  6890   Thu Jun 28 22:08:57 2012 JenneBureaucracyLockingvent for PRC check, TOMORROW!

    

       
            
  
  6891   Fri Jun 29 01:49:36 2012 yutaBureaucracyLockingvent for PRC check, TOMORROW!

    

       
            
  
  6913   Wed Jul 4 20:13:46 2012 yutaBureaucracyLockingPRC commissioning planIssues in PRC:
  1. Power recycling gain is
too low (~ 15 instead of 40, according to
  
  6914   Wed Jul 4 21:11:53 2012 yutaUpdateLockingFPMI in vacuum is backI aligned FPMI and greens. There's no recognizable
difference between before and after the vent.
 ALL_1025495266.pngMEDMscreenshotswithCOW_20120704.png 
  6916   Thu Jul 5 01:34:11 2012 yutaUpdateLockingMI with X arm ALSI tried to lock FPMI using ALS, but I could
not take care of ALS for both arms + MI.
So, I decided to try one arm + MI.
  
  6922   Thu Jul 5 13:38:05 2012 yutaSummaryLockingcavity g-factor from mode scanCavity
g-factor for X arm is 0.3737 +/- 0.002, Y
arm is 0.3765 +/- 0.003.
  
  6925   Fri Jul 6 01:39:56 2012 yutaUpdateLockingMI + Y arm ALS succeed, but not bothMI with X arm length stabilized off resonance
and Y arm length stabilized at resonance
using ALS succeed, but I couldn't bring X
 FPMIALStrial20120706.pngnewALSMEDMscreen.png 
  6926   Fri Jul 6 02:46:03 2012 yutaUpdateLockingY arm ALS handing off to LSCHanding off the servo from ALS to LSC for
one arm is quite easy because servo filters
are pretty much same for ALS and LSC. I demonstrated
 handofftoLSC20120706.png 
  6938   Sun Jul 8 00:27:54 2012 yutaSummaryLockingcalibrating phase tracking mode scan dataFSR
for X/Y arm are 3.97 +/- 0.03 MHz and 3.96
+/- 0.02 MHz respectively. This
  
  6939   Sun Jul 8 00:58:08 2012 KojiSummaryLockingcalibrating phase tracking mode scan data

    

       
            
  
  6940   Sun Jul 8 19:31:53 2012 yutaUpdateLockingcharacterizing LSC arm lock by ALS error signalRMS
of X/Y arm length using POX/POY lock is <160
pm and <120 pm respectively. 
 XarmLengthspectra20120708.pngLSCPOYarmIRlockOLTF.pngYarmLengthspectra20120708.pngLSCPOXarmIRlockOLTF.png 
  6941   Mon Jul 9 05:02:58 2012 yutaUpdateLockingadjusted ALS filters, current RMSI adjusted filters of ALS to give more
phase margin.
RMS
 ALSXarmLengthspectra20120708.pngALSXarmOLTF.pngALSYarmOLTF.pngALSYarmLengthspectra20120708.png 
  7128   Thu Aug 9 00:14:02 2012 EricSummaryLockingYARM Locking and CalibrationToday I spent time locking the YARM
in order to calibrate the arm cavity. Here's
 cal_swept_sine3_tfmagcal_swept_sine3_tfphcal_swept_sine3_cohsensing_func_model.png 
  7130   Thu Aug 9 00:35:53 2012 JenneSummaryLockingYARM Locking and Calibration

    

       
            
  
  7134   Thu Aug 9 10:09:32 2012 EricSummaryLockingYARM Locking and Calibration

    

       
            
 cal_swept_sine3_magnitude.pdfcal_swept_sine3_phase.pdfcal_swept_sine3_coherence.pdf 
  7139   Fri Aug 10 09:51:51 2012 EricSummaryLockingYARM Locking and MeasurementsI forgot to post this last night, but I
locked the YARM again yesterday and misaligned
the other optics. I took measurements on
  
  7145   Fri Aug 10 16:39:44 2012 EricSummaryLockingMichelson LockingI'm working on locking the Michelson now
in order to put an excitation on one of the
  
  7149   Fri Aug 10 19:49:11 2012 EricSummaryLockingMichelson Locking Procedure and Measurements

  
  7168   Tue Aug 14 00:42:40 2012 JenneUpdateLockingPOX signal sometimes looks very funnyI'm trying to lock / align the Xarm, and
POX 11 I looks funny sometimes.
I attach 2 screenshots so you can
 POX_13Aug2012_LSCdisabled_pox_is_normalish.pngPOX_13Aug2012_LSCenabled_pox_is_squareish_funny.png 
  7169   Tue Aug 14 04:32:49 2012 rana, yoichiUpdateLockingPOX signal sometimes looks very funny The alignment was way off.
We moved the PZT, the BS, and the x arm to
get it to lock. Along the way we noticed
 ITMX_1028974969.bmpETMXF_1028975007.bmpETMXT_1028975105.bmpAS_1028975166.bmp 
  7208   Thu Aug 16 19:12:30 2012 JenneUpdateLockingLong arm lock stretches   YARM_awesome_lock_stretch.png 
  7240   Tue Aug 21 01:54:09 2012 JenneUpdateLockingFPMI locked - arms locked with IRI (for the first time personally) locked
the FPMI.  I have data for the POX11I,
POY11I, AS55Q error signals for each arm
  
  7246   Tue Aug 21 22:54:47 2012 JenneUpdateLockingRemoved beam dump from POY pathPOY was looking funny, and the YARM wasn't
locking.  It looked like POY wasn't
seeing any light at all.  I went to
  
  7250   Wed Aug 22 16:50:09 2012 JenneUpdateLockingDouble integrator in ARM LSC servosLast week, Rana changed the integrators
in the arm LSC servo filters to be double
integrators with complex poles. 
 DoubleIntegrator_timeSeries_LowRes.pngDoubleIntegrator_Bode_vs_Ramp_LowRes.png 
  7334   Tue Sep 4 11:32:58 2012 JenneUpdateLockingFriday in-vac workElog re: Friday's work
Adjusted PZT2 so we're hitting the
center of PR2. 
  
  7339   Tue Sep 4 20:06:04 2012 JenneUpdateLockingMC scan input switched to the 11MHz port of EOMSince the EOM's signal combiner (splitter
backwards) is frequency-independent, Koji
and Jamie (in the proper turn off, turn on
  
  7514   Wed Oct 10 00:18:58 2012 JenneUpdateLockingREFL camera alignedI moved some of the REFL optics on the
AS table by a teeny bit to accomodate the
new place that the REFL beam exits the chamber
  
  7573   Thu Oct 18 03:57:20 2012 JenneUpdateLockingAlignment is really bad??The goal of the night was to lock the Y
arm.  (Since that didn't happen, I moved
on to fixing the WFS since they were hurting
  
  7579   Fri Oct 19 01:21:42 2012 EvanUpdateLockingAligning PZTs, PRM[Evan, Jenne]
Tonight we made an attempt at getting
the PRM + ITMY aligned with correct input
  
  7581   Fri Oct 19 16:24:39 2012 ranaUpdateLockingAlignment is really bad?? 
 VENT
  
  7730   Tue Nov 20 02:57:24 2012 Ayaka, Den, KojiUpdateLockingred in armsWe aligned and locked x and y arms.
MCL loop makes arms lock unstable,
adds a lot of noise at frequencies 60-100
 8x 
  7736   Wed Nov 21 01:31:37 2012 Koji, AyakaUpdateLockingalignment on ETMX tableSince the transmission beam on ETMXT camera
seemed to be clipped, we checked the optics
on ETMX table.
 output.nv12.bmp 
  7872   Wed Jan 2 15:33:23 2013 JenneHowToLockingWe should retry in-air lockingImmediate things to do include finishing
installation of new TTs and re-routing of
oplev paths in the BS chamber, but after
  
  7905   Wed Jan 16 18:08:06 2013 JenneUpdateLockingExpected PRC gainsI was calculating the power recycling gains
we expect for different versions of the PRC,
and I am a little concerned that we aren't
  
  7906   Wed Jan 16 18:52:49 2013 JenneUpdateLockingPRM - Flat mirror cavity planGame plan:
* Put 2" G&H mirror into
BS chamber, in front of BS.
  
  7909   Wed Jan 16 20:27:16 2013 ranaUpdateLockingExpected PRC gainsWhy would we use such a bad optic in our
recycling cavity? Is 1.5% the spec for these
mirrors? Is this the requirement that Kiwamu
  
  7910   Thu Jan 17 00:17:31 2013 JenneUpdateLockingExpected PRC gains

    

       
            
  
  7913   Thu Jan 17 15:48:21 2013 JenneUpdateLockingPRM - Flat mirror cavity 
 2" G&H mirror is installed
on a DLC mount just in front of the BS. 
  
  7916   Fri Jan 18 00:41:34 2013 JenneUpdateLockingDust?I was thinking tonight about more possible
reasons that our PRC sucks, and I wonder
if dust on the BS could create the problem.
  
  7917   Fri Jan 18 09:54:18 2013 JenneUpdateLockingPRM - Flat mirror cavity

    

       
            
  
  7918   Fri Jan 18 12:08:08 2013 KojiUpdateLockingDust?No


  
  7928   Tue Jan 22 19:53:01 2013 JenneUpdateLockingPR-flat cavity status - not lockedThe PR-flat cavity is flashing, although
not locked.  I am too hungry to continue
right now.
  
  7931   Wed Jan 23 19:05:16 2013 JenneUpdateLockingPR-flat cavity status - locks!Status update
I (with help from Q) have redone
the POP path on the ITMX table.  1"
  
  7934   Wed Jan 23 20:46:46 2013 Zen MasterUpdateLockingPR-flat cavity status - locks!

    

       
            
 yinYang.png 
  7945   Mon Jan 28 17:01:19 2013 DenUpdateLockingVideo of PRM-flat test cavityWhat mode will you get if lock the cavity
PRM - ITMY/ITMX/TEST MIRROR without PR2,
PR3 and BS?
  
  7951   Tue Jan 29 10:50:02 2013 JenneUpdateLockingVideo of PRM-flat test cavity 
I think Den accidentally edited and
overwrote my entry, rather than replying,
  
  7957   Tue Jan 29 19:50:49 2013 JenneUpdateLockingBetter POP layout, no extra PRM motion with locked cavity[Jenne, Jamie, Manasa]
Today's activities focused on getting
the POP layout improved, so that we could
 HalfPRCL_PRM-flatMirror_RefsAreLocked_OthersUnlocked.pdfHalfPRCL_PRM-flatMirror_RefsAreLocked_OthersUnlocked.png 
  7959   Tue Jan 29 21:07:48 2013 JenneUpdateLockingPRM coils need diagonalizing 
 [Jenne, Jamie]
We tried actuating on PRM so that
  
  7961   Wed Jan 30 11:16:32 2013 JenneUpdateLockingMode spacing calc[Jenne, Jamie]
We did a few pen and paper calculations
yesterday to confirm for ourselves that the
  
  7966   Wed Jan 30 15:45:09 2013 ZachUpdateLockingMode spacing calc

    

       
            
 HOM11.pngHOM55.png 
ELOG V3.1.3-