ID |
Date |
Author |
Type |
Category |
Subject |
2081
|
Mon Oct 12 17:14:39 2009 |
rob | Update | Locking | stability |
Last night, 2+ hour lock, probably broken by me driving too hard (DARM_EXC). |
2092
|
Wed Oct 14 16:59:37 2009 |
rob | Update | Locking | daytime locking |
The IFO can now be locked during the daytime. Well, it's locked now. |
2093
|
Wed Oct 14 23:02:41 2009 |
rana | Update | Locking | daytime locking |
This is huge. Five hours of lock only interrupted by intentional break from transfer function abuse. |
2097
|
Thu Oct 15 09:23:07 2009 |
steve | Summary | Locking | never had it so good |
Awesome 5 hrs of locking Rob! |
2100
|
Thu Oct 15 17:12:00 2009 |
rana | Summary | Locking | never had it so good |
|
2141
|
Mon Oct 26 03:57:06 2009 |
rob | Update | Locking | bad |
Lock acquisition has gone bad tonight.
The initial stage works fine, up through handing off control of CARM to MCL. However, when increasing the AO path (analog gain), there are large DC shifts in the C1:IOO-MC_F signal. Eventually this causes the pockels cell in the FSS loop to saturate, and lock is lost. |
2148
|
Tue Oct 27 01:45:02 2009 |
rob | Update | Locking | MZ |
Quote: | Tonight we also encountered a large peak in the frequency noise around 485 Hz. Changing the MZ lock point (the spot in the PZT range) solved this. |
This again tonight.
It hindered the initial acquisition, and made the DD signal handoff fail repeatedly. |
2152
|
Tue Oct 27 18:19:14 2009 |
rob | Update | Locking | bad |
Quote: |
Lock acquisition has gone bad tonight.
The initial stage works fine, up through handing off control of CARM to MCL. However, when increasing the AO path (analog gain), there are large DC shifts in the C1:IOO-MC_F signal. Eventually this causes the pockels cell in the FSS loop to saturate, and lock is lost.
|
This problem has disappeared. I don't know what it was.
The first plot shows one of the symptoms. The second plot is a similar section taken from a more normal acquisition sequence the night before.
All is not perfect, however, as now the handoff to RF CARM is not working. |
2154
|
Wed Oct 28 05:02:28 2009 |
rob | Update | Locking | back |
LockAcq is back on track, with the full script working well. Measurements in progress. |
2162
|
Thu Oct 29 21:51:07 2009 |
rob | Update | Locking | bad |
Quote: |
Quote: |
Lock acquisition has gone bad tonight.
The initial stage works fine, up through handing off control of CARM to MCL. However, when increasing the AO path (analog gain), there are large DC shifts in the C1:IOO-MC_F signal. Eventually this causes the pockels cell in the FSS loop to saturate, and lock is lost.
|
This problem has disappeared. I don't know what it was.
The first plot shows one of the symptoms. The second plot is a similar section taken from a more normal acquisition sequence the night before.
All is not perfect, however, as now the handoff to RF CARM is not working.
|
The problem has returned. I still don't know what it is, but it's making me angry. |
2163
|
Fri Oct 30 04:41:37 2009 |
rob | Update | Locking | working again |
I never actually figured out exactly what was wrong in entry 2162, but I managed to circumvent by changing the time sequence of events in the up script, moving the big gain increases in the common mode servo to the end of the script. So the IFO can be locked again. |
2271
|
Sun Nov 15 18:42:10 2009 |
Alberto | Update | Locking | Interferometer fully locked for 3331 seconds |
This afternoon, I tried to lock the interferometer again after a few days.
After a couple of failed attempts, and relocks of the MZ, the interferometer stayed locked continuously for about 50 minutes, with arm power of about 92.
I just wanted to check the status of the interferometer so I didn't do any particular measurement in the meantime. |
2325
|
Wed Nov 25 03:05:15 2009 |
rob | Update | Locking | Measured MC length |
Quote: |
What I meant was the VCO driver, not the FSS box.
As for the frequency, all written numbers were the Marconi displays.
The number on the frequency counter was also recorded, and so will be added to the previous entry shortly...
Quote: |
I propose that from now on, we indicate in the elog what frequencies we're referring to. In this case, I guess its the front panel readback and not the frequency counter -- what is the frequency counter readback? And is everything still locked to the 10 MHz from the GPS locked Rubidium clock?
Plus, what FSS Box? The TTFSS servo box? Or the VCO driver? As far as I know, the RC trans PD doesn't go through the FSS boxes, and so its a real change. I guess that a bad contact in the FSS could have made a huge locking offset.
|
|
Locking has gone sour. The CARM to MCL handoff, which is fairly early in the full procedure and usally robust, is failing reliably.
As soon as the SUS-MC2_MCL gain is reduced, lock is broken. There appears to be an instability around 10Hz. Not sure if it's related. |
2332
|
Wed Nov 25 14:29:08 2009 |
rob | Update | Locking | Measured MC length--FSS trend |
Quote: |
Quote: |
What I meant was the VCO driver, not the FSS box.
As for the frequency, all written numbers were the Marconi displays.
The number on the frequency counter was also recorded, and so will be added to the previous entry shortly...
Quote: |
I propose that from now on, we indicate in the elog what frequencies we're referring to. In this case, I guess its the front panel readback and not the frequency counter -- what is the frequency counter readback? And is everything still locked to the 10 MHz from the GPS locked Rubidium clock?
Plus, what FSS Box? The TTFSS servo box? Or the VCO driver? As far as I know, the RC trans PD doesn't go through the FSS boxes, and so its a real change. I guess that a bad contact in the FSS could have made a huge locking offset.
|
|
Locking has gone sour. The CARM to MCL handoff, which is fairly early in the full procedure and usally robust, is failing reliably.
As soon as the SUS-MC2_MCL gain is reduced, lock is broken. There appears to be an instability around 10Hz. Not sure if it's related.
|
Five day minute trend. FAST_F doesn't appear to have gone crazy. |
2333
|
Wed Nov 25 15:38:08 2009 |
rob | Update | Locking | Measured MC length |
Quote: |
Quote: |
What I meant was the VCO driver, not the FSS box.
As for the frequency, all written numbers were the Marconi displays.
The number on the frequency counter was also recorded, and so will be added to the previous entry shortly...
Quote: |
I propose that from now on, we indicate in the elog what frequencies we're referring to. In this case, I guess its the front panel readback and not the frequency counter -- what is the frequency counter readback? And is everything still locked to the 10 MHz from the GPS locked Rubidium clock?
Plus, what FSS Box? The TTFSS servo box? Or the VCO driver? As far as I know, the RC trans PD doesn't go through the FSS boxes, and so its a real change. I guess that a bad contact in the FSS could have made a huge locking offset.
|
|
Locking has gone sour. The CARM to MCL handoff, which is fairly early in the full procedure and usally robust, is failing reliably.
As soon as the SUS-MC2_MCL gain is reduced, lock is broken. There appears to be an instability around 10Hz. Not sure if it's related.
|
Whatever the locking problem was, the power of magical thinking has forced it to retreat for now. The IFO is currently locked, having completed the full up script. One more thing for which to be thankful. |
3072
|
Sat Jun 12 19:41:04 2010 |
Alberto | Update | Locking | 40m Upgrade Optickle Model |
I wrote down the settings according to which I tuned the optickle model of the 40m Upgrade.
Basically I set it so that:
- PRC alone anti-resonant for the carrier and resonant for both sidebands
- SRC alone resonant for the carrier and resonant for the f2 sideband
In this way when the carrier becomes resonant in the arms we have:
- carrier resonant in PRC and anti-resonant in SRC
- f1 resonant in PRC and non resonant in SRC
- f2 resonant in SRC
The DARM offset for DC readout is optional, and doesn't change those conditions.
I also plotted the carrier and the sideband's circulating power for both recycling cavities.
I'm attaching a file containing more detailed explanations of what I said above. It also contains the plots of field powers, and transfer functions from DARM to the dark port. I think they don't look quite right. There seems to be something wrong.
Valera thought of fixing the problem, removing the 180 degree offset on the SRM, which is what makes the sideband rather than the carrier resonant in SRC. In his model the carrier becomes resonant and the sideband anti-resonant. I don't think that is correct.
The resonant-carrier case is also included in the attachment (the plots with SRMoff=0 deg). In the plots the DARM offset is always zero.
I'm not sure why the settings are not producing the expected transfer functions. |
3074
|
Sun Jun 13 08:28:44 2010 |
valera | Update | Locking | 40m Upgrade Optickle Model |
In my calculation of the digital filters of the optical transfer functions the carrier light is resonant in coupled cavities and the sidebands are resonant in recycling cavities (provided that macroscopic lengths are chosen correctly which I assumed). |
3075
|
Mon Jun 14 07:57:07 2010 |
alberto | Update | Locking | 40m Upgrade Optickle Model |
Quote: |
In my calculation of the digital filters of the optical transfer functions the carrier light is resonant in coupled cavities and the sidebands are resonant in recycling cavities (provided that macroscopic lengths are chosen correctly which I assumed).
|
Carrier and SB (f2) shouldn't be resonant at the same time in the SRC-arms coupled cavity. No additional filtering of the GW signal is wanted.
The SRC macroscopic length is chosen to be = c / f2 - rather than = [ (n+1/2) c / (2*f2) ] - accordingly to that purpose. |
3079
|
Tue Jun 15 21:28:44 2010 |
alberto | Update | Locking | 40m Upgrade Optickle Model |
Quote: |
Quote: |
In my calculation of the digital filters of the optical transfer functions the carrier light is resonant in coupled cavities and the sidebands are resonant in recycling cavities (provided that macroscopic lengths are chosen correctly which I assumed).
|
Carrier and SB (f2) shouldn't be resonant at the same time in the SRC-arms coupled cavity. No additional filtering of the GW signal is wanted.
The SRC macroscopic length is chosen to be = c / f2 - rather than = [ (n+1/2) c / (2*f2) ] - accordingly to that purpose.
|
I calculated the frequency of the double cavity pole for the 40m SRC-arm coupled cavity.
w_cc = (1 + r_srm)/(1- r_srm) * w_c
where w_c is the arm cavity pole angular frequency [w_c = w_fsr * (1-r_itm * r_etm)/sqrt(r_itm*r_etm) ]
I found the pole at about 160KHz. This number coincides with what I got earlier with my optickle model configured and tuned as I said in my previous entry. See attachments for plots of transfer functions with 0 and 10pm DARM offsets, respectively.
I think the resonance at about 20 Hz that you can see in the case with non-zero DARM offset, is due to radiation pressure. Koji suggested that I could check the hypothesis by changing either the mirrors' masses or the input power to the interferometer. When I did it frequency and qualty factor of the resonance changed, as you would expect for a radiation pressure effect.
Independently, Jan also calculated the pole frequency of the transfer function DARM / ASQ2 as we would expect it for the SRC-coupled cavity. He also found the pole at about 160KHz. I'm attaching the plot with the transfer function he calculated.
He also said that the little bump at the pole frequency is OK considering that our signal recycling cavity is not much shorter than the arms.
This gave me more confidence about my optickle model of the 40m. This is quite comforting since I used that model other times in the past to calculate several things (i.e. effects of higher unwanted harmonics from the oscillator, or, recently, the power at the ports due to the SB resonating in the arms).
I don't know anymore what Valera said that wasn't right.
Also, as he said, he set it for the carrier to be resonant in the SRC-arms couple cavity. But that is not our case. |
3750
|
Thu Oct 21 05:51:10 2010 |
kiwamu | Update | Locking | no green beat note |
Still I didn't see any beat note signals..
With a help from Suresh, Yuta and Rana, I tried searching for the green beat note by changing the temperature of the X end NPRO.
The noise level after it goes through an RF amplifier (G=23dB) was about -70dBm at 50MHz.
This noise may cover the beat note signal.
I am going to post some details later. |
3754
|
Thu Oct 21 15:59:28 2010 |
kiwamu | Update | Locking | no green beat note : details |
Last night I tried searching for a beat note signal with two different PD trans impedance gains.
Although I didn't find a beat note signal.
- (1. trans impedance gain = 2400)
I started with a trans impedance resistance of R=2.4k, which is 10 times bigger resistance than the original.
The total PD gain should be about 960 [V/W] theoretically if we assume the responsibility of the PD is 0.4 [A/W].
Then I checked the bandwidth of the RFPD using Jenne laser.
The bandwidth was about 30MHz, which is 3 times narrower than the original. And it agrees with our expectation.
As Koji and I mentioned at the last weekly meeting, the cut off frequency of an RFPD follows inverse square root of the trans impedance resistance R.

where C is a capacitance of the photo diode. (See this)
I was expecting the signal level of -50 dBm / rtHz with a 23dB RF amplifier, assuming the line width of the signal is 10kHz.
- (2. trans impedance gain = 240)
I also tried it with the original trans impedance gain (see this entry).
R = 240 [Ohm]
G = 96 [V/W]
BW = 100 [MHz] (I didn't measure it in this time)
expected signal level = -70 dBm/rtHz
Quote: |
Still I didn't see any beat note signals..
|
|
3763
|
Fri Oct 22 18:15:21 2010 |
kiwamu | Update | Locking | Green era: found a green beat note finally |
finally we found it !
 |
3766
|
Fri Oct 22 21:28:27 2010 |
Aidan | Update | Locking | Green era: found a green beat note finally |
Nice work!
Quote: |
finally we found it !

|
|
3771
|
Sun Oct 24 18:06:35 2010 |
kiwamu | Summary | Locking | setup for green beat |

(notes on signal level)
The signal level of the observed peak was -48dBm.
However I was expecting it is like -28dBm with some ideal assumptions.
There may be a 20dB unknown loss which sounds big to me.
The expectation was calculated by using the following simple math.
SIGNAL = A x Z x G_RF x sqrt(P1 / 2) x sqrt (P2 / 2)
where A is the responsibility of the PD and Z is the trans impedance gain. G_RF is a gain of the RF amplifier.
The laser powers of green beams, P1 and P2, are divided by 2 due to a beam splitter.
I was assuming the parameters are like:
A = 0.39 [A/W] (assuming 90% quantum efficiency at 532nm)
Z = 240 [V/A]
P1 = 17 uW (measured by Newport power meter)
P2 = 30 uW (measured by Newport power meter)
G_RF = 23 dB
|
3774
|
Mon Oct 25 02:14:38 2010 |
Koji | Summary | Locking | setup for green beat |
- What is the actual photocurrent for the beam1 and beam2? We don't care how much power do you have before the BS, but care how much current do you have on the PD.
- How much is the visibility? There is mismatching of the beams. i.e. The beam diameter looked quite different. Also the beams are not TEM00 but have fringes probably comes from the TT mirrors. You maybe able to measure the visibility by the DC output, making the beat freq go through df=0 slowly.
- What is the measured gain of the RF amp? Does it include the voltage division by the output/input impedance?
---------------------
The signal level of the observed peak was -48dBm.
However I was expecting it is like -28dBm with some ideal assumptions.
There may be a 20dB unknown loss which sounds big to me.
I was assuming the parameters are like:
A = 0.39 [A/W] (assuming 90% quantum efficiency at 532nm)
Z = 240 [V/A]
P1 = 17 uW (measured by Newport power meter)
P2 = 30 uW (measured by Newport power meter)
G_RF = 23 dB |
3800
|
Wed Oct 27 21:33:42 2010 |
Suresh | Update | Locking | Green from the far end re-obtained |
The mirror which was moved during the mode matching of PSL light to the MC (ref elog #3791) has been repositioned. We once again have the green light from the NPRO on the X (south) arm available on the PSL table.
This light was supposed to be collimated by the two plano convex lenses (f=200mm and f=50mm ref to elog #3771) but it was converging. So I moved the f=50mm lens backwards to make the beam collimated. I checked the beam collimation by introducing an Al coated mirror infront of th PD and diverting the beam temporarily in a free direction. I could then check the collinearity and collimation of both the green beams over a meter. After alignment the mirror was removed and the light is now incident on the PD once again. We can now proceed to look for green beats.
The power from the PSL NPRO was attenuated for the MC locking work of yesterday. It has now been increased to the maximum by rotating the Half Wave Plate (HWP). The power after the PSL is now about 450mW (500mW - 10% picked off for the doubling).
|
3804
|
Thu Oct 28 03:21:35 2010 |
Suresh | Update | Locking | Aligned the MC2 transmission photodiode |
Yuta and Suresh
The MC2 transmission is seen on the QPD
Once the laser was locked to the cavity, and the PMC was able to follow the laser (ref: elogs by Yuta and Rana today) we had a steady TEMoo mode in the MC. This gave us sufficient transmission through MC2 to be easily visible with an IR viewer and we were able to guide the beam on to the QPD. The beam however seemed to over fill the QPD, a lens (f=180mm) was placed before the beam folding mirror and the spot sized reduced. The the QPD was found to be not fixed to the table and this was also recitified. The signal level is still low: total signal is just about 7 DAQ steps amounting to about 5mV. Tomorrow we plan to work on the alignment of the PSL and MC and thus increase this signal.
A new channel to observe the length variations in the MC.
A long BNC cable was laid from the MC locking electronics next (southwards) to the PSL table to the DAQ cards picking up the signals from the PRM OSEMS. This is to pick up one of the MC locking signals and collect it on a DAQ channel. However as there are no spare DAQ channels currently available one of the PRM OSEM (UL and LL) photodiode channels was unplugged and replaced with the signal from the long BNC cable. For identifying the correct DAQ channel we put in a 2 Vpp 10Hz signal with a function generator into this BNC. Tow signals can be picked up in this fashion and they are available on PRM_LLSEN_IN1 and PRM_ULSEN_IN1. We plan to use this for improving the alignment of the MC tomorrow.
The algorithm for this alignment is that if the beam from the PSL is not centered on the MC1 then tilting MC1 would result in a change in the length of the cavity as seen by the light. Using this as feedback the spot could be precisely centered on the MC1 and then the MC alignment could be completed by moving MC2 and MC3 to reobtain TEM_oo within the cavity. |
3843
|
Tue Nov 2 00:17:01 2010 |
Suresh | Configuration | Locking | Temporary changes to the Video Mux |
Fiber coupling 1064 nm light at the end of X arm
This is 'work in progress'. The attempt is to bring a few milliwatts of the 1064 nm light from the NPRO at the end of the South(X) Arm to the PSL table through an single mode optical fiber. This would enable us to tune the two NPRO's to be less than 15 MHz apart by looking at their beat frequency before doubling. Because we have a 1GHz bandwidth PD at 1064 nm, while the photodiode for green has a BW of about 30MHz.
A PBS (P-type) cube has been introduced into the beam of the X arm NPRO (between the lamda/2 plate and the input lens of the doubling crystal). By rotating the face of the PBS slightly away from normal incidence, I have diverted away 1.5mW of the 1064 light for coupling into the fiber. The beam has shifted slightly because of this and the green beam from the south arm has to be realigned to reach the PSL table.
A single mode fiber (Thorlabs SM980-5.8-125), which was already laid half way, has been extended all the way to the PSL table. It runs along the South arm in the cable tray.
A pair of mirrors have been arranged in a zig-zag to steer the beam into a fiber coupler. There was some hope that this coupler had been aligned at some point in the past and that attaching a fiber might result in some transmission. But this is not the case and fiber coupler needs to be readjusted.
In order to see the light transmitted through the fiber, a camera has been set up on the PSL table. Its output has been routed into the 'Ref Cavity reflected' video signal. A video cable running from the ETMX to the Video-MUX used to be connected to the input channel 9 of the Video MUX. This has now been shifted to output channel 25 of the MUX and disconnected from the camera at the ETMX. The 'Ref Cav Refl.' video signal has been routed to the output channel 25. The camera looking at the fiber output can now be seen on a local monitor at the end of the X arm and on the video monitor in the control room.
With the fiber disconnected, the 1064 nm beam was steered into the fiber coupler and its transmission maximised by observing with an IR viewer. The fiber was then connected and then the transmission at the PSL table was sought. There was no transmission seen after a searching around this region for a few mins.
The plan is to purchase a Visual fault locator which would enable us to quickly get a rough alignment of the fiber coupler. A local vendor is listed as a distributor for this product from JDSU. Contact info:
DuVac Electronics (EDGE)
Tel: 626-796-3291
Email: jack@duvac.com
1759 E Colorado Blvd
Pasadena, CA 91106
|
3859
|
Thu Nov 4 03:13:46 2010 |
Suresh | Update | Locking | Fibre coupling 1064nm light at the south-end table |
[Kiwamu, Suresh]
We decided to use the 1064nm beam reflected from the Y1-1037-45-P mirror after the collimation lens following the doubling crystal for coupling into the optical fiber (ref 3843 and 3847 ).
We replaced a beam dump which was blocking this beam with a Y1-1037-45-P mirror and directed the beam into the fiber coupler with another Y1-1037-45-P. The power in this beam was about 1W. This has been stepped down to 10mW by introducing a reflective ND filter of OD=2. The reflected power has been dumped into a blade-stack beam dump.
Steve has ordered the The Visual Fault Locator from Fluke. It is expected to arrive within a day or two.
|
3865
|
Thu Nov 4 19:00:57 2010 |
Suresh | Update | Locking | Fibre coupling 1064nm light at the south-end table |
The Fluke Visual Fault locator (Visifault) arrived and I used it to couple 1064nm light into the single mode fibre at the south-end-table.
Procedure used:
When the output end of the fiber is plugged into the Visifault the light emerges from at the south end (input side for 1064nm). This light is collimated with the fiber coupler at that end and serves as a reference for the optical axis along which the 1064 light must be directed. Once the two beams (red and 1064) are overlapped with the beam steering mirrors, the Visifault was disconnected from the fiber and the fibre output ( 1064 at the PSL table) is maximized by walking the beam at the input end and adjusting the collimation at the input.
The output of the fiber has been collimated with a fiber coupler.
7.5mW are incident on the input end and 1.3mW have been measured at the output. This output power is adequate for the observing the beats with PSL NPRO.
|
3866
|
Thu Nov 4 19:26:51 2010 |
Suresh | Update | Locking | Changes to the Video MUX reversed |
All the temporary changes to the video cables and the video MUX ( 3843 ) have been reversed and the system returned to its original state. |
4143
|
Wed Jan 12 17:22:47 2011 |
Suresh | Configuration | Locking | MC demod phase adjusted to minimise the I output |
[Koji, Suresh]
We wanted to check and make sure that the relative phase of the two inputs ( local oscillator and photodiode signal ) to the demod board is such that the Q output is maximised. We displayed the I and Q signals on the oscilloscope in XYmode with I along the X direction. If Q is maximised (and therefore I is minimised) the oscillocope trace would be perfectly vertical since all the signal would be in Q and none in I. Initially we noted that the trace was slightly rotated to the CCW of the vertical and that a short cable was present in the PD input line. Removing this rotated the trace CW and made it pretty much vertical. The screen shot of the oscilloscope is below.
. |
4155
|
Fri Jan 14 12:29:57 2011 |
Koji | Update | Locking | Next steps for the green |
These are the next steps for a better operation of the arm locking. They are suitable for the day time activities
Reconfiguration of the X-End table
- End transmission power monitor (CDS model exists, need to configure the PD)
- IR steering mirror for the transmon
- Restore/align end green beam
- Relocate the end trans CCD
- Connect the video output cable for the X-end CRT monitor
LSC Whitening
- LSC Whitening binary IO connection
They are not urgent but also good things to do
MC servo characterization
- Error signal: frequency noise
- Loop characterization
Arm cavity characterization with cavity sweep
- Arm finesse for 1064nm and 532nm
- Arm FSR measurement with 1064 (and optionally with 532nm simultaneously)
- Arm g-factor for 1064nm and 532nm |
4161
|
Sun Jan 16 02:20:59 2011 |
Suresh | Update | Locking | comparing the PSL with the X-end-NPRO through the green beat |
Objective:
We wish to study the coherence of the two NPROs i.e. PSL and the X-end-NPRO by locking both of them to the X-arm and then observing the green beat frequency fluctuations.
What we did:
a) locked the PSL to the X-arm as described in 4153
b) locked the x-end-NPRO to the X-arm with a PDH lock to the reflected green from the ETMX
c) Obtained the green beat signal with a spectrum analyser as described in 3771
Observations:
Please see the attached screen shots from the spectrum analyser. They are taken with different BW and sweep range settings. They give a estimate of the width of the green beat signal and the range of the frequency fluctuations of the beat-note.
  

Estimates:
a) width of the beat note is less than 6KHz if measured over time scales of a few milli seconds
b) the frequency fluctuations of the beat note are about 100KHz over time scales longer than 100ms
Next Step:
We wish to record the beat note frequency as a function of time in order to establish the stability over time scale of a day.
|
4166
|
Wed Jan 19 03:37:30 2011 |
Suresh | Update | Locking | comparing the PSL with the X-end-NPRO through the green beat |
[Kiwamu, Suresh]
Today we attempted to convert the beat-note frequency into an analog voltage using the SR620 frequency counter.
First an observation: the stability of the green beat was seen to be much better than the 100kHz fluctuation seen yesterday. Probably because Kiwamu noticed that one of the MC mirrors had a large variance in its motion and changed the gain and filter parameters to decrease this. The PSL was therefore more stable and the green peak fluctuation was less than 10kHz over time scales of a few seconds.
SR620 D/A output resolution given by the manufacturer is 5mV over the -10 to +10V range and this range corresponding to 300MHz. We, however saw fluctuations of 100mV on the screen which looked as if they corresponded to the least significant bit. This would imply a resolution of 1.5MHz at this range. Even if the manufacturer's claim was true it would lead to a resolution of 75kHz, far in excess of the required resolution a few hundred Hz.
We therefore require to set up the VCO-PLL to obtain a finer frequency resolution.
In the mean time the green beat drifted beyond the 100MHz detection band of the green-PD. So we changed the x-end-NPRO temperature by -0.05 to bring it back into the detection band.
We are also considering, Rana and Koji's suggestion of using a set of 14 flip-flops to divide the ~80MHz beat frequency so that it comes down to about 4kHz. This could then be sampled by the usual 16-bit, 64kSa/s ADC cards and brought into the digital domain where further digital processing would be needed to extract the the required frequency variations in the 0 to 10kHz band. Found a nice paper on this object |
4177
|
Thu Jan 20 15:39:59 2011 |
Aidan | Update | Locking | Upper limit on frequency noise of ADC |
[Aidan, Kiwamu]
Kiwamu and I plugged the output from a DS3456 function generator into the ADC and started recording the data. The func. generator output a 237.8Hz, 1Vpp sine wave. We chose this value because it corresponds to the FSR of a 38.5m cavity (=3.896MHz) divided by 2^14, the frequency divider amount we intend to use.
Since 1 FSR divided down is 237.8Hz and corresponds to a length change of the cavity of 532nm/2 = 266nm, then we can, roughly, say that a frequency change of 1Hz corresponds to a length change in the cavity of approximately 1nm. The width of the 237.8Hz peak in the spectra corresponds to an upper limit on the noise floor due to digitizing the signal (this could be limited by the ADC, or the function generator, or the windowing on the FFT).
The FWHM of the peak in the spectrum was approximately 5mHz, corresponding to an uncertainty in the length of the cavity of about 6pm (we used a Hanning Window, 50% overlap and a BW of 2.92mHz, 7 averages). Regardless of what is the dominant contribution to the width of the peak, this implies that the frequency noise associated with digitizing a signal in the ADC is much smaller than we require and will not limit our performance if we choose to use a frequency divider and digital PLL with the Green Locking.
RA: Here's the previous measurement |
4178
|
Thu Jan 20 17:00:39 2011 |
Aidan | Configuration | Locking | Ballpark figures for Green Locking PLLs (Digital vs Analogue) |
If we use a digital PLL for locking the frequency of the PSL and END green lasers then we can expect a UGF of around 1kHz (assuming a sampling rate of 16kHz). Let's assume a simple 1/f loop giving a loop gain of ~1000x at 1Hz. If the free-swinging ETM pendulum motion at 1Hz is of the order of 1 micron, then the residual motion at 1Hz, once we lock the digital PLL by actuating on the ETM position, will be of the order of 1nm. This is bordering on too high.
Alternatively, is we use an analogue PLL then we can expect a much higher UGF and many orders of magnitude more gain at 1Hz (see here). So we would expect the residual motion of the pendulum to be much smaller - probably limited by some other noise source somewhere in the system (I doubt it's going to be reduced by 12 orders of magnitude).
RA: I think ballpark's not good enough for this. To see what's good enough, we need to to an analysis similar to what Bram has for the ALS. Get the 40m seismic spectrum from the arm locking spectrum or the green laser feedback signal and then correct it for a realistic loop shape.
KA: For this purpose I have made the simulink model for the green locking more than a year ago, but the entire green team has consistently neglected its presence...
https://nodus.ligo.caltech.edu:30889/svn/trunk/docs/upgrade08/Green_Locking/Servo_modeling/091121/ |
4182
|
Fri Jan 21 11:45:01 2011 |
Aidan | Configuration | Locking | Ballpark figures for Green Locking PLLs (Digital vs Analogue) |
Quote: |
If we use a digital PLL for locking the frequency of the PSL and END green lasers then we can expect a UGF of around 1kHz (assuming a sampling rate of 16kHz). Let's assume a simple 1/f loop giving a loop gain of ~1000x at 1Hz. If the free-swinging ETM pendulum motion at 1Hz is of the order of 1 micron, then the residual motion at 1Hz, once we lock the digital PLL by actuating on the ETM position, will be of the order of 1nm. This is bordering on too high.
Alternatively, is we use an analogue PLL then we can expect a much higher UGF and many orders of magnitude more gain at 1Hz (see here). So we would expect the residual motion of the pendulum to be much smaller - probably limited by some other noise source somewhere in the system (I doubt it's going to be reduced by 12 orders of magnitude).
RA: I think ballpark's not good enough for this. To see what's good enough, we need to to an analysis similar to what Bram has for the ALS. Get the 40m seismic spectrum from the arm locking spectrum or the green laser feedback signal and then correct it for a realistic loop shape.
KA: For this purpose I have made the simulink model for the green locking more than a year ago, but the entire green team has consistently neglected its presence...
https://nodus.ligo.caltech.edu:30889/svn/trunk/docs/upgrade08/Green_Locking/Servo_modeling/091121/
|
Agreed. It doesn't completely rule out the digital PLL. I'll check out Kiwamu's model. |
4822
|
Wed Jun 15 02:20:00 2011 |
Jenne | Update | Locking | MICH noise budget? |
I would like to announce my confusion with regard to the MICH noise budget, in hopes that someone else has some inspiration.
If you tilt your head sideways, you will notice that in this plot (totally uncalibrated, as yet), the BLACK trace, which is my white-light measurement of the AS55 shot noise is above the AS55Q noise when the Michelson is locked (true only at low frequency). You will also notice that the same appears to be true for the Whitening Filter + Antialiasing Filter + ADC noise (GRAY trace). Since Black, Gray, Pink and Green should all have the same calibration factor (a constant), calibrating the plot will not change this. Brown and Blue are the MICH_OUT (aka MICH_CTRL) for dark and bright fringes, respectively.
I measure 58mV at the DC out of the AS55 PD when the Michelson is locked on the bright fringe. This (assuming DC transimpedance of 50ohms) gives 1.16mA of DC photo current.
So. What is going on here? Am I totally confused??
In other news, assuming (which I'm not 100% confident about right now) that these traces are vaguely correct, the Michelson is limited by shot noise above ~20Hz. This is...good? We want to be shot noise limited. Do we want to be limited at such a low frequency?
(Also, yes I can calibrate the plot to m/rtHz, but no, I won't tonight because something is funny with my calibration for the free running noise and I'll fix it tomorrow.)

|
4823
|
Wed Jun 15 12:16:37 2011 |
Jamie | Update | Locking | MICH noise budget? |
Quote |
If you tilt your head sideways, you will notice that in this plot (totally uncalibrated, as yet), the BLACK trace, which is my white-light measurement of the AS55 shot noise is above the AS55Q noise when the Michelson is locked (true only at low frequency). You will also notice that the same appears to be true for the Whitening Filter + Antialiasing Filter + ADC noise (GRAY trace). Since Black, Gray, Pink and Green should all have the same calibration factor (a constant), calibrating the plot will not change this. Brown and Blue are the MICH_OUT (aka MICH_CTRL) for dark and bright fringes, respectively. |
Hey, Jenne. I think there are a couple of things. First, you're missing a PD dark noise measurement, which would be useful to see.
But I think the main issue is that it sounds like all of your closed loop measurements are done with the in-loop PD. This means that everything will be suppressed by the loop gain, which will make things look like they have a noise lower than the actual noise floor. |
4893
|
Tue Jun 28 02:11:47 2011 |
Jenne | Update | Locking | Latest MICH noise budget |
I have measured / calculated the latest MICH noise budget. It doesn't really look all that stellar.

As you can see, we are nowhere near being shot noise limited, since there's a huge discrepancy between all of the measured spectra and the teal Shot Noise line.
One possible suspect is that the analog whitening filters weren't on when I took my measurements. I didn't actually check to ensure that they were on, so they might not have been. Right now we're limited by electronics and other boring noises, so I need to make sure we're limited by the noise of the diode itself (we don't have enough light in the IFO to actually be shot noise limited since that takes 2.5mA for AS55 and I only have 1.1mA, but we should be ~within a factor of 2ish). |
5035
|
Tue Jul 26 03:15:52 2011 |
Jenne | Update | Locking | Latest MICH noise budget |
[Jenne, Rana]
We had another look at the MICH noise budget tonight. Rana has verified that my techniques / math aren't too ridiculous.
In the first attachment, you'll notice that the MICH noise is waay above the shot noise of 1mW on the beam splitter. We don't know why. One problem is that the modulation depth of the 55MHz is too low by ~a factor of 10. Kiwamu and his magical resonant circuit are working on fixing this. This will not, however, fix the huge discrepancy here. More investigation and meditation is required! For this measurement, the whitening gain of AS55 was set to 42dB for both I and Q.
In the 2nd attachment, the PSL shutter is closed, so all of these are dark measurements of AS55. (The input matrix on the LSC screen is AS55Q * 1 -> MICH_IN1, so they're the same). All we've done is change the whitening gain before the ADC. For 0dB and 9dB, you can see that the low freq noise didn't change - here we're still limited by the ADC noise. With 21dB and 42dB we're clear of the ADC, so either is fine. Unfortunately, the high freq stuff when the loop is on matches up with the high freq part of the dark noise, so that's part of the problem.... |
5051
|
Thu Jul 28 02:33:04 2011 |
Jenne | Update | Locking | Yarm flashing, but not yet locked |
Because I'm too lazy to write a cohenrent elog right now, here's my notes that I wrote while working tonight:
Elog notes, 27July2011
Aligned Xarm, just to check on it. Had to flip sign of TRX in DCPD filter bank (to gain of -1) to make the signal positive.
Restored Yarm, see some slight flashing, but no lock yet.
Adjusted phase rotation of AS55 from 56.5deg to 60deg, just by-eye trying to maximize AS55I, my arm error signal. AS55I goes from ~ -40 to +60 counts
Tried fitzing with Yarm gain, flipping sign, incr gain. No real change in signals, or flashing.
Incr. ETMY oplev gains to -0.4 from -0.2
Engaged ELP35's on Pit and Yaw, to be more similar to other optics. However, right now all of the optics have different things in their filter banks. Why??
Arm is flashing pretty reliably now, but still not locking. The trigger threshold is always satisfied, so that's not it. |
5233
|
Sun Aug 14 20:04:40 2011 |
Keiko, Anamaria, Jenne, and Kiwamu | Summary | Locking | central part ifo locking plan |
GOAL : To lock the central part of ifo
Here is the plan:
Mon - assemble all the cables from PDs and mixers, and check the CDS channels. Prepare the beamsplitters.
Tue - The current paths to REFL11 and REFL55 will be modified to the four paths to REFL11, 33, 55, 165. And the PDs will be placed.
Wed, Thu - during waiting for the ifo available with vacuum, help aligning the POP, POX, POY. In parallel, a simulation to find the PRC length SRC
length tolerance will be proceeded.
Fri - When the ifo becomes available with vacuum, the sensing signals by 3-f scheme will be obtained with proper demodulation phases.
Sat - Try to lock the central part of the ifo with the new 3-f signals. |
5243
|
Mon Aug 15 21:43:29 2011 |
Anamaria and Keiko | Summary | Locking | central part ifo locking project |
REFL33 and REFL165 cables were connected from the AP table to the rack. Cables on the rack for REFL33I, 33Q, 165I, 165Q ports were connected, too. Connections were confirmed by the data viewer. Two SMA cables which will be used for the two PDs on the AP tabl were built. We will be able to place the two PDs tomorrow. The beamsplitters to split the laser to REFL33 and REFL165 ports were mounted and ready to be placed. |
6421
|
Thu Mar 15 04:04:23 2012 |
Koji | Configuration | Locking | PRC Matching issues |
Kiwamu and Koji
We found that the intra-cavity mode of the PRC is not round although it was obvious even with the DARK and REFL port images.
We need to review the mode matching situation.
In order to look at the PRC intra-cavity mode, we reconfigured the POP CCD.
If we look at the beam reflected from the Michelson, the beam is round. However, the PRC intra-cavity mode can never be round
in any resonant conditions. (Pict 1, 2, and 3, for the sideband resonant, carrier resonant conditions and another carrier resonant
one, respactively). Particularly the mode of the carrier resonant case is very unstable and always changing.

 
By misaligning the PRM, we can compare between the spot directly reflected from the Michelson and the one after additional round trip in the PRC (Pic 4).
They looks round, but it was obvious the secondary reflection is dimmer and larger (Pic 5). The intensity difference corresponds to the factor RPRM RMI
(i.e. product of the reflectivities for the PRM and MI). It can be understand if the dimmer spot looks smaller due to the artifact of the CCD. But it is opposite.
This may mean the mode matching is not correct. We are not sure what is not right. This could be just an incorrect incident beam, the curvature error of the PRM,
beam is distortec by the TT mirrors, or some other unknown reasons.
More precise analysis can be done with quantitative analysis of those two spots with Beamscan. This could happen tomorrow.
 
|
6437
|
Thu Mar 22 17:35:59 2012 |
kiwamu | Update | Locking | mode profiles of the POP and POX beams : not bright enough |
I tried to measure the beam profiles at the POP and POX ports as Koji mentioned in his entry (#6421).
However it turned out that the beam powers were too small to be measured with our beam scan at those ports.
So I will move on to measurements at the REFL port as Rana suggested because the laser power is much larger than that of POP and POX.
(If the data of the POP and POX beam profiles turn out to be very necessary, we will do the razor blade technique with a more sensitive photo diode)
Quote from #6421 |
More precise analysis can be done with quantitative analysis of those two spots with Beamscan. This could happen tomorrow.
|
|
6532
|
Thu Apr 12 23:52:49 2012 |
Jenne | Update | Locking | PRMI locked - 'bouncy' |
I am locking some things, and have the PRM aligned, and it will stay locked for short periods of time, but as Kiwamu warned me, when the PRM alignment is better, the lock is more "crazy" and unstable. This should go on our list of mysteries.
|
6596
|
Thu May 3 13:19:17 2012 |
Jenne | Update | Locking | More success last night |
I locked each arm, and the Michelson last night, no problems after I increased the Yarm gain from 0.1 to 0.2 . I checked the green beam alignment just before going home, and both of the green beams are locking on ~03 or 04 modes, so aligning them is on the list for today. |
6629
|
Wed May 9 04:47:20 2012 |
Jenne | Update | Locking | PRM is really moving when PRMI locked |
A few things tonight. Locked both arms simultaneously (IR only). Locked MICH, Locked PRMI, although it doesn't like staying locked for more than a minute or so, and not always that long.
Locking PRCL was possible by getting rid of the power normalization. We need to get some triggering going on for the power norm. I think it's a good idea for after the cavity is locked, but when PRCL is not locked, POP22 is ~0, so Refl33/Pop22 is ~inf. The PRCL loop kept railing at the Limit that was set. Getting rid of the power normalization fixed this railing.
I took some spectra of PRM's oplev, while PRMI was locked, and unlocked. The PRM is definitely moving more when the cavity is locked. I'm not sure yet what to do about this, but the result was repeatable many times (~6 or 7 over an hour or so). The OpLev spectra when PRMI was locked didn't depend too strongly on the PRM's alignment, although I think that's partly because I wasn't able to really get the PRM to optimal alignment. I think POP22I is supposed to get to 7 or so...last week with Koji it was at least flashing that high. But tonight I couldn't get POP22I above 4, and most of the time it wouldn't go above 3. As I was aligning PRM and the circulating SB power increased, POP22I fluctuations increased significantly, then the cavity unlocked. So maybe this is because as I get closer, PRM gets more wiggly. I tried playing 'chicken' with it, and took spectra as I was aligning PRM (align, get some improvement, stop to take spectra, then align more, stop to take spectra....) but usually it would fall out of lock after 1-2 iterations of this incremental alignment and I'd have to start over. When it relocked, it usually wouldn't come back to the same level of POP22I, which was kind of disappointing.
In the PDF attached, pink and light blue are when the PRMI is locked, and red and dark blue are no PRCL feedback. The effect is more pronounced with Pitch, but it's there for both Pitch and Yaw.
Also, I need to relook at my new restore/misalign scripts. They were acting funny tonight, so I'm taking back my "they're awesome, use them without thinking about it" certification. |