  11426   Sat Jul 18 14:55:33 2015 jamieUpdateGeneralall front ends back up and runningAfter some surgery yesterday the front
ends are all back up and running:


Eric found that one of
 cds-good.png 
  11428   Sat Jul 18 16:03:00 2015 jamieUpdateCDSEPICS freezes persistI notice that the periodic EPICS freezes
persist.  They last for 5-10 seconds. 
MEDM completely freezes up, but then it comes
  
  11429   Sat Jul 18 16:59:01 2015 jamieUpdateCDSunloaded, turned off loading of, symmetricom kernel module on fbfb has been loading a 'symmetricom'
kernel module, presumably because it was
once being used to help with timing. 
  
  11430   Mon Jul 20 11:57:17 2015 ericqUpdateGeneralArm Locking recoveredThe interferometer is warming up!

I had some issues locking the IMC
at first. It turned out that the MC3 side
  
  11432   Tue Jul 21 05:17:09 2015 IgnacioUpdateGeneralMore clear accelerometer huddle tests resultsI generated the following plots from the
two sets of huddle test data we have for
the accelerometers. 
 new_data.pngnew_data.pngold_data_1.pngold_data_1.pngold_data_2.png 
  11433   Tue Jul 21 21:25:18 2015 Max IsiUpdateGeneral40m LDAS accountA shared LIGO Data Grid (LDG) account was
created for use by the 40m lab. The purpose
of this account is to provide access to the
  
  11434   Tue Jul 21 21:33:22 2015 Max IsiUpdateGeneralSummary pages moved to 40m LDAS accountThe summary pages are now generated from
the new 40m
LDAS account. The nodus URL (https://nodus.ligo.caltech.edu:30889/detcharsummary/)
  
  11435   Wed Jul 22 14:10:04 2015 ericqUpdateCDSRCG DiagnosticsNow that we've seemed to landed on
a working configuration, I've re-ran
the tests first described in ELOG
 filterShapes.pngCDS_diag_codes.zip 
  11436   Wed Jul 22 15:09:40 2015 ericqUpdateGeneralIMC workThe other night, I spent some time with
the mode cleaner. 

First, I made some model changes
  
  11438   Thu Jul 23 03:09:05 2015 ericqUpdateLSCaLIGO demod board lives!I'm a little mystified. Peeking inside
the aLIGO demod board, I saw that the reason
that two of the channels weren't working
 beatbox_vs_aLIGO.png 
  11439   Thu Jul 23 15:41:41 2015 SteveUpdatePEMfitting ants with TERROPasadena got 0.2" of  rain on
Saturday. Temperatures were high with high
humidity since than.The ants were back in
  
  11440   Thu Jul 23 20:54:42 2015 JessicaUpdateGeneralALS Delay Line BoxThe front panels for the ALS delay   
  11442   Thu Jul 23 21:12:14 2015 IgnacioUpdateGeneralNewer accelerometer huddle test data + detrendingIn the last post concerning the self noise
of the accelerometers, I mentioned the differences
between the two data sets I was playing with.
 old_data_1.pngold_data_2.pngnew_data.pngsix_old_data.png 
  11443   Fri Jul 24 13:49:09 2015 SteveUpdatesafetyLock doors please !Thursday morning I found the control room
emergency exit not locked.

Please check the doors when leaving
  
  11444   Fri Jul 24 18:12:52 2015 Max IsiUpdateGeneralData missingFor the past couple of days, the summary
pages have shown minute trend data disappear
at 12:00 UTC (05:00 AM local time). This
 C1-ALL_FBDB3F_TIMESERIES-1121731217-86400.png 
  11445   Fri Jul 24 20:32:15 2015 ericqUpdateElectronicsLSC LO distribution box power button replaced As happened with the RF distribution box
in the IOO rack a while back, the shiny blue
power button in the LSC LO distribution box
 2015-07-24_15.43.56.jpg2015-07-24_16.57.19.jpg 
  11446   Fri Jul 24 23:08:53 2015 IgnacioUpdatePEMMC1 accelerators moved for future huddle testI have moved the MC1 accelerators and cable
to the huddle test set up, in order to see
how a six witness huddle test with the improved
 image1.JPG 
  11447   Mon Jul 27 16:47:53 2015 ericqUpdateIOOMC2 -> MCL Actuator TFOur noise cancellation SURFS will be doing
online subtraction on the mode cleaner length,
among other things. 
 mc2_2_mcl.pngMC2_2_MCL_TF.txt.zip 
  11448   Mon Jul 27 17:51:06 2015 EveUpdateSummary PagesNew summary page tabs and other improvementsThe summary pages can still be found at https://nodus.ligo.caltech.edu:30889/detcharsummary/ (EDIT:
in an older version of this post I listed
  
  11449   Tue Jul 28 05:00:03 2015 IgnacioUpdateGeneralSeismometer cansI've have been talking a little   
  11450   Tue Jul 28 09:31:35 2015 IgnacioUpdateGeneralNewest accelerometer huddle testI downloaded new accelerometer huddle test
data from last night and analyzed it. This
new data set is ~55 mins and uses the same
 selfnoise_allsix_miso_newest.png 
  11451   Tue Jul 28 14:58:59 2015 SteveUpdateGeneraldo not place anything on optical table topsSpecially heavy
items: old analoge scope or hardware loaded
 tabletops!.jpgtabletops!!.jpg 
  11452   Tue Jul 28 15:05:09 2015 SteveUpdatesafetyfire alarm test ? noWe just had fire alarm trigged avacuation
of the 40m lab.

It turned out that the CES building
 6minGaps.png 
  11453   Tue Jul 28 15:06:27 2015 SteveUpdateIOOPSL HEPA turned on   noHepa.jpg 
  11454   Tue Jul 28 16:42:25 2015 SteveUpdateGeneralJamies entry was deletedSorry Jamie, I accidentally deleted your
elog entry #11453
  
  11455   Tue Jul 28 17:07:45 2015 JamieUpdateGeneralData missing


  
  11459   Wed Jul 29 14:32:01 2015 SteveUpdateGeneralHow not to solder 




 coldSoldering.jpg 
  11460   Wed Jul 29 17:51:56 2015 IgnacioUpdatePEMAccelerators moved back to MC1 and MC2We are done taking accelerator huddle test
data. So I moved back all six accelerometers
and cables to MC1 and MC2. I also relabel
 FullSizeRender.jpgFullSizeRender_2.jpg 
  11462   Thu Jul 30 02:06:20 2015 IgnacioUpdateIOOMC2 <-> MCL Actuator TF fittedEric downloaded MC2 to MCL transfer function
data (H) as well as its inverse, MCL to MC2
(Hinv). He also downloaded new MCL and MC2
 TF_BODE.pngMC2_2_MCL.pngTF_INV_BODE.pngMCL_2_MC2.png 
  11463   Thu Jul 30 03:19:24 2015 ericqUpdateLSCBack towards PRFPMI The refreshed ALS didn't look so bad
today (elog forthcoming), so I decided to
give PRFPMI locking a shot tonight. I was
  
  11464   Thu Jul 30 10:38:18 2015 SteveUpdatePEMY sesimostation is back onKoji soldered new 50" long cable for
the Y station.

 
 Guralps_are_back_on.pngYstation.jpg 
  11466   Thu Jul 30 13:34:52 2015 KojiUpdatePEMY sesimostation is back onPlease check the spectra. If something
is wrong, please swap the cables between
X and Y in order to see if the cable is still
  
  11467   Thu Jul 30 14:27:18 2015 EveUpdateSummary PagesALS, ASC, LSC Summary PagesI've switches the ALS, ASC, and LSC
plots on the summary pages from plotting
raw frames, to plotting minute trends, instead.
  
  11468   Thu Jul 30 14:42:03 2015 ericqUpdateLSCaLIGO demod board lives!ALS is not currently
limited by the demod board or whitening electronics.
 partialALSbudget.pngdemodDriveLevels.pngALScoherences.pngpartialALSbudget.zip 
  11469   Thu Jul 30 15:24:54 2015 SteveUpdatePEMY sesimostation is back onAtm1,  New short-50" long cable
was installed at ETMY end ( Y-station ) between
Guralp-B ( MIT ) and granite base.
 NewShortCable-Y-B-Gur2.pnginterfaceInputSwapped.pngsameasAtm2.png 
  11470   Thu Jul 30 15:58:00 2015 ericqUpdateLSCBeat note Alignment fluctuation effects measured



 RF_RIN.pngRF_RINspec.pngRFampCoh.xml.zip 
  11471   Thu Jul 30 18:58:36 2015 JessicaUpdateGeneralALS Delay Line Box Front Panel TestingI tested both of the front panels (conductive
and isolated SMAs) with the ALS Delay Line
Box by driving extremely close frequencies
 Xarm_diff.pngYarm_diff.pngXarm_isolated.pngYarm_isolated.png 
  11472   Thu Jul 30 19:12:52 2015 IgnacioUpdateIOOYAW and PIT WFS Wiener filteringRana pointed out that another way to mitigate
seismic motion at in the mode cleaner would
be to look at the YAW and PITCH output  channels
 YAW.pngPIT.png 
  11473   Fri Jul 31 10:36:22 2015 SteveUpdatePEMX seismo station short cable removed 




 IMG_0009.JPG 
  11474   Sat Aug 1 17:04:29 2015 EveUpdateSummary PagesStates and Triggers in SPsI've added states to the summary pages
to only show data for times at which one
certain channel is above a specified threshold.
  
  11475   Sat Aug 1 20:46:29 2015 KojiUpdatePEMX seismo station short cable removedOMG   
  11476   Mon Aug 3 08:16:19 2015 SteveUpdateSUSETMX damping restored   ETMXrestored.png 
  11477   Mon Aug 3 18:19:09 2015 JessicaUpdateGeneralAnodization of front panels accounted forPreviously, I had gotten the same results
for the conductive and the isolated front
panels. Today, I sanded off the anodized
 redo_conduct1X.pngredo_conduct1Y.png 
  11478   Tue Aug 4 03:02:30 2015 ericqUpdateLSCBeat note Alignment fluctuation effects measuredNotes from tonight's work:


PMC alignment tweaked.
Not much gained
WFS/MC2 offsets
 coherences.pnglinX.png 
  11479   Wed Aug 5 10:56:07 2015 ericqUpdateCDSMany models crashed Last night around 1AM, many of the the
frontend models crashed due to an ADC timeout.
(But none of the IOPs, and all the c1lsc
 crashes.png 
  11480   Wed Aug 5 17:15:08 2015 EveUpdateSummary PagesFixed ASC TabI've fixed the ASC
tab on the summary pages to populate
the graphs with data without causing an error.
  
  11481   Thu Aug 6 01:38:19 2015 ericqUpdateComputer Scripts / ProgramsChiara gets new Ethernet cardSince Chiara's onboard ethernet card
has a reputation to be flaky in Linux, Koji
suggested we could just buy a new ethernet
  
  11482   Thu Aug 6 04:36:41 2015 ericqUpdateASCReviving PRC angular feedforwardTonight, I've taken a bunch of data
where the PRC is carrier locked and the ITM
oplevs have the DC coupling FM turned on,
  
  11483   Thu Aug 6 09:16:57 2015 SteveUpdateVACChiara gets new Ethernet card
Yesterday we did put the vacuum
system into
 ChiaraNetCard.png23.png 
  11484   Thu Aug 6 11:45:01 2015 JessicaUpdateGeneralALS Delay Line front panel testingKoji had suggested that I sync up the two
function generators to ensure that they have
the same base frequency and so that crosstalk
 conductive_X.pngconductive_Y.pngisolated_X.pngisolated_Y.png 