40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 247 of 341  Not logged in ELOG logo
ID Date Author Type Categoryup Subject Text Attachments
  6356   Mon Mar 5 15:15:15 2012 DenUpdatePEMRCG[Alex / Den]
I've encountered a problem that C1:PEM-SEIS_GUR1_X_IN1
is saved in the int format. It turned out
  
  6372   Wed Mar 7 13:30:17 2012 JimUpdatePEMadded TPs and JIMS channels to PEM front-end model [Jim Ryan]
The PEM model has been modified now
to include a block called 'JIMS' for the
  
  6389   Fri Mar 9 10:17:06 2012 steveHowToPEMdo not leave tables openType: How not to
Please do not leave optical tables
open! You will be held responsible for creating
 P1080547.JPG 
  6427   Sun Mar 18 00:29:24 2012 DenUpdatePEMsts-2I've turned off the power of the STS-2
readout box as it provides outputs with ~10
Volts DC offset! AA filter box works in the
  
  6430   Tue Mar 20 16:53:48 2012 steveUpdatePEMcranes maintenance & certified inspection of 2012Fred Goodbar of Konecrane has completed
the annual certified crane inspection and
maintenance of our cranes as required in
  
  6468   Thu Mar 29 20:13:21 2012 jamieConfigurationPEMPEM_SLOW (i.e. seismic RMS) channels added to fb masterI've added the PEM_SLOW.ini file to the
fb master file, which should give us the
slow seismic RMS channels when the framebuilder
  
  6484   Wed Apr 4 13:25:29 2012 jamieConfigurationPEMPEM_SLOW (i.e. seismic RMS) channels aquiring

    

       
            
 2012-04-04-132346_1182x914_scrot.png 
  6499   Fri Apr 6 19:04:35 2012 JenneUpdatePEMSTS releveled, GUR2 plugged in[Den, Jenne]
We were wondering why the STS-2 signal
was funny.  When I went to look at it,
  
  6529   Thu Apr 12 20:56:07 2012 DenUpdatePEMdaqGUR1 XYZ, GUR2 XYZ, MC_F channels are now
recorded at 256 Hz.
  
  6536   Mon Apr 16 09:10:37 2012 DenUpdatePEMgur2_xAlready not for the first time I notice
that GUR2 readjusts its X zero position
 seisms.pnggur12_coh.jpg 
  6537   Mon Apr 16 09:44:54 2012 JenneUpdatePEMgur2_x

    

       
            
  
  6538   Mon Apr 16 14:37:01 2012 DenUpdatePEMgur2_x

    

       
            
  
  6557   Mon Apr 23 23:20:07 2012 DenUpdatePEMmicrophonesTonight I wanted to measure the ambient
noise level using Blue Bird mics and figure
out if Panasonic WM61a or Primo EM172/173
  
  6558   Tue Apr 24 09:58:37 2012 steveUpdatePEMearthquake 3.9 magnitudeLocal
eq shakes the lab
 eq3.9.png 
  6559   Tue Apr 24 11:27:51 2012 steveUpdatePEMnew chairsWe received 6 new
 chairs stools
 P4241026.JPG 
  6563   Tue Apr 24 16:15:24 2012 DenUpdatePEMmicrophonesI've installed Blue Bird microphone to
listen to the acoustic noise at the PSL near
PMC.
 DSC_4271.JPGDSC_4272.JPGmicro_mc_low.pngmicro_mc_high.png 
  6564   Tue Apr 24 22:16:59 2012 DenUpdatePEMBlue Bird Pre-Amplifier I detached Clyde (pre-amp that was
in the control room) to understand why it
is not working. I seems that the board circuit
 DSC_4273.JPGDSC_4274.JPG 
  6565   Wed Apr 25 00:20:01 2012 DenUpdatePEMacoustic noise at 40m Blue
Bird Mic is suspended close to PMC now and
outputs ~10 counts when pre-amp gain is 8
  
  6566   Wed Apr 25 11:45:34 2012 JenneUpdatePEMBlue Bird Pre-AmplifierIt looks like we should change the "R40"
and "R47" diodes.  If you
do it this week, ask Jamie or Koji to check
  
  6567   Wed Apr 25 18:59:47 2012 ranaUpdatePEMBlue Bird Pre-AmplifierUsually R is for resistors and D is for
diodes. Do you think from the schematic that
we should put diodes into the R slots? 
  
  6568   Wed Apr 25 19:32:57 2012 DenUpdatePEMBlue Bird Pre-Amplifier

    

       
            
  
  6572   Thu Apr 26 11:56:10 2012 DenUpdatePEMBlue Bird Pre-Amplifier

    

       
            
  
  6581   Fri Apr 27 13:32:06 2012 DenUpdatePEMseism channelsA few weeks ago I found that GUR2_X signal
is biased from 0 to 800 counts in average.
I decided that the corresponding channel
 pem.png 
  6593   Wed May 2 19:47:20 2012 DenUpdatePEMEM 172 nonlinearitiesI've checked new small EM172 microphones
for nonlinearities using Koji's Mac Book
speakers. EM172 + Mac nonlinearities are
 500Hz_noise.png 
  6594   Wed May 2 21:04:06 2012 DenUpdatePEMEM 172 coherenceI measured coherence between 2 EM 172 microphones
in a "quiet room" with SR785
 em_coh.png 
  6610   Sun May 6 01:41:55 2012 DenUpdatePEMseismic in x,y armsI locked x,y arms and measured coherence
between POS{X,Y}11_I_ERR, MC_F and seismometer
signals.
 coh_xyf.png 
  6651   Sun May 20 19:57:51 2012 DenUpdatePEMmicrophonesI've soldered EM172 microphones to BNC
connectors to get data from them.
 7x 
  6664   Tue May 22 23:36:02 2012 DenUpdatePEMmircophonesI've put 5 EM172 microphones close together
and measured there signal and coherence.
They are plugged in to accelerometer channels.
 6x 
  6666   Wed May 23 11:30:39 2012 steveUpdatePEMnew emergency back up lights installedNew self checking emergency back
up lights were installed at 13 locations
in the 40m lab.
 IMG_1217.JPG 
  6671   Thu May 24 02:55:36 2012 DenUpdatePEMacoustic noise in MCLMic in the PSL showed that fluctuations
in the MCL in the frequency range 10 - 100
Hz are due to acoustic noise. I've measured
 audio_noise.png 
  6674   Thu May 24 13:28:38 2012 DenUpdatePEMHEPAHEPA filter was running at 90% of max.
I reduced it to 20%. Acoustic noise moved
down
 psl_acoustic.pngmcl_90.pngmcl_20.png 
  6692   Sat May 26 20:40:48 2012 DenUpdatePEMexperiments with seismic noiseI measured relative motion of 2 seismometers
separated by 4, 18 and 38 feet.
 DSC_4307.JPGDSC_4308.JPGsim_delta.pngratio.pngpsd_distance.png 
  6693   Sat May 26 23:57:11 2012 DenUpdatePEMGuralp noiseI've looked through the Guralp manual to
figure out what noise do they declare. They
present it in acceleration units in dB relative
 noises.png 
  6695   Sun May 27 23:15:22 2012 DenUpdatePEMexperiments with seismometersI wondered if linoleum is a reason of high
Guralp noise. I measured Guralp noise in
3 cases: they stand on a very soft piece
 DSC_4309.JPGDSC_4310.JPGDSC_4311.JPGloc_noise.png 
  6696   Tue May 29 00:35:57 2012 DenUpdatePEMguralp readout boxI measured the frequency response of the
Guralp readout box and noise by providing
sin signal of amplitude 50 mV at 15 Hz for
 1_3.png 
  6697   Tue May 29 00:39:52 2012 DenUpdatePEMGuralp noiseI've connected Guralp output to the ADC
without readout box. I've got the same noise
at low frequencies and even worse noise at
 in_out.png 
  6698   Tue May 29 00:48:51 2012 DenUpdatePEMsts readout boxSTS readout box seems to be partly broken.
I've terminated inputs from the seismometer
and measured the output. I could not do this
 sts_box.png 
  6712   Tue May 29 22:48:37 2012 DenUpdatePEMGuralp noiseI've checked whether the Guralp noise that
we see comes not from seismometer but from
ADC or readout box. I did 2 separate measurements
 split_noises.png 
  6721   Wed May 30 22:51:32 2012 DenUpdatePEMguralp isolation boxWhen I've put Guralps inside the isolation
box, the signal from seismometers increased
and was out of AA board range. I've reduced
 lin_box_noise.png 
  6730   Thu May 31 11:38:19 2012 DenUpdatePEMisolation systemI've put Guralps into the Steve's 2 box
isolation system. Noise got better, coherence
between 2 seismometers improved. We still
 lin_box_noise2.pnglin_box_coh.png 
  6747   Sun Jun 3 01:30:07 2012 DenUpdatePEMsts-2 and guralp in isolation boxWe have 2 sts-2 readout box - pink and
blue. Pink outputs 12 DVC - this a problem
of amplifier. This box has a rectifier (the
 DSC_4315.JPGDSC_4319.JPGlin_box_noise.pngmcl_gur.png 
  6754   Tue Jun 5 14:17:14 2012 steveUpdatePEMair cond maintenance  
 Air conditioning maintenance
is scheduled for tomorrow from 8 to 11am
  
  6782   Thu Jun 7 09:52:05 2012 steveUpdatePEMair cond maintenance

    

       
            
 PEM800d.png 
  6845   Thu Jun 21 09:10:08 2012 steveUpdatePEMflow bench must be running all timesThe south end flow bench HEPA filter should
be run all times. You can turn it off for
a measurement or two but remember we are
  
  6846   Thu Jun 21 12:13:35 2012 JenneUpdatePEMflow bench must be running all times

    

       
            
  
  6869   Mon Jun 25 15:19:07 2012 YaakovUpdatePEMAdded microphone channels, moved accelorometer channelsJenne and I renamed the mic channels Den
created (elog
6664) to MIC_1, MIC_2, etc from the original
 channels.png 
  6932   Fri Jul 6 20:54:54 2012 MashaUpdatePEMCurrent PEM statusHi everybody,
Last night I (with the help of Jenne
and  Jenne's advice - not to implicate her
  
  6933   Fri Jul 6 22:30:14 2012 MashaUpdatePEMCurrent PEM status

    

       
            
 MashaDV.png 
  6934   Sat Jul 7 15:48:00 2012 MashaUpdatePEMCurrent PEM status

    

       
            
  
  6935   Sat Jul 7 16:34:41 2012 MashaUpdatePEMPEM no longer freaking out (as much). Hi everybody,
Sorry for flooding the ELOG about
the PEM channels. Today I
 Masha.png 
ELOG V3.1.3-