  10547   Mon Sep 29 09:11:25 2014 SteveUpdateVACvent day 5 RGA scan 
 
 v77_bg-mag-d5.png 
  10548   Mon Sep 29 10:29:25 2014 SteveUpdateVACRGA is not running 
 The RGA time stamp was correct
last at 20140527
 rgascanTimeStamp.png 
  10549   Mon Sep 29 12:47:51 2014 ericqUpdateGeneralVent update

    

       
            
  
  10550   Mon Sep 29 17:10:51 2014 ericqUpdateGeneralVent updateEverything is aligned, AS and POY make
it out of vacuum unclipped, OSEM readings
look good.
  
  10551   Mon Sep 29 18:12:24 2014 ericqUpdateGeneralVent updateI closed the PSL shutter as we didn't want
to burn the mirror surface when we are not
working.
  
  10552   Tue Sep 30 11:53:29 2014 ericqUpdateGeneralVent update 
Photos have been taken of the ITMY
chamber, and uploaded to picasa. Here's a
  
  10553   Tue Sep 30 16:18:57 2014 SteveUpdateVACpump down #78 has started 
Q checked the earth quake stops of
SRM and we put the ITMY & BS doors on. 
 pd78hastarted.png 
  10554   Tue Sep 30 17:26:18 2014 ericqUpdateLSCNew AO cable in placeI've installed a new 2pin lemo cable going
from the CM servo out to in2 of the MC servo
board, and removed the temporary BNC. I used
  
  10555   Tue Sep 30 18:02:53 2014 SteveUpdateVACpump down #78 stops at 320 Torr 
We  stopped pumping just short
of 3 hours at 320 Torr.  Pumping speed
 3h.png 
  10556   Wed Oct 1 10:21:19 2014 SteveUpdateVACpump down #78 stops at 3.5 Torr

    

       
            
 pd78secondStop.png 
  10557   Wed Oct 1 16:26:53 2014 SteveUpdateVACpump down #78 completed 
 Pump down reached "vacuum
normal" state. IFO _P1 pressure 1e-4
 pd78completedin25hrs.png 
  10558   Wed Oct 1 19:40:46 2014 ericqUpdateLSCArms IR alignedSummary:

    Beamsplitter
was put into MC refl path.
    HWP
was rotated to maximize power into PMC. 
  
  10559   Thu Oct 2 09:23:23 2014 SteveUpdateVACvent 77

    

       
            
 vent77SRMmoved.png 
  10560   Thu Oct 2 14:36:52 2014 steveUpdatePEMoil drops on vertex crane

    

       
            
 VertexOilDrops.jpg 
  10561   Thu Oct 2 20:54:45 2014 KojiUpdateIOOIMC WFS measurements[Eric Koji]
We made sensing matrix measurements
for the IMC WFS and the MC2 QPD.
 IMC_RIN_141002.pdfIMC_WFS_141002.pdf 
  10562   Fri Oct 3 03:02:17 2014 ericqUpdateLSCNo luck locking DRMII haven't been able to lock the DRMI tonight,
neither with 1F and no arms nor 3F and arms
held off with ALS... I tried previous recipes,
  
  10563   Fri Oct 3 10:10:37 2014 SteveUpdateVACcold cathode gauge reading switched 
We have two cold cathode gauges at
the pump spool and one  signal cable
 CC1switched.png 
  10564   Fri Oct 3 13:03:05 2014 ericqUpdateIOOIMC WFS measurementsYesterday, Koji and I measured the transfer
function of pitch and yaw excitations of
each MC mirror, directly to each quadrant
 WFS1PIT.pdfWFS2PIT.pdfWFS1YAW.pdfWFS2YAW.pdfanalyzeWfs.zip 
  10565   Sun Oct 5 10:09:49 2014 ranaUpdateIOOIMC WFS measurementsIt seems clever, but I wonder
why use DTT and command line perl, instead
of using the FE lockins or just demod the
  
  10566   Sun Oct 5 23:43:08 2014 KojiUpdateIOOIMC WFS measurementsThere are several non scientific reasons.   
  10567   Mon Oct 6 10:04:58 2014 manasaUpdateGeneralUnexpected power shutdownWe had a unexpected    
  10568   Mon Oct 6 10:23:43 2014 SteveUpdateVACUnexpected power shutdown

    

       
            
  
  10569   Mon Oct 6 10:28:18 2014 manasaUpdateGeneralUnexpected power shutdown

    

       
            
  
  10570   Mon Oct 6 11:09:52 2014 JenneUpdateGeneralUnexpected power shutdown: slow computersAs per other slow computers, which Chris
figured out in elog
10189, I added all the rest of the slow
  
  10571   Mon Oct 6 17:04:51 2014 ericqUpdateGeneralUnexpected power shutdownI brought back the PMC, MC and Arms.
PMC:

    Same as when we replaced
  
  10572   Mon Oct 6 17:36:17 2014 ericqUpdateGeneralUnexpected power shutdownThe autolocker is now working, but I didn't
change anything to make it so. I was just
putting in some echo statements, to see where
  
  10573   Mon Oct 6 18:15:12 2014 manasaUpdateGeneralUnexpected power shutdown: end green alignmentAfter Q brought back the IR, I went to
check the green situation.
1. The end lasers had to be turned
  
  10574   Tue Oct 7 00:18:12 2014 JenneUpdateLSCYgreen PSL alignment, ETMX strain reliefNo exciting progress today.  I did
PSL green alignment for the Yarm, although
I now think that the Xarm green needs realigning
  
  10575   Tue Oct 7 10:09:07 2014 manasaUpdateGeneralChiara not respondingChiara  doesn't seem to be responding and
I guess something happened 7 hrs ago.
I tried to hook up chiara to a monitor
  
  10576   Tue Oct 7 16:17:15 2014 SteveUpdateGeneralreason for 8 sec power outage

    

       
            
  
  10577   Tue Oct 7 16:19:50 2014 ericqUpdateGeneralChiara not respondingWe're back! It   
  10578   Tue Oct 7 16:41:12 2014 JenneUpdateGeneralChiara not respondingI put a little script into ...../scripts/Admin
that will check the fullness of Chiara's
disk.  We only have the mailx program
  
  10579   Tue Oct 7 16:55:16 2014 SteveUpdateVACUnexpected sweaty valves Pump  spool valves V5, V4, V3
sweating a lot. VM3 and VC2 not so much.
 sweatyV5.jpgsweatyV5f.jpg 
  10580   Tue Oct 7 19:40:58 2014 ericqUpdateLSCCM, REFL11 WiringI've changed the LSC rack wiring a little
bit, to give us some flexibility when it
comes to REFL11. 
  
  10581   Wed Oct 8 03:20:46 2014 JenneUpdateLSCDo we need AO for acquisition?As part of trying to determine whether
we require the AO path for lock acquisition,
or if we can survive on just digital loops,
 EstimatedNoisePerformance.pngBodeLSCvsALS.pngCARMnoise_7Oct2014.zip 
  10582   Wed Oct 8 03:37:44 2014 ericqUpdateLSCPRFPMI, other sign of CARM offset [ericq, Jenne]
We attempted some of the same old
CARM offset reduction tonight, but from the
  
  10583   Wed Oct 8 03:49:42 2014 JenneUpdateLSCPRFPMI, other sign of CARM offsetOther thoughts from talking with Rana earlier:

    Is it possible to suppress
CARM motion enough that we can use just a
  
  10584   Wed Oct 8 08:46:57 2014 SteveUpdateVACVAT valves actuator lubricant

    

       
            
  
  10585   Wed Oct 8 15:31:31 2014 JenneUpdateCDSComputer statusAfter the Great Computer Meltdown of 2014,
we forgot about poor c0rga, which is why
the RGA hasn't been recording scans for the
  
  10586   Thu Oct 9 10:52:37 2014 manasaUpdateGeneralPower outage II & recoveryPost 30-40min unexpected power outage this
morning, Steve checked the status of the
vacuum and I powered up Chiara.
  
  10587   Thu Oct 9 11:56:35 2014 SteveUpdateVACPower outage II & recovery

    

       
            
  
  10588   Thu Oct 9 13:29:14 2014 JenneUpdatePSLPower outage II & recovery

    

       
            
  
  10589   Thu Oct 9 16:31:53 2014 ericqUpdateLSCCARM W/N TFsIn my previous simulation results, I've
always plotted W/m, which isn't exactly straightforward.
We often think about the displacement that
 carm2SQRTinv.pdfcarm2REFLDC.pdf 
  10590   Thu Oct 9 17:33:28 2014 SteveUpdateVACPower outage II & recovery

    

       
            
 pumpingAgain.png 
  10591   Thu Oct 9 18:30:59 2014 JenneUpdateLSCCARM W/N TFsOkay, here (finally) is the optickle version.
I have the antispring case, starting
at 501pm and going roughly every 10pm down
 6x 
  10592   Thu Oct 9 19:14:04 2014 ericqUpdateGeneralPower outage II & recoveryI touched up the PMC alignment. 
While bringing back the MC, I realized
IOO got a really old BURT restore again...
  
  10593   Fri Oct 10 00:20:37 2014 ranaUpdateLSCCARM W/N TFs 
 Assuming that these Watts/Newtons
TFs are correct, I've modeled the resulting
 carm40.pngcarm.pdf 
  10594   Fri Oct 10 03:05:09 2014 ericqUpdateLSCWhich side of optical spring are we on? I made some measurements to try and
see if any difference could be seen with
different CARM offset signs. 
 comparison.pdf 
  10595   Fri Oct 10 03:25:11 2014 JenneUpdateLSCWhich side of optical spring are we on (simulation)I have a simulated version of the differences
that we expect to see between the 2 different
sides of the CARM resonance.  The point
 10x 
  10596   Fri Oct 10 14:27:44 2014 SteveUpdateCDSc1Vac1 and c1vac2 reboot was a failure

    

       
            
 c1vac1resetReboot.pngc1Vac1&2down.jpg 
ELOG V3.1.3-