40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 228 of 341  Not logged in ELOG logo
ID Date Author Typeup Category Subject Text Attachments
  10241   Sat Jul 19 17:36:44 2014 JenneUpdateLSCRIN in arm transmissionI looked at what the RIN contribution of
the sqrtInv sensor is by locking the arms
individually on IR using POX and POY. 
 TransSqrtInvRIN_vs_ALSsensing_18July2014.pngThorlabsRIN_16July2014.png 
  10242   Sat Jul 19 20:51:51 2014 KojiUpdateLSCRIN in arm transmissionYour
calibration of the ALS signal should be revised.
The phase for the ALS is not an optical
  
  10243   Sun Jul 20 09:26:27 2014 EvanUpdateElectronicsMC servo card modifications in DCC

    

       
            
  
  10244   Mon Jul 21 10:30:38 2014 HarryUpdateGeneralFiber Mode Measurement Purpose
The idea was to measure the profile
of the light coming out of the fiber, so
 fiberModeMeasurement.pngfiberModeFit2.pngfiberModeMeasurement2.zip 
  10245   Mon Jul 21 10:51:06 2014 SteveUpdateVACN2 supply run outInterlock closed valve V1, V4, V5 and VM1
when the nitrogen supply run out. The IFO
pressure rose to P1 1 mTorr
 outofN2.png 
  10247   Mon Jul 21 13:58:33 2014 ericqUpdateIOOMC autolocker acting upThe autolocker claimed it was running and
blinking, but not doing anything (i.e. lock
bit was not updating and no switches or sliders
  
  10249   Mon Jul 21 18:08:19 2014 HarryUpdateGeneralFiber Mode Measurement

    

       
            
 fiberModeMeasurement3.png 
  10250   Tue Jul 22 08:24:42 2014 EvanUpdateElectronicsMC servo card: modified schematic

    

       
            
 D1400242.zip 
  10251   Tue Jul 22 08:36:08 2014 EvanUpdateIOOMC servo TFs

    

       
            
 MCtfExpectations.pdf 
  10253   Tue Jul 22 15:54:19 2014 ericqUpdateSUSITMY Oplev Recentered ITMY oplev was nearly clipping in
yaw, causing wonky behavior (POY lock popping
in and out frequently). I recentered it and
  
  10255   Tue Jul 22 16:26:04 2014 HarryUpdateGeneralFiber Mode MeasurementI repeated this process once more, this
time using the computer controlled stage
that the beam profiler is designed to be
 fiberModeProfile3.pngfiberModeMeasurement4.zip 
  10256   Tue Jul 22 17:45:11 2014 HarryUpdateGeneralWeekly Update The Past Week
 
I spent the past week coupling NPRO
  
  10257   Tue Jul 22 23:10:12 2014 AkhilUpdateGeneralWeekly Update Work
Done
  
  10258   Wed Jul 23 02:01:15 2014 JenneUpdateLSCRIN in arm transmission - revised calibration 
As Koji pointed out, I messed up
the calibration.  However, fixing it
 TransSqrtInvRIN_vs_ALSsensing_18July2014.png 
  10259   Wed Jul 23 10:39:18 2014 SteveUpdateCamerasvideo quad processors replacedQuad
processor 2 & 3 were replaced.
  
  10260   Wed Jul 23 10:40:23 2014 NichinUpdateGeneralWeekly UpdateTo do:


   Measure and calibrate out  attenuation
and phase changes due to RF cables in the
  
  10261   Wed Jul 23 11:15:54 2014 AkhilUpdateElectronicsInstallation of FCs in the 40m As a part of installation of two(X-ARM
and Y-ARM) frequency counters in the 40m,
I have tested their performance when using
 Timingwith2FCs.png 
  10262   Wed Jul 23 11:32:04 2014 KojiUpdateLSCIFO warming upAlone with the IFO. Started from some conversation
with it.
Some ALS trials: Found the Y-end
 140722_ALS.pdf 
  10263   Wed Jul 23 11:54:27 2014 NichinUpdateElectronicsCharacterization of demodulator boards.

    

       
            
 1.pdf2.pdf 
  10264   Wed Jul 23 17:54:51 2014 HarryUpdateGeneralCoupling Improvements plus PER Measurement Setup Purpose
We wanted to improve the coupling
into the fibers, because it's very rarely
 PERSetup.png 
  10265   Wed Jul 23 18:53:11 2014 NichinUpdateElectronicsTime delay in RG405 coaxial cables A time delay can be modeled
as the exponential transfer function :  e(-sTd)
 RFcable1.pdfRFcable2.pdf 
  10266   Wed Jul 23 19:30:34 2014 NichinUpdateElectronicsTime delay in the RF multiplexer (Rack 1Y1)A time
delay can be modeled as the exponential
transfer function :  
 RFmux1.pdfRFmux2.pdf 
  10267   Wed Jul 23 23:43:28 2014 ericqUpdateLSCLocking efforts; Wrath of the Mode Cleaner [Koji, ericq]
We were working on getting back into
the locking groove tonight.
  
  10268   Thu Jul 24 09:18:15 2014 SteveUpdateGeneralfour days   4days.png 
  10269   Thu Jul 24 13:01:39 2014 ericqUpdateSUSPRM OPLEV! Here's a fun fact: since
the great computer failure of June2014, the
PRM Oplev gains have been ZERO.
 oops.pngPRMOLPIT.pdfPRMOLYAW.pdf 
  10270   Thu Jul 24 14:20:30 2014 SteveUpdateSUSPRM & other oplev gain settings checked The PRM sus gains checked OK
All other suspension oplev gains
setting were checked out OK
 PRMgainsSensors.png 
  10271   Thu Jul 24 17:37:19 2014 HarryUpdateGeneralCoupling Improvements plus PER Measurement Setup

    

       
            
  
  10272   Thu Jul 24 19:28:43 2014 AkhilUpdateGeneralThermal Actuator Transfer Functions As a part of temperature actuator
characterization, today Eric Q and I made
some measurements for the open loop TF of
 TF-X-ARM.pdfTF-Y-ARM.pdf 
  10273   Fri Jul 25 17:28:31 2014 HarryUpdateGeneralFOL Box and PER Update Purpose
We're putting together a box to go
into the 1X2 rack, to facilitate the frequency
 FOLBox.png 
  10274   Sat Jul 26 10:12:19 2014 AkhilUpdateGeneralData Acquisition from FC into EPICS Channels I succeeded in creating a new channel
access server hosted on domenica ( R Pi)
for continuous data acquisition from the
  
  10275   Sat Jul 26 13:10:14 2014 AkhilUpdateGeneralThermal Actuator Transfer FunctionsKoji said that the method we used for X-arm
thermal actuator TF measurement was not correct
and suggested us to make measurements separately
 TFX_new.pdf 
  10276   Sat Jul 26 13:38:34 2014 JamieUpdateGeneralData Acquisition from FC into EPICS Channels

    

       
            
  
  10277   Sat Jul 26 14:35:28 2014 AkhilUpdateGeneralData Acquisition from FC into EPICS Channels

    

       
            
  
  10279   Sat Jul 26 15:30:15 2014 Joseph AreedaUpdateComputer Scripts / ProgramsNDS2 server propem on megatronThe NDS2 server on megatron was unresponsive
for what i think was the last couple of days.
The NDS the log file (~nds2mgr/logs/nds2-201407151045.log)
  
  10280   Mon Jul 28 10:42:43 2014 NichinUpdateElectronicsDemodulator board's characterization I used vector fitting to fit the
transfer functions between RF input and PD
RF MON of demodulator boards. These fittings
 Demod_Fit.pdf 
  10281   Mon Jul 28 16:34:02 2014 AkhilUpdateGeneralCalibration of measured Thermal Actuator TFs To calibrate the measured TFs and
characterize the thermal actuator for the
FOL loop, we [ Me, Eric Q, Koji ] made the
 mirrorTF2.pdf 
  10282   Mon Jul 28 17:25:32 2014 HarryUpdateGeneralFiber Mode With Collimators Purpose
We want a measurement of the fiber
modes at either end, with the collimators,
 end1Profiles.pngend2Profiles.pngFiberModeWCollimators.zip 
  10283   Mon Jul 28 17:53:00 2014 AkhilUpdateGeneralWork plan for the Upcoming weeks- FOL Project [Akhil, Harry]
Work
Completed
  
  10284   Tue Jul 29 07:54:34 2014 SteveUpdateSUSETMX damping restoredETMX sus damping restored   
  10285   Tue Jul 29 16:41:54 2014 KojiUpdateLSCMC servoThe MC openloop gains were measured
with several conditions
- MC fast/PC crossover was measured
 MCservo.pdf 
  10286   Tue Jul 29 18:00:20 2014 AkhilUpdateLSCCalibration of ETMX and ETMY actuatorsThe ultimate goal of characterizing the
temperature actuator turned to be fruitful
in obtaining the calibration values for ETMX
 PZT_ETMX_TF.pngPZT_ETMY_TF.pngPZT_ITMX_TF.pngPZT_ITMY_TF.png 
  10287   Tue Jul 29 18:52:42 2014 HarryUpdateGeneralPSL and AUX Coupling Waist Measurement//edit Manasa//  Harry will update
this elog with before/after pictures of the
table and power of the 1064nm rejected beam
 9x 
  10288   Tue Jul 29 18:58:57 2014 NichinUpdateComputer Scripts / ProgramsPDFR update and Test runThe PDFR system's interface and scripts
have been updated to include quite a few
more features.
 16.pngPDFR_testRun_29-07-2014.pdf 
  10289   Tue Jul 29 19:00:40 2014 HarryUpdateGeneralWeekly Plan (7.29.14) The Past Week
In the past week, I have improved
the coupling in the fiber testing setup on
  
  10290   Tue Jul 29 20:14:08 2014 AndresUpdate40m Xend Table upgradeXarm Green steering mirror upgrade Xarm Green Steering Mirror Upgrade
Nick
and I did the upgrade for the green steering
mirror today. 
  
  10291   Tue Jul 29 20:14:10 2014 KojiUpdate40m Xend Table upgradeXarm Green steering mirror upgradeThat
was super fast! Great job, Andres and Nic!
  
  10292   Tue Jul 29 21:34:41 2014 ericqUpdateComputer Scripts / ProgramsSVN bulletinA heads
up to anyone using SVN with computers on
the Martian network:
  
  10293   Wed Jul 30 00:42:27 2014 KojiUpdateLSCMC servoI used an oscillator and an oscilloscope
to measure the open loop transfer function
at higher frequency than 100kHz.
 MCservo.pdf 
  10294   Wed Jul 30 09:33:33 2014 SteveUpdateSUSRIN of HeNe lasersFrom old 40m elog 5-29-2007  RINHeNe.pdfRINHeNe2.pdfRINHeNe2.pdfRINHeNe3.pdf 
  10295   Wed Jul 30 09:51:18 2014 SteveUpdatePSLPSL Innolight controller fan is noisy

    

       
            
  
ELOG V3.1.3-