  15798   Wed Feb 10 14:14:58 2021 gautamUpdateElectronicsCustom cables receivedWe received the custom cables to test the
new suspension electronics. They are under
my desk. So we are ready.
 satWiring.pdf 
  15800   Wed Feb 10 15:25:45 2021 gautamSummaryBHDSatellite Amplifier Output Offset measurementsWhy not just do this test with the dummy
suspension box and CDS system? I think Rich's
claim was that the intrinsic LED RIN was
  
  15802   Wed Feb 10 21:14:03 2021 gautamUpdateElectronicsProduction version of the HV coil driver testedSummary:

I did what I consider to be a comprehensive
set of tests on the production version of
 inputDiffRecTF.pdfLVnoises.pdftotalNoise.pdftimeDomainTests.pdf 
  15805   Thu Feb 11 18:21:39 2021 gautamUpdateSUSMC suspension glitchesMC1
suspension is glitching again, so
this is a good chance to install the new
  
  15809   Tue Feb 16 14:56:44 2021 gautamUpdateSUSaLIGO Sat Amp installed, powered[jordan,
gautam]


Ran 60ft long cables from
 MC1_deadUL.pngIMG_9100.jpg 
  15812   Wed Feb 17 13:59:35 2021 gautamUpdateDetCharSummary pagesThe summary pages had failed because of
a conda env change. We are dependent on detchar's
  
  15814   Wed Feb 17 16:11:53 2021 gautamUpdateSUSaLIGO Sat Amp installed, poweredThere is some non-trivial sign flipping
in the sensors/coils in this new setup because
it is a hybrid one with the old interfacing
  
  15817   Thu Feb 18 15:33:21 2021 gautamUpdateSUSaLIGO Sat Amp installed, powered and commissionedThe WFS servo was recommissioned. The matrix
can be tuned a bit more, but for now, I've
recovered the old performance and the alignment
  
  15818   Thu Feb 18 18:05:04 2021 gautamUpdateSUSaLIGO Sat Amp characterizationBefore installation, I performed a bunch
of tests on the aLIGO sat amp. All the measurements
were made with the dummy suspension box substituting
 OSEMnoise.pdfLEDdriveNoise.pdf 
  15822   Fri Feb 19 13:38:26 2021 gautamUpdateLSCPRFPMII forgot that I had already done some investigation
into recovering the PRFPMI lock after my
work on the RF source. I don't really
  
  15825   Fri Feb 19 16:14:16 2021 gautamUpdateSUSCoM Range on 3"->2" Adapter Ring for SOSI briefly talked with Jordan about this.
This suspension will have OSEMs right? With
400ohm series resistance for the coil drivers,
  
  15828   Sat Feb 20 10:01:48 2021 gautamSummaryElectronicsA bunch of electronics receivedWill we also be receiving the additional
34 Satellite Amplifier PCBs?
  
  15829   Sat Feb 20 16:20:33 2021 gautamUpdateGeneralHousekeeping + PRMI charIn prep to try some of these
debugging steps, I did the following.


ndscope updated from 0.7.9 to
 IPPOSdeat.pdfTTdrift.pdfPOXnPOY.pdfPRMI.pdf 
  15833   Mon Feb 22 14:53:47 2021 gautamUpdateCDSdtt-ezca-tools installed on rossaThe defaults cds-crtools didn't come
with some of the older ezcautils (like ezcaread,
ezcawrite etc). This is now packaged for
  
  15834   Tue Feb 23 00:10:05 2021 gautamUpdateGeneralDemod char part 1I measured the conversion efficiencies
for all the RFPD demod boards except the
POP port ones. An RF source was used to drive
 noPreamp.pdfwithPreamp.pdf 
  15839   Wed Feb 24 11:53:24 2021 gautamUpdateGeneralDemod char part 2I measured the noise of the I/F outputs
of all the LSC demodulators. I made the measurement
in two conditions, one with the RF input
 noises_noPreamp.pdfnoises_withPreamp.pdf 
  15840   Wed Feb 24 12:11:08 2021 gautamUpdateGeneralDemod char part 3I did the characterization discussed at
the meeting today.


RF signal at 100 Hz offset
 noPreamp.pdfwithPreamp.pdfnoPreamp_whitened.pdfwithPreamp_whitened.pdf 
  15841   Wed Feb 24 12:29:18 2021 gautamUpdateGeneralInput pointing recoveredWhile working at the LSC rack, I lost the
input pointing into the IFO (the TT wiring
situation is apparently very fragile, and
  
  15843   Thu Feb 25 14:30:05 2021 gautamUpdateCDSnew c1bhd setup - diskless bootI've set up one 2U server unit received
from KT in the control room area (the fans
in it are pretty loud but other than
  
  15844   Thu Feb 25 16:50:53 2021 gautamUpdateGeneralPRMI sensing matrixAfter all the work at the LSC rack over
the last couple of days, I re-locked the
PRMI (ETMs misaligned), and measured the
 PRMI1f_noArmssensMat.pdf 
  15845   Thu Feb 25 20:37:49 2021 gautamUpdateGeneralSetting modulation frequency and checking IMC offsetThe Marconi frequency was tuned by looking
at 


The ~3.68 MHz (= 3*f1 -
 modFreq.pdfIMC_offset.pdf 
  15846   Fri Feb 26 16:31:02 2021 gautamUpdateElectronicsProduction version of the HV coil driver tested with KEPCO HV suppliesKoji asked me to test the production version
of the coil driver with the KEPCO HV supplies.
See 
 totalNoise_KEPCO.pdf 
  15848   Sat Feb 27 17:25:42 2021 gautamUpdateElectronicsProduction version of the HV coil driver tested with KEPCO HV suppliesI will try the test of switching out KEPCOs
one at a time for the HP. Given that the
passive RC filter doesn't filter
  
  15850   Sun Feb 28 22:53:22 2021 gautamUpdateLSCmore PRMI checks here: what it is ain't exactly clearI looked into this a bit more and crossed
off some of the points Rana listed. In order
to use REFL 55 as a sensor, I had to fix
 PRMI_SBres_REFL55.pngPRMI1f_noArmssensMat.pdfPRMI1f_noArmssensMat.pdfPRMI_locked.pngactTFs.pdf 
  15852   Mon Mar 1 12:36:38 2021 gautamSummaryIMCgetting familiar with IMC controlsPretty minor thing - but PMCT and PMCR
were switched on Quad 2 for whatever reason.
I switched them back because I prefer the
  
  15853   Mon Mar 1 16:27:17 2021 gautamUpdateLSCPRM violin filter excessive?The PRM violin filter seems very suboptimal
- the gain peaking shows up in the MICH OLTF,
presumably due to the MICH-->PRM LSC output
 violins.pdfPRviolin.pdf 
  15855   Tue Mar 2 19:52:46 2021 gautamUpdateLSCREFL55 demod board reworkThere were multiple problems with the REFL55
demod board. I fixed them and re-installed
the board. The TFs and noise measured on
  
  15859   Wed Mar 3 22:13:05 2021 gautamUpdateLSCREFL55 demod board reworkAfter this work, I measured that the orthogonality
was poor. I confirmed on the bench that the
PQW-2-90
  
  15860   Wed Mar 3 23:23:58 2021 gautamUpdateALSArm cavity scanI see no evidence of anything radically
different from my PSL table optical
characterization in the IMC transmitted
 armScan.pdf 
  15867   Fri Mar 5 13:53:57 2021 gautamUpdateLSCREFL55 demod board rework0 dBm ~ 0.63 Vpp. I guess there is ~4dB
total loss (3dB from splitter
and 1dB from total excess loss above theoretical
  
  15868   Fri Mar 5 15:03:28 2021 gautamSummaryElectronicsA bunch of electronics receivedThe PCBs for the D1002593
BIO I/F (5pcs ea of D1001050
and D1001266)
  
  15871   Fri Mar 5 16:24:24 2021 gautamUpdateLSCREFL55 demod board re-installed in 1Y2I don't have a good explanation why,
but I too measured similar numbers to what
Koji measured. The overall conversion gain
 REFL55.pdfdemodNoise.pdf 
  15873   Fri Mar 5 22:25:13 2021 gautamUpdateLSCPRMI 1f SB locking recoveredNow that the REFL55 signal chain is capable
of providing balanced, orthogonal readout
of the two quadratures, I was able to recover
 PRMI1f_noArmssensMat.pdf 
  15874   Sat Mar 6 12:34:18 2021 gautamUpdateLSCSensing matrix settings messed withTo my dismay, I found today that somebody
had changed the oscillator frequencies for
the sensing matrix infrastructure we have.
 sensMat.png 
  15875   Sun Mar 7 15:26:10 2021 gautamUpdateLSCHousekeeping + more PRMI
Beam pointing into PMC was tweaked
to improve transmission.
AS110
photodiode was re-installed on the AS table
 PRMI_SBres.pngMICH_act_calib.pdf 
  15878   Mon Mar 8 12:40:35 2021 gautamSummarytrainingInvestigate how-to XARM lockingFor the arm locking, the "Restore
Xarm (XARM POX)" script from the "IFO_CONFIGURE"
MEDM screen should get you there (I just checked
  
  15879   Mon Mar 8 12:54:54 2021 gautamUpdateEquipment loan40m-->Cryo
Busby box
SR554 transformer
preamplifier
  
  15880   Mon Mar 8 17:09:29 2021 gautamUpdateSUSPRM coil actuators heavily imbalancedI realized I hadn't checked the PRM
actuator as thoroughly as I had the others.
I used the Oplev as a sensor to check the
 PRMact.pdf 
  15883   Mon Mar 8 22:01:26 2021 gautamUpdateLSCMore PRMIThere are still many mysteries remaining
- e.g. the MICH-->PRCL contribution still
can't be nulled. But for now, I have
 PRMI1f_noArmssensMat.pdfPRMI3f_noArmssensMat.pdf 
  15887   Tue Mar 9 14:37:26 2021 gautamSummarySUSPRM suspensionThe PRM got tripped ~5AM this morning.
The cause is unclear - the seismometer reports
elevated activity ~10 minutes before the
 PRMtrip.png 
  15892   Wed Mar 10 00:32:03 2021 gautamUpdateLSCPRFPMiThe interferometer can nearly be locked
again. I was unable to fully hand off control
from ALS-->RF, I suspect I may be using
 PRMI3f_ALSsensMat.pdf 
  15894   Wed Mar 10 11:55:22 2021 gautamUpdateSUSPRM suspension suspectThe procedure is that the optic is kicked
to excite it, and allowed to ring down for
~1ksec, with damping turned off. The procedure
 PRM_sensorSpectra.pdfPRM_pkFitNaive.pdfPRM_diagComp.pdf 
  15895   Wed Mar 10 15:00:16 2021 gautamSummaryIMCIMC free swinging prepDid you fix this issue? It is helpful to
post a screenshot of the offending MEDM screen
in addition to witticisms. The elog says
  
  15898   Wed Mar 10 17:35:47 2021 gautamUpdateSUSSpooky action at a distanceAs I am sitting in the control room, the
PRM suspension watchdog tripped again. This
time, there is clearly no
 PRMtrip.pngPRMtrip_zoom.png 
  15899   Wed Mar 10 19:58:27 2021 gautamUpdateLSCSR785 hooked up to CM boardIn preparation for later today evening.
The TT alignment wasn't visibly disturbed.
  
  15900   Thu Mar 11 01:45:42 2021 gautamUpdateLSCPRFPMi
PRM satellite box indeed seems
to have been the culprit - shortly after
I swapped it to the SRM, its shadow sensors
  
  15903   Thu Mar 11 14:03:02 2021 gautamUpdateLSCAO pathThere is some evidence of weird saturation
but the gain balancing (0.8dB) and orthogonality
(~89 deg) for the daughter board on the REFL11
 IMG_9127.HEIC 
  15904   Thu Mar 11 14:27:56 2021 gautamUpdateCDStimesync issue?I have recently been running into hitting
the 4MB/s data rate limit on testpoints -
basically, I can't run DTT TF and spectrum
 timesync.pngc1lscMods.png 
  15905   Thu Mar 11 18:46:06 2021 gautamUpdateCDScds rebootSince Koji was in the lab I decided to
bite the bullet and do the reboot. I've
modified the reboot script - now, it prompts
 CDSoverview.png 
  15906   Thu Mar 11 20:18:00 2021 gautamUpdateLSCHigh bandwidth POYI repeated the high bandwidth POY locking
experiment.


The "Q" demod
 OLGevolution.pdfinLoopSpec.pdf 