thu Mar 25 15:31:24 2021, gautam, Update, IOO, WFS servos
|
Fri Mar 26 11:54:37 2021, Paco, Anchal, Update, SUS, MC2 Coil Balancing updates
|
Mon Mar 29 10:44:51 2021, Paco, Anchal, Update, SUS, MC2 Coil Balancing updates 
|
Mon Mar 29 17:11:54 2021, gautam, Update, SUS, MC2 Coil Balancing updates
|
Mon Mar 29 17:34:52 2021, rana, Update, SUS, MC2 Coil Balancing updates
|
Wed Mar 31 22:58:32 2021, Anchal, Paco, Update, SUS, MC2 Coil Balancing Test
|
Thu Apr 1 13:56:49 2021, Anchal, Paco, Update, SUS, MC2 Coil Balancing Test Results  
|
Thu Apr 1 18:01:06 2021, Anchal, Paco, Update, SUS, MC2 Coil Balancing Test Results Success??  
|
Thu Apr 1 18:48:45 2021, gautam, Update, SUS, MC2 Coil Balancing Test Results Success??
|
Thu Apr 1 21:13:54 2021, Anchal, Update, SUS, Matrix results, new measurement set to trigger
|
Fri Apr 2 14:51:20 2021, Anchal, Update, SUS, Bug found, need to redo the balancing
|
Tue Apr 6 18:46:36 2021, Anchal, Paco, Update, SUS, Updates on recent efforts
|
Wed Apr 7 17:38:51 2021, Anchal, Update, SUS, Trying to uncouple only PIT and YAW first    
|
Thu Apr 8 17:04:43 2021, Anchal, Paco, Update, SUS, First Successful Coil Balancing  
|
Fri Apr 9 13:13:00 2021, Anchal, Paco, Update, SUS, Faster coil balancing 
|
Fri Apr 9 17:41:12 2021, rana, Update, SUS, Faster coil balancing
|
Mon Apr 12 10:07:35 2021, Anchal, Update, SUS, What's F2A??
|
Tue Apr 13 09:51:22 2021, rana, Update, SUS, What's F2A??
|
Wed Apr 14 17:53:38 2021, Anchal, Update, SUS, Plan for calculating filter banks for output matrix aka F2A aka F2P
|
Thu Apr 15 11:41:43 2021, Anchal, Update, SUS, Proposed filters for output matrix aka F2A aka F2P
|
Fri Apr 16 11:36:36 2021, Anchal, Paco, Update, SUS, Tested proposed filters for POS colum in MC2 output matrix    
|
Fri Apr 16 15:47:58 2021, rana, Update, SUS, Tested proposed filters for POS colum in MC2 output matrix
|
Mon Apr 19 12:18:19 2021, Anchal, Paco, Update, SUS, Tested proposed filters for POS colum in MC2 output matrix  
|
Tue Apr 20 10:52:49 2021, Anchal, Paco, Update, SUS, AC gain coil output balancing for IMC   
|
Tue Apr 20 18:19:30 2021, Anchal, Update, SUS, MC2 coil balanced at DC  
|
Wed Apr 21 11:38:27 2021, Anchal, Paco, Update, SUS, MC2 Damping Gains Optimized 
|
Wed Apr 21 15:50:01 2021, Anchal, Paco, Update, SUS, MC2 Suspension Optimization summary
|
Wed Apr 21 18:49:29 2021, rana, Update, SUS, MC2 Suspension Optimization summary
|
Thu Apr 22 08:50:21 2021, Anchal, Update, SUS, MC2 Suspension Optimization summary
|
Mon Apr 26 18:55:39 2021, Anchal, Paco, Update, SUS, MC2 F2A Filters Tested  
|
Tue Apr 27 10:05:28 2021, Anchal, Paco, Update, SUS, MC1 and MC3 F2A Filters Tested   
|
Wed Apr 28 10:56:10 2021, Anchal, Paco, Update, SUS, IMC Filters diagnosed 7x
|
Wed Apr 28 17:09:11 2021, Anchal, Update, SUS, Tuned Suspension Parameters uploaded for long term behavior monitoring
|
Thu Apr 29 10:52:56 2021, Anchal, Update, SUS, IMC Trans QPD and WFS loops step response test 
|
Thu Apr 29 18:53:33 2021, Anchal, Update, SUS, IMC Suspension Damping Gains Test  
|
Mon May 3 16:24:14 2021, Anchal, Update, SUS, IMC Suspension Damping Gains Test Repeated with IMC unlocked  
|
Wed May 5 09:04:47 2021, Anchal, Update, SUS, New IMC Suspension Damping Gains uploaded for long term testing
|
Wed May 12 11:45:13 2021, Anchal, Paco, Summary, SUS, New IMC Settings are miserable  
|
Wed Jun 2 09:43:30 2021, Anchal, Paco, Summary, SUS, IMC Settings characterization   
|
Wed Jun 2 16:20:59 2021, Anchal, Paco, Summary, SUS, IMC Suspension gains reverted to old values
|
Sat May 15 14:54:24 2021, gautam, Update, SUS, IMC settings reverted
|
Thu May 20 10:35:57 2021, Anchal, Update, SUS, IMC settings reverted
|
Thu Apr 22 12:17:23 2021, Anchal, Paco, Update, SUS, MC1 and MC3 Suspension Optimization Summary
|
Thu Apr 22 14:22:39 2021, gautam, Update, SUS, Settings restored
|
Thu Apr 22 15:36:54 2021, Anchal, Update, SUS, Settings restored
|
Thu Apr 22 17:04:17 2021, gautam, Update, SUS, Settings restored
|
Sat Apr 10 10:07:47 2021, rana, Update, SUS, Faster coil balancing
|
Fri Apr 2 15:22:54 2021, gautam, Update, SUS, Matrix results, new measurement set to trigger
|
Sun Mar 28 14:16:25 2021, Anchal, Summary, SUS, MC3 new Input Matrix not providing stable loop
|
Mon Mar 29 17:07:17 2021, gautam, Summary, SUS, MC3 new Input Matrix not providing stable loop
|
Thu Mar 18 13:12:39 2021, gautam, Update, Computer Scripts / Programs, Omnigraffle vs draw.io
|
Thu May 27 14:11:15 2021, Jordan, Update, SUS, CoM to Clamping Point Measurement for 3" Adapter Ring 
|
Tue Jun 1 14:26:23 2021, Jordan, Update, SUS, CoM to Clamping Point Measurement for 3" Adapter Ring
|
Wed Jun 2 01:08:57 2021, Koji, Update, SUS, CoM to Clamping Point Measurement for 3" Adapter Ring
|
Wed May 26 11:45:57 2021, Anchal, Paco, Configuration, IMC, MC2 analog camera
|
Wed May 26 02:00:44 2021, gautam, Update, Electronics, Coil driver noise 
|
Tue May 25 17:08:17 2021, Chub, Update, Electronics, chassis rework complete!
|
Mon May 24 20:55:00 2021, Koji, Summary, BHD, How to align two OMCs on the BHD platform?
|
Mon May 24 10:19:54 2021, Paco, Update, General, Zita IOO strip 
|
Mon May 24 08:38:26 2021, Chub, Update, Electronics, 18-bit AI, 16-bit AI and 16-bit AA
|
Fri May 21 12:12:11 2021, Paco, Update, NoiseBudget, AUX PDH loop identification
|
Fri May 21 00:15:33 2021, Koji, Update, Electronics, DC Power Strip delivered / stored 9x
|
Thu Aug 20 00:21:51 2020, gautam, Update, Electronics, First look at HV coil driver  
|
Sun Aug 23 23:36:58 2020, gautam, Update, Electronics, First look at HV coil driver 
|
Wed Aug 26 16:12:25 2020, gautam, Update, Electronics, Test mass coil current requirements
|
Tue Sep 1 15:39:04 2020, gautam, Update, Electronics, HV coil driver oscillations fixed 
|
Thu Oct 22 11:14:47 2020, gautam, Update, Electronics, HV coil driver packaged into 2U chassis  
|
Thu Oct 22 13:04:42 2020, rana, Update, Electronics, HV coil driver packaged into 2U chassis
|
Thu Oct 22 22:01:53 2020, gautam, Update, Electronics, HV coil driver packaged into 2U chassis 
|
Fri Oct 23 09:03:43 2020, anchal, Update, Electronics, HV coil driver packaged into 2U chassis
|
Thu Nov 12 14:55:35 2020, gautam, Update, Electronics, More systematic noise characterization 
|
Thu Nov 12 15:40:42 2020, Koji, Update, Electronics, More systematic noise characterization
|
Mon Nov 16 00:02:34 2020, rana, Update, Electronics, More systematic noise characterization
|
Wed Jan 20 10:13:06 2021, gautam, Update, Electronics, HV Power supply bypassing    
|
Mon Feb 1 12:30:21 2021, gautam, Update, Electronics, More careful characterization  
|
Wed Feb 10 21:14:03 2021, gautam, Update, Electronics, Production version of the HV coil driver tested   
|
Fri Feb 26 16:31:02 2021, gautam, Update, Electronics, Production version of the HV coil driver tested with KEPCO HV supplies
|
Fri Feb 26 20:20:43 2021, Koji, Update, Electronics, Production version of the HV coil driver tested with KEPCO HV supplies
|
Sat Feb 27 17:25:42 2021, gautam, Update, Electronics, Production version of the HV coil driver tested with KEPCO HV supplies
|
Thu May 20 16:56:21 2021, Koji, Update, Electronics, Production version of the HV coil driver tested with KEPCO HV supplies
|
Wed May 12 14:23:20 2021, Jordan, Update, SUS, Mass Properties of SOS Assembly with 3"->2" Optic sleeve, in SI units
|
Wed May 12 16:53:59 2021, Koji, Update, SUS, Mass Properties of SOS Assembly with 3"->2" Optic sleeve, in SI units
|
Wed May 12 17:06:52 2021, Jordan, Update, SUS, Mass Properties of SOS Assembly with 3"->2" Optic sleeve, in SI units
|
Wed May 19 18:29:41 2021, Koji, Update, SUS, Mass Properties of SOS Assembly with 3"->2" Optic sleeve, in SI units 
|
Wed Apr 21 19:28:03 2021, Anchal, Update, PSL, PSL/IFO recovery
|
Wed Apr 21 19:43:20 2021, Koji, Update, PSL, New HEPA speed control 
|
Thu Apr 22 14:41:55 2021, Chub, Update, PSL, New HEPA speed control
|
Fri Apr 23 18:00:02 2021, gautam, Update, PSL, HEPA speed lowered
|
Fri Apr 23 19:26:58 2021, Koji, Update, PSL, HEPA speed lowered
|
Fri May 14 17:45:05 2021, rana, Update, PSL, HEPA speed raised
|
Tue May 18 00:52:38 2021, rana, Update, PSL, HEPA speed raised
|
Tue May 18 20:26:11 2021, rana, Update, PSL, HEPA speed raised
|
Thu Apr 22 15:15:26 2021, gautam, Update, PSL, PMC transmission
|
Thu Apr 22 15:34:54 2021, Anchal, Update, PSL, PMC transmission
|
Sat May 15 12:39:54 2021, gautam, Update, PSL, NPRO tripped/switched off
|
Fri May 14 03:29:50 2021, Koji, Update, Electronics, HV Driver noise test with the new HV power supply from Matsusada
|
Thu Apr 29 11:51:27 2021, Anchal, Summary, LSC, Start of measuring IMC WFS noise contribution in ar cavity length noise
|
Thu Apr 29 15:11:33 2021, gautam, Update, CDS, RFM 
|
Thu Apr 29 17:43:16 2021, Koji, Update, CDS, RFM
|
Thu Apr 29 17:43:48 2021, Anchal, Update, CDS, F2A Filters double check
|
Fri Apr 30 00:20:30 2021, gautam, Update, CDS, F2A Filters double check
|
Thu Apr 29 17:51:19 2021, Anchal, Summary, LSC, Start of measuring IMC WFS noise contribution in arm cavity length noise
|
Fri Apr 30 00:18:40 2021, gautam, Summary, LSC, Start of measuring IMC WFS noise contribution in arm cavity length noise
|
Mon May 3 09:14:01 2021, Anchal, Paco, Update, LSC, IMC WFS noise contribution in arm cavity length noise 
|
Mon May 3 17:28:58 2021, Anchal, Paco, Rana, Update, LSC, IMC WFS noise contribution in arm cavity length noise 
|
Tue May 4 11:43:09 2021, Anchal, Paco, Update, LSC, IMC WFS noise contribution in arm cavity length noise  
|
Fri May 7 11:54:02 2021, Anchal, Paco, Update, LSC, IMC WFS noise contribution in arm cavity length noise  
|
Mon May 10 18:19:12 2021, Anchal, Paco, Update, LSC, IMC WFS noise contribution in arm cavity length noise, Corrections
|
Wed May 12 10:53:20 2021, Anchal, Paco, Update, LSC, PSL-IMC PDH Loop and XARM PDH Loop diagram
|
Mon May 10 10:57:54 2021, Anchal, Paco, Summary, Calibration, Using ALS beatnote for calibration, test  
|
Thu May 6 16:13:39 2021, Anchal, Summary, IMC, Angular actuation calibration for IMC mirrors
|
Wed May 5 13:05:07 2021, Chub, Update, General, chassis delivery from De Leone
|
Mon May 3 18:59:58 2021, Anchal, Summary, General, Weird gas leakagr kind of noise in 40m control room
|
Mon May 3 23:28:56 2021, Koji, Summary, General, Weird gas leakagr kind of noise in 40m control room
|
Mon Apr 19 09:17:51 2021, Jordan, Update, VAC, Empty N2 Tanks
|
Wed Apr 21 12:56:00 2021, Jordan, Update, VAC, Empty N2 Tanks
|
Wed Apr 28 11:31:40 2021, Jon, Update, VAC, Empty N2 Tanks
|
Mon Apr 26 18:52:52 2021, Anchal, Paco, HowTo, Computer Scripts / Programs, awg free slot
|
Tue Apr 13 20:45:16 2021, Yehonathan, Update, PSL, Laser amplifier   
|
Wed Apr 14 19:48:18 2021, gautam, Update, PSL, Laser amplifier
|
Thu Apr 15 09:46:24 2021, Yehonathan, Update, PSL, Laser amplifier
|
Fri Apr 16 18:21:36 2021, Yehonathan, Update, PSL, Laser amplifier   
|
Sun Apr 18 21:29:55 2021, rana, Update, PSL, Laser amplifier
|
Wed Apr 21 11:09:57 2021, yehonathan, Update, PSL, Laser amplifier    
|
Thu Apr 22 17:28:34 2021, Yehonathan, Update, PSL, Laser amplifier  
|
Thu Apr 22 14:49:08 2021, gautam, Update, Computer Scripts / Programs, rossa added to RTS authorized keys
|
Thu Apr 22 01:42:38 2021, Koji, Summary, Electronics, HV Supply Comparison   
|
Wed Apr 21 05:48:47 2021, Chub, Update, General, PSL HEPA Maintenance
|
Wed Apr 21 13:10:12 2021, Koji, Update, General, PSL HEPA Maintenance
|
Wed Apr 21 10:59:07 2021, rana, Summary, Cameras, note on new GigE cam @ 1064
|
Wed Apr 21 00:08:15 2021, Koji, Update, PSL, PSL Table (sort of) covered / HEPA "chimney"   
|
Wed Apr 21 01:14:03 2021, Koji, Update, PSL, PSL Table (sort of) covered / HEPA "chimney"  
|
Fri Apr 16 00:21:52 2021, Koji, Update, General, Glue Freezer completely frozen 
|
Fri Apr 16 10:58:16 2021, Yehonathan, Update, General, Glue Freezer completely frozen
|
Fri Apr 16 19:07:31 2021, Yehonathan, Update, General, Glue Freezer completely frozen
|
Mon Apr 19 10:52:27 2021, Yehonathan, Update, General, Glue Freezer completely frozen
|
Mon Apr 19 19:40:54 2021, Yehonathan, Update, General, Glue Freezer completely frozen
|
Fri Apr 16 11:31:00 2021, rana, Update, elog, elog stuck ~10 AM today
|
Thu Apr 15 18:33:39 2021, Koji, Update, CDS, More 16bit ADC adapter boards
|
Wed Apr 7 22:48:48 2021, gautam, Update, IOO, Waveplate commissioning
|
Tue Apr 13 17:47:07 2021, gautam, Update, IOO, Waveplate commissioning - software prepared
|
Thu Apr 15 15:54:46 2021, gautam, Update, IOO, Waveplate commissioning - hardware installed
|
Wed Apr 14 23:55:34 2021, gautam, Update, Electronics, HV Coil driver assembly
|
Wed Apr 14 14:52:42 2021, gautam, Update, General, IFO State
|
Wed Apr 14 16:46:24 2021, Anchal, Update, General, IFO State
|
Wed Apr 14 12:27:10 2021, gautam, Update, General, Lab left open again
|
Wed Apr 14 13:12:13 2021, Anchal, Update, General, Sorry, it was me
|
Wed Apr 14 15:30:29 2021, rana, Update, General, Sorry, it was me
|
Wed Mar 17 09:05:01 2021, Paco, Anchal, Configuration, Computers, 40m Control Room Changes
|
Wed Apr 14 13:16:20 2021, Anchal, Configuration, Computers, 40m Control Room Changes
|
Tue Apr 13 19:24:45 2021, gautam, Update, PSL, High power operations 
|
Mon Apr 12 08:32:54 2021, Anchal, Paco, Summary, PSL, PMC unlocked at 2pm on Sunday; ~ Restored
|
Mon Apr 12 18:34:26 2021, Yehonathan, Summary, PSL, PMC unlocked at 2pm on Sunday; ~ Restored
|
Thu Apr 8 20:58:17 2021, Koji, Update, CDS, ADC adapter boards assembly
|
Wed Apr 7 13:07:03 2021, Jordan, Update, SUS, CoM on 3"->2" Adapter Ring for SOS 
|
Wed Apr 7 02:50:49 2021, Koji, Update, SUS, Flange Inspections
|
Thu Oct 15 20:00:23 2020, Koji, Summary, General, HEPA AC cord replacement   
|
Thu Apr 1 23:55:33 2021, Koji, Summary, General, HEPA AC cord replacement
|
Fri Apr 2 15:17:23 2021, gautam, Summary, General, HEPA AC cord replacement
|
Tue Apr 6 21:17:04 2021, Koji, Summary, General, PSL HEPA investigation  
|
Mon Apr 5 22:26:01 2021, gautam, Update, LSC, PRMI 1f locking (no ETMs) recovered
|
Mon Apr 5 08:25:59 2021, Anchal, Paco, Update, General, Restore MC from early quakes
|
Sat Apr 3 00:42:40 2021, gautam, Update, LSC, PRFPMI locking with half input power 
|
Fri Apr 2 01:26:41 2021, gautam, Update, Electronics, REFL55 chain checkout again, seems fine
|
Wed Mar 31 00:40:32 2021, Koji, Update, Electronics, Electronics Packaging for assembly work 
|
Thu Apr 1 18:16:28 2021, Koji, Update, Electronics, Electronics Packaging for assembly work
|
Thu Apr 1 00:50:06 2021, gautam, Update, SUS, PRMdiag
|
Thu Feb 18 20:24:48 2021, Koji, Summary, Electronics, A bunch of electronics received
|
Sat Feb 20 10:01:48 2021, gautam, Summary, Electronics, A bunch of electronics received
|
Sat Feb 20 16:46:17 2021, Koji, Summary, Electronics, A bunch of electronics received
|
Fri Mar 5 00:53:09 2021, Koji, Summary, Electronics, A bunch of electronics received
|
Fri Mar 5 15:03:28 2021, gautam, Summary, Electronics, A bunch of electronics received
|
Fri Mar 5 15:32:53 2021, Koji, Summary, Electronics, A bunch of electronics received
|
Wed Mar 31 03:56:37 2021, Koji, Summary, Electronics, A bunch of electronics received 
|
Wed Mar 24 15:24:13 2021, gautam, Update, LSC, Notes on tests
|
Wed Mar 24 22:54:49 2021, gautam, Update, LSC, New day, new problems  
|
Mon Mar 29 19:32:46 2021, gautam, Update, LSC, REFL55 whitening checkout
|
Thu Mar 25 18:05:04 2021, gautam, Update, Electronics, Stuffed HV coil drivers received from Screaming Circuits
|
Thu Mar 25 17:39:28 2021, gautam, Update, Computer Scripts / Programs, Spot position measurement scripts "modernized" 
|
Fri Mar 12 03:08:23 2021, Koji, Summary, SUS, Coil Rs & Ls for PRM/BS/SRM 
|
Fri Mar 12 12:32:54 2021, gautam, Summary, SUS, Coil Rs & Ls for PRM/BS/SRM 
|
Fri Mar 12 13:01:43 2021, rana, Summary, SUS, Coil Rs & Ls for PRM/BS/SRM
|
Fri Mar 12 13:48:53 2021, gautam, Summary, SUS, Coil Rs & Ls for PRM/BS/SRM
|
Thu Mar 25 16:02:15 2021, gautam, Summary, SUS, Repeated measurement of coil Rs & Ls for PRM/BS
|
Tue Mar 16 14:37:36 2021, Yehonathan, Update, BHD, SOS SmCo magnets Inspection  
|
Wed Mar 17 14:40:39 2021, Yehonathan, Update, BHD, SOS SmCo magnets Inspection
|
Thu Mar 25 14:58:16 2021, Yehonathan, Update, BHD, SOS SmCo magnets Inspection
|
Mon Mar 22 16:29:17 2021, gautam, Update, ASC, Some prep for AS WFS commissioning 
|
Sun Mar 21 19:31:29 2021, rana, Summary, Electronics, RTL-SDR for monitoring RF noise / interference
|
Thu Mar 18 21:37:59 2021, rana, Update, LSC, PRMI investigations: what IS the matrix??
|
Fri Mar 19 11:18:25 2021, gautam, Update, LSC, PRMI investigations: what IS the matrix??
|
Fri Mar 19 22:24:54 2021, gautam, Update, LSC, PRMI investigations: what IS the matrix??  
|
Fri Mar 19 15:31:56 2021, Aidan, Update, Computers, Activated MATLAB license on donatella
|
Fri Mar 19 15:26:19 2021, Aidan, Update, Computers, Activated MATLAB license on megatron
|
Thu Mar 18 18:06:36 2021, gautam, Update, Electronics, Modified Sat Amp and Coil Driver
|
Wed Mar 17 15:02:06 2021, gautam, Update, safety, Door to outside from control room was unlocked
|
Thu Mar 18 12:35:29 2021, rana, Update, safety, Door to outside from control room was unlocked
|
Tue Mar 16 16:02:33 2021, Koji, Update, LSC, REFL11 demod retrofitting    
|
Thu Mar 18 07:02:27 2021, Koji, Update, LSC, REFL11 demod retrofitting 
|
Thu Mar 18 01:12:31 2021, gautam, Update, LSC, PRFPMi  
|
Wed Mar 17 15:04:20 2021, gautam, Update, Electronics, Ribbon cable for chassis
|
Wed Mar 17 10:52:48 2021, Jordan, Update, SUS, 3" Ring Adpater for SOS    
|
Wed Mar 17 00:05:26 2021, gautam, Update, LSC, Delay line BIO remote control
|
Mon Mar 15 08:55:45 2021, Paco, Anchal, Summary, training,   
|
Mon Mar 15 20:40:01 2021, rana, Configuration, Computers, installed QTgrace on donatella for dataviewer
|
Mon Mar 15 20:22:01 2021, gautam, Update, ASC, c1rfm model restarted   
|
Fri Mar 12 21:15:19 2021, gautam, Update, LSC, coronaversary PRFPMi 
|
Fri Mar 12 19:44:31 2021, gautam, Update, LSC, Delay line
|
Fri Mar 12 18:10:01 2021, Anchal, Summary, Computer Scripts / Programs, Installed cds-workstation on allegra
|
Fri Mar 12 11:44:53 2021, Paco, Anchal, Update, training, IMC SUS diagonalization in progress
|
Thu Mar 11 14:27:56 2021, gautam, Update, CDS, timesync issue? 
|
Thu Mar 11 18:46:06 2021, gautam, Update, CDS, cds reboot
|
Fri Mar 12 03:28:51 2021, Koji, Update, CDS, cds reboot
|
Fri Mar 12 11:02:38 2021, gautam, Update, CDS, cds reboot
|
Fri Mar 12 03:23:37 2021, Koji, Update, BHD, DO card (DO-32L-PE) brought from WB 
|
Fri Mar 12 03:22:45 2021, Koji, Update, General, Gaussmeter in the electronics drawer
|
Thu Mar 11 20:18:00 2021, gautam, Update, LSC, High bandwidth POY 
|
Thu Mar 11 14:03:02 2021, gautam, Update, LSC, AO path
|
Thu Mar 11 02:10:06 2021, Koji, Summary, BHD, BHD Platform vertical dimentions
|
Wed Mar 10 00:32:03 2021, gautam, Update, LSC, PRFPMi
|
Thu Mar 11 01:45:42 2021, gautam, Update, LSC, PRFPMi
|
Wed Mar 10 19:58:27 2021, gautam, Update, LSC, SR785 hooked up to CM board
|
Wed Mar 10 11:55:22 2021, gautam, Update, SUS, PRM suspension suspect  
|
Wed Mar 10 17:35:47 2021, gautam, Update, SUS, Spooky action at a distance 
|
Thu Feb 18 15:15:12 2021, yehonathan, Update, SUS, OSEM testing for SOSs
|
Mon Feb 22 14:06:49 2021, Yehonathan, Update, SUS, OSEM testing for SOSs
|
Wed Feb 24 10:23:03 2021, Yehonathan, Update, SUS, OSEM testing for SOSs  
|
Wed Mar 3 11:51:07 2021, Yehonathan, Update, SUS, OSEM testing for SOSs
|
Tue Mar 9 14:30:22 2021, Yehonathan, Update, SUS, OSEM testing for SOSs
|
Tue Mar 9 15:19:03 2021, Koji, Update, SUS, OSEM testing for SOSs
|
Tue Mar 9 18:49:28 2021, Yehonathan, Update, SUS, OSEM testing for SOSs
|
Tue Feb 23 20:55:19 2021, Koji, Update, SUS, OSEM testing for SOSs
|
Wed Feb 24 10:09:16 2021, yehonathan, Update, SUS, OSEM testing for SOSs
|
Tue Mar 9 10:57:06 2021, Paco, Anchal, Summary, IMC, XARM lock and POX spectra 
|
Tue Mar 9 14:37:26 2021, gautam, Summary, SUS, PRM suspension
|
Tue Mar 9 15:22:56 2021, Koji, Summary, SUS, PRM suspension
|
Tue Mar 9 12:41:29 2021, Koji, Summary, Electronics, Investigation on the invacuum Dsub cables
|
Sun Mar 7 15:26:10 2021, gautam, Update, LSC, Housekeeping + more PRMI 
|
Mon Mar 8 22:01:26 2021, gautam, Update, LSC, More PRMI 
|
Mon Mar 8 20:11:51 2021, rana, Frogs, Computer Scripts / Programs, activate_matlab out of control on Megatron
|
Mon Mar 8 17:09:29 2021, gautam, Update, SUS, PRM coil actuators heavily imbalanced
|
Mon Mar 8 12:54:54 2021, gautam, Update, Equipment loan, 40m-->Cryo
|
Sat Mar 6 12:34:18 2021, gautam, Update, LSC, Sensing matrix settings messed with
|
Sun Mar 7 19:56:27 2021, Anchal, Update, LSC, Sensing matrix settings messed with
|
Tue Mar 2 19:52:46 2021, gautam, Update, LSC, REFL55 demod board rework
|
Wed Mar 3 22:13:05 2021, gautam, Update, LSC, REFL55 demod board rework
|
Thu Mar 4 23:16:08 2021, Koji, Update, LSC, REFL55 demod board rework    
|
Fri Mar 5 13:53:57 2021, gautam, Update, LSC, REFL55 demod board rework
|
Fri Mar 5 15:31:23 2021, Koji, Update, LSC, REFL55 demod board rework
|
Fri Mar 5 16:24:24 2021, gautam, Update, LSC, REFL55 demod board re-installed in 1Y2 
|
Fri Mar 5 22:25:13 2021, gautam, Update, LSC, PRMI 1f SB locking recovered
|
Thu Mar 4 23:57:35 2021, Koji, Summary, Electronics, Inspection of the new custom dsub cables 6x
|
Thu Mar 4 10:54:12 2021, Paco, Anchal, Summary, LSC, POY11 measurement, tried to lock Green Yend laser 
|
Thu Mar 4 11:59:25 2021, Paco, Anchal, Summary, LSC, Watchdog tripped, Optics damped back
|
Thu Mar 4 15:48:26 2021, Koji, Summary, PEM, Watchdog tripped, Optics damped back
|
Wed Mar 3 23:23:58 2021, gautam, Update, ALS, Arm cavity scan
|
Wed Mar 3 12:00:58 2021, Paco, Anchal, HowTo, IMC, MC_F ASD 
|
Thu Nov 14 23:56:18 2019, rana, Update, LSC, off the bad Violin filters
|
Fri Nov 15 11:58:12 2019, gautam, Update, LSC, off the bad Violin filters 
|
Mon Mar 1 16:27:17 2021, gautam, Update, LSC, PRM violin filter excessive? 
|
Tue Mar 2 13:39:31 2021, rana, Update, LSC, PRM violin filter excessive?
|
Mon Mar 1 11:40:15 2021, Anchal, Paco, Summary, IMC, getting familiar with IMC controls
|
Mon Mar 1 12:36:38 2021, gautam, Summary, IMC, getting familiar with IMC controls
|
Sun Feb 28 16:59:39 2021, rana, gautam, Update, LSC, more PRMI checks here: what it is ain't exactly clear
|
Sun Feb 28 22:53:22 2021, gautam, Update, LSC, more PRMI checks here: what it is ain't exactly clear    
|
Sat Feb 20 16:20:33 2021, gautam, Update, General, Housekeeping + PRMI char   
|
Sun Feb 21 20:51:21 2021, rana, Update, General, Housekeeping + PRMI char
|
Tue Feb 23 00:10:05 2021, gautam, Update, General, Demod char part 1 
|
Wed Feb 24 11:53:24 2021, gautam, Update, General, Demod char part 2 
|
Wed Feb 24 12:11:08 2021, gautam, Update, General, Demod char part 3   
|
Thu Feb 25 16:50:53 2021, gautam, Update, General, PRMI sensing matrix
|
Thu Feb 25 20:37:49 2021, gautam, Update, General, Setting modulation frequency and checking IMC offset 
|
Wed Nov 4 17:14:49 2020, gautam, Update, CDS, c1bhd setup
|
Fri Nov 6 14:27:16 2020, gautam, Update, CDS, c1bhd setup - diskless boot
|
Thu Feb 25 14:30:05 2021, gautam, Update, CDS, new c1bhd setup - diskless boot
|
Wed Feb 24 12:29:18 2021, gautam, Update, General, Input pointing recovered
|
Tue Feb 23 23:12:37 2021, Koji, Summary, SUS, SUS invacuum wiring
|
Mon Feb 22 14:53:47 2021, gautam, Update, CDS, dtt-ezca-tools installed on rossa
|
Fri Feb 19 13:38:26 2021, gautam, Update, LSC, PRFPMI
|
Fri Feb 19 18:22:42 2021, rana, Update, LSC, PRFPMI sensiing matrix woes
|
Fri Feb 19 15:17:51 2021, Jordan, Update, SUS, CoM Range on 3"->2" Adapter Ring for SOS  
|
Fri Feb 19 16:06:01 2021, Koji, Update, SUS, CoM Range on 3"->2" Adapter Ring for SOS
|
Fri Feb 19 16:14:16 2021, gautam, Update, SUS, CoM Range on 3"->2" Adapter Ring for SOS
|
Fri Feb 19 16:55:26 2021, Koji, Update, SUS, CoM Range on 3"->2" Adapter Ring for SOS
|
Tue Feb 16 14:56:44 2021, gautam, Update, SUS, aLIGO Sat Amp installed, powered 
|
Wed Feb 17 16:11:53 2021, gautam, Update, SUS, aLIGO Sat Amp installed, powered
|
Thu Feb 18 15:33:21 2021, gautam, Update, SUS, aLIGO Sat Amp installed, powered and commissioned
|
Thu Feb 18 18:05:04 2021, gautam, Update, SUS, aLIGO Sat Amp characterization 
|
Thu Feb 18 20:20:25 2021, Koji, Update, SUS, aLIGO Sat Amp characterization
|
Thu Feb 18 03:20:09 2021, Koji, Summary, Electronics, Current Rack Map
|
Fri Feb 12 15:03:48 2021, Jordan, Update, SUS, CoM on 3"->2" Adapter Ring for SOS  
|
Wed Feb 17 13:59:43 2021, Koji, Update, SUS, CoM on 3"->2" Adapter Ring for SOS
|
Wed Feb 17 13:59:35 2021, gautam, Update, DetChar, Summary pages
|
Thu Feb 11 18:21:39 2021, gautam, Update, SUS, MC suspension glitches
|
Wed Jan 20 18:07:09 2021, Anchal, Summary, BHD, HAM-A Coil Driver measurements before modifications 7x
|
Mon Jan 25 18:18:04 2021, Anchal, Summary, BHD, Satellite Amplifier Transfer Functions and noise 
|
Wed Feb 3 16:27:19 2021, Anchal, Summary, BHD, Satellite Amplifier Transfer Functions and noise After modifications    
|
Wed Feb 10 11:45:59 2021, Anchal, Summary, BHD, Satellite Amplifier Very Low frequency noise After modifications 6x
|
Wed Feb 10 15:07:50 2021, Anchal, Summary, BHD, Satellite Amplifier Output Offset measurements
|
Wed Feb 10 15:25:45 2021, gautam, Summary, BHD, Satellite Amplifier Output Offset measurements
|
Wed Feb 10 17:18:03 2021, Koji, Summary, BHD, Satellite Amplifier Output Offset measurements
|
Thu Feb 11 11:10:05 2021, Anchal, Summary, BHD, Satellite Amplifier Very Low frequency noise After modifications   
|
Thu Feb 11 16:58:52 2021, rana, Summary, BHD, Satellite Amplifier Very Low frequency noise After modifications
|
Thu Jan 28 12:53:14 2021, Anchal, Summary, BHD, HAM-A Coil Driver measurements before modifications    
|
Thu Jan 28 18:04:55 2021, Anchal, Summary, BHD, HAM-A Coil Driver measurements After modifications 
|
Thu Jan 28 21:44:45 2021, gautam, Summary, BHD, HAM-A Coil Driver measurements After modifications
|
Fri Jan 29 15:39:30 2021, Anchal, Summary, BHD, HAM-A Coil Driver measurements After modifications TF and Noise S2100027    
|
Tue Feb 2 11:57:46 2021, Anchal, Summary, BHD, HAM-A Coil Driver measurements After modifications TF and Noise S2100028    
|
Wed Feb 10 14:14:58 2021, gautam, Update, Electronics, Custom cables received
|
Tue Feb 2 23:29:35 2021, Koji, Update, CDS, CDS crash and CDS/IFO recovery
|
Wed Feb 3 15:24:52 2021, gautam, Update, CDS, CDS crash and CDS/IFO recovery
|
Wed Feb 3 18:53:31 2021, Koji, Update, CDS, CDS crash and CDS/IFO recovery
|
Wed Feb 3 21:28:02 2021, gautam, Update, CDS, CDS crash and CDS/IFO recovery
|
Tue Jan 12 08:21:47 2021, anchal, HowTo, CDS, Acromag wiring investigation  
|
Tue Jan 12 11:42:38 2021, gautam, HowTo, CDS, Acromag wiring investigation
|
Wed Jan 13 16:09:29 2021, Anchal, HowTo, CDS, Acromag wiring investigation
|
Tue Jan 26 12:59:51 2021, Anchal, HowTo, CDS, Acromag wiring investigation
|
Tue Jan 26 15:37:25 2021, Anchal, HowTo, CDS, Acromag wiring investigation  
|
Fri Jan 29 17:57:17 2021, Anchal, HowTo, CDS, Acromag wiring investigation  
|
Thu Jan 28 22:34:21 2021, gautam, Update, SUS, De-whitening   
|
Tue Jan 26 10:58:30 2021, gautam, Update, SUS, MC2 tickler stuck on
|
Wed Jan 20 19:12:16 2021, gautam, Update, CDS, SLwebview fixed
|
Fri Dec 18 22:59:12 2020, Jon, Configuration, CDS, Updated CDS upgrade plan 
|
Mon Dec 21 09:28:50 2020, Jamie, Configuration, CDS, Updated CDS upgrade plan
|
Wed Dec 23 23:06:45 2020, gautam, Configuration, CDS, Updated CDS upgrade plan
|
Tue Jan 19 14:05:25 2021, Jon, Configuration, CDS, Updated CDS upgrade plan 
|
Tue Jan 19 15:43:24 2021, gautam, Configuration, CDS, Updated CDS upgrade plan
|
Thu Jan 14 11:46:20 2021, gautam, Update, CDS, Expansion chassis from LHO
|
Thu Jan 14 12:19:43 2021, Jon, Update, CDS, Expansion chassis from LHO
|
Fri Jan 15 15:06:42 2021, Jon, Update, CDS, Expansion chassis from LHO
|
Fri Jan 15 16:54:57 2021, gautam, Update, CDS, Expansion chassis from LHO
|
Tue Jan 19 13:19:24 2021, Jon, Update, CDS, Expansion chassis from LHO
|
Wed Nov 18 22:49:06 2020, gautam, Update, ASC, Some thoughts about AS WFS electronics
|
Sun Nov 22 21:09:37 2020, gautam, Update, ASC, Planned mods for WFS head  
|
Wed Nov 25 18:18:41 2020, gautam, Update, ASC, Planned mods for WFS head 
|
Sat Nov 28 21:44:53 2020, rana, Update, ASC, Planned mods for WFS head
|
Thu Dec 10 22:46:57 2020, gautam, Update, ASC, WFS head assembled 
|
Thu Dec 17 15:23:56 2020, gautam, Update, ASC, WFS head characterization    
|
Wed Nov 25 18:30:23 2020, gautam, Update, ASC, Some thoughts about AS WFS electronics
|
Wed Dec 2 23:07:19 2020, gautam, Update, ASC, Electrical LO signal for AS WFS
|
Thu Dec 3 11:02:35 2020, rana, Update, Electronics, Electrical LO signal for AS WFS
|
Thu Dec 3 13:55:52 2020, Koji, Update, ASC, Electrical LO signal for AS WFS
|
Thu Dec 3 20:38:46 2020, gautam, Update, ASC, Electrical LO signal for AS WFS  
|
Thu Dec 3 21:14:38 2020, Koji, Update, ASC, Electrical LO signal for AS WFS
|
Thu Dec 3 21:44:49 2020, gautam, Update, ASC, Electrical LO signal for AS WFS
|
Fri Dec 4 03:02:40 2020, Koji, Update, ASC, Electrical LO signal for AS WFS
|
Fri Dec 4 22:41:56 2020, gautam, Update, ASC, Freq Gen Box revamp
|
Sat Dec 5 20:44:35 2020, gautam, Update, ASC, Freq Gen Box re-installed 6x
|
Mon Dec 7 12:38:51 2020, gautam, Update, IOO, IMC loop char  
|
Mon Dec 7 22:54:30 2020, gautam, Update, LSC, Modulation depth measurement
|
Sat Jan 16 18:59:44 2021, gautam, Update, LSC, Modulation depth measurement   
|
Fri Jan 15 17:04:45 2021, gautam, Update, LSC, Messed up LSC sensing 
|
Thu Jan 14 12:32:28 2021, gautam, Update, CDS, Rogue master may be doing something good?
|
Thu Aug 6 00:34:38 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
|
Fri Aug 7 11:23:47 2020, rana, Update, BHD, Monte Carlo Simulations
|
Mon Aug 10 07:13:00 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
|
Tue Aug 25 05:51:29 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
|
Mon Sep 14 07:50:01 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 10x
|
Fri Oct 16 09:16:37 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
|
Thu Oct 22 11:48:08 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
|
Thu Dec 10 14:48:00 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 
|
Fri Dec 11 09:28:52 2020, rana, Update, BHD, Monte Carlo loop coupling Simulations
|
Mon Dec 14 11:09:28 2020, Yehonathan, Update, BHD, Monte Carlo loop coupling Simulations 
|
Mon Jan 11 16:11:51 2021, Yehonathan, Update, BHD, Monte Carlo loop coupling Simulations
|
Mon Jan 11 19:10:10 2021, rana, Update, BHD, Monte Carlo loop coupling Simulations
|
Wed Jan 6 22:47:41 2021, gautam, Update, ALS, Noisy ALS 
|
Thu Jan 7 19:16:11 2021, gautam, Update, ALS, Noisy ALS 
|
Thu Jan 7 20:07:27 2021, Koji, Update, ALS, Noisy ALS
|
Thu Jan 7 21:16:22 2021, gautam, Update, ALS, Noisy ALS
|
Thu Jan 7 23:25:19 2021, Koji, Update, ALS, Noisy ALS
|
Fri Jan 8 20:01:11 2021, gautam, Update, ALS, Noisy ALS
|
Wed Jan 6 19:00:04 2021, gautam, Update, LSC, Phase loss in POX/POY loops 
|
Wed Jan 6 16:18:38 2021, gautam, Update, Optical Levers, BS Oplev glitchy   
|
Wed Jan 6 15:28:04 2021, gautam, Update, VAC, Vac rack UPS batteries replaced
|
Wed Dec 23 10:13:08 2020, gautam, Update, CDS, Near term upgrades
|
Mon Dec 21 18:18:03 2020, gautam, Update, CDS, Many model changes
|
Tue Dec 22 22:11:37 2020, gautam, Update, CDS, AA filt repaired and reinstalled
|
Sat Dec 19 20:24:25 2020, gautam, Update, Electronics, WFS hardware install
|
Thu Dec 10 17:12:43 2020, Jon, Update, , New SMA cables on order
|
Sat Dec 19 00:25:20 2020, Jon, Update, , New SMA cables on order
|
Sat Dec 19 02:42:56 2020, Koji, Update, , New SMA cables on order
|
Fri Dec 18 10:52:17 2020, gautam, Update, CDS, RFM errors
|
Tue Dec 15 12:38:41 2020, gautam, Update, Electronics, DC power strip
|
Thu Dec 10 22:45:42 2020, gautam, Update, SUS, More spare OSEMs
|
Thu Dec 10 16:24:13 2020, gautam, Update, Equipment loan, Noliac PZT --> Paco
|
Wed Dec 9 20:14:49 2020, gautam, Update, VAC, UPS failure   
|
Thu Dec 10 13:05:52 2020, Jon, Update, VAC, UPS failure 
|
Thu Dec 10 14:29:26 2020, gautam, Update, VAC, UPS failure
|
Thu Dec 10 11:07:24 2020, Chub, Update, VAC, UPS fault
|
Thu Dec 10 11:17:50 2020, Chub, Update, VAC, UPS fault
|
Wed Dec 9 15:37:48 2020, gautam, Update, CDS, RFM switch IP addr reset 
|
Wed Dec 9 12:02:04 2020, gautam, Update, LSC, POX locking still unsatisfactory 
|
Wed Dec 9 11:54:11 2020, gautam, Update, Optical Levers, ITMX HeNe replaced  
|
Tue Dec 8 15:07:13 2020, gautam, Update, Computer Scripts / Programs, ndscope updated
|
Mon Dec 7 14:32:02 2020, gautam, Update, LSC, New demod phases for POX/POY locking 
|
Fri Dec 4 19:23:40 2020, Koji, Update, Electronics, AA/AI board testing ongoing
|
Tue Nov 10 12:41:23 2020, gautam, Update, IOO, 1W —> IMC
|
Tue Nov 10 14:30:06 2020, gautam, Update, IOO, WFS2 broken 
|
Fri Dec 4 15:58:22 2020, Koji, Update, IOO, WFS2 broken
|
Wed Sep 16 12:03:07 2020, Jon, Update, VAC, Replacing pressure gauges
|
Wed Dec 2 12:27:49 2020, Jon, Update, VAC, Replacing pressure gauges
|
Thu Dec 3 14:53:58 2020, Jon, Update, VAC, Replacing pressure gauges
|
Thu Dec 3 10:46:39 2020, gautam, Update, Electronics, DC power strip requirements
|
Thu Dec 3 10:33:00 2020, gautam, Update, VAC, TrippLite UPS delivered
|
Wed Dec 2 18:35:31 2020, gautam, Update, DetChar, Summary page revival
|
Wed Dec 2 17:54:03 2020, gautam, Update, CDS, FE reboot
|
Wed Dec 2 12:35:31 2020, Paco, Summary, Computer Scripts / Programs, TC200 python driver
|
Wed Dec 2 15:27:06 2020, gautam, Summary, Computer Scripts / Programs, TC200 python driver
|
Tue Nov 24 16:51:29 2020, gautam, Update, PonderSqueeze, Ponderomotive squeezing in aLIGO  
|
Mon Nov 23 23:27:43 2020, Koji, Summary, ASC, Q3000 characterization
|
Wed Nov 18 17:51:50 2020, gautam, Update, VAC, Agilent pressure gauge controller delivered
|
Mon Nov 23 16:33:10 2020, gautam, Update, VAC, More vacuum deliveries
|
Mon Nov 23 12:25:14 2020, gautam, Update, BHD, BHD MMT Optics delivered
|
Mon Nov 23 14:52:10 2020, Koji, Update, BHD, BHD MMT Optics delivered
|
Tue Nov 17 13:24:40 2020, Chub, Update, General, big UPS on the way
|
Thu Nov 12 14:31:27 2020, gautam, Update, Electronics, SR560s in need of repair/battery replacement
|
Tue Nov 17 00:26:32 2020, rana, Update, Electronics, SR560s in need of repair/battery replacement
|
Mon Nov 16 16:00:19 2020, gautam, Update, Equipment loan, LB1005-->Cryo lab
|
Wed Nov 4 00:10:43 2020, gautam, Update, General, Vent activities today    
|
Thu Nov 5 22:27:34 2020, gautam, Update, General, Vent activities today
|
Fri Nov 6 11:36:37 2020, gautam, Update, General, ETMY suspension eigenmodes 
|
Tue Nov 10 15:13:41 2020, rana, Update, General, ETMY suspension eigenmodes
|
Thu Nov 12 14:26:35 2020, gautam, Update, General, ETMY suspension eigenmodes
|
Sun Nov 8 20:22:35 2020, gautam, Update, General, Vent activities today
|
Sun Nov 8 23:24:29 2020, Koji, Update, General, Vent activities today
|
Mon Nov 9 17:40:17 2020, gautam, Update, General, Pumpdown 
|
Tue Nov 10 11:31:13 2020, Koji, Update, General, Pumpdown
|
Tue Nov 10 17:46:06 2020, gautam, Update, General, IFO recovery   
|
Tue Nov 10 11:59:37 2020, gautam, Update, VAC, Stuck RV2  
|
Fri Nov 6 14:08:44 2020, gautam, Update, PSL, PMC re-locked
|
Tue Nov 3 09:06:50 2020, gautam, Update, General, Lab alarm tripped
|
Wed Oct 28 20:42:53 2020, Koji, Update, General, Vent Prep 10x
|
Thu Oct 29 12:43:35 2020, gautam, Update, General, Vent Prep   
|
Thu Oct 29 19:30:56 2020, gautam, Update, General, Vent complete   
|
Mon Nov 2 12:44:25 2020, gautam, Update, General, ETMY and OMC chamber heavy doors off
|
Mon Nov 2 16:46:06 2020, gautam, Update, General, Plan for OMC chamber 
|
Mon Nov 2 17:13:19 2020, Koji, Update, General, Plan for OMC chamber
|
Mon Nov 2 17:32:05 2020, gautam, Update, General, Plan for OMC chamber
|
Thu Oct 29 09:50:12 2020, anchal, Summary, Calibration, Preliminary calibration measurement taken
|
Tue Oct 27 23:47:53 2020, gautam, Update, General, ISS checkout
|
Wed Oct 28 14:01:03 2020, not gautam, Update, General, ISS checkout
|
Wed Oct 28 14:07:47 2020, gautam, Update, General, ISS checkout
|
Sat Oct 3 16:51:27 2020, gautam, Update, CDS, RFM errors 
|
Wed Oct 28 09:35:00 2020, Koji, Update, CDS, RFM errors
|
Fri Oct 23 16:41:06 2020, Koji, Update, IOO, Excess laser freq noise investigation
|
Mon Oct 26 13:35:58 2020, Koji, Update, IOO, Excess laser freq noise investigation 6x
|
Mon Oct 26 17:26:26 2020, gautam, Update, IOO, Excess laser freq noise investigation
|
Fri Oct 23 19:01:57 2020, Koji, Summary, PEM, PSL Particle Counter kit removed from the table 
|
Tue Oct 20 20:12:18 2020, Koji, Summary, General, DJI OSMO Pocket Camera Kit
|
Mon Oct 19 15:40:02 2020, Koji, Update, PEM, Alaska EQ M7.5
|
Mon Oct 19 15:38:42 2020, Koji, Update, Electronics, Loan: A file binder "40m wiring diagram"
|
Thu Oct 15 13:48:58 2020, anchal, Summary, General, Lab Entry Notification
|
Fri Oct 16 19:44:41 2020, anchal, Summary, General, Lab Entry Notification
|
Tue Oct 13 11:13:54 2020, gautam, Update, BHD, Investigation into RF44 sensing 
|
Thu Oct 15 10:42:39 2020, gautam, Update, BHD, More investigation into RF44 sensing  
|
Wed Oct 14 18:16:27 2020, gautam, Update, General, PSL HEPA-->50%
|
Sat Sep 19 23:59:22 2020, anchal, Summary, ALS, ALS noise budget update    
|
Sun Sep 20 23:12:13 2020, rana, Summary, ALS, ALS noise budget update
|
Tue Sep 22 00:14:43 2020, anchal, Summary, ALS, ALS noise budget update 
|
Tue Sep 22 12:14:42 2020, rana, Summary, ALS, ALS noise budget update
|
Wed Sep 23 11:13:49 2020, anchal, Summary, ALS, ALS noise budget update 
|
Wed Oct 7 16:56:23 2020, anchal, Summary, ALS, ALS noise budget update - Updated AUX PDH Loop values 
|
Thu Oct 8 11:59:52 2020, rana, Summary, ALS, ALS noise budget update - Updated AUX PDH Loop values
|
Fri Oct 9 18:32:14 2020, anchal, Summary, ALS, ALS noise budget update - Updated AUX PDH Loop values
|
Wed Oct 14 17:03:55 2020, anchal, Summary, ALS, ALS noise budget update - Added whitening filter for ADC
|
Wed Oct 14 13:28:04 2020, Koji, Update, COC, ITM/ETM spares in Downs
|
Tue Oct 13 21:22:29 2020, gautam, Update, General, Space cleared in 1Y1 for new FEs
|
Thu Oct 8 08:37:15 2020, gautam, Update, Computer Scripts / Programs, Finesse GUI
|
Thu Oct 8 18:40:42 2020, Koji, Update, Computer Scripts / Programs, Finesse GUI
|
Thu Oct 8 15:08:25 2020, gautam, Update, General, Some boxes moved from 40m entry hallway
|
Wed Oct 7 13:06:27 2020, Koji, Update, General, Presence in the lab
|
Tue Oct 6 14:35:16 2020, Jordan, Update, VAC, Spare forepumps
|
Tue Oct 6 07:37:20 2020, yehonathan, Update, Wiki, New TIS measurements of 40m Optics
|
Mon Oct 5 14:01:41 2020, gautam, Update, Electronics, aLIGO demod boards stuffed and delivered
|
Mon Oct 5 00:37:19 2020, gautam, Update, BHD, Single bounce interferometer locked   
|
Mon Oct 5 00:53:16 2020, Koji, Update, BHD, Single bounce interferometer locked
|
Sun Oct 4 15:32:21 2020, gautam, Update, SUS, Suspension health check 
|
Fri Oct 2 12:52:22 2020, gautam, Update, General, Spectroscopic grade Isopropanol delivered
|
Fri Oct 2 10:29:49 2020, gautam, Update, Optical Levers, ETMY, BS and ITMX HeNes degrading
|
Thu Oct 1 17:44:48 2020, gautam, Update, General, Some inventory notes
|
Tue Sep 22 23:16:54 2020, Koji, Update, General, HEPA Inspection 11x
|
Tue Sep 22 23:17:51 2020, Koji, Update, General, HEPA Inspection 6x
|
Wed Sep 30 17:12:24 2020, gautam, Update, General, HEPA blower startup capacitor replacement
|
Wed Sep 30 19:45:56 2020, rana, Update, General, HEPA blower startup capacitor replacement
|
Tue Sep 29 17:07:25 2020, gautam, Update, General, Lab visit for inventory location
|
Wed Sep 23 15:06:54 2020, Jordan, Update, VAC, TP2 Forepump Re-install 
|
Wed Sep 23 08:57:18 2020, gautam, Update, VAC, TP2 running HOT
|
Wed Sep 23 10:06:52 2020, Koji, Update, VAC, TP2 running HOT
|
Fri Sep 18 10:47:48 2020, gautam, Update, BHD, Sensing scheme for homodyne phase 
|
Tue Sep 22 22:38:11 2020, gautam, Update, BHD, Sensing scheme for homodyne phase - some analytic calcs
|
Tue Sep 22 16:29:30 2020, Koji, Update, General, Control Room AC setting for continuous running
|
Mon Sep 21 16:40:52 2020, gautam, Update, PSL, HEPAs are no longer running
|
Mon Sep 21 15:57:08 2020, Jordan, Update, VAC, TP3 Forepump Replacement and Vac reset  
|
Sat Sep 19 01:49:52 2020, Koji, Update, General, M4.5 EQ in LA
|
Sat Sep 19 11:27:04 2020, rana, Update, General, M4.5 EQ in LA
|
Sat Sep 19 18:08:34 2020, rana, Update, General, M4.5 EQ in LA
|
Sat Sep 19 19:14:59 2020, Koji, Update, General, ITMX released / ETMY UR magnet knocked off
|
Sun Sep 20 11:41:54 2020, gautam, Update, General, IMC re-locked
|
Mon Sep 21 12:40:58 2020, gautam, Update, General, Workable IFO recovery 
|
Sat Sep 19 18:07:35 2020, Koji, Update, VAC, TP3 RP failure 
|
Sat Sep 19 19:37:16 2020, not Koji, Update, VAC, TP3 RP failure
|
Sat Sep 19 18:46:48 2020, Koji, Update, General, Hand soap
|
Wed Sep 16 17:44:27 2020, gautam, Update, CDS, All vertex FE models restarted
|
Tue Sep 15 17:19:09 2020, gautam, Update, IOO, MC F spectrum
|
Tue Sep 15 19:17:30 2020, rana, Update, IOO, MC F spectrum
|
Wed Sep 16 09:43:41 2020, gautam, Update, IOO, MC F spectrum
|
Mon Sep 7 23:49:14 2020, gautam, Update, BHD, A first look at RF44 scheme
|
Tue Sep 8 01:31:43 2020, Koji, Update, BHD, A first look at RF44 scheme
|
Wed Sep 9 00:05:18 2020, gautam, Update, BHD, More notes on the RF44 scheme   
|
Tue Sep 15 22:11:52 2020, gautam, Update, BHD, More notes on the RF44 scheme
|
Fri Jun 26 16:53:38 2020, gautam, Update, Electronics, RFPD characterization  
|
Mon Jun 29 15:56:02 2020, gautam, Update, Electronics, RFPD characterization
|
Sun Jul 5 18:25:42 2020, rana, Update, Electronics, WFS characterization
|
Sun Jul 12 22:40:35 2020, gautam, Update, Electronics, WFS characterization - old SURF report
|
Sat Aug 29 20:07:48 2020, rana, Update, Electronics, WFS characterization
|
Sat Aug 29 22:10:09 2020, gautam, Update, Electronics, WFS characterization
|
Tue Sep 15 17:04:43 2020, gautam, Update, Electronics, DC adaptors delivered
|
Wed Aug 12 18:08:54 2020, gautam, Update, Electronics, Number of the beast
|
Wed Aug 12 20:15:42 2020, Koji, Update, Electronics, Number of the beast
|
Tue Sep 15 12:20:36 2020, gautam, Update, Electronics, SR785 repaired
|
Tue Sep 15 10:57:30 2020, gautam, Update, PSL, PMC re-locked, RGA re-enabled
|
Thu Sep 10 15:56:08 2020, Koji, Update, General, HEPA & Particle Level Status
|
Thu Sep 10 15:43:22 2020, Jon, Update, BHD, Input noise spectra for A+ BHD modeling
|
Wed Sep 9 20:52:45 2020, rana, Summary, IOO, wandering line in IMC
|
Tue Aug 6 14:55:23 2019, gautam, Update, CDS, Making Matlab R2015b the default
|
Mon Sep 30 17:04:30 2019, gautam, Update, CDS, Some path changes
|
Tue Sep 8 11:49:04 2020, gautam, Update, CDS, Some path changes
|
Sun Sep 6 13:15:44 2020, Jon, Update, DAQ, UPS for framebuilder
|
Sat Sep 5 14:28:03 2020, Koji, Update, General, LO beam: Fiber coupling work
|
Fri Sep 4 15:26:55 2020, Jon, Update, VAC, Vac system UPS installation
|
Fri Sep 4 21:12:51 2020, Jon, Update, VAC, Vac system UPS installation
|
Sat Sep 5 12:01:10 2020, Jon, Update, VAC, Vac system UPS installation 
|
Fri Aug 28 23:33:38 2020, gautam, Update, BHD, Some more hardware changes
|
Sat Aug 29 22:46:29 2020, gautam, Update, BHD, New homodyne-phase control electronics 
|
Wed Sep 2 00:49:47 2020, gautam, Update, BHD, Some notes about homodyne phase   
|
Thu Sep 3 15:55:04 2020, gautam, Update, BHD, Phase drift between LO and IFO after fiber replacement 
|
Thu Sep 3 00:00:57 2020, gautam, Update, BHD, New patch cable installed
|
Tue Sep 1 01:49:49 2020, Koji, Update, Electronics, Teledyne AP1053 etc were transported  
|
Sun Aug 30 11:29:33 2020, rana, Update, General, power blink?
|
Sat Aug 29 18:52:42 2020, rana, Update, IOO, IMC gain change
|
Fri Aug 28 11:41:23 2020, gautam, Bureaucracy, safety, Crane inspection 2020
|
Wed Aug 26 22:49:47 2020, gautam, Update, Electronics, Checkout of Trek Model 603
|
Wed Aug 26 15:48:31 2020, gautam, Update, VAC, Control screen left open on vacuum workstation
|
Mon Aug 10 16:52:04 2020, gautam, Update, BHD, Workable setup prepared
|
Tue Aug 11 23:20:29 2020, gautam, Update, BHD, Some first tests with air BHD setup 
|
Fri Aug 21 15:27:00 2020, gautam, Update, BHD, Better BHD mode-matching  
|
Wed Aug 26 00:52:55 2020, gautam, Update, BHD, BHD activities
|
Mon Aug 24 08:13:56 2020, Jon, Update, VAC, UPS installation
|
Mon Aug 24 11:25:07 2020, Jon, Update, VAC, UPS installation
|
Mon Aug 17 23:36:10 2020, gautam, Update, ALS, Whitening and ALS noise
|
Tue Aug 18 13:55:23 2020, rana, Update, ALS, Whitening and ALS noise
|
Mon Aug 17 23:41:50 2020, gautam, Update, BHD, Whitening and air BHD dark noise
|
Mon Aug 17 21:24:43 2020, gautam, Update, General, Fire extinguisher inspection
|
Mon Aug 17 15:18:26 2020, gautam, Update, Equipment loan, Beam Profiler + peripherals --> 40m
|
Fri Aug 14 10:10:56 2020, Jon, Configuration, VAC, Vacuum repairs today
|
Sat Aug 15 02:02:13 2020, Jon, Configuration, VAC, Vacuum repairs today
|
Sat Aug 15 15:12:22 2020, Jon, Configuration, VAC, Overhaul of small turbo pump interlocks   
|
Wed Aug 12 17:36:42 2020, gautam, Update, CDS, Timing distribution slot availability
|
Wed Aug 12 20:14:06 2020, Koji, Update, CDS, Timing distribution slot availability
|
Thu Aug 13 11:30:19 2020, gautam, Update, CDS, Timing distribution slot availability
|
Thu Aug 13 13:35:13 2020, Koji, Update, CDS, Timing distribution slot availability
|
Fri Aug 14 10:03:37 2020, Jon, Update, CDS, Timing distribution slot availability
|
Fri Aug 14 00:01:55 2020, gautam, Update, CDS, BHD / OMC model channels now added to autoburt
|
Thu Aug 13 18:10:22 2020, gautam, Update, General, Power outage
|
Wed Aug 12 17:42:58 2020, gautam, Update, Electronics, Photodiode inventory 
|
Wed Aug 12 20:16:52 2020, Koji, Update, Electronics, Photodiode inventory
|
Sat Aug 8 07:36:52 2020, Sanika Khadkikar, Configuration, Calibration-Repair, BS Seismometer - Multi-channel calibration   
|
Thu Aug 6 22:57:20 2020, gautam, Update, safety, New live HV Supplies
|
Thu Jul 30 16:16:43 2020, gautam, Update, SUS, Suspension recovery
|
Thu Jul 9 17:12:52 2020, gautam, Update, BHD, In-air BHD 
|
Tue Jul 14 15:29:25 2020, gautam, Update, BHD, In-air BHD - DCPD amplifier noise
|
Wed Jul 15 19:11:40 2020, gautam, Update, BHD, In-air BHD - alignment into OMC
|
Thu Jul 16 01:12:22 2020, gautam, Update, BHD, In-air BHD - preparing the LO path   
|
Sun Jul 19 15:40:15 2020, gautam, Update, BHD, In-air BHD - CDS and wiring summary
|
Wed Jul 29 11:57:59 2020, rana, Update, BHD, In-air BHD - CDS and wiring summary
|
Mon Jul 20 17:55:15 2020, gautam, Update, BHD, In-air BHD - preparing the LO path
|
Tue Jul 21 00:30:24 2020, gautam, Update, BHD, In-air BHD - LO RIN
|
Tue Jul 28 12:22:40 2020, Jon, Update, VAC, Vac interlock test today 1:30 pm
|
Tue Jul 28 14:11:14 2020, Jon, Update, VAC, Vac interlock test today 1:30 pm
|
Tue Jul 28 13:55:11 2020, Hang, Update, BHD, Exploring bilinear SRCL->DARM coupling  
|
Thu Jul 23 15:58:24 2020, Jon, Summary, VAC, Vacuum controls refurbishment plan
|
Mon Jul 27 15:48:36 2020, Jon, Summary, VAC, Vacuum parts ordered
|
Fri Jul 24 15:40:59 2020, Jordan, Update, VAC, Installation of two new UPS units
|
Tue Jul 21 16:41:46 2020, gautam, Update, BHD, PMC assembly space
|
Mon Jul 20 19:21:16 2020, anchal, Summary, ALS, Few proposals for Voyager ALS
|
Tue Jul 14 16:52:47 2020, gautam, Update, Electronics, Coil drivers for the test masses
|
Wed Jul 15 21:08:43 2020, gautam, Update, Electronics, ETM coil outputs DQed 
|
Mon Jul 20 17:23:46 2020, gautam, Update, Electronics, Coil drivers for the test masses  
|
Fri Jul 17 09:03:58 2020, Jordan, Update, General, Presence at 40m
|
Fri Jul 17 00:18:13 2020, gautam, Update, General, Locking updat
|
Thu Jul 16 14:41:22 2020, gautam, Update, General, Fire extinguisher inspection
|
Wed Jul 15 19:23:44 2020, gautam, Update, General, Emergency light on in control room
|
Wed Jul 15 19:51:51 2020, Koji, Update, General, Emergency light on in control room
|
Wed Jul 15 20:58:40 2020, gautam, Update, General, Emergency light on in control room
|
Wed Jul 15 17:46:05 2020, anchal, Summary, ALS, Noise budget for ALS
|
Tue Jul 14 00:06:09 2020, gautam, Update, LSC, Locking with POX for CARM
|
Tue Jul 14 01:55:03 2020, Koji, Update, LSC, Locking with POX for CARM
|
Tue Jul 14 17:28:29 2020, gautam, Update, LSC, Locking with POX for CARM 
|
Tue Jul 14 09:04:53 2020, Jordan, Update, General, Presence at 40m
|
Fri Sep 6 16:38:24 2019, aaron, Update, ALARM, Alarm noise from smart-ups machine under workstation?
|
Fri Sep 6 18:08:29 2019, rana, Update, Computers, Alarm noise from smart-ups machine under workstation?
|
Thu Sep 12 09:49:07 2019, gautam, Update, Computers, control rm wkstns shutdown
|
Mon Sep 30 11:42:36 2019, aaron, Update, Computers, control rm wkstns shutdown
|
Wed Oct 2 20:45:18 2019, rana, Update, Computers, rossa revival
|
Thu Oct 3 21:50:22 2019, rana, Update, Computers, rossa revival
|
Mon Oct 28 18:55:06 2019, rana, Update, Computers, rossa revival
|
Wed Jan 22 16:38:01 2020, rana, Update, Computers, rossa revival
|
Wed Jul 1 18:16:09 2020, gautam, Update, Computers, rossa re-re-revival
|
Sun Jul 5 16:14:41 2020, rana, Update, Computers, rossa re-re-revival
|
Sun Jul 5 18:39:57 2020, rana, Update, Computers, rossa: printer
|
Mon Jul 6 00:37:28 2020, gautam, Update, Computers, rossa: lib symlink
|
Mon Jul 6 12:43:02 2020, rana, Update, Computers, rossa: lib symlink
|
Mon Jul 6 12:51:41 2020, gautam, Update, Computers, rossa: resolvconf installed
|
Wed Jul 8 22:50:33 2020, gautam, Update, Computers, rossa: more symlinks
|
Thu Jul 9 16:16:20 2020, gautam, Update, Computers, rossa: graphics driver issues?
|
Sat Jul 11 00:10:22 2020, gautam, Update, Computers, rossa: more developmental work
|
Mon Jul 13 11:33:18 2020, rana, Update, Computers, rossa: more developmental work
|
Mon Jul 13 12:37:05 2020, gautam, Update, Computers, rossa: more developmental work
|
Fri Jul 10 01:25:28 2020, gautam, Update, LSC, Locking notes
|
Fri Jul 10 15:26:28 2020, gautam, Update, LSC, MC2 coils need DC balancing? 
|
Sat Jul 11 18:24:30 2020, Koji, Update, LSC, MC2 coils need DC balancing?
|
Sun Jul 12 02:42:01 2020, gautam, Update, LSC, Locking (on rossa)
|
Mon Jul 13 11:36:08 2020, rana, Update, LSC, MC2 coils need DC balancing?
|
Fri Jul 10 10:37:30 2020, Jordan, Update, General, Presence at 40m
|
Wed Jul 1 18:03:04 2020, Jon, Configuration, VAC, UPS replacements
|
Thu Jul 9 18:00:35 2020, Jon, Configuration, VAC, UPS replacements
|
Thu Jul 9 16:02:33 2020, Jon, HowTo, CDS, Procedure for setting up BHD front-ends
|
Thu Jul 9 09:22:44 2020, Jordan, Update, General, Presence at 40m
|
Wed Jul 8 08:51:35 2020, Jordan, Update, General, Presence at 40m
|
Tue May 26 02:15:36 2020, gautam, Update, LSC, Lock acquisition portal entry
|
Tue May 26 02:31:00 2020, gautam, Update, LSC, Lock acquisition sequence
|
Wed May 27 20:14:51 2020, Koji, Update, LSC, Lock acquisition sequence
|
Tue May 26 02:37:19 2020, gautam, Update, LSC, DARM loop measurement and fitting 
|
Tue May 26 03:01:35 2020, gautam, Update, LSC, CARM loop
|
Wed Jun 3 01:46:14 2020, gautam, Update, LSC, CARM loop    
|
Tue May 26 03:06:59 2020, gautam, Update, LSC, PRFPMI sensing matrix 
|
Tue May 26 03:26:58 2020, gautam, Update, LSC, Preliminary noise budget
|
Tue May 26 14:32:44 2020, gautam, Update, LSC, Arm transmission RIN
|
Wed May 27 19:36:33 2020, Koji, Update, LSC, Arm transmission RIN
|
Thu May 28 18:36:45 2020, gautam, Update, LSC, Arm transmission RIN  
|
Fri May 29 00:34:57 2020, rana, Update, LSC, Arm transmission RIN
|
Wed Jun 3 02:14:32 2020, gautam, Update, ASC, PRC ASC improves arm transmission RIN    
|
Fri Jun 19 16:30:09 2020, gautam, Update, ASC, Some thoughts about ASC 
|
Tue Jul 7 14:06:10 2020, gautam, Update, ASC, Some more thoughts about ASC
|
Tue May 26 16:00:06 2020, gautam, Update, LSC, Power buildup diagnostics 
|
Wed May 27 17:41:57 2020, Koji, Update, LSC, Power buildup diagnostics
|
Wed Jun 3 02:08:00 2020, gautam, Update, LSC, Power buildup diagnostics 
|
Wed Jun 3 01:34:53 2020, gautam, Update, LSC, Lock acquisition update portal
|
Wed Jun 3 03:29:26 2020, Koji, Update, LSC, Lock acquisition update portal
|
Wed Jun 3 11:40:56 2020, gautam, Update, LSC, Lock acquisition update portal
|
Wed Jun 3 18:49:47 2020, gautam, Update, LSC, PRG and CARM signal sign   
|
Fri Jun 19 17:06:50 2020, gautam, Update, LSC, What should the short-term commissioning goals be?
|
Wed Jun 24 17:20:16 2020, gautam, Update, LSC, What should the short-term commissioning goals be?
|
Tue Jun 30 10:59:16 2020, gautam, Update, LSC, Three sensing matrices  
|
Mon Jul 6 17:41:19 2020, gautam, Update, LSC, An LSC puzzler
|
Mon Jul 6 15:10:40 2020, Jon, Summary, BHD, 40m --> A+ BHD design analysis
|
Mon Jul 6 08:48:15 2020, Jordan, Update, General, Presence at 40m
|
Thu Jul 2 16:51:23 2020, Jordan, Update, General, Bathroom Science
|
Wed Jul 1 12:50:40 2020, gautam, Update, PEM, MC1 accelerometers plugged in 
|
Wed Jul 1 08:51:52 2020, Jordan, Update, General, Presence at 40m
|
Tue Jun 30 22:00:04 2020, gautam, Update, Electronics, Glitchy POX resurfaces
|
Tue Jun 30 08:50:12 2020, Jordan, Update, General, Presence at 40m
|
Thu Jun 4 20:54:40 2020, gautam, Update, SUS, MC1 Slow Bias issues
|
Thu Jun 4 21:32:00 2020, Koji, Update, SUS, MC1 Slow Bias issues
|
Thu Jun 25 15:11:00 2020, gautam, Update, SUS, MC1 coil driver resistance quartered
|
Sun Jun 28 15:30:52 2020, gautam, Update, SUS, MC1 sat-box de-lidded
|
Sun Jun 28 16:29:58 2020, rana, Update, SUS, MC1 sat-box de-lidded
|
Sun Jun 28 17:36:35 2020, gautam, Update, SUS, MC1 sat-box de-lidded
|
Mon Jun 29 11:55:46 2020, gautam, Update, SUS, MC1 sat-box de-lidded
|
Mon Jun 29 20:30:53 2020, Koji, Update, SUS, MC1 sat-box de-lidded
|
Mon Jun 29 11:41:04 2020, Jordan, Update, General, Presence at 40m
|
Fri Jun 26 11:00:52 2020, Jordan, Update, General, Presence at 40m
|
Thu Jun 25 11:09:01 2020, Jordan, Update, General, Presence at 40m
|
Wed Jun 24 22:47:21 2020, Yehonathan, Update, Wiki, Updated phase maps webpage
|
Wed Jun 24 22:33:44 2020, gautam, Update, SUS, EQ tripped all suspensions
|
Wed Jun 24 10:14:56 2020, Jordan, Update, General, Presence at 40m
|
Mon Jun 22 10:43:25 2020, Jon, Configuration, VAC, Vac maintenance at 11 am
|
Mon Jun 22 20:06:06 2020, Jon, Configuration, VAC, Vac maintenance complete
|
Tue Jun 23 17:54:56 2020, rana, Configuration, VAC, Vac maintenance complete
|
Mon Jun 22 17:51:50 2020, gautam, Update, CDS, c1iscaux was down
|
Mon Jun 22 13:16:38 2020, Jordan, Update, General, Presence at 40m
|
Fri Jun 19 19:21:25 2020, gautam, Update, General, PSL shutter re-opened
|
Fri Jun 19 14:03:50 2020, Jordan, Update, VAC, Forepump Tip Seal Replacement
|
Fri Jun 19 11:02:10 2020, Chub, Update, General, custom feedthrough flanges are here!
|
Thu Jun 11 11:48:43 2020, gautam, Update, VAC, Vac failure
|
Thu Jun 11 16:14:03 2020, gautam, Update, VAC, Vac failure - probable cause is serial comm glitch  
|
Thu Jun 11 17:35:34 2020, gautam, Update, VAC, Pumpspool UPS needs battery replacement
|
Fri Jun 12 01:23:32 2020, Koji, Update, VAC, Pumpspool UPS needs battery replacement
|
Fri Jun 12 17:32:40 2020, Koji, Update, VAC, Pumpspool UPS needs battery replacement
|
Fri Jun 12 19:02:52 2020, gautam, Update, VAC, Pumpspool UPS needs battery replacement
|
Fri Jun 12 19:23:56 2020, Koji, Update, VAC, Pumpspool UPS needs battery replacement
|
Fri Jun 12 19:33:31 2020, gautam, Update, VAC, Pumpspool UPS needs battery replacement
|
Tue Jun 16 13:35:03 2020, Jon, Update, VAC, Temporary vac fix / IFO usable again
|
Wed Jun 17 16:27:51 2020, gautam, Update, VAC, Questions/comments on vacuum
|
Thu Jun 18 11:00:24 2020, Jon, Update, VAC, Questions/comments on vacuum
|
Thu Jun 18 12:00:36 2020, gautam, Update, VAC, Questions/comments on vacuum
|
Thu Jun 18 14:13:03 2020, Jon, Update, VAC, Questions/comments on vacuum
|
Thu Jun 18 15:46:34 2020, gautam, Update, VAC, Questions/comments on vacuum
|
Fri Jun 19 07:40:49 2020, Jon, Update, VAC, Questions/comments on vacuum
|
Fri Jun 19 09:57:35 2020, gautam, Update, VAC, Questions/comments on vacuum
|
Fri Jun 19 08:47:10 2020, Jordan, Update, General, Presence at 40m
|
Thu Jun 18 22:33:57 2020, Jon, Omnistructure, VAC, Vac hardware purchase list
|
Thu Jun 18 15:25:08 2020, Jordan, Update, VAC, TP2 and TP3 Forepump removal
|
Thu Jun 18 16:56:34 2020, Jordan, Update, VAC, TP2 and TP3 Forepump removal
|
Thu Jun 18 09:46:03 2020, Jordan, Update, General, Presence at 40m
|
Tue Jun 16 16:05:26 2020, Jordan, Update, General, N2 Replacement
|
Wed May 20 19:34:58 2020, Koji, Update, General, ITM spares and New PR3 mirrors transported to Downs for phasemap measurement
|
Thu Jun 4 00:21:28 2020, Koji, Summary, COC, ITM spares and New PR3 mirrors transported to Downs for phasemap measurement
|
Tue Jun 16 13:05:36 2020, Koji, Update, COC, ITM spares and New PR3 mirrors transported to Downs for phasemap measurement
|
Tue Jun 16 08:58:11 2020, Jordan, Update, General, Presence at 40m
|
Fri Jun 12 11:40:14 2020, Jordan, Update, General, Presence at 40m
|
Thu Jun 11 11:14:12 2020, Jordan, Update, General, Presence at 40m
|
Sat Jun 6 14:07:30 2020, Jon, Update, BHD, Stock-Part Mode-Matching Telescope Option 
|
Mon Jun 8 11:50:02 2020, Hang, Update, BHD, Astigmatism and scattering plots 6x
|
Mon Jun 8 12:49:07 2020, Koji, Update, BHD, Astigmatism and scattering plots
|
Mon Jun 8 17:40:22 2020, Jon, Update, BHD, Astigmatism and scattering plots
|
Mon Jun 8 21:45:47 2020, Jon, Update, BHD, Astigmatism and scattering plots
|
Thu Jun 11 09:37:38 2020, Jon, Update, BHD, Conclusions on Mode-Matching Telescopes
|
Wed Jun 10 14:00:33 2020, Jordan, Update, General, Presence at 40m
|
Tue Jun 9 15:02:56 2020, eHang, Update, BHD, Astigmatism and scattering plots  
|
Tue Jun 2 14:05:24 2020, Hang, Update, BHD, MM telescope actuation range requirments 
|
Tue Jun 9 14:55:43 2020, Jon, Update, BHD, MM telescope actuation range requirments
|
Tue Jun 9 09:35:02 2020, Jordan, Update, General, Presence at 40m
|
Mon Jun 8 18:14:55 2020, gautam, Update, CDS, Vertex FEs crashed
|
Fri Jun 5 08:44:50 2020, Jordan, Update, General, Presence at 40m
|
Thu Jun 4 08:45:41 2020, Jordan, Update, General, Presence at 40m
|
Wed Jun 3 19:19:11 2020, gautam, Update, SUS, All watchdogs tripped
|
Wed Jun 3 11:20:19 2020, gautam, Update, DetChar, Summary pages
|
Tue May 26 01:58:57 2020, gautam, Update, Electronics, Some electronics thoughts 
|
Wed Jun 3 01:40:13 2020, gautam, Update, Electronics, More electronics woes 
|
Tue May 26 19:19:30 2020, Hang, Update, BHD, BHD MM-- effects of astigmatism
|
Tue May 26 10:04:54 2020, Jordan, Update, General, N2 Replacement
|
Fri May 22 10:14:47 2020, Jordan, Update, General, Nitrogen Replacement
|
Fri May 22 01:43:18 2020, gautam, Update, Electronics, RF electronics trouble
|
Wed May 20 18:45:22 2020, Hang, Update, BHD, BHD mode-matching study--corner plot & adjustment requirement 
|
Sat May 9 17:01:08 2020, Yehonathan, Update, Loss Measurement, 40m Phase maps loss estimation   
|
Wed May 13 15:13:11 2020, Yehonathan, Update, Loss Measurement, 40m Phase maps loss estimation 
|
Thu May 14 12:21:56 2020, Yehonathan, Update, Loss Measurement, 40m Phase maps loss estimation 
|
Thu May 14 19:00:43 2020, Yehonathan, Update, Loss Measurement, 40m Phase maps loss estimation
|
Tue May 19 15:39:04 2020, Yehonathan, Update, Loss Measurement, 40m Phase maps loss estimation
|
Mon May 18 18:00:16 2020, Hang, Update, BHD, BHD mode-matching study
|
Tue May 19 15:24:06 2020, rana, Update, BHD, BHD mode-matching study
|
Fri May 15 19:10:42 2020, gautam, Update, SUS, All watchdogs tripped, now restored
|
Fri May 15 09:18:04 2020, Jon, Update, BHD, BHD telescope designs accounting for ASC 
|
Tue May 12 17:51:25 2020, rana, Summary, Computer Scripts / Programs, updated LESS syntax highlight on nodus
|
Thu May 14 00:47:55 2020, gautam, Summary, Computer Scripts / Programs, pcdev1 added to authorized keys on nodus
|
Thu May 14 00:21:03 2020, gautam, Update, LSC, CM board boosts 
|
Tue May 12 18:16:17 2020, gautam, Update, LSC, Relative importance of losses in the arm and PRC
|
Tue May 12 20:16:31 2020, Koji, Update, LSC, Relative importance of losses in the arm and PRC
|
Tue May 12 22:47:49 2020, gautam, Update, LSC, Relative importance of losses in the arm and PRC
|
Mon May 11 00:12:34 2020, gautam, Update, LSC, RF only PRFPMI   
|
Fri May 8 14:27:25 2020, Hang, Update, BHD, New SRC gouy phase 
|
Tue May 5 23:44:14 2020, gautam, Update, ASC, IMC WFS 
|
Thu May 7 09:43:21 2020, rana, Update, ASC, IMC WFS
|
Thu May 7 10:58:06 2020, gautam, Update, ASC, IMC WFS
|
Wed May 6 00:31:09 2020, gautam, Update, ALS, Optomechanics during CARM offset reduction 
|
Fri May 1 01:49:55 2020, gautam, Update, ALS, ASY commissioning
|
Fri May 1 22:44:17 2020, gautam, Update, ALS, ASY M2 PZT damaged
|
Sat May 2 02:35:18 2020, Koji, Update, ALS, ASY M2 PZT damaged
|
Thu Apr 30 07:29:01 2020, Chub, Update, VAC, N2 delivered.
|
Fri Apr 24 00:26:59 2020, rana, Summary, PEM, L.A. EQ from Tuesday night
|
Wed Apr 22 17:29:14 2020, gautam, Update, PSL, FSS debugging attempts
|
Thu Apr 23 10:42:02 2020, rana, Update, PSL, FSS debugging attempts
|
Sat Apr 18 13:32:31 2020, rana, Update, Cameras, GigE w better NIR sensitivvity
|
Thu Apr 23 09:52:02 2020, Jon, Update, Cameras, GigE w better NIR sensitivvity
|
Wed Apr 22 13:52:05 2020, gautam, Update, DetChar, Summary page revival
|
Mon Apr 20 17:49:58 2020, gautam, Update, General, Some housekeeping 
|
Tue Mar 10 19:59:09 2020, Yehonathan, Update, Loss Measurement, Arm transfer function measurement
|
Thu Mar 12 10:43:50 2020, rana, Update, Loss Measurement, Arm transfer function measurement
|
Mon Mar 16 15:23:03 2020, Yehonathan, Update, Loss Measurement, Arm transfer function measurement  
|
Sat Apr 18 14:57:44 2020, Yehonathan, Update, Loss Measurement, Arm transfer function measurement
|
Fri Jan 24 13:56:21 2020, Jon, Update, BHD, BHD optics specifications
|
Thu Apr 16 21:13:20 2020, Jon, Update, BHD, BHD optics specifications 
|
Wed Apr 15 15:15:17 2020, Chub, Update, VAC, nitrogen cylinders delivered
|
Tue Apr 14 23:50:06 2020, Koji, Update, General, 40m power glitch recovery
|
Mon Apr 13 16:51:49 2020, rana, Summary, DAQ, NODUS: rsyncd daemon / service set up
|
Mon Apr 13 15:28:07 2020, Koji, Update, General, Power Event and recovery
|
Tue Apr 7 15:30:40 2020, Jon, Summary, NoiseBudget, 40m noise budget migrated to pygwinc
|
Fri Apr 3 13:40:07 2020, Jon, Update, BHD, BHD front-end complication
|
Tue Apr 7 10:56:39 2020, Jon, Update, BHD, BHD front-end complication
|
Thu Apr 2 15:53:01 2020, gautam, Update, ASC, PRMI 1f locked for collecting feedforward data
|
Fri Apr 3 17:15:53 2020, gautam, Update, ASC, POP angular FF filters trained and tested    
|
Mon Apr 6 12:26:07 2020, rana, Update, ASC, POP angular FF filters trained and tested
|
Mon Apr 6 16:46:40 2020, gautam, Update, ASC, POP angular FF filters trained and tested
|
Thu Mar 26 22:31:34 2020, Yehonathan, Update, CDS, C1AUXEY wiring + channel list
|
Thu Apr 2 16:31:33 2020, Jon, Update, CDS, C1AUXEY wiring + channel list
|
Thu Apr 2 22:19:18 2020, Koji, Update, CDS, C1AUXEY wiring + channel list
|
Fri Apr 3 12:09:53 2020, Jon, Update, CDS, C1AUXEY wiring + channel list
|
Tue Mar 24 19:41:57 2020, gautam, Update, Wiener, Seismic feedforward for MCL   
|
Wed Apr 1 00:51:41 2020, gautam, Update, Wiener, Slightly improved MCL FF  
|
Tue Mar 31 09:39:41 2020, gautam, Update, CDS, Foton for shaped noise injections
|
Tue Mar 31 23:35:50 2020, rana, Update, CDS, Foton for shaped noise injections
|
Tue Mar 31 23:54:57 2020, gautam, Update, CDS, Foton for shaped noise injections
|
Mon Mar 30 19:02:49 2020, rana, Update, General, donated cleanroom supplies to Hospitals
|
Thu Mar 26 17:41:18 2020, Jon, Omnistructure, BHD, BHD docs compilation
|
Thu Jan 10 19:59:08 2019, Jon, Update, VAC, Vac System Running Normally on Turbo Pumps  
|
Fri Jan 25 16:14:51 2019, gautam, Update, VAC, Vacuum interlock code, N2 warning
|
Wed Mar 25 15:15:55 2020, gautam, Update, VAC, Vacuum interlock code, N2 warning update
|
Thu Mar 12 01:33:21 2020, gautam, Update, LSC, Resuming locking activities
|
Fri Mar 13 00:32:38 2020, gautam, Update, LSC, Some progress 
|
Tue Mar 17 01:22:03 2020, gautam, Update, LSC, Locking updates
|
Thu Mar 19 03:33:28 2020, gautam, Update, LSC, More locking updates   
|
Wed Mar 18 21:43:26 2020, gautam, Update, VAC, Main vol pressure jump
|
Wed Mar 18 22:10:41 2020, Koji, Update, VAC, Main vol pressure jump
|
Fri Mar 13 20:00:50 2020, Jon, Update, Computers, Loopback monitoring for slow machines
|
Fri Mar 13 14:28:39 2020, gautam, Update, PSL, Added tees to PMC Trans and REFL
|
Fri Mar 13 12:48:47 2020, Larry Wallace, Update, elog, Cert Renewal
|
Thu Mar 12 16:13:16 2020, gautam, Update, PSL, Temperature sensors connected to Acromag
|
Thu Mar 12 11:10:49 2020, Yehonathan, Update, General, PMC got unlcoked
|
Thu Mar 12 12:44:34 2020, gautam, Update, General, PMC got unlcoked
|
Wed Mar 11 21:03:57 2020, Koji, Update, BHD, SOS packages from Syracuse
|
Mon Mar 2 16:29:40 2020, gautam, Update, Electronics, c1psl VME crate removed, Acro-crate installed
|
Tue Mar 3 17:20:14 2020, gautam, Update, Electronics, More cabling removed
|
Wed Mar 4 16:18:31 2020, gautam, Update, Electronics, More cabling removed 
|
Wed Mar 4 21:02:49 2020, Koji, Update, Electronics, More cabling removed
|
Tue Mar 3 17:59:33 2020, Yehonathan, Update, Electronics, PSL Shutter and PMC TRANSPD working
|
Thu Mar 5 15:03:48 2020, Yehonathan, Update, Electronics, PSL Shutter and PMC TRANSPD working
|
Thu Mar 5 19:45:23 2020, Jon, Summary, PSL, C1PSL in-situ test results
|
Wed Mar 11 18:12:53 2020, gautam, Summary, PSL, WFS Demod board modifications
|
Tue Feb 25 19:58:06 2020, Hang, Update, IOO, MC2 coil balancing
|
Wed Mar 11 16:46:25 2020, Hang, Update, IOO, MC2 coil balancing
|
Tue Mar 10 14:30:16 2020, yehonathan, Update, SUS,
|
Tue Mar 10 19:58:16 2020, yehonathan, Update, SUS,
|
Sat Mar 7 15:18:30 2020, gautam, Update, SUS, EQ tripped some suspensions
|
Fri Mar 6 01:19:19 2020, gautam, Update, IOO, Excess laser frequency noise  
|
Fri Mar 6 16:33:11 2020, gautam, Update, IOO, Excess laser frequency noise
|
Wed Mar 4 20:42:53 2020, gautam, Update, Electronics, C1PSL acromag crate is sitting on the floor
|
Thu Mar 5 11:27:48 2020, gautam, Update, Electronics, C1PSL acromag crate is no longer sitting on the floor
|
Thu Mar 5 19:51:14 2020, gautam, Update, Electronics, IMC Servo board being tested
|
Fri Mar 6 01:12:10 2020, gautam, Update, Electronics, IMC Servo IN2 path looks just fine 
|
Wed Mar 4 22:38:31 2020, Jon, Update, PSL, c1psl communications problem resolved
|
Wed Mar 4 16:54:43 2020, gautam, Update, CDS, c1auxex temporarily disconnected
|
Wed Mar 4 12:25:11 2020, gautam, Update, CDS, BIO1 on c1psl is dead
|
Wed Mar 4 11:16:37 2020, gautam, Update, PSL, PMC realignment
|
Wed Mar 4 11:10:47 2020, Yehonathan, Update, Computers, Allegra revival
|
Tue Mar 3 19:11:48 2020, gautam, Update, LSC, Some locking prep
|
Wed Feb 26 21:43:48 2020, Jon, Summary, BHD, Projected IFO noise budget, post-BHD upgrade   
|
Wed Feb 26 22:09:52 2020, gautam, Summary, BHD, Projected IFO noise budget, post-BHD upgrade
|
Mon Mar 2 23:49:03 2020, Jon, Summary, BHD, Projected IFO noise budget, post-BHD upgrade  
|
Tue Mar 3 18:11:05 2020, Jon, Summary, BHD, Projected IFO noise budget, post-BHD upgrade  
|
Mon Mar 2 19:32:41 2020, gautam, Update, CDS, c1rfm errors
|
Mon Mar 2 16:35:12 2020, gautam, Update, CDS, c1psl test status
|
Mon Mar 2 16:14:47 2020, gautam, Update, CDS, some target directory cleanup
|
Thu Feb 27 17:50:36 2020, gautam, Update, PSL, c1psl setup setup  
|
Fri Feb 28 08:05:22 2020, gautam, Update, PSL, c1psl setup setup
|
Fri Feb 28 10:04:41 2020, gautam, Update, PSL, c1psl setup setup
|
Fri Feb 28 19:37:18 2020, gautam, Update, PSL, New c1psl installed
|
Thu Feb 27 22:45:40 2020, gautam, Update, ALS, ALS noise high
|
Thu Feb 27 17:59:02 2020, gautam, Update, LSC, Some AO thoughts
|
Thu Feb 27 15:50:37 2020, gautam, Update, Electronics, FSS box power cable removed
|
Wed Feb 26 22:05:06 2020, gautam, Update, IOO, IMC checks
|
Wed Feb 26 23:50:51 2020, gautam, Update, IOO, IMC checks 
|
Wed Feb 26 17:17:17 2020, Yehonathan, Update, , Arms DC loss measurements 6x
|
Tue Feb 25 16:17:57 2020, Gautam, Hang, Update, CDS,
|
Mon Feb 24 08:36:32 2020, Chub, Update, General, HVAC repair
|
Thu Feb 13 21:30:55 2020, shruti, Update, ALS, ALS OOL noise with arms locked
|
Fri Feb 14 14:02:13 2020, shruti, Update, ALS, ALS OOL noise with arms locked  
|
Fri Feb 14 14:52:41 2020, gautam, Update, ALS, ALS OOL noise with arms locked
|
Tue Feb 18 18:14:59 2020, shruti, Update, ALS, ALS OOL noise with arms locked
|
Wed Feb 19 22:20:22 2020, rana, Update, ALS, ALS OOL noise with arms locked
|
Fri Feb 21 10:59:08 2020, shruti, Update, ALS, PDH error signals?   
|
Fri Feb 21 13:02:53 2020, Koji, Update, ALS, PDH error signals?
|
Fri Feb 21 20:44:18 2020, shruti, Update, ALS, ALS OOL noise and PDH 
|
Sun Feb 23 18:15:22 2020, rana, Update, ALS, ALS OOL noise and PDH
|
Fri Dec 27 16:26:11 2019, Yehonathan, Update, PSL, PMC Linewidth measurement
|
Wed Jan 1 14:14:00 2020, Yehonathan, Update, PSL, PMC Linewidth measurement 
|
Wed Jan 15 15:04:31 2020, gautam, Update, PSL, PMC Linewidth measurement
|
Fri Jan 17 22:11:19 2020, Yehonathan, Update, PSL, Ringdown measurements 
|
Sat Jan 25 11:54:42 2020, Yehonathan, Update, PSL, Ringdown measurements    
|
Mon Jan 27 21:35:06 2020, Yehonathan, Update, PSL, Ringdown measurements
|
Mon Jan 27 21:48:49 2020, gautam, Update, PSL, Ringdown measurements
|
Tue Jan 28 16:01:17 2020, gautam, Update, IOO, IMC WFS servos stable again
|
Tue Jan 28 20:51:37 2020, Yehonathan, Update, IOO, IMC WFS servos stable again
|
Wed Jan 29 12:40:24 2020, Yehonathan, Update, IOO, IMC Ringdowns preliminary data analysis 
|
Mon Feb 3 13:54:10 2020, Yehonathan, Update, IOO, IMC Ringdowns extended data analysis
|
Wed Feb 5 21:13:17 2020, Yehonathan, Update, IOO, IMC Ringdowns extended data analysis
|
Sat Feb 15 12:56:24 2020, Yehonathan, Update, IOO, IMC Transfer function measurement  
|
Thu Feb 13 01:47:39 2020, gautam, Update, ALS, Fast ALS - delay line prep  
|
Fri Feb 14 00:53:50 2020, gautam, Update, ALS, Fast ALS - more setup 
|
Wed Feb 12 12:13:37 2020, gautam, Update, LSC, AO path attempts 
|
Thu Feb 13 02:07:26 2020, gautam, Update, LSC, AO path transfer function measurement 
|
Tue Feb 11 19:11:35 2020, shruti, Update, Computer Scripts / Programs, MATLAB on donatella
|
Tue Feb 11 16:39:00 2020, shruti, Update, ALS, AM/PM    
|
Mon Feb 10 15:55:46 2020, Jordan, Update, PSL, PMCTRANSPD
|
Mon Feb 10 15:54:47 2020, Jordan, Update, PSL, Completed Acromag Wiring
|
Mon Feb 10 15:04:42 2020, Jordan, Update, General, HDMI Routing for new tv
|
Mon Feb 10 10:07:20 2020, gautam, Update, PSL, PMC re-locked
|
Mon Feb 10 09:40:54 2020, Larry Wallace, Summary, General, SolidWorks Computer Upgrade and Printer repair
|
Fri Feb 7 15:00:16 2020, gautam, Update, LSC, More high BW POY experiments
|
Fri Feb 7 19:39:10 2020, Koji, Update, LSC, More high BW POY experiments
|
Fri Jan 31 16:57:09 2020, gautam, Update, General, Metal PMC parts
|
Fri Feb 7 12:58:25 2020, Yehonathan, Update, General, Metal PMC parts 18x
|
Fri Feb 7 09:45:03 2020, shruti, Update, General, AM at X end
|
Thu Feb 6 16:14:44 2020, rana, Update, General, office area temperature
|
Fri Feb 7 02:41:28 2020, Koji, Update, General, office area temperature
|
Tue Feb 4 02:13:02 2020, gautam, Update, LSC, Locking updates 
|
Wed Feb 5 16:35:12 2020, gautam, Update, LSC, Diagnosis plan
|
Thu Feb 6 01:16:58 2020, gautam, Update, LSC, Diagnosis results 
|
Thu Feb 6 01:25:50 2020, gautam, Update, LSC, Locking updates 
|
Fri Feb 7 02:24:24 2020, gautam, Update, LSC, Some short notes
|
Thu Feb 6 21:54:13 2020, Jon, Update, PSL, c1psl bench testing complete
|
Tue Feb 4 18:13:01 2020, Yehonathan, Update, PSL, Bench testing of PSL ai channels
|
Wed Feb 5 08:57:11 2020, Yehonathan, Update, PSL, Bench testing of PSL ai channels
|
Wed Feb 5 21:04:10 2020, Yehonathan, Update, PSL, Bench testing of PSL ai channels
|
Mon Feb 3 15:22:39 2020, Jon, Update, PSL, c1psl progress/Acromag ADC grounding
|
Fri Jan 31 16:04:30 2020, gautam, Update, IOO, Input pointing drift 
|
Wed Jan 29 12:29:33 2020, shruti, Update, General, delay line frequency discriminator for PM 
|
Thu Jan 30 15:24:10 2020, ?, Update, General, delay line frequency discriminator for PM
|
Thu Jan 30 22:02:42 2020, shruti, Update, General, delay line frequency discriminator for PM
|
Thu Jan 30 17:31:28 2020, Jon, Update, PSL, Errant FSS_INOFFSET change
|
Thu Jan 30 17:41:10 2020, gautam, Update, PSL, Errant FSS_INOFFSET change
|
Thu Jan 30 12:52:10 2020, Jon, Update, BHD, Metal OMCs procured
|
Wed Jan 29 03:05:47 2020, rana, gautam, Update, SUS, MC misalignments / sat box games
|
Wed Jan 29 00:29:43 2020, gautam, Update, LSC, locking 2020
|
Wed Jan 29 00:27:13 2020, gautam, Update, Computer Scripts / Programs, mcup / mcdown modified
|
Tue Dec 3 22:41:17 2019, shruti, Update, General, PLL for PM measurement
|
Wed Dec 4 20:32:43 2019, gautam, Update, General, PLL for PM measurement
|
Mon Dec 9 21:22:46 2019, shruti, Update, General, PLL / PM measurement of Xend NPRO PZT
|
Tue Dec 17 20:08:09 2019, shruti, Update, General, PLL / PM measurement of Xend NPRO PZT
|
Thu Jan 16 19:32:23 2020, shruti, Update, General, PLL / PM measurement of Xend NPRO PZT
|
Thu Jan 23 20:08:49 2020, shruti, Update, General, PLL / PM measurement of Xend NPRO PZT
|
Tue Jan 28 19:40:15 2020, shruti, Update, General, PLL / PM measurement of Xend NPRO PZT 
|
Tue Jan 28 19:12:30 2020, Jon, Configuration, PSL, Spare channels added to c1psl chassis
|
Sun Dec 8 20:48:29 2019, rana, Configuration, Computers, Megatron: starts up grade
|
Wed Dec 11 22:01:24 2019, rana, Configuration, Computers, Megatron: starts up grade
|
Wed Jan 22 19:17:20 2020, gautam, Configuration, Computers, Megatron: starts up grade
|
Thu Jan 23 15:32:42 2020, gautam, Configuration, Computers, Megatron: starts up grade
|
Mon Jan 27 18:16:30 2020, gautam, Configuration, Computers, Sluggish megatron?
|
Tue Jan 28 15:39:04 2020, gautam, Configuration, Computers, Sluggish megatron?
|
Tue Jan 28 17:36:45 2020, gautam, Configuration, Computers, Local EPICS7.0 installed on megatron
|
Mon Jan 20 20:20:36 2020, gautam, Update, PSL, PMC servo checkout 
|
Wed Jan 22 11:22:39 2020, gautam, Update, PSL, PMC modulation depth measurement
|
Wed Jan 22 20:12:36 2020, gautam, Update, PSL, PMC demodulator electrical characterization 
|
Thu Jan 23 14:37:05 2020, gautam, Update, PSL, PMC VGA chip damaged?
|
Thu Jan 23 16:37:14 2020, rana, Update, PSL, PMC VGA chip damaged?
|
Thu Jan 23 22:10:01 2020, gautam, Update, PSL, PMC servo pulled out
|
Fri Jan 24 15:42:08 2020, gautam, Update, PSL, PMC servo restored
|
Sun Jan 26 13:47:00 2020, gautam, Update, PSL, PMC servo characterization   
|
Tue Jan 28 14:33:24 2020, gautam, Update, PSL, Inferred free-running frequency noise 
|
Thu Jan 23 18:52:31 2020, gautam, Update, PSL, PMC RFPD characterization
|
Tue Jan 28 08:26:53 2020, rana, Frogs, PEM, shaking
|
Mon Jan 27 14:01:01 2020, Jordan, Configuration, General, Repurposed Sorenson Power Supply
|
Sun Jan 26 14:40:55 2020, gautam, Update, ALS, ALS OOL noise
|
Sun Jan 26 13:30:19 2020, gautam, Update, SUS, All watchdogs tripped, now restored
|
Fri Jan 17 18:02:21 2020, gautam, Update, ALS, Gain blocks packaged and characterized    
|
Fri Jan 24 17:14:01 2020, gautam, Update, ALS, Gain blocks installed
|
Thu Jan 23 23:07:04 2020, Jon, Configuration, PSL, c1psl breakout board wiring
|
Wed Jan 22 16:19:47 2020, Jon, Update, VAC, TP3 controller errors
|
Mon Dec 9 19:19:04 2019, Yehonathan, Update, PSL, AOM first order beam alignment   
|
Tue Dec 10 01:24:17 2019, Yehonathan, Update, PSL, AOM first order beam alignment
|
Tue Dec 10 13:26:46 2019, Yehonathan, Update, PSL, AOM first order beam alignment
|
Fri Jan 17 21:56:22 2020, Yehonathan, Update, PSL, AOM first order beam alignment
|
Wed Jan 22 11:00:21 2020, gautam, Update, PSL, PMC REFL ghost beam
|
Mon Jan 20 15:11:20 2020, gautam, Update, PSL, PMCT photodiode grounding issue
|
Mon Jan 20 12:16:50 2020, gautam, Update, PSL, PMC input reverted to AOM zeroth order beam
|
Wed Jan 15 16:54:51 2020, gautam, Update, General, PDA10CF removed from AS table
|
Mon Jan 6 15:36:55 2020, Jon, Update, PSL, Assembly underway for c1psl upgrade
|
Mon Jan 6 16:07:12 2020, gautam, Update, PSL, Assembly underway for c1psl upgrade
|
Mon Jan 6 19:05:09 2020, not gautam, Update, PSL, Assembly underway for c1psl upgrade
|
Fri Jan 10 19:48:46 2020, yehonathan, Update, PSL, Assembly underway for c1psl upgrade 
|
Mon Jan 13 16:05:18 2020, yehonathan, Update, PSL, Assembly underway for c1psl upgrade
|
Tue Jan 14 17:16:43 2020, yehonathan, Update, PSL, Assembly underway for c1psl upgrade
|
Wed Jan 15 10:12:46 2020, gautam, Update, PSL, Assembly underway for c1psl upgrade
|
Wed Jan 15 16:08:40 2020, not gautam, Update, PSL, Assembly underway for c1psl upgrade
|
Wed Jan 15 14:10:28 2020, Jon, Configuration, PSL, New EPICS database for C1PSL + C1IOO
|
Mon Jan 13 23:30:53 2020, Yehonathan, Summary, PSL, Changes made since Gautam left
|
Tue Jan 14 20:17:09 2020, gautam, Summary, General, IFO recovery
|
Wed Jan 15 10:04:19 2020, gautam, Summary, General, POX / POY locking restored
|
Mon Jan 13 15:47:37 2020, shruti, Configuration, Computer Scripts / Programs, c1psl burt restore
|
Fri Jan 10 14:21:19 2020, Yehonathan, Update, PSL, c1psl reboot
|
Tue Jan 7 18:51:51 2020, Jon, Update, PSL, New c1psl server assembled
|
Mon Nov 4 19:02:25 2019, Yehonathan, Update, PSL, Mapping the PSL electronics
|
Tue Dec 17 00:23:28 2019, Yehonathan, Update, PSL, Mapping the PSL electronics
|
Tue Dec 17 18:05:06 2019, Yehonathan, Update, PSL, Mapping the PSL electronics
|
Fri Dec 20 18:33:21 2019, Yehonathan, Update, PSL, Mapping the PSL electronics
|
Mon Dec 23 19:30:20 2019, Yehonathan, Update, PSL, Mapping the PSL electronics
|
Wed Jan 1 04:53:11 2020, gautam, Update, PSL, Mapping the PSL electronics
|
Wed Jan 1 16:04:37 2020, Yehonathan, Update, PSL, Mapping the PSL electronics
|
Wed Dec 11 15:01:57 2019, Jon, Summary, PSL, PMC cavity ringdown measurement
|
Thu Dec 12 19:20:43 2019, Yehonathan, Update, PSL, PMC cavity ringdown measurement  
|
Fri Dec 13 12:28:43 2019, Yehonathan, Update, PSL, PMC cavity ringdown measurement
|
Tue Dec 17 20:45:30 2019, rana, Update, PSL, PMC cavity ringdown measurement
|
Fri Dec 27 15:01:02 2019, Yehonathan, Update, PSL, PMC cavity ringdown measurement   
|
Tue Dec 31 03:03:02 2019, gautam, Update, PSL, PMC cavity ringdown measurement
|
Mon Dec 16 18:19:42 2019, shruti, Update, PSL, PMC cavity ringdown measurement : beat-note disruption
|
Tue Dec 10 15:17:17 2019, Yehonathan, Update, PSL, PMC is locked
|
Tue Dec 10 18:27:22 2019, Yehonathan, Update, PSL, PMC is locked
|
Wed Dec 11 15:29:17 2019, Yehonathan, Update, PSL, PMC is locked
|
Fri Dec 6 17:49:46 2019, rana, Summary, PEM, Jump test of seismometers: EX needs recentering 
|
Sun Dec 8 20:15:41 2019, rana, Summary, PEM, Jump test of seismometers: EX needs recentering
|
Mon Dec 9 13:08:24 2019, Yehonathan, Summary, PEM, Jump test of seismometers: EX needs recentering
|
Sun Dec 8 20:27:11 2019, rana, Update, Computers, Viviana upgrade to Ubuntu 16
|
Fri Dec 6 15:22:01 2019, gautam, Frogs, LSC, DAFI system revived
|
Tue Oct 8 18:35:09 2019, gautam, Update, LSC, Locking prep
|
Wed Oct 9 18:15:26 2019, gautam, Update, LSC, PRMI 3f locking
|
Wed Oct 9 22:02:58 2019, gautam, Update, LSC, REFL55 whitening issue
|
Thu Oct 10 01:12:56 2019, gautam, Update, LSC, Locking studies
|
Wed Oct 16 11:42:17 2019, gautam, Update, LSC, Poor separation of PRCL/MICH in 3f signals
|
Thu Oct 17 11:19:28 2019, gautam, Update, LSC, Locking activity last night 
|
Tue Oct 22 00:52:27 2019, gautam, Update, LSC, Locking updates
|
Tue Oct 29 01:24:45 2019, gautam, Update, LSC, More locking updates 
|
Tue Oct 29 15:13:19 2019, gautam, Update, LSC, More locking updates
|
Wed Oct 30 01:27:00 2019, gautam, Update, LSC, More locking updates
|
Wed Oct 30 11:53:41 2019, gautam, Update, LSC, MICH loop shape tuning 
|
Wed Oct 30 17:08:40 2019, gautam, Update, LSC, POP22 investigation
|
Mon Nov 4 15:29:47 2019, gautam, Update, LSC, POP signal path
|
Mon Nov 4 16:06:58 2019, gautam, Update, LSC, POP optical path    
|
Tue Nov 5 11:52:27 2019, gautam, Update, LSC, Locking notes
|
Wed Nov 6 02:08:48 2019, gautam, Update, LSC, Locking updates
|
Wed Nov 6 17:05:45 2019, gautam, Update, LSC, CARM calibration  
|
Wed Nov 6 17:45:34 2019, gautam, Update, LSC, ~
|
Mon Nov 18 21:04:38 2019, gautam, Update, LSC, Locking - some ideas
|
Wed Nov 20 01:07:18 2019, gautam, Update, LSC, Locking - progress
|
Wed Nov 20 12:14:17 2019, gautam, Update, LSC, Locking - progress
|
Wed Nov 20 17:20:24 2019, Yehonathan, Update, LSC, QPD Investigation
|
Wed Nov 20 17:52:00 2019, gautam, Update, LSC, QPD MEDM screen update  
|
Wed Nov 20 21:29:28 2019, gautam, Update, LSC, PRG ~13
|
Fri Nov 22 00:54:14 2019, gautam, Update, LSC, locking notes
|
Mon Nov 25 19:11:22 2019, gautam, Update, LSC, ALS noise re-look
|
Wed Nov 27 23:24:01 2019, gautam, Update, LSC, No shaking but no inspiration either
|
Sun Dec 1 13:38:48 2019, rana, Update, LSC, No shaking but no inspiration either
|
Tue Dec 3 00:03:57 2019, gautam, Update, LSC, Green ALS also shows elevated noise with high arm buildup
|
Wed Dec 4 19:54:27 2019, gautam, Update, LSC, A look to the past
|
Thu Dec 5 01:54:39 2019, gautam, Update, LSC, Partial CM board path engaged
|
Fri Dec 6 00:02:48 2019, gautam, Update, LSC, What is the correct way to set the 3f offsets?
|
Fri Nov 15 12:08:04 2019, gautam, Update, LSC, POPDC whitening board
|
Tue Oct 29 17:40:48 2019, gautam, Update, LSC, More locking updates 
|
Thu Dec 5 18:15:01 2019, gautam, Update, Optical Levers, ITM, PRM and BS Oplevs re-centered
|
Thu Dec 5 15:09:50 2019, gautam, Update, CDS, c1oaf crashed c1lsc 
|
Thu Dec 5 14:54:15 2019, gautam, Update, General, Symlink to SRmeasure and AGmeasure
|
Thu Dec 5 08:44:44 2019, Gavin, Update, Loss Measurement, Q Measurements of Test Masses
|
Fri Jun 8 14:40:55 2018, c1lsc, Update, CDS, i am dead
|
Fri Jun 8 20:15:08 2018, gautam, Update, CDS, Reboot script
|
Mon Jun 11 18:49:06 2018, gautam, Update, CDS, c1lsc dead again
|
Wed Dec 4 09:11:42 2019, Yehonathan, Update, CDS, Reboot script
|
Wed Dec 4 12:13:10 2019, gautam, Update, CDS, Reboot script
|
Wed Dec 4 08:54:07 2019, Yehonathan, Update, IMC, Mirror analog shaking
|
Mon Dec 2 00:27:20 2019, gautam, Update, ALS, Green ALS resurrection  
|
Mon Dec 2 18:20:29 2019, gautam, Update, ALS, EY uPDH post mixer LPF 
|
Mon Dec 2 20:18:18 2019, rana, Update, ALS, EY uPDH post mixer LPF
|
Tue Dec 3 18:15:42 2019, gautam, Update, ALS, EY uPDH post mixer LPF
|
Tue Dec 3 21:28:24 2019, gautam, Update, ALS, EY uPDH post mixer LPF
|
Tue Dec 3 00:10:15 2019, Koji, Update, ALS, EY uPDH post mixer LPF
|
Tue Dec 3 00:51:25 2019, gautam, Update, ALS, EY uPDH post mixer LPF
|
Tue Dec 3 20:32:37 2019, rana, Omnistructure, DAQ, NDS2 situation 
|
Wed Nov 27 18:51:22 2019, Gavin Wallace, Update, IMC, Q Measurement of Test Masses
|
Tue Dec 3 14:52:13 2019, rana, Update, IMC, Q Measurement of Test Masses
|
Mon Dec 2 23:01:47 2019, gautam, Update, CDS, Frequent DTT crashes on pianosa
|
Wed Nov 27 17:51:52 2019, gautam, Update, Wiener, MCL FF status 
|
Tue Nov 26 17:07:41 2019, gautam, Update, LSC, POX / POY calibration 
|
Tue Nov 26 18:16:08 2019, rana, Update, LSC, POX / POY calibration
|
Wed Nov 27 12:16:52 2019, gautam, Update, LSC, ITMX and ITMY OSEMs with low and high circulating power 
|
Wed Nov 27 13:14:02 2019, rana, Update, LSC, ITMX and ITMY OSEMs with low and high circulating power
|
Wed Nov 27 16:10:29 2019, gautam, Update, LSC, AOM reconnected
|
Tue Nov 26 13:33:33 2019, Yehonathan, Update, Cameras, MC2 Camera rotated by 90 degrees 
|
Mon Nov 25 22:10:26 2019, shruti, Update, NoiseBudget, Diagnostics  
|
Thu Nov 21 12:46:22 2019, gautam, Update, LSC, CM board study
|
Thu Nov 21 13:14:33 2019, Koji, Update, LSC, CM board study
|
Thu Nov 21 19:08:58 2019, gautam, Update, LSC, High BW lock of Y arm length to PSL frequency  
|
Tue Oct 8 08:08:18 2019, gautam, Update, PEM, PEM BLRMS anomaly
|
Wed Oct 23 11:49:21 2019, gautam, Update, PEM, PEM BLRMS anomaly 
|
Thu Oct 24 18:37:15 2019, gautam, Update, PEM, T240 checkout
|
Tue Nov 5 12:37:50 2019, gautam, Update, PEM, T240 interface unit pulled out 
|
Wed Nov 13 19:34:45 2019, gautam, Update, PEM, Follow-up on seismometer discussion 
|
Wed Nov 13 20:15:56 2019, rana, Update, PEM, Follow-up on seismometer discussion
|
Wed Nov 13 23:40:15 2019, gautam, Update, PEM, Follow-up on seismometer discussion
|
Thu Nov 14 12:11:04 2019, rana, Update, PEM, Follow-up on seismometer discussion
|
Fri Nov 15 00:18:41 2019, rana, Update, PEM, Follow-up on seismometer discussion
|
Fri Nov 15 12:16:48 2019, gautam, Update, PEM, Follow-up on seismometer discussion
|
Mon Nov 18 14:32:53 2019, gautam, Update, PEM, Follow-up on seismometer discussion
|
Tue Nov 19 21:53:57 2019, gautam, Update, PEM, Follow-up on seismometer discussion
|
Tue Nov 19 15:08:48 2019, gautam, Update, CDS, Vertex models rebooted
|
Fri Nov 15 18:59:08 2019, rana, Update, Computers, ZITA: started upgrade from Ubuntu 14 LTS to 18 LTS
|
Mon Nov 18 16:32:15 2019, gautam, Update, Computers, ZITA: started upgrade from Ubuntu 14 LTS to 18 LTS
|
Mon Nov 4 11:41:28 2019, shruti, Update, Computer Scripts / Programs, Epics installed on donatella
|
Thu Nov 7 17:55:37 2019, shruti, Update, Computer Scripts / Programs, Python packages on donatella
|
Fri Oct 18 20:21:33 2019, shruti, Update, ALS, AM measurement attempt at X end
|
Thu Nov 7 17:46:10 2019, shruti, Update, ALS, AM measurement at X end
|
Mon Sep 12 23:54:10 2011, kiwamu, Update, IOO, EOM resonant box installed  
|
Wed Nov 6 20:34:28 2019, Koji, Update, IOO, Power combiner loss (EOM resonant box installed)
|
Wed Nov 6 19:26:57 2019, gautam, Update, PSL, Some PSL cable admin
|
Sat Nov 2 16:36:55 2019, Yehonathan, Update, PSL, Up to date sketch of the 1x1 and 1x2 Eurocrates
|
Sat Nov 2 17:08:34 2019, Yehonathan, Update, PSL, Up to date sketch of the 1x1 and 1x2 Eurocrates
|
Mon Nov 4 13:26:04 2019, Yehonathan, Update, PSL, Up to date sketch of the 1x1 and 1x2 Eurocrates
|
Thu Oct 31 10:44:40 2019, gautam, Update, PSL, PMC re-locked
|
Wed Oct 30 19:20:27 2019, gautam, Update, SUS, PRM suspension issues   
|
Wed Oct 30 23:12:27 2019, Koji, Update, SUS, PRM suspension issues
|
Mon Oct 21 12:25:46 2019, gautam, Update, ALS, DFD electronics checkout   
|
Tue Oct 22 15:32:15 2019, gautam, Update, ALS, EX uPDH electronics checkout
|
Wed Oct 23 10:23:26 2019, rana, Update, ALS, EX uPDH electronics checkout
|
Wed Oct 23 11:11:01 2019, gautam, Update, ALS, EX uPDH electronics checkout
|
Fri Oct 25 01:04:49 2019, gautam, Update, ALS, ALS electronics chain was saturating
|
Mon Oct 28 23:20:11 2019, gautam, Update, ALS, ALS power budget
|
Thu Oct 24 11:58:16 2019, gautam, Update, ASC, PRC angular feedforward
|
Wed Oct 23 18:40:58 2019, gautam, Update, CDS, another round of vertex FE reboots
|
Thu Oct 17 16:49:53 2019, gautam, Update, ASC, PRMI ASC - first pass
|
Tue Oct 22 17:35:30 2019, gautam, Update, ASC, PRMI ASC - first pass 
|
Wed Oct 23 11:14:21 2019, gautam, Update, ASC, PRMI ASC with QPD signals normalized. 
|
Fri Oct 18 17:35:07 2019, gautam, Update, SUS, ETMX sat box disconnected
|
Mon Oct 21 16:02:21 2019, gautam, Update, SUS, ETMX over the weekend
|
Fri Oct 18 18:13:55 2019, Koji, Update, safety, Laser interlock looks OK
|
Mon Oct 21 11:44:19 2019, gautam, Update, safety, Interlock reconnected to Innolight controller
|
Thu Oct 17 12:34:51 2019, gautam, Update, General, Daytime wishlist 
|
Mon Oct 14 17:24:28 2019, gautam, Update, General, Workstation computers taken off UPS (temporarily)
|
Tue Oct 15 17:22:26 2019, gautam, Update, General, Workstation computers back on UPS
|
Thu Oct 10 23:36:02 2019, Koji, Update, General, Wednesday cleaning work  
|
Tue Oct 15 17:19:38 2019, Koji, Update, General, Wednesday cleaning work
|
Fri Sep 20 12:55:02 2019, gautam, Update, CDS, c1iscaux testing
|
Mon Sep 23 10:49:34 2019, rana, Update, CDS, c1iscaux testing
|
Wed Sep 25 20:10:13 2019, Koji, Update, CDS, c1iscaux testing 
|
Thu Sep 26 20:09:40 2019, Koji, Update, CDS, c1iscaux testing    
|
Fri Sep 27 15:59:53 2019, gautam, Update, CDS, c1iscaux testing
|
Wed Oct 2 01:11:40 2019, Koji, Update, CDS, c1iscaux testing 8x
|
Fri Oct 4 01:57:09 2019, Koji, Update, CDS, c1iscaux testing   
|
Sat Oct 5 00:03:21 2019, Koji, Update, CDS, c1iscaux testing   
|
Tue Oct 8 03:32:42 2019, Koji, Update, CDS, CM servo board testing 7x
|
Tue Oct 8 17:59:29 2019, Koji, Update, CDS, CM servo board testing (portal) 6x
|
Tue Oct 8 18:42:39 2019, Koji, Update, CDS, CM servo board testing
|
Mon Oct 14 16:06:28 2019, Koji, Update, CDS, CM servo board testing
|
Mon Oct 14 16:19:30 2019, Koji, Update, CDS, CM servo board testing
|
Mon Oct 14 16:25:03 2019, Koji, Update, CDS, CM servo board testing
|
Mon Oct 14 16:34:42 2019, Koji, Update, CDS, CM servo board testing  
|
Mon Oct 14 17:32:28 2019, Koji, Update, CDS, Portal Elog entry for the recent CM servo board tests
|
Tue Oct 8 20:23:03 2019, gautam, Update, CDS, c1iscaux testing
|
Mon Sep 30 11:20:43 2019, gautam, Update, CDS, c1iscaux testing - CM board code updated
|
Mon Sep 30 15:51:59 2019, gautam, Update, CDS, c1iscaux - some admin
|
Thu Oct 10 22:11:53 2019, gautam, Update, LSC, Trans QPD checkout 
|
Mon Oct 7 14:51:20 2019, aaron, Update, Electronics, WFS head RF measurements
|
Mon Oct 7 19:50:33 2019, gautam, Update, IOO, IMC locking not working after this work 
|
Tue Oct 8 10:29:19 2019, gautam, Update, IOO, MC Transmission scan  
|
Tue Oct 8 16:54:56 2019, rana, Update, IOO, IMC locking not working after this work
|
Tue Oct 8 16:00:06 2019, aaron, Update, Electronics, WFS head RF measurements 
|
Wed Oct 9 12:15:05 2019, rana, Update, Electronics, WFS head RF measurements
|
Tue Sep 10 15:41:37 2019, aaron, Update, IOO, WFS measurements 
|
Wed Sep 11 10:26:56 2019, aaron, Update, IOO, WFS measurements
|
Wed Sep 11 14:37:43 2019, aaron, Update, IOO, WFS measurements 
|
Thu Sep 12 12:42:31 2019, aaron, Update, IOO, WFS measurements 
|
Fri Sep 13 10:36:03 2019, aaron, Update, IOO, WFS measurements 
|
Mon Sep 16 12:38:59 2019, aaron, Update, IOO, WFS measurements
|
Thu Oct 3 11:38:35 2019, aaron, Update, IOO, WFS measurements
|
Mon Sep 30 13:20:55 2019, aaron, Update, IOO, shot noise measurement
|
Fri Sep 13 10:53:40 2019, aaron, Update, IOO, WFS loop measurements
|
Mon Sep 16 05:08:04 2019, rana, Update, IOO, WFS loop measurements 
|
Mon Sep 16 11:55:58 2019, rika, Update, IOO, WFS loop measurements
|
Tue Sep 17 09:41:48 2019, gautam, Update, IOO, WFS loop measurements
|
Tue Sep 17 10:47:44 2019, rika, Update, IOO, WFS loop measurements
|
Wed Sep 18 14:45:52 2019, rika, Update, IOO, WFS loop measurements
|
Tue Sep 17 10:34:48 2019, aaron, Update, IOO, WFS loop measurements
|
Tue Oct 8 20:39:42 2019, aaron, Update, IOO, WFS loop measurements
|
Wed Oct 9 09:37:28 2019, aaron, Update, IOO, WFS loop measurements
|
Fri Oct 4 22:22:03 2019, gautam, Update, CDS, Final incarnation of latch.py
|
Tue Oct 8 03:19:14 2019, Koji, Update, CDS, Final incarnation of latch.py
|
Fri Oct 4 00:32:24 2019, gautam, Update, ALS, More locking updates 
|
Sat Oct 5 21:26:34 2019, gautam, Update, ALS, Y-end green alignment tweaked 
|
Sun Oct 6 15:23:27 2019, gautam, Update, ALS, Arm control using error signals achieved  
|
Thu Oct 3 12:08:47 2019, gautam, Update, General, Make the Jenne-laser setup fiber-coupled 
|
Thu Oct 3 14:32:37 2019, rana, Update, General, Make the Jenne-laser setup fiber-coupled
|
Thu Oct 3 14:54:33 2019, Koji, Update, General, Make the Jenne-laser setup fiber-coupled
|
Thu Oct 3 21:05:04 2019, aaron, Update, General, Make the Jenne-laser setup fiber-coupled
|
Thu Oct 3 23:15:39 2019, Koji, Update, General, Make the Jenne-laser setup fiber-coupled
|
Fri Oct 4 00:30:31 2019, gautam, Update, General, Make the Jenne-laser setup fiber-coupled
|
Fri Oct 4 14:25:59 2019, aaron, Update, General, Make the Jenne-laser setup fiber-coupled  
|
Thu Oct 3 19:40:18 2019, gautam, Update, LSC, POX/POY imbalance
|
Wed Oct 2 23:15:02 2019, gautam, Update, LSC, FPMI locking
|
Thu Oct 3 11:01:18 2019, rana, Update, LSC, (PR)FPMI locking
|
Mon Apr 8 11:53:17 2019, gautam, Update, CDS, c1oaf needs debugging 
|
Wed Oct 2 23:23:02 2019, gautam, Update, CDS, c1oaf DC indicator needs to be green
|
Tue Oct 1 21:19:51 2019, gautam, Update, LSC, PRMI locked on carrier
|
Wed Oct 2 11:52:16 2019, gautam, Update, LSC, PRMI Oplev loop checkout
|
Wed Oct 2 10:50:20 2019, gautam, Update, CDS, Anaconda updated
|
Wed Oct 2 10:40:07 2019, gautam, Update, CDS, c1oaf model restarted
|
Tue Oct 1 18:35:12 2019, gautam, Update, General, Beam centering campaign
|
Mon Sep 30 18:20:26 2019, gautam, Update, ALS, ALS OOL noise - a first look
|
Sun Sep 29 15:58:19 2019, gautam, Update, LSC, POX locking attempt
|
Mon Sep 30 14:16:43 2019, gautam, Update, LSC, POX PD checkout - solved
|
Fri Sep 20 11:39:04 2019, gautam, Update, Optical Levers, ETMX Oplev HeNe Dead
|
Sun Sep 29 16:08:25 2019, gautam, Update, Optical Levers, ETMX Oplev HeNe replaced
|
Thu Sep 26 17:56:28 2019, Koji, Update, CDS, some rebooting
|
Fri Sep 20 18:28:34 2019, gautam, Update, LSC, Y arm locking attempt
|
Wed Sep 18 12:40:09 2019, gautam, Update, CDS, Fast BIO Mapping at 1Y2
|
Thu Sep 19 21:23:51 2019, gautam, Update, CDS, Fast BIO splicing re-implemented at 1Y2  
|
Thu Sep 5 18:42:19 2019, aaron, HowTo, CDS, WFS discussion, restarting CDS
|
Thu Sep 5 20:30:43 2019, rana, HowTo, CDS, WFS discussion, restarting CDS
|
Fri Sep 6 09:40:56 2019, aaron, HowTo, CDS, WFS discussion, restarting CDS
|
Fri Sep 6 11:56:44 2019, aaron, HowTo, CDS, WFS discussion, restarting CDS
|
Fri Sep 6 15:12:49 2019, Koji, HowTo, CDS, WFS discussion, restarting CDS
|
Fri Sep 6 21:22:06 2019, Koji, HowTo, CDS, How to save c1ioo
|
Fri Sep 6 22:03:30 2019, aaron, HowTo, CDS, How to save c1ioo
|
Mon Sep 9 11:36:48 2019, aaron, HowTo, CDS, How to save c1ioo
|
Thu Sep 19 15:59:29 2019, aaron, HowTo, CDS, How to save c1ioo
|
Wed Sep 18 15:27:45 2019, gautam, Update, IOO, TT cables need to be remade
|
Thu Sep 19 09:39:30 2019, gautam, Update, IOO, TT cables need to be remade
|
Thu Sep 19 11:26:18 2019, gautam, Update, IOO, TT cables DON'T need to be remade
|
Tue Sep 17 23:46:21 2019, Koji, Update, CDS, Latch Enable Logic
|
Tue Sep 17 23:43:34 2019, Koji, Summary, CDS, Acromag logic checker 
|
Tue Sep 17 14:01:46 2019, gautam, Update, CDS, daqd fw dead
|
Tue Sep 17 21:34:07 2019, gautam, Update, CDS, daqd fw dead no more
|
Tue Jul 16 15:17:57 2019, Koji, HowTo, CDS, Final bit bug of the BIO CDS module
|
Tue Sep 17 14:43:59 2019, gautam, HowTo, CDS, Final bit bug of the BIO CDS module
|
Fri Sep 13 13:03:35 2019, Koji, Summary, CDS, DIN 96pin to DSUB37 adapter (single) ready for use
|
Mon Sep 16 09:11:37 2019, gautam, Summary, CDS, DIN 96pin to DSUB37 adapter (single) ready for use
|
Mon Sep 16 20:22:19 2019, gautam, Summary, CDS, Update on the Acromag status
|
Mon Sep 16 17:53:16 2019, aaron, Update, Cameras, MC2 trans camera (?) rotated
|
Mon Sep 16 19:29:24 2019, Koji, Update, Cameras, MC2 trans camera (?) rotated
|
Mon Sep 16 12:00:16 2019, aaron, HowTo, General, Moved some immovable optics
|
Tue Sep 10 17:26:49 2019, Koji, Update, CDS, D1900068 SR785 accessory box
|
Tue Sep 10 16:10:40 2019, Chub, Update, , Rack Update 
|
Tue Jul 16 16:00:01 2019, gautam, Update, CDS, c1iscaux Supermicro setup
|
Wed Jul 17 21:22:41 2019, gautam, Update, CDS, CM board Latch Enable subtlety
|
Sun Jul 21 12:55:38 2019, gautam, Update, CDS, CM board Latch Enable test script 
|
Fri Aug 9 08:59:04 2019, gautam, Update, CDS, Prep for install of c1iscaux
|
Sun Aug 11 11:47:42 2019, gautam, Update, CDS, Bench test of c1iscaux
|
Mon Aug 12 17:36:04 2019, gautam, Update, CDS, More bench test of c1iscaux
|
Mon Aug 12 21:25:19 2019, Koji, Update, CDS, More bench test of c1iscaux
|
Tue Aug 13 08:07:09 2019, gautam, Update, CDS, P1--->P2
|
Tue Aug 13 14:36:17 2019, gautam, Update, CDS, P1--->P2
|
Fri Aug 16 16:40:04 2019, gautam, Update, CDS, 1Y3 work  
|
Sat Aug 17 16:49:23 2019, gautam, Update, CDS, More 1Y3 work   
|
Mon Aug 19 14:36:21 2019, gautam, Update, CDS, c1iscaux remaining work
|
Tue Aug 20 19:05:24 2019, Koji, Update, CDS, MC1 (and MC3) troubleshoot 
|
Thu Aug 22 12:54:06 2019, Koji, Update, CDS, MC1 glitch removed (for now) and IMC locking recovered 7x
|
Thu Aug 22 20:56:51 2019, Koji, Update, CDS, MC1 glitch removed (for now) and IMC locking recovered
|
Fri Aug 23 18:46:17 2019, Jon, Update, CDS, c1iscaux remaining work
|
Sun Aug 25 14:18:08 2019, gautam, Update, CDS, c1iscaux remaining work
|
Thu Jul 18 10:46:04 2019, gautam, Update, CDS, Database files made
|
Thu Jul 18 19:58:56 2019, gautam, Update, CDS, Work on Acromag chassis  
|
Fri Jul 19 19:44:03 2019, gautam, Update, CDS, Database file test
|
Fri Aug 23 19:10:02 2019, Jon, Update, Cameras, GigE camera server is online
|
Tue Jun 4 00:17:15 2019, gautam, Update, BHD, Preliminary BHD calculations
|
Thu Jun 6 18:49:22 2019, gautam, Update, BHD, Preliminary BHD calculations  
|
Wed Jul 3 11:47:36 2019, gautam, Update, BHD, PRC filtering
|
Wed Jul 31 09:41:12 2019, gautam, Update, BHD, OMC cavity geometry
|
Wed Jul 31 17:57:35 2019, Koji, Update, BHD, OMC cavity geometry
|
Fri Aug 23 10:01:14 2019, gautam, Update, BHD, OMC cavity geometry - some more modeling 
|
Tue Aug 6 15:52:06 2019, gautam, Update, BHD, Preliminary BHD calculations
|
Thu Aug 15 18:54:54 2019, gautam, Update, ALS, ALS sensing noise due to IMC
|
Fri Aug 16 04:24:03 2019, rana, Update, ALS, ALS sensing noise due to IMC
|
Thu Aug 8 12:01:12 2019, gautam, Update, IOO, MC1 suspension oddness 
|
Mon Aug 12 19:58:23 2019, gautam, Update, IOO, MC1 suspension oddness
|
Fri Aug 9 20:58:33 2019, Jon, Update, Electronics, Borrowed Variac transformer
|
Fri Aug 2 11:37:38 2019, gautam, Update, ALS, EY IR ALS Assay 
|
Tue Aug 6 23:09:20 2019, gautam, Update, ALS, EY table work
|
Fri Aug 9 16:37:39 2019, gautam, Update, ALS, More EY table work 
|
Mon Aug 5 17:36:04 2019, yehonathan, Update, Loss Measurement,
|
Tue Aug 6 16:44:50 2019, yehonathan, Update, Loss Measurement, 
|
Fri Jul 19 17:42:58 2019, gautam, Update, General, rossa Xdisp bricked
|
Sat Jul 20 11:24:04 2019, gautam, Update, General, rossa bricked
|
Sun Jul 21 22:16:34 2019, rana, Update, General, rossa Xdisp bricked
| | |