40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 229 of 341  Not logged in ELOG logo
ID Date Author Type Category Subject Text Attachments
  5655   Wed Oct 12 08:43:30 2011 steveUpdateSUSITMX oplev improved a bit Atm2 is before optical path adjustment.
The idea was to remove possible clipping
in vacuum.
 ITMXoplev.pngITMXoplevservo_ON.png 
  5654   Wed Oct 12 00:35:42 2011 kiwamuUpdateLSCTRY path realignedThe
TRY (TRansmitted light from Y arm ) path
was a bit realigned because there had been
  
  5653   Tue Oct 11 21:23:51 2011 JenneUpdateLSCArm absl lengths

    

       
            
  
  5652   Tue Oct 11 19:11:25 2011 kiwamuUpdateLSCRe: BS actuator reponse at low frequency : measuredI think
the precision due to the loop gain uncertainty
  
  5651   Tue Oct 11 17:32:05 2011 jamieHowToEnvironment40m google maps linkHere's another useful link:
http://maps.google.com/maps?q=34.13928,-118.123756
  
  5650   Tue Oct 11 15:19:17 2011 ranaHowToEnvironment40m mapThe Kinemetrics dudes are  40mLabMap.png40mLabMap.jpg 
  5649   Tue Oct 11 15:14:50 2011 ranaUpdateLSCBS actuator reponse at low frequency : measured

    

       
            
  
  5648   Tue Oct 11 03:35:16 2011 kiwamuUpdateLSCBS actuator reponse at low frequency : measuredThe response
of the BS actuator in a low frequency regime
 BSactuator.png 
  5647   Tue Oct 11 00:59:55 2011 SureshUpdateIOOPreliminary locking of WFS loops[Kiwamu, Koji, Suresh]
After correcting several errors in
the WFS loops, we turned them on today and
 6x 
  5646   Mon Oct 10 18:53:04 2011 KatrinUpdateGreen LockingMirrors whose angle of incidence is not 45The angle of incidence of light is for
some mirrors on the YARM end table different
from 45° even though the mirrors are
  
  5645   Mon Oct 10 16:32:18 2011 steveUpdateSUSUL sensor of ETMY is recovered I lost UL osem voltage this morning
when I was checking the actual connection
at rack ETMY
 ETMY_UL.pngETMY_OSEM_UL.pngnoisyETMY_UL.png 
  5644   Mon Oct 10 15:41:56 2011 KojiUpdatePSLPMC aligned[Koji Suresh]
The steering mirrors for PMC were
aligned. The transmission went up from 0.779
  
  5643   Mon Oct 10 13:52:04 2011 kiwamuUpdateLSCRE: First attempt to estimate mode matching efficiency using interferometer

    

       
            
  
  5642   Mon Oct 10 12:14:00 2011 MirkoUpdateComputer Scripts / ProgramsIMC simulations[Mirko, Kiwamu]
I tried to answer two questions regarding
the IMC:
 opticke_xaxis.pngDC_power.pngDC_power_B.pngIMC_simulation.zip 
  5641   Mon Oct 10 10:14:43 2011 ranaUpdateLSClength fluctuations in SRCL How does it make sense that the motion
at 0.1 Hz of PRC is 10x larger than MICH?
  
  5640   Mon Oct 10 00:01:26 2011 KojiUpdateLSCFirst attempt to estimate mode matching efficiency using interferometer"^2"s are missing in the second
equation, but the calculation results seem
correct.
  
  5639   Sun Oct 9 17:13:46 2011 kiwamuUpdateLSCFirst attempt to estimate mode matching efficiency using interferometerThe efficiency
of the mode matching (MM) to PRC (Power-Recycling
 mm_reflection.png 
  5638   Sat Oct 8 04:41:07 2011 kiwamuUpdateLSClength fluctuations in SRCLFor a comparison,
the length fluctuation of Signal-Recycled
 length_noise.png 
  5637   Sat Oct 8 00:44:42 2011 kiwamuUpdateLSCcalibration of SRM actuatorThe AC response
of the SRM actuator has been calibrated.
 actuators.png 
  5636   Fri Oct 7 23:23:05 2011 kiwamuUpdateSUSSRM oplev was oscillatingThe SRM oplevs were found to be oscillating
because of a small phase margin.
I reduced the gains to the half of
  
  5635   Fri Oct 7 22:48:26 2011 SureshUpdateIOOMC2 Trans QPD spot size and incident power decreasedAfter centering the spot on the MC2, I
started to adjust the spot position on MC_TRANS_QPD
to center the beam on it.  I noticed
  
  5634   Fri Oct 7 22:41:05 2011 KojiConfigurationGeneralScript backup fixed Script backup regularly runs on
op340m by crontab,
  
  5633   Fri Oct 7 22:31:53 2011 kiwamuUpdateSUSnoisy ULSEN on ETMYYesterday
Koji was claiming that the rms monitor of
ULSEN on ETMY didn't well go down.
 ETMY_OSEMs.png 
  5632   Fri Oct 7 19:06:46 2011 SureshUpdateIOOMC spot positions: checked and corrected.Koji and Kiwamu had adjusted the MC beam
axis slightly such that we can couple the
MC output into the Y-arm without exceeding
  
  5631   Fri Oct 7 17:35:26 2011 KatrinUpdateGreen LockingPower on green YARM tableAfter all realignment is finished, here
are the powers at several positions:
 
 DSC_3496_power.JPG 
  5630   Fri Oct 7 14:04:48 2011 steveUpdateSUSHe/Ne intensity noise effect on oplevsThe SRM bounce peak 18.33 Hz. Suresh helped
me to retune filter through Foton, but we
failed to remove it.
 7x 
  5629   Fri Oct 7 11:53:47 2011 KojiUpdateLSCDRMI locked and some plans- REFL165 PD to be fixed (shows constant
high voltage at the DC out)
- Make POP22/110 PD
  
  5628   Fri Oct 7 11:45:24 2011 KojiSummaryLSCPOY11 installed, 55MHz PD at POY removedPOY11
PD was installed last night. The lock of
the Y arm was confirmed with the POY11I signal.
  
  5627   Fri Oct 7 04:42:24 2011 kiwamuUpdateLSCDRMI locked and some plansDRMI has been
locked using the same RFPD selection as the
  
  5626   Thu Oct 6 15:40:57 2011 JenneUpdateLSCArm absl length data taken[Katrin, Jenne]
We took the data for the new absolute
length measurement of both arms, after the
  
  5625   Thu Oct 6 15:37:26 2011 JenneUpdateGreen LockingY-green Mech Shutter Button[Katrin, Jenne]
We were poking around and tried to
make a button for the Y-green shutter, just
  
  5624   Thu Oct 6 05:18:20 2011 kiwamuUpdateLSCNoise in AS55 was from clipping : fixed It turned
out the noise in AS55 was due to a clipping. 
 outofloop.png 
  5623   Wed Oct 5 18:31:02 2011 KatrinUpdateGreen LockingExchanged mirror on YARM tableOn the Green YARM end table the second
mirror behind the laser has been exchanged.
Reason: The light is impinging on
  
  5622   Wed Oct 5 17:08:49 2011 steveUpdateSUSBS oplev spectraKiwamu and Steve,
The He/Ne oplev shows no coherece
so relative intensity noise is not limiting
 BSoplservON2.png 
  5621   Wed Oct 5 14:18:09 2011 kiwamuUpdateCDSsome DAQ channel lost in c1sus : fb, c1sus and c1pem restartedI
found again the ini files had been refreshed.
I ran the activateDQ.py script (
  
  5620   Wed Oct 5 11:33:25 2011 steveUpdateSUSPRM and BS oplev laser replaced 
JDSU 1103P died after 4 years of
service. It was replaced with new identical
  
  5619   Tue Oct 4 20:34:20 2011 KatrinUpdateGreen Locking7kHz Peak in servo input YARM[Kiwamu, Katrin]
As reported earlier an oscillation
around 7kHz is an the PDH error signal. The
 servoinput.pngservoinput2.png 
  5618   Tue Oct 4 19:31:17 2011 kiwamuUpdateSUSPRM and BS oplev laser diedThe
He-Ne laser which has been used for the PRM
and BS oplevs were found to be dead. 
 oplevs.png 
  5617   Tue Oct 4 19:06:46 2011 KojiUpdateIOOclosed the shutter before the MCFinished the work at 6:30
MC REFL (INLOCK): 0.50-0.52
MC REFL (UNLOCK): 6.9
  
  5616   Tue Oct 4 16:58:45 2011 SureshUpdatePSLAM / PM ratioCorrection:        Koji noted that Mirko
actually reports a PM modulation index of
0.17 for the 11 MHz sideband (
  
  5615   Tue Oct 4 16:10:45 2011 SureshUpdateComputer Scripts / ProgramsMC was not dampingThe MC was not damping earlier this morning
around 11:45AM.  The reason was that
the INMATRIX on all the three MC1, 2 and
  
  5614   Tue Oct 4 15:57:30 2011 SureshUpdateIOOMC Trans channels are digital 0
I thought this problem might be arising
because the MC2_TRANS QPD signals are not
being passed from the c1mcs to c1ioo models
  
  5613   Tue Oct 4 15:43:10 2011 KojiUpdateIOOclosed the shutter before the MCThe shutter before the MC was closed at
3:30 as I started working on the RFAM.
MC REFL (INLOCK): 0.6~0.7
  
  5612   Tue Oct 4 14:41:47 2011 JenneUpdateIOOMC Trans channels are digital 0I relocked the PMC (why is it unlocking
so much lately??), and then noticed that
even though the MC is locked, MC Trans Sum,
  
  5611   Tue Oct 4 10:35:08 2011 MirkoUpdateCDSc1lsc and c1sus running again[Alex, Mirko]
Alex fixed the computers this morning.
It was in fact a dolphin problem:
  
  5610   Tue Oct 4 07:51:36 2011 steveUpdateCDSc1lsc and c1sus are still down 
 c1lsc and c1sus are still down.
Only ETMX and ETMY are damped
  
  5609   Mon Oct 3 23:52:49 2011 kiwamuUpdateCDSsome more tests for the Dolphin [Koji / Kiwamu]
 We
did several tests to figure out what could
  
  5608   Mon Oct 3 21:20:30 2011 JenneUpdateCDSc1lsc and c1sus didn't run[Jenne, Mirko, Kiwamu, Koji, and Jamie
by phone]
We just got off the phone with Jamie. 
  
  5607   Mon Oct 3 20:47:51 2011 kiwamuUpdateCDSc1lsc and c1sus didn't run[Mirko / Jenne / Kiwamu]
Just a quick update. All the realtime
processes on the c1lsc and c1sus
  
  5606   Mon Oct 3 20:02:59 2011 SureshUpdatePSLAM / PM ratio[Koji, Suresh]
In the previous measurement, the
PDA 255 had most probably saturated at DC,
  
ELOG V3.1.3-