ID |
Date |
Author |
Type |
Category |
Subject |
Text |
 |
5682
|
Mon Oct 17 23:28:32 2011 |
rana | Update | Electronics | StochMon | To get to the bottom of the RFAM mystery,
we've got to resurrect the StochMon to trend
the RFAM after the IMC. |
|
5681
|
Mon Oct 17 22:20:42 2011 |
Koji | Update | LSC | REFL165 removed from the table |
|
|
5680
|
Mon Oct 17 17:07:30 2011 |
steve | Update | SUS | ETMX oplev returning beam od 3 mm | ETMX oplev had 6 mm diameter beam
on the qpd. I relayed the beam path
with 2 lenses to get back 3 mm |
|
5679
|
Mon Oct 17 14:26:22 2011 |
Mirko | Update | CDS | Seismic BLRMS channels, new RMS calculation |
|
|
5678
|
Mon Oct 17 11:40:44 2011 |
Koji | Update | LSC | REFL165 removed from the table | REFL165 removed from the table for the
C(V) test |
|
5677
|
Mon Oct 17 11:06:31 2011 |
Mirko | Update | CDS | Piping data from c1lsc to c1oaf | Changed, recompiled, installed and restarted
c1rfm and c1oaf to get the MC1-3 Pitch and
Yaw data into the c1oaf model. |
|
5676
|
Mon Oct 17 10:43:14 2011 |
Mirko | Update | CDS | Commited changes to c1rfm | I want to make changes to c1rfm. Found
uncommited changes to it from Sept 27. Since
we recompiled it since then it should be |
|
5675
|
Mon Oct 17 07:57:24 2011 |
steve | Update | SUS | ETMX sus damping restored | |
|
5674
|
Sun Oct 16 05:35:18 2011 |
rana | Update | Computer Scripts / Programs | Failing to set SUS summary screen values |
|
|
5673
|
Sun Oct 16 02:30:00 2011 |
rana | Update | Electronics | Testing REFL165 | Unless the bias feedback circuit has been
tuned for the 1 mm diode, its possible that
you are seeing some C(V) effects. Its easy |
|
5672
|
Sat Oct 15 17:06:20 2011 |
Koji | Update | LSC | Installation REFL165 | REFL165 was installed on the AP table last
night.
Meanwhile I found the DC power level |
|
5671
|
Sat Oct 15 16:42:08 2011 |
Koji | Update | LSC | Testing REFL165 | Test results of new REFL165 (the
first attachment)
- The resonant freq 166.2MHz, |
 |
5670
|
Sat Oct 15 16:01:26 2011 |
kiwamu | Update | IOO | about LOCKIN module |
|
|
5669
|
Sat Oct 15 10:58:32 2011 |
rana | Update | IOO | MC WFS Output Matrix determination | In order to save time and sanity, you
should not measure the pitch ->yaw and
yaw-> pitch. It makes things too complicated |
|
5668
|
Sat Oct 15 04:53:41 2011 |
Suresh | Update | IOO | MC WFS Output Matrix determination | After we had a
rough idea of what the output matrix looks
like (see this elog), |
    |
5667
|
Fri Oct 14 18:38:41 2011 |
kiwamu | Update | SUS | C1:SUS-ETMX_SPDMon fixed |
|
|
5666
|
Fri Oct 14 16:20:11 2011 |
Zach | Update | SUS | C1:SUS-ETMX_SPDMon fixed | I offered to help Kiwamu with some of the
40m work. The first task was to figure out
why the ETMX side OSEM monitor was so low, |
  |
5665
|
Fri Oct 14 04:35:45 2011 |
kiwamu | Update | LSC | locking tonight | The
lock of DRMI wasn't stable enough to measure
the sensing matrix. Failed. |
|
5664
|
Thu Oct 13 23:58:38 2011 |
Koji | Update | LSC | fixing REFL165 | I already have reported in
this entry that REFL165 shows too high
DC output which does not depend on the light |
 |
5663
|
Thu Oct 13 21:44:48 2011 |
Mirko | Update | CDS | Seismic BLRMS channels, new RMS calculation | [Rana, Koji, Mirko]
We looked into the CDS RMS block c-code |
 |
5662
|
Thu Oct 13 21:40:59 2011 |
rana | Summary | VAC | Recovery from the power shutdown is completed | As it turns out Steve is not crazy
in this particular instance: the vacuum computer,
linux3 , has some issues. I can login just |
|
5661
|
Thu Oct 13 20:25:32 2011 |
Katrin | Update | Green Locking | LPF transfer function YARM | It is a 4th order filter with
cut of frequency of 120 kHz.
|
 |
5660
|
Thu Oct 13 14:23:09 2011 |
steve | Update | SUS | ITMX oplev with 3 mm beam on qpd | I replaced the JDSU-Uniphase 1125P
by 1103P He/Ne laser. This new laser had
2.8 mW output yesterday. It degraded to 0.5 |
 |
5659
|
Thu Oct 13 03:22:53 2011 |
kiwamu | Update | LSC | measurement of sensing matrix : just began | - status update on LSC activity :
The
measurement of the LSC sensing matrix has |
|
5658
|
Wed Oct 12 19:58:32 2011 |
Katrin | Update | Green Locking | Power splitter is unbalanced | The mini circuit power splitter ZFRSC-42S+
used at the YARM has no balanced output as
it should have according to the data sheet. |
|
5657
|
Wed Oct 12 18:54:02 2011 |
Katrin | Update | Green Locking | 60 Hz oscillation due to broken BNC cable | There was a 60 Hz and 120 Hz oscillation
on the green PDH photo diode output. After
a long search, I could identify that |
|
5656
|
Wed Oct 12 17:53:01 2011 |
kiwamu | Update | LSC | BS actuator response : fitting done and histroy of delays | An
update on calibration of the BS actuator
: A fitting has been done. |
|
5655
|
Wed Oct 12 08:43:30 2011 |
steve | Update | SUS | ITMX oplev improved a bit | Atm2 is before optical path adjustment.
The idea was to remove possible clipping
in vacuum. |
 |
5654
|
Wed Oct 12 00:35:42 2011 |
kiwamu | Update | LSC | TRY path realigned | The
TRY (TRansmitted light from Y arm ) path
was a bit realigned because there had been |
|
5653
|
Tue Oct 11 21:23:51 2011 |
Jenne | Update | LSC | Arm absl lengths |
|
|
5652
|
Tue Oct 11 19:11:25 2011 |
kiwamu | Update | LSC | Re: BS actuator reponse at low frequency : measured | I think
the precision due to the loop gain uncertainty |
|
5651
|
Tue Oct 11 17:32:05 2011 |
jamie | HowTo | Environment | 40m google maps link | Here's another useful link:
http://maps.google.com/maps?q=34.13928,-118.123756 |
|
5650
|
Tue Oct 11 15:19:17 2011 |
rana | HowTo | Environment | 40m map | The Kinemetrics dudes are |
 |
5649
|
Tue Oct 11 15:14:50 2011 |
rana | Update | LSC | BS actuator reponse at low frequency : measured |
|
|
5648
|
Tue Oct 11 03:35:16 2011 |
kiwamu | Update | LSC | BS actuator reponse at low frequency : measured | The response
of the BS actuator in a low frequency regime |
|
5647
|
Tue Oct 11 00:59:55 2011 |
Suresh | Update | IOO | Preliminary locking of WFS loops | [Kiwamu, Koji, Suresh]
After correcting several errors in
the WFS loops, we turned them on today and |
6x |
5646
|
Mon Oct 10 18:53:04 2011 |
Katrin | Update | Green Locking | Mirrors whose angle of incidence is not 45° | The angle of incidence of light is for
some mirrors on the YARM end table different
from 45° even though the mirrors are |
|
5645
|
Mon Oct 10 16:32:18 2011 |
steve | Update | SUS | UL sensor of ETMY is recovered | I lost UL osem voltage this morning
when I was checking the actual connection
at rack ETMY |
  |
5644
|
Mon Oct 10 15:41:56 2011 |
Koji | Update | PSL | PMC aligned | [Koji Suresh]
The steering mirrors for PMC were
aligned. The transmission went up from 0.779 |
|
5643
|
Mon Oct 10 13:52:04 2011 |
kiwamu | Update | LSC | RE: First attempt to estimate mode matching efficiency using interferometer |
|
|
5642
|
Mon Oct 10 12:14:00 2011 |
Mirko | Update | Computer Scripts / Programs | IMC simulations | [Mirko, Kiwamu]
I tried to answer two questions regarding
the IMC: |
   |
5641
|
Mon Oct 10 10:14:43 2011 |
rana | Update | LSC | length fluctuations in SRCL | How does it make sense that the motion
at 0.1 Hz of PRC is 10x larger than MICH?
|
|
5640
|
Mon Oct 10 00:01:26 2011 |
Koji | Update | LSC | First attempt to estimate mode matching efficiency using interferometer | "^2"s are missing in the second
equation, but the calculation results seem
correct. |
|
5639
|
Sun Oct 9 17:13:46 2011 |
kiwamu | Update | LSC | First attempt to estimate mode matching efficiency using interferometer | The efficiency
of the mode matching (MM) to PRC (Power-Recycling |
|
5638
|
Sat Oct 8 04:41:07 2011 |
kiwamu | Update | LSC | length fluctuations in SRCL | For a comparison,
the length fluctuation of Signal-Recycled |
|
5637
|
Sat Oct 8 00:44:42 2011 |
kiwamu | Update | LSC | calibration of SRM actuator | The AC response
of the SRM actuator has been calibrated. |
|
5636
|
Fri Oct 7 23:23:05 2011 |
kiwamu | Update | SUS | SRM oplev was oscillating | The SRM oplevs were found to be oscillating
because of a small phase margin.
I reduced the gains to the half of |
|
5635
|
Fri Oct 7 22:48:26 2011 |
Suresh | Update | IOO | MC2 Trans QPD spot size and incident power decreased | After centering the spot on the MC2, I
started to adjust the spot position on MC_TRANS_QPD
to center the beam on it. I noticed |
|
5634
|
Fri Oct 7 22:41:05 2011 |
Koji | Configuration | General | Script backup fixed | Script backup regularly runs on
op340m by crontab,
|
|
5633
|
Fri Oct 7 22:31:53 2011 |
kiwamu | Update | SUS | noisy ULSEN on ETMY | Yesterday
Koji was claiming that the rms monitor of
ULSEN on ETMY didn't well go down. |
|