40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 232 of 344  Not logged in ELOG logo
IDup Date Author Type Category Subject Text Attachments
  11626   Mon Sep 21 11:40:30 2015 ericqUpdateGeneralMegatron maitenenceThe MC autolocker and FSSslow scripts weren't
running on Megtron. These were started by
running the following commands on megatron:
  
  11627   Mon Sep 21 15:22:19 2015 jamieUpdateDAQworking on new fb replacementI've been putting together a new machine
that Rolf got for us as a replacement for
fb.
  
  11628   Mon Sep 21 18:31:06 2015 gautamSummaryComputer Scripts / ProgramsFrequency counting algorithmI have been
working on setting up a frequency counting
module that can give us a readout of the
 6x 
  11629   Mon Sep 21 23:18:55 2015 ericqSummaryComputer Scripts / ProgramsFrequency counting algorithmI definitely think lowpassing the output
is the way to go. Since this frequency readback
will be used for slow control of the beatnote
  
  11631   Tue Sep 22 02:11:17 2015 ranaSummaryComputer Scripts / ProgramsFrequency counting algorithmI was going to suggest using a software
PLL, but perhaps averaging gives the same
result. The same ADC signal can be fed to
  
  11632   Tue Sep 22 03:48:18 2015 ericqUpdateLSCDRMI tweaked, briefly held with ALS armsGiven the RF component power supply grounding,
POP110, POP22 and REFL165 all changed somewhat.
They have all been rephased for the DRMI,
  
  11633   Tue Sep 22 08:58:38 2015 SteveUpdateVACcold cathode is flakyThe cold cathode gauge is back to normal.
cc4 is the last gauge is "functioning"

MKS is not responding. The spare
 4and80days.png 
  11634   Tue Sep 22 16:42:39 2015 ericqUpdateIOOHousekeepingI've moved the OAF MC2 signal path
to go directly from c1oaf to c1mcs, so that
the LSC being ON/OFF doesn't interfere
  
  11635   Tue Sep 22 16:52:36 2015 ericqSummaryGeneralRandom NotesSome things bouncing around my head that
haven't made it to ELOG yet:


Last week, Rana and I were
  
  11636   Tue Sep 22 17:30:55 2015 jamieUpdateDAQattempts at getting new fb workingToday I've been trying to get the new
frame builder, tentatively 'fb1',
to work.  It's not fully
  
  11637   Wed Sep 23 03:08:50 2015 ericqUpdateLSCDRMI + ALS Arms[ericq, Gautam]

We can reliably
 DRMIarms.pdf 
  11638   Wed Sep 23 10:31:49 2015 ericqUpdateLSCDRMI + ALS ArmsLooking good. How many meters of CARM is
'-1 counts'?
  
  11639   Wed Sep 23 12:51:03 2015 JenneUpdateLSCDRMI + ALS ArmsNice!!    
  11640   Thu Sep 24 17:01:37 2015 ericqUpdateComputer Scripts / ProgramsFreeing up some space on /cvs/cdsI noticed that Chiara's backup HD (which
has a capacity of 1.8TB, vs the main drives
2TB) was near to getting full, meaning that
  
  11641   Thu Sep 24 17:06:14 2015 ericqUpdateCalibration-RepairC1CAL LockinsJust a quick note for now: I've repopulated
C1CAL with a limited set of lockin oscillators/demodulators,
informed by the aLIGO common LSC model. Screens
  
  11642   Fri Sep 25 11:08:33 2015 SteveUpdateSUSwire standoffsOur last effort to change the existing
Al-6061 wire standoffs was at April 2012

We requested sapphire and/or ruby
 wireStandOff_SOS.PDF 
  11643   Fri Sep 25 14:52:08 2015 SteveUpdateSUSETMX is not driftingWe have talked about the drift of ETMX
sus on the Wednesday meeting.

It has stopped moving on Jan 8,
 ETMXstoppedDrifting.png25daysArmsT.png 
  11644   Fri Sep 25 17:00:38 2015 SteveUpdateVACcold cathode is flakyThe IFO pressure is estimated ~1E-6 Torr
with modified Vac normal valve configuration.

CC4 is in a jumping mode between
 flakyCC4.png 
  11645   Fri Sep 25 17:51:11 2015 jamieUpdateDAQfb replacement work updateBrief update about the fb replacement status.

The new hardware for fb is in the
rack, temporarily sitting on top of megatron,
  
  11646   Fri Sep 25 19:06:13 2015 ranaUpdateSUSETMX IS driftingI don't see any evidence of it getting
more stable. It seems there was a big step
in January, but the problem we were talking
  
  11647   Tue Sep 29 03:14:04 2015 gautamUpdateCDSFrequency divider boxEarlier today, the front panels for the
1U chassis I obtained to house the Wenzel
dividers + RF amplifiers arrived, which meant
 IMG_0014.JPGIMG_0015.JPG 
  11648   Tue Sep 29 16:52:49 2015 ericqUpdateLSCFast ALS troubles - unknown zeroFast ALS control continues to elude me. 

I fixed my LPF to take the input
impedance of the CM board input into account;
 OLG_fastALS.pdf 
  11649   Tue Sep 29 18:03:11 2015 ranaUpdateLSCuse LISOUse LISO - see what it tells you. I would
think that you should make a differential
RC filter to get the right behavior. (e.g.
 Screen_Shot_2015-09-29_at_5.55.34_PM.png 
  11650   Tue Sep 29 19:38:09 2015 gautamUpdateGeneralFOL fiber box revampThe new 2x2 fiber couplers arrived today
so Eric gave me an overview on the changes
to be made to the existing configuration
 IMG_0017.JPGFOL_schematic.pdfIMG_0018.JPGIMG_0016.JPG 
  11651   Wed Sep 30 10:00:02 2015 ericqUpdateLSCused LISOLISO confirms that I did my algebra right
in picking the component values, and shows
no extra zeros. 
  
  11652   Wed Sep 30 13:07:13 2015 gautamUpdateGeneralFOL fiber box revampEric pointed out that the 1x2 couplers
that were used in the previous arrangement
and which I recycled, were in fact NOT
 FOL_schematic.pdf 
  11653   Wed Sep 30 13:59:49 2015 jamieUpdateDAQattempts at getting new fb workingI got Steve to get us a new Myrinet fiber
network adapter card for fb1:


Myrinet 10G-PCIE-8B-S


I
  
  11654   Wed Sep 30 15:44:06 2015 SteveUpdateGeneralSun Fire X4600Gautam and
Steve,

The decommissioned server
  
  11655   Thu Oct 1 19:49:52 2015 jamieUpdateDAQmore failed attempts at getting new fb workingSummary

I've not really
been able to make additional progress with
the new 'fb1' DAQ.  It's
  
  11656   Thu Oct 1 20:24:02 2015 jamieUpdateDAQmore failed attempts at getting new fb workingI just realized that when running fb1,
if a single mx_stream dies they all die.
  
  11657   Thu Oct 1 20:26:21 2015 jamieUpdateDAQSwapping between fb and fb1Swapping between fb and fb1 as DAQ is very
straightforward, now that they are both on
the DAQ network:
  
  11658   Fri Oct 2 03:29:16 2015 ericqUpdateLSCFast ALS progress - AO path crossed over, but no high BWI've been using an SR560 to experiment
with differnent pole frequencies, to try
and cancel the mystery zero. It's after
 crossedover.pdf 
  11659   Fri Oct 2 15:11:08 2015 SteveUpdatePEMcable squashedCable numbered #53 from Accelerometer 4
to 1X7 / DAQ input c26 was squased while
removing network card from Sun Fire x4600
  
  11660   Fri Oct 2 15:33:09 2015 SteveUpdatesafetysafety trainingGautom
has received 40m specific basic safety training
today.
  
  11661   Sun Oct 4 12:07:11 2015 jamieConfigurationCDSCSD network tests in progressI'm about to start conducting some
tests on the CDS network.  Things will
probably be offline for a bit.  Will
  
  11662   Sun Oct 4 13:53:30 2015 jamieUpdateLSCSENSMAT oscillator used for EPICS testsI've taken over one of the SENSMAT
oscillators for a test of the EPICS system.

These are the channels I've
  
  11663   Sun Oct 4 14:23:42 2015 jamieConfigurationCDSCSD network test completeI've finished, for now, the CDS network
tests that I was conducting.  Everything
should be back to normal.
  
  11664   Sun Oct 4 14:28:03 2015 jamieUpdateDAQmore failed attempts at getting new fb workingI tried to look at fb1 again today, but
still haven't made any progress.

The one thing I did notice, though,
  
  11665   Sun Oct 4 14:32:49 2015 jamieConfigurationCDSCSD network test completeHere's an example of the glitches we've
been seeing, as seen in the StripTool trace
of the front end oscillator:
 45.png 
  11666   Mon Oct 5 10:11:35 2015 SteveUpdateVACRGA scan pd78 day 386RGA background scan.

The IFO is closed off from RGA
with VM1
 RGA_background.png 
  11667   Mon Oct 5 11:25:21 2015 ericqUpdateSUSETMY OL laser deadGautam alerted me that the Y arm looked
like it was being dithered, even though the
ASS was turned off. I found that the ETMY
 ETMY-OLSUM.png 
  11668   Mon Oct 5 16:41:22 2015 SteveUpdateSUSETMY OL laser replacedThis JDSU 1103P laser, sn P892324 lived
for 2 years. It's power output is 0.05
mW now
  
  11669   Tue Oct 6 03:30:17 2015 ericqUpdateLSCDRFPMI Progress[ericq, Gautam]

Highlight of the night: the DRFPMI
was held at arm powers > 110 for 20 seconds.
  
  11670   Tue Oct 6 16:56:40 2015 gautamUpdateGeneralFOL fiber box revamp[gautam, ericq]

We had a look at the IR beat (PSL+Xarm)
today using the new FOL fiber box, and compared
 20151006_Xbeat_psd.pdf20151006_Xbeat_coherence.pdf 
  11671   Thu Oct 8 04:48:50 2015 ericqUpdateLSCDRFPMI ProgressProgress was made. CARM was stably locked
on RF only. DARM was RF only for a few moments
before I typed in a wrong number...
  
  11672   Thu Oct 8 13:13:20 2015 KojiUpdateLSCDRFPMI ProgressPlease clarify: I wonder if you were at
the zero offset for CARM and DARM or not.
I am 25% excited right now.
  
  11673   Thu Oct 8 14:14:50 2015 ericqUpdateLSCDRFPMI Progress


  
  11674   Thu Oct 8 16:48:23 2015 KojiUpdateLSCDRFPMI ProgressAwesome   
  11675   Thu Oct 8 21:35:49 2015 ranaUpdateLSCDRFPMI ProgressGive us a lockloss or other kind of time
series plot so we can bask in the glory.
  
  11676   Fri Oct 9 09:22:38 2015 ericqUpdateLSCDRFPMI Progress   oct8_allRF.pdf 
ELOG V3.1.3-