  7301   Tue Aug 28 18:28:21 2012 janoschMetaphysicsRingdownripples Let's see if the ripples observed
in the MC ringdown can be due to tilt
motion of the mirrors.
  
  7303   Tue Aug 28 19:21:37 2012 janoschMetaphysicsRingdownripples Hmm. I don't know what ringing really
is. Ok, let's assume it has to
do with the pump... I don't see how
  
  7305   Wed Aug 29 09:35:03 2012 janoschMetaphysicsRingdownripples 2Ok, so the whole idea that mirror motion
can explain the ripples is nonsense. At least,
when you think off the ringdown with
  
  7356   Fri Sep 7 00:08:10 2012 janoschMetaphysics baffle clipping lossWith a curvature radius of about 57m
for the ETMs, flat ITMs at the beam waist,
and using 39m for the arm lengths, one finds
  
  7480   Thu Oct 4 18:48:04 2012 janoschConfigurationPSLAOM installation
  
  7527   Thu Oct 11 11:20:05 2012 janoschUpdateGeneralbeam shape simulation, PRCI started to create a Finesse model of
the PRC cavity. We have the phase maps for
the PRC and the two ITMs. I could not find
  
  7533   Thu Oct 11 21:26:40 2012 janoschUpdateGeneralPRC phase mapsJust some plots. There is nothing new here
except for the fact that I learned how to analyze
phase maps myself and how to prepare them
 7x 
  7615   Wed Oct 24 22:48:46 2012 janoschUpdateComputer Scripts / ProgramsPhase map summary of LaserOptik mirrors
  
  7627   Thu Oct 25 22:52:07 2012 janoschUpdateGeneraltip-tilt phase mapsNow that I read Koji's last elog about
phase maps, I am not sure if these are still
required, but here they are (the tilt-removed
 6x 
  7629   Thu Oct 25 23:14:42 2012 janoschUpdateGeneraltip-tilt phase maps
  
  7639   Mon Oct 29 14:57:41 2012 janoschUpdateGeneraltip-tilt phase maps
  
  7734   Tue Nov 20 16:03:37 2012 janoschUpdatePEMSeismometers and a microphone
  
  7319   Thu Aug 30 17:03:32 2012 janosch, Manasa, SteveUpdate ETMXThe baffle has been moved away from ETMX
towards the edge of the table (in fact, it
is a little beyond the edge). It is also
  
  7352   Thu Sep 6 17:11:40 2012 janosch, Manasa, SteveUpdate pick-off and baffle at ETMYWe have installed the pick-off mirror at
the ETMY table for the small-angle
scattering measurement on ITMY. As we
  
  7317   Thu Aug 30 12:01:27 2012 janosch, Manasa,SteveUpdate ETMXWe have done some work at ETMX today. We
installed the baffle and placed two
mirrors on the table.
  
  7326   Fri Aug 31 10:16:02 2012 janosch, SteveUpdate ETMX, scattering prepsThe alignment of the pick-off mirror near
ETMX is done. Everything turned out to be
easy once we realized that there is no sense getting
 IMG_1609.JPGIMG_1608b.jpg 
  1170   Wed Dec 3 12:49:11 2008 jenneUpdateComputerssomething sketchy with NDS ... or something[SIZE=2][COLOR=green]Never mind...I had forgotten
that you have to run mdv_config every time
you open matlab, not just every time you
  
  1890   Wed Aug 12 10:35:17 2009 jenneSummaryComputersNodus rebooted / SVN down


   
        
            
  
  2069   Thu Oct 8 14:41:46 2009 jenneUpdateComputersc1susvme1 is back online

    
        
  
  2119   Mon Oct 19 17:12:54 2009 jenneUpdatePEMaccelerometers and seismomters are all good.

    
        
 SeismometersGoodSpectra_19Oct2009.png 
  2440   Mon Dec 21 10:09:06 2009 jenneUpdateASSOAF Model update and build instructionsOAF stands for Online Adaptive Filtering.
 We use the same computer which was once
the ASS. One of these days, we'd like to
  
  2685   Fri Mar 19 18:00:14 2010 jenneUpdatePEMGuralp2 centered again[Jenne, Sanjit]
It looks like Steve used a GND-12V
supply to power the Guralp through the little
  
  6750   Mon Jun 4 23:48:43 2012 jenneUpdateGreen Lockinglowered gainWe're trying to do a yarm measurement....before
I forget, I want to write this down...
I changed the gain of each of the
  
  10812   Wed Dec 17 19:04:12 2014 jenneUpdateASCASS retunedI made the Xarm follow the new (old) topology
of Length -> test masses, and Trans ->
input pointing.
  
  7463   Tue Oct 2 15:14:54 2012 jenne, jamieUpdateIOOPZT diagnosispzt2 mod signals matched slider vals for
both pitch and yaw

  pzt2 yaw mon output = 6
 
  
  7673   Tue Nov 6 16:38:37 2012 jenne, jamie, ayaka, manasaUpdateAlignmentAlignment back under control againWe had a big alignment party early this
morning, and things are back to looking good. 
We have been very careful not to bump or
  
  3916   Sun Nov 14 16:26:31 2010 jenne, valeraUpdateElectronicsSRM side OSEM noise with no magnetWe realized that the SRM sensors are connected
to the readout but just sitting on the BS
in vacuum table with no magnets and therefore
 SRM-SD-Current-NoMagnet.pdf 
  12998   Thu May 18 15:20:29 2017 jigyasaSummarytelescope designTelescope Design for the Gig-E camerasWith the objective of designing a telescope
system for the Gig-E, a system of two lenses
is implemented. A rough schematic of
 6x 
  13000   Mon May 22 10:15:14 2017 jigyasaSummarytelescope designLens tubes and object distancesSince the
f numbers of the lenses in the proposed design
with biconvex lenses are a little less than
 Pictures1.pdf 
  13004   Mon May 22 15:01:41 2017 jigyasaUpdatetelescope designUpdated Telescope design with 1'' eye pieceI examined
the use of a single lens system for the available
range of focal lengths, for the required
 1incep.pdf 
  13013   Thu May 25 16:42:41 2017 jigyasaUpdateComputer Scripts / ProgramsMaking pylon installation on shared directoryI have been working on interfacing with
the GigE’s. I went through Joe Be’s
paper and the previous elogs and verified
  
  13014   Thu May 25 18:37:11 2017 jigyasaUpdateComputer Scripts / ProgramsMaking pylon installation on shared directoryGautam helped me execute the commands mentioned
above and Pylon has now been installed
on the shared directory. We extracted the
  
  13020   Tue May 30 17:45:35 2017 jigyasaSummaryCamerasGigE configuration To verify the Pylon Installation on the
shared drive, I tried connecting the Basler
acA640-100gm to the PoE connector and running
 GigEconfiguration.pdf 
  13023   Wed May 31 14:23:42 2017 jigyasaUpdateComputer Scripts / ProgramsEstablishing the EPICs channels for the GigETo set up the EPICs channels for the GigE,
Gautam and I followed the steps in the elog
by him  8957
  
  13024   Wed May 31 18:17:28 2017 jigyasaSummaryCamerasGigE configuration This evening I was able to obtain some
images with the same lens on the GigE. 
The problem earlier, as Johannes pointed
 PictureswithPylon.pdf 
  13025   Wed May 31 19:18:53 2017 jigyasaSummaryCamerasGigE configuration And here's another picture of Kaustubh,
my fellow SURF, captured in all his glory
by Rana! :)
 Image__2017-05-31__18-49-37.bmp 
  13027   Thu Jun 1 15:33:39 2017 jigyasaUpdateCamerasGigE installation in the IFO areaI tried to
capture some images with the GigE inside
the Interferometer area in the 40m today.
 HOMMC2.pdf 
  13029   Thu Jun 1 16:14:55 2017 jigyasaUpdateCamerasGigE installation in the IFO areaThanks to Steve and Gautam, the IMC was
locked.

I was able to capture images with
 MC2.pdf 
  13040   Mon Jun 5 12:27:34 2017 jigyasaUpdateCamerasAttempt to run camera server Python codeWhile attempting
to execute the Python/Pylon code for the
camera server, camera_server.py, the compiler
  
  13041   Mon Jun 5 12:50:42 2017 jigyasaUpdateCamerasAttempt to run camera server Python codeI think there
might be a problem with the fact that
the installation of the various components
  
  13043   Mon Jun 5 18:40:12 2017 jigyasaUpdateCamerasAttempt to run camera server Python code[Gautam, Jigyasa]

This
evening, Gautam helped me resolve the
  
  13056   Fri Jun 9 16:37:29 2017 jigyasaUpdateComputer Scripts / ProgramsOpenCV installationOpenCV 3.1.0
has been installed by following the commands
locally on Donatella
  
  13066   Thu Jun 15 18:56:31 2017 jigyasaUpdateComputer Scripts / ProgramsMC2 Pitch-Yaw offsetA python
script to randomly vary the
MC2 pitch and yaw offset and correspondingly
  
  13070   Fri Jun 16 18:21:40 2017 jigyasaConfigurationCamerasGigE camera IP One of the additional GigE cameras has been
IP configured for use and installation. 

Static IP assigned to the camera-
  
  13072   Mon Jun 19 18:32:18 2017 jigyasaUpdateComputer Scripts / ProgramsSoftware Installation for image analysisThe IRAF software from the National Optical
Astronomy Observatory has been installed
locally on Donatella(for testing) following
  
  13073   Mon Jun 19 18:41:12 2017 jigyasaUpdateComputer Scripts / ProgramsMC2 Pitch-Yaw offsetThe previous run of the script had produced
some dubious results!

The script has been modified and
  
  13076   Tue Jun 20 17:44:12 2017 jigyasaUpdateComputer Scripts / ProgramsMC2 Pitch-Yaw offsetThe script didn't run properly last
night, due to an oversight of variable names!
It's been started again and has been
  
  13083   Tue Jun 27 16:18:59 2017 jigyasaUpdateCamerasGigE camera at ETMXThe 50mm lens has arrived. (Delivered yesterday).

Also the GigE has been wired and
conencted to the Martian. Image acquisition
  
  13084   Tue Jun 27 18:47:49 2017 jigyasaUpdateComputer Scripts / ProgramsMC2 Pitch-Yaw offsetThe values generated from the script were
analyzed and a 3D scatter plot in addition
to a 2D map were plotted. 
  
  13087   Thu Jun 29 10:04:18 2017 jigyasaUpdateComputer Scripts / ProgramsMC2 Pitch-Yaw offsetThe script is being executed again, now.




  