40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 22 of 341  Not logged in ELOG logo
IDup Date Author Type Category Subject Text Attachments
  1061   Mon Oct 20 20:50:09 2008 YoichiConfigurationPSLFSS board chip replacementA quick update.

I changed two AD797s on the FSS board to
  
  1062   Tue Oct 21 16:14:42 2008 steveUpdateGeneraldivergence of He Ne 1035PThe ITM oplevs laser diodes are noisy.
They will be replaced by JDS 1035P
SN T8093307 was measured with the beamscanner.
 1035p_divergence.png 
  1063   Tue Oct 21 16:17:45 2008 YoichiUpdatePSLAD797 Oscillation in the FSS boardI checked each op-amp's output in the FSS
board to see if any indication of slew-rate
saturation can be found.
  
  1064   Tue Oct 21 17:52:30 2008 ranaSummaryPSLFSS Photo: early OctoberThis is a photo of the FSS board before Yoichi
did his surgery - it was taken with the D40
in macro mode, sitting on the big Gorilla
 fss.jpg 
  1065   Tue Oct 21 18:19:42 2008 YoichiConfigurationComputersLISO and Eagle installedI installed LISO, a circuit simulation software,
into the control room linux machines.
I also installed a PCB CAD called Eagle to
 FSS_PC_Path.pdfAD829Stability.pngAD797Stability.pngFreqNoiseByAD829.png 
  1066   Wed Oct 22 09:42:41 2008 AlbertoDAQComputersc1iool0 rebooted and MC autolocker restartedThis morning I found the MC unlocked. The
MC-Down script didn't work because of network
problems in communicating with scipe7, a.k.a.
  
  1067   Wed Oct 22 12:37:47 2008 josephbUpdateComputersNetwork spreadsheetAttached in open office format as well as
excel format is spreadsheet containing all
the devices with IP addresses at the 40m.
 40m_network_10-15-08.ods40m_network_10-15-08.xls 
  1068   Wed Oct 22 16:22:53 2008 steveBureaucracySAFETYCaryn received safety trainingCaryn Polatchi has received 40m safety training
on Monday, Oct 20
  
  1069   Wed Oct 22 17:48:58 2008 YoichiUpdateGeneralLenses for focusing the optical lever laser (Re:divergence of He Ne 1035P)Steve had difficulty in finding lenses for
focusing the HeNe laser for the ITM op-lev.
Following his measurement of the beam divergence,
 BeamProfile.pngBeamPropagation.pngBeamPropagation.zip 
  1070   Wed Oct 22 20:50:30 2008 AlbertoOmnistructureComputersGPSToday I measured the GPS clock frequency at
the output of CLOCK_MON in a board on the
same crate where the c1iool0 computer is
  
  1071   Thu Oct 23 11:26:25 2008 steveBureaucracyVACoptosigma forks for vacuumNine short forks from OptoSigma were cleaned,
baked and measured by Bob T.
They passed the LIGO vac compatiblity test
  
  1072   Thu Oct 23 15:27:19 2008 AlbertoUpdateGeneralAbs lengthHere are the measurements I've got yesterday.
The plot shows the transmitted power after
the X arm while sweeping the frequency of
 TRX_aplot_03_04_05_together.png 
  1073   Thu Oct 23 18:23:47 2008 AlbertoUpdateGeneralAbs length[quote]Here are the measurements I've got
yesterday. The plot shows the transmitted
power after the X arm while sweeping the
 TRX_plot_06_07_08_together.png 
  1074   Thu Oct 23 18:27:04 2008 AlbertoUpdateGeneralAbs length[quote]Here are the measurements I've got
yesterday. The plot shows the transmitted
power after the X arm while sweeping the
 HOM_Frequencies.m 
  1075   Thu Oct 23 18:45:18 2008 AlbertoOmnistructureComputer Scripts / ProgramsPython code for GPIB devices developed for the Absl length experimentI wrote two Python scripts for my measurement
that can be also used/imitated by others:
sweepfrequency. py and HP8590.py. The first
 HP8590.pysweepfrequency.py 
  1076   Thu Oct 23 18:51:19 2008 AlbertoMetaphysicsComputerseLogI checked it and the latest version of the
elog software, the 2.7.5 (we have the 2.6.5)
has, among new nice features, the very good
  
  1078   Thu Oct 23 20:47:28 2008 peteConfigurationPSLFSS LO calibration for MEDMToday I took a quick series of measurements
to calibrate the FSS LO power measurement
in the MEDM.  This was done by using the
 fss_lo_calibration.png 
  1079   Thu Oct 23 21:52:27 2008 YoichiUpdatePSLFSS UGF now 450kHzI measured the open loop transfer function
of the FSS, for the first time after I mitigated
the oscillation.
 FSS_OPLTF.png 
  1080   Thu Oct 23 23:09:18 2008 YoichiUpdatePSLMC UGF is now 75kHzI measured three loop transfer functions of
the MC servo.
The blue curve in the first attachment is
 MC_Loop.pngOldAndNew.png 
  1081   Fri Oct 24 10:06:16 2008 YoichiConfigurationIOOMC gain and FSS gain changedFollowing the measurements of MC and FSS loop
gains, I modified mcup script to set the
MC VCO gain to 2dB (it was -4dB before).
  
  1082   Fri Oct 24 11:09:08 2008 steveUpdateSAFETYmore lexan plates under camerasThe MC2, MC3&1 and BSC-SUS cameras were repositioned
somewhat in the 
process of placing lexan disks under neat
  
  1083   Fri Oct 24 11:21:26 2008 peteConfigurationPSLFSS LO input calibrated in dBmBased on the measurements described in my
previous elog, I created a new calc record
in the file /cvs/cds/caltech/target/c1psl/psl.db
  
  1084   Fri Oct 24 11:42:48 2008 AlbertoUpdateGeneralAbs length: locking the X arm cavity in TEM01/10I went back to lock the arm cavity in either
TEM01 or TEM10 mode. Attached are the results.
We still have several resonances which we
 TRX_armTEM00-plot_09-10_together.png 
  1085   Fri Oct 24 15:05:13 2008 steveUpdateVACrga is out of orderThe old Dycor  RGA is out of order.
I'm getting ready to purchase an SRS instrument.
  
  1086   Fri Oct 24 17:21:13 2008 AlbertoUpdateGeneralAbs length: the right amount of beam clippingI found the reason why the peak at about 6.3MHz
appeared only on the TEM10 mode: the blade
was clipping the beam too much and it was
 24OCT08_levels_of_clipping_comparison.png 
  1087   Fri Oct 24 18:05:01 2008 AlbertoUpdateGeneralAbs length: transverse mode spacing measured for the X armThe ETMX suffers of astigmatism. I measured
the following frequencies for the higher
order modes:
 24OCT08_TEM10-01_comparison(file12-14).png 
  1088   Fri Oct 24 20:54:41 2008 ranaConfigurationComputerslinux2I have removed linux2 and its cables from
the control room and put it into 1Y3 along
with op340m.
  
  1089   Fri Oct 24 21:49:15 2008 JenneConfigurationPEMShort Seismometer CableBad news regarding the cable that goes between
the Guralp seismometer and the box that I've
been working on:  it's too short by about
  
  1090   Fri Oct 24 22:30:38 2008 Jenne,ranaUpdatePEMNoise from Guralp SeismometerAttached is a Power Spectrum of the noise
on the Vert1 channel of the Guralp seismometer.
 The noise is in the several hundreds of
 Vert1_Noise_24Oct2008.png 
  1091   Sun Oct 26 21:02:18 2008 ranaUpdateComputer Scripts / ProgramsSVN medm problemAs we've seen in the past a few times, there's
something wrong with the files in the [I]trunk/medm[/I]
area.
  
  1092   Mon Oct 27 10:02:16 2008 YoichiUpdateComputer Scripts / ProgramsSVN medm problemI tried to check out medm directory both from
my laptop and nodus.
I did not get the error.
  
  1093   Mon Oct 27 11:16:23 2008 AlbertoConfigurationIOOStochMon CalibrationI implemented the calibration for the four
channels of the StochMon in the ioo EPICS
database. Now the output of those channels,
  
  1094   Mon Oct 27 11:23:10 2008 steveUpdatePhotosnew Olympus camera with IR visionThe IR blocker was removed from our new Olympus
camera 
SP 570UZ camera.
 IRisin.JPG 
  1095   Mon Oct 27 14:48:27 2008 YoichiConfigurationPSLEO shutter installed to the reference cavityI'm now preparing for cavity ring down measurements
of the reference cavity.
An EOM for polarization rotation is installed
  
  1097   Tue Oct 28 11:10:18 2008 AlbertoUpdateLSCHigher Order Mode resonances in the X arms[quote]Recently we had been having some trouble
locking the full IFO in the [COLOR=green][I][FONT=Verdana]spring[/FONT][/I][/COLOR]
configuration (SRC on [COLOR=blue]+166[/COLOR]).
 HOM_resonances_Xarm.png 
  1098   Tue Oct 28 12:01:01 2008 josephbConfigurationComputerslinux2[quote]I have removed linux2 and its cables
from the control room and put it into 1Y3
along with op340m.
  
  1099   Wed Oct 29 12:23:04 2008 YoichiConfigurationPSLMZ alignment touched and the alarm level changedSince the MZ reflection is alarming all the
time, I tried to improve the MZ alignment
by touching the folding mirror.
  
  1100   Wed Oct 29 12:54:28 2008 JenneUpdatePEMCalibrated Guralp Noise compared to average ground motionHere is a calibrated noise plot of the Guralp
seismometer box.  This is the same noise
measured on Friday, measured at TP3 (just
 GuralpVert1Noise_mPERs_Ranger.png 
  1101   Thu Oct 30 11:07:25 2008 YoichiUpdateComputersWireless bridges arrivedFive wireless bridges for the GPIB-Ethernet
converters arrived.
One of them had a broken AC adapter. We have
  
  1102   Thu Oct 30 20:39:47 2008 carynConfigurationPEMtemperature sensor We attached the temperature sensor box to
the MC1/MC3 chamber with a C-clamp. We connected
the temp sensor to a 2nd box with a short
  
  1103   Fri Oct 31 08:52:19 2008 steveUpdateSUSETMY damping restoredETMY watchdogs were tripped yesterday morning
also. This is a problem that existed some
months ago.(?)
 etmy2d.jpg 
  1104   Sun Nov 2 20:21:58 2008 ranaConfigurationloreHP 5550dtn (Grazia) set up on allegraI set up printing to grazia from allegra.
The CUPS interface was not as straightforward
as Tobin had made it seem in the Wiki. I
  
  1105   Sun Nov 2 20:44:58 2008 ranaUpdateASSWiener Filter performance over 5 hoursI took one 2 hour stretch of data to calculate
a MISO Wiener filter to subtract the Ranger
seismometer
 f.pngf1.png 
  1106   Sun Nov 2 21:37:22 2008 ranaUpdatePEMRanger recoveryThe ranger signal has been bad since around
11 AM on Oct 25 (last Saturday). There are
no elog
  
  1107   Mon Nov 3 09:59:47 2008 steveUpdatePSLPSL HEPAs turned onThe psl [COLOR=chocolate]enclosure[/COLOR]
HEPAs were tuned on.
  
  1108   Mon Nov 3 19:12:27 2008 albertoUpdateGeneralTransverse mode spacing measurement for the X armI know a lot of expectations have been building
up on these days in the scientific community
at the 40m towards a conclusive elog entry
 2008-11-02_summarizingplot.png 
  1109   Mon Nov 3 19:18:47 2008 AlbertoConfigurationGeneralnew elogPhil Ehrens kindly poured our elog's content
in a CD that now is here at the 40m.
I've been trying to install the 2.7.5 version
  
  1110   Mon Nov 3 21:38:32 2008 YoichiConfigurationGeneralnew elog[quote]I tried to recompile the elog from
the source code but the way gcc is called
must be wrong because I get this error message:
  
  1111   Mon Nov 3 22:35:40 2008 ranaUpdateASSWiener Filter performance over 5 hours[FONT=Comic Sans MS]To speed up the Wiener
filter work I defined a 256 Hz version of
the original 16kHz IOO-MC_L signal. The
 DAQ.pdf 
  1112   Tue Nov 4 00:47:53 2008 ranaUpdateASSWiener Filter performance over 5 hoursSame as before, but now with a working Ranger
seismometer.
 f2.pngf.png 
ELOG V3.1.3-