40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 228 of 341  Not logged in ELOG logo
IDup Date Author Type Category Subject Text Attachments
  11424   Fri Jul 17 04:56:37 2015 IgnacioUpdateGeneralMCL Wiener filtering + FIR to IIR conversion using vectfit 

We took data for the mode cleaner
a while ago, June 30th I believe. This data
 9x 
  11425   Sat Jul 18 06:12:07 2015 IgnacioUpdateGeneralMCL Wiener filtering + FIR to IIR conversion using vectfit (Update)(updateAfter Eric gave me feedback on my
previous elog post, I went back and fixed
some of the silly stuff I stated.
 15x 
  11426   Sat Jul 18 14:55:33 2015 jamieUpdateGeneralall front ends back up and runningAfter some surgery yesterday the front
ends are all back up and running:


Eric found that one of
 cds-good.png 
  11427   Sat Jul 18 15:37:19 2015 JamieSummaryCDSCDS upgrade: current statusSo it appears we have found a semi-stable
configuration for the DAQ system post upgrade:

 cds-good.pngsus-damped.png 
  11428   Sat Jul 18 16:03:00 2015 jamieUpdateCDSEPICS freezes persistI notice that the periodic EPICS freezes
persist.  They last for 5-10 seconds. 
MEDM completely freezes up, but then it comes
  
  11429   Sat Jul 18 16:59:01 2015 jamieUpdateCDSunloaded, turned off loading of, symmetricom kernel module on fbfb has been loading a 'symmetricom'
kernel module, presumably because it was
once being used to help with timing. 
  
  11430   Mon Jul 20 11:57:17 2015 ericqUpdateGeneralArm Locking recoveredThe interferometer is warming up!

I had some issues locking the IMC
at first. It turned out that the MC3 side
  
  11431   Mon Jul 20 16:45:15 2015 Max IsiConfigurationGeneralSummary page c1sus.ini error correctedBad syntax errors in the c1sus.ini config
file were causing the summary pages to crash:
a plot type had not been indicated for plots
  
  11432   Tue Jul 21 05:17:09 2015 IgnacioUpdateGeneralMore clear accelerometer huddle tests resultsI generated the following plots from the
two sets of huddle test data we have for
the accelerometers. 
 new_data.pngnew_data.pngold_data_1.pngold_data_1.pngold_data_2.png 
  11433   Tue Jul 21 21:25:18 2015 Max IsiUpdateGeneral40m LDAS accountA shared LIGO Data Grid (LDG) account was
created for use by the 40m lab. The purpose
of this account is to provide access to the
  
  11434   Tue Jul 21 21:33:22 2015 Max IsiUpdateGeneralSummary pages moved to 40m LDAS accountThe summary pages are now generated from
the new 40m
LDAS account. The nodus URL (https://nodus.ligo.caltech.edu:30889/detcharsummary/)
  
  11435   Wed Jul 22 14:10:04 2015 ericqUpdateCDSRCG DiagnosticsNow that we've seemed to landed on
a working configuration, I've re-ran
the tests first described in ELOG
 filterShapes.pngCDS_diag_codes.zip 
  11436   Wed Jul 22 15:09:40 2015 ericqUpdateGeneralIMC workThe other night, I spent some time with
the mode cleaner. 

First, I made some model changes
  
  11437   Wed Jul 22 22:06:42 2015 EveSummarySummary PagesFuture summary pages improvements- CDS Tab

We want to monitor the status of the
  
  11438   Thu Jul 23 03:09:05 2015 ericqUpdateLSCaLIGO demod board lives!I'm a little mystified. Peeking inside
the aLIGO demod board, I saw that the reason
that two of the channels weren't working
 beatbox_vs_aLIGO.png 
  11439   Thu Jul 23 15:41:41 2015 SteveUpdatePEMfitting ants with TERROPasadena got 0.2" of  rain on
Saturday. Temperatures were high with high
humidity since than.The ants were back in
  
  11440   Thu Jul 23 20:54:42 2015 JessicaUpdateGeneralALS Delay Line BoxThe front panels for the ALS delay   
  11441   Thu Jul 23 20:57:15 2015 JessicaSummaryGeneralApplying Pre-filter to data before IIR Wiener FilteringI updated my bandpass filter and have  BodePlot.pngacc_bandpass.pngmcl_seis.png 
  11442   Thu Jul 23 21:12:14 2015 IgnacioUpdateGeneralNewer accelerometer huddle test data + detrendingIn the last post concerning the self noise
of the accelerometers, I mentioned the differences
between the two data sets I was playing with.
 old_data_1.pngold_data_2.pngnew_data.pngsix_old_data.png 
  11443   Fri Jul 24 13:49:09 2015 SteveUpdatesafetyLock doors please !Thursday morning I found the control room
emergency exit not locked.

Please check the doors when leaving
  
  11444   Fri Jul 24 18:12:52 2015 Max IsiUpdateGeneralData missingFor the past couple of days, the summary
pages have shown minute trend data disappear
at 12:00 UTC (05:00 AM local time). This
 C1-ALL_FBDB3F_TIMESERIES-1121731217-86400.png 
  11445   Fri Jul 24 20:32:15 2015 ericqUpdateElectronicsLSC LO distribution box power button replaced As happened with the RF distribution box
in the IOO rack a while back, the shiny blue
power button in the LSC LO distribution box
 2015-07-24_15.43.56.jpg2015-07-24_16.57.19.jpg 
  11446   Fri Jul 24 23:08:53 2015 IgnacioUpdatePEMMC1 accelerators moved for future huddle testI have moved the MC1 accelerators and cable
to the huddle test set up, in order to see
how a six witness huddle test with the improved
 image1.JPG 
  11447   Mon Jul 27 16:47:53 2015 ericqUpdateIOOMC2 -> MCL Actuator TFOur noise cancellation SURFS will be doing
online subtraction on the mode cleaner length,
among other things. 
 mc2_2_mcl.pngMC2_2_MCL_TF.txt.zip 
  11448   Mon Jul 27 17:51:06 2015 EveUpdateSummary PagesNew summary page tabs and other improvementsThe summary pages can still be found at https://nodus.ligo.caltech.edu:30889/detcharsummary/ (EDIT:
in an older version of this post I listed
  
  11449   Tue Jul 28 05:00:03 2015 IgnacioUpdateGeneralSeismometer cansI've have been talking a little   
  11450   Tue Jul 28 09:31:35 2015 IgnacioUpdateGeneralNewest accelerometer huddle testI downloaded new accelerometer huddle test
data from last night and analyzed it. This
new data set is ~55 mins and uses the same
 selfnoise_allsix_miso_newest.png 
  11451   Tue Jul 28 14:58:59 2015 SteveUpdateGeneraldo not place anything on optical table topsSpecially heavy
items: old analoge scope or hardware loaded
 tabletops!.jpgtabletops!!.jpg 
  11452   Tue Jul 28 15:05:09 2015 SteveUpdatesafetyfire alarm test ? noWe just had fire alarm trigged avacuation
of the 40m lab.

It turned out that the CES building
 6minGaps.png 
  11453   Tue Jul 28 15:06:27 2015 SteveUpdateIOOPSL HEPA turned on   noHepa.jpg 
  11454   Tue Jul 28 16:42:25 2015 SteveUpdateGeneralJamies entry was deletedSorry Jamie, I accidentally deleted your
elog entry #11453
  
  11455   Tue Jul 28 17:07:45 2015 JamieUpdateGeneralData missing


  
  11456   Tue Jul 28 20:42:50 2015 JessicaSummaryGeneralNew Seismometer Data CoherenceI was looking at the new seismometer data
and plotted the coherence between the different
arms of 
 Coherence1.pngCoherence2.png 
  11457   Wed Jul 29 10:34:42 2015 IgnacioSummaryLSCCoherence of arms and seismometersJessica and I took 45 mins  (  8x 
  11458   Wed Jul 29 11:15:21 2015 JessicaSummaryLSCPSDs of Arms with seismometer subtractionIgnacio and I downloaded data from the
STS, GUR1, and GUR2 seismometers and from
the mode cleaner and the x and y arms. The
 Arms_PSD.pngXArm_PSD.pngYArm_PSD.png 
  11459   Wed Jul 29 14:32:01 2015 SteveUpdateGeneralHow not to solder 




 coldSoldering.jpg 
  11460   Wed Jul 29 17:51:56 2015 IgnacioUpdatePEMAccelerators moved back to MC1 and MC2We are done taking accelerator huddle test
data. So I moved back all six accelerometers
and cables to MC1 and MC2. I also relabel
 FullSizeRender.jpgFullSizeRender_2.jpg 
  11461   Wed Jul 29 21:40:39 2015 KojiSummaryCDSStatus of the frame data syncingThe trend data hasn't been
synced with LDAS since Jul 27 5AM local.

40m:
  
  11462   Thu Jul 30 02:06:20 2015 IgnacioUpdateIOOMC2 <-> MCL Actuator TF fittedEric downloaded MC2 to MCL transfer function
data (H) as well as its inverse, MCL to MC2
(Hinv). He also downloaded new MCL and MC2
 TF_BODE.pngMC2_2_MCL.pngTF_INV_BODE.pngMCL_2_MC2.png 
  11463   Thu Jul 30 03:19:24 2015 ericqUpdateLSCBack towards PRFPMI The refreshed ALS didn't look so bad
today (elog forthcoming), so I decided to
give PRFPMI locking a shot tonight. I was
  
  11464   Thu Jul 30 10:38:18 2015 SteveUpdatePEMY sesimostation is back onKoji soldered new 50" long cable for
the Y station.

 
 Guralps_are_back_on.pngYstation.jpg 
  11465   Thu Jul 30 11:47:54 2015 KojiSummaryCDSStatus of the frame data syncingToday it was synced at 5AM but
that was all.

40m:
  
  11466   Thu Jul 30 13:34:52 2015 KojiUpdatePEMY sesimostation is back onPlease check the spectra. If something
is wrong, please swap the cables between
X and Y in order to see if the cable is still
  
  11467   Thu Jul 30 14:27:18 2015 EveUpdateSummary PagesALS, ASC, LSC Summary PagesI've switches the ALS, ASC, and LSC
plots on the summary pages from plotting
raw frames, to plotting minute trends, instead.
  
  11468   Thu Jul 30 14:42:03 2015 ericqUpdateLSCaLIGO demod board lives!ALS is not currently
limited by the demod board or whitening electronics.
 partialALSbudget.pngdemodDriveLevels.pngALScoherences.pngpartialALSbudget.zip 
  11469   Thu Jul 30 15:24:54 2015 SteveUpdatePEMY sesimostation is back onAtm1,  New short-50" long cable
was installed at ETMY end ( Y-station ) between
Guralp-B ( MIT ) and granite base.
 NewShortCable-Y-B-Gur2.pnginterfaceInputSwapped.pngsameasAtm2.png 
  11470   Thu Jul 30 15:58:00 2015 ericqUpdateLSCBeat note Alignment fluctuation effects measured



 RF_RIN.pngRF_RINspec.pngRFampCoh.xml.zip 
  11471   Thu Jul 30 18:58:36 2015 JessicaUpdateGeneralALS Delay Line Box Front Panel TestingI tested both of the front panels (conductive
and isolated SMAs) with the ALS Delay Line
Box by driving extremely close frequencies
 Xarm_diff.pngYarm_diff.pngXarm_isolated.pngYarm_isolated.png 
  11472   Thu Jul 30 19:12:52 2015 IgnacioUpdateIOOYAW and PIT WFS Wiener filteringRana pointed out that another way to mitigate
seismic motion at in the mode cleaner would
be to look at the YAW and PITCH output  channels
 YAW.pngPIT.png 
  11473   Fri Jul 31 10:36:22 2015 SteveUpdatePEMX seismo station short cable removed 




 IMG_0009.JPG 
ELOG V3.1.3-