40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 231 of 344  Not logged in ELOG logo
ID Date Author Typeup Category Subject Text Attachments
  10375   Wed Aug 13 13:08:24 2014 ranaUpdateIMCCalculation for the input mode cleanerCan you please give us some more details
on how this design was decided upon? What
were the design considerations?
  
  10376   Wed Aug 13 16:12:55 2014 HarryUpdateGeneralFOL Layout DiagramPer Q's request, I've made up a diagram
of the complete FOL layout for general reference.
 FOLLayout2.png 
  10377   Wed Aug 13 17:37:43 2014 JenneUpdateGeneralGame plan   2014_Aug_13.pdf 
  10378   Wed Aug 13 19:23:09 2014 JenneUpdateLSCPSL, Aux laser mode hop checkThis afternoon Q helped me put in some
temporary PDs for checking for any mode hopping
behavior in our 3 main lasers. 
 ModeHopCheck_PSL_13Aug2014.pdfModeHopCheck_Xend_13Aug2014.pdfModeHopCheck_Yend_13Aug2014.pdf 
  10379   Wed Aug 13 22:01:57 2014 ranaUpdateIMCCalculation for the input mode cleanerNic,
Andres, and I discussed some more about the
MC WFS project today. We want
  
  10380   Wed Aug 13 23:08:17 2014 ranaUpdateIOOFSS box TFsAs EQ pointed out recently, we're injecting
into the FSS error point just after an RF
pi filter, but before the VGA. We wondered
 FSScomm.pdf 
  10382   Thu Aug 14 02:51:46 2014 JenneUpdateGeneralGame plan[Jenne, Rana]
* Decided that earlier mode hop scan
won't give us the information that we were
 Y_ALS_FINE_PHASE_OUT_noisy_13Aug2014.pdf 
  10383   Thu Aug 14 14:58:03 2014 JenneUpdateGeneralUpdated game plan   2014_Aug_14.pdf 
  10384   Thu Aug 14 15:10:47 2014 AndresUpdateIMCCalculation for the input mode cleaner

    

       
            
 SolutionForTheModeCleanerSetup00.pngSolutionForTheModeCleanerSetup11.pngPossibleSetupForModeCleaner.PNGalaModeSolution.zip 
  10385   Thu Aug 14 15:42:29 2014 KojiUpdateGeneralUpdated game plan - ALS
End PDH UGF improvement / post mixer
LPF investigation (with in 2 weeks)
  
  10386   Thu Aug 14 15:51:37 2014 JenneUpdateGeneralUpdated game plan

    

       
            
  
  10387   Thu Aug 14 18:02:11 2014 KojiUpdateGeneralUpdated game planGot the idea of ASC.
- Oplevs for PR2, PR3 => PR2 seems
OK. PR3 almost impossible. well
  
  10388   Thu Aug 14 18:05:05 2014 JenneUpdateGeneralUpdated game plan

    

       
            
  
  10389   Thu Aug 14 18:10:46 2014 HarryUpdateGeneralFiber Temperature Effects SetupPurpose
We want to characterize the sort
of response the fibers have to temperature
 tempAffectsSetup.zip 
  10390   Thu Aug 14 18:31:45 2014 ericqUpdateLSCLSC Modeling Update Based on the game plan, I have created
a slew of updated pretty plots about our
signals and loops. 
 7x 
  10393   Thu Aug 14 20:52:36 2014 ranaUpdateWikiViolin Mode table added to WikiMech
Resonance Wiki
I've updated the wiki by trawling
  
  10394   Thu Aug 14 22:16:02 2014 JenneUpdateSUSViolin Mode filters for ETMsThe instigator of this was that we were
seeing ring-ups of ETMs during our ALS locks
this evening.  We measured the ETMY
  
  10395   Thu Aug 14 22:31:12 2014 JenneUpdateLSCTRY gets mystery offsetI don't know why, but TRY has somehow gotten
a 0.3 count offset in the last hour. 
Rana and I are witnesses for each
 TRY_0pt3_offset.pdf 
  10398   Fri Aug 15 01:31:44 2014 JenneUpdateASCPOP QPD to ETMs model wiring completeI have added a few things to the ASS model,
and the ASC sub-block, so that we can send
POP QPD information down to the ETMs for
 ASC_newCARM.pngASSoverview_newCARM.pngASC_screen.png 
  10399   Fri Aug 15 02:05:55 2014 JenneUpdateLSCALS in-loop spectra Not sure why, but Rana and I didn't
see the super high Xarm noise with ALS that
we reported last night (elog
 ALS_XY_inloop_noise_14Aug2014_lowBeatFreq.pdf 
  10400   Fri Aug 15 13:29:31 2014 JenneUpdateGeneralGame plan: 15 Aug   40mToDoList.pdf 
  10401   Fri Aug 15 14:09:21 2014 JenneUpdateLSCTRY mystery offset goneAgain unknown, but about 6 hours ago (so
~8am) the offset disappeared. 
Here's a 1-day trend:
 TRY_0pt3_offset_gone.pdf 
  10402   Fri Aug 15 14:35:57 2014 ericqUpdateLSCTRY mystery offset goneOne question answered, but another raised.
The offset came from LSC-TRY switching to
the ETMY-QPD signal from ETMY-TRY (Hi gain
 TRYmystery.png 
  10403   Fri Aug 15 17:24:44 2014 HarryUpdateGeneralFiber Temp. Earlier today Q and I somewhat resurrected
my old PER measurement setup so I could run
the temperature characterization experiment.
  
  10404   Fri Aug 15 20:26:37 2014 ericqUpdateGeneralGame plan

    

       
            
  
  10405   Fri Aug 15 20:38:17 2014 ericqUpdateGeneralELOG dump A few things that I have neglected
to ELOG yet:

    
    scripts/offsets/LSCoffsets
  
  10407   Mon Aug 18 18:33:57 2014 ericqUpdateGreen LockingYarm Green PDHSo far today, I've been working with the
Y-end green PDH locking. Using a SR560 to
roll off the AG4395A output to take a loop
 yLoop.pdfcrap.pdf 
  10408   Tue Aug 19 01:01:36 2014 Jenne, RanaUpdateGreen LockingYarm Green PDH[ Rana, Jenne]
We remeasured the Yend PDH box.
When we first started, the green
 YPDH_OLG.pdfYPDH_noise.pdf 
  10409   Tue Aug 19 18:32:40 2014 ericqUpdateGreen LockingYarm Green PDHHeading to dinner, going to come back for
more green fun, but here's a quick update:
Xarm Peak-to-Peak of the PDH signal
  
  10410   Tue Aug 19 21:40:44 2014 AndresUpdateIMCNew Optical Setup for the IMCIMC
Calculation and Setup
I have been working in the calculation
 11x 
  10411   Tue Aug 19 23:11:15 2014 JenneUpdateGreen LockingYarm Green PDH 
 Here is a plot of last night's
data with both the control and the error
 ErrAndCtrlSpectra_VoltsPerRtHz.png 
  10412   Wed Aug 20 02:38:41 2014 JenneUpdateGreen LockingYarm Green PDH - requirement

    

       
            
 NoiseConsideration.pdf 
  10413   Wed Aug 20 04:09:21 2014 ericqUpdateGreen LockingXarm Green PDHI've made
a whole bunch of measurements on the Xarm
green situation.
TL;DRs:

 Xbodes.pdfXspectra.pdfscopeSweep.jpg 
  10414   Wed Aug 20 15:31:27 2014 ericqUpdateCOCArm Loss Investigations Continue [ericq, Gabriele] 
Summary: After today's meeting, Gabriele
and I looked into the arm loss situation,
  
  10415   Wed Aug 20 16:10:43 2014 ericqUpdateGreen LockingXarm Green PDHA MIST simulation tells me that the green
pdh horn-to-horn displacement is about 1.2nm,
or ~18kHz. I used this, along with the scope
 XspectraCombined.pdf 
  10416   Wed Aug 20 18:05:18 2014 JenneUpdateGreen LockingYarm Green PDH - requirement 
 I calibrated the control signal
from Volts to Hz using the rough PZT calibration
 YPDH_noise.pdf 
  10417   Wed Aug 20 21:09:16 2014 ericqUpdateGreen LockingXarm Green PDHI remeasured all of the noise spectra again
today, making sure the input attenuation
was as low as it could safely be. I also
 scopeSweep.jpgXspectra.pdfYspectra.pdfXYcomp.pdf 
  10419   Thu Aug 21 15:07:48 2014 SteveUpdateVACRGA scan at day 197 
 
 RGAscan@d197.png 
  10422   Fri Aug 22 03:55:45 2014 JenneUpdateLSCXarm PDH fine, Yarm PDH/ALS needs work[Rana, Jenne, EricQ]
We did several things tonight. 
First, a list (so I can remember them all),
 Xend_ErrorPointMeasurements.pdfDARM_ALSdiff_vs_sqrtInv.pdf 
  10423   Fri Aug 22 13:51:00 2014 JenneUpdateGeneralUpdated game plan   40mToDoList.pdf 
  10427   Fri Aug 22 18:05:02 2014 AndresUpdateIMCUpgrade of the IMC WFSs for the reflection Upgrade of IMC Reflection Optical
Setup
Nick and I upgrade the IMC.
We move both WFSs and placed them facing
 ModeCleanerUpgrade.PNG 
  10428   Mon Aug 25 09:56:21 2014 SteveUpdateIMC IMC WFSs upgrade 
 The Napa earth quake magnitude
6 did not have any effect on the suspensions.
 eq6Mnapa.png 
  10429   Mon Aug 25 15:49:44 2014 SteveUpdatePSLHEPA turned onThe PSL HEPA was off. It was turned on
and it is running at 30VAC now.
  
  10431   Tue Aug 26 23:46:55 2014 ericqUpdateIMCWFS tuneup I decided to see what I could do
with the new WFS setup. 
First, I adjusted the WFS digital
 newWFSmatrix.pdf 
  10432   Wed Aug 27 09:12:47 2014 KojiUpdateIMCWFS tuneupI'm sure that the 1~3Hz motion comes from
the mirror motion, but not 100% sure what
is causing 
  
  10433   Wed Aug 27 18:03:47 2014 ericqUpdateGreen LockinguPDH Box Checkup Quick post of plots and data; I'll
fill in more detail tonight. 
TL;DR: I pulled both green PDH boxes
 uPDH_X.JPGuPDH_Y.JPGupdhTFs.pdfupdhNoises.pdfuPDH_Aug27.zip 
  10434   Thu Aug 28 01:41:03 2014 ericqUpdateLSCPhase Tracker UGF normalizationWe want both the X and Y phase trackers
to have the same UGF, so that the X and Y
ALS signals are subject to the same phase
 UGFnorm.png 
  10435   Thu Aug 28 08:31:16 2014 SteveUpdateGeneralone good day   1goodDay.png1gooday.png 
  10436   Thu Aug 28 11:02:53 2014 SteveUpdateCalibration-RepairSR785 repairSN 46,795 of 2003 is back.  08281401.PDF 
  10437   Thu Aug 28 17:34:20 2014 ericqUpdateGreen LockinguPDH Box CheckupI had noticed in the past, that the digital
control signal monitor for the X end would
saturate well before the ADC should saturate
 TEK00006.PNG 
ELOG V3.1.3-