40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 226 of 344  Not logged in ELOG logo
ID Dateup Author Type Category Subject Text Attachments
  11323   Sun May 24 14:45:02 2015 KojiHowToGeneralHow to launch StripTools at specified locationsLLO Operator Tips:

koji.arai@cr9:/opt/rtcds/userapps/trunk/asc/l1/scripts/initial_alignment$
cat autostart_strips.sh 
  
  11324   Tue May 26 11:05:10 2015 SteveUpdatePEMworked around ETMY seism.The cable tray holder cross beam is removed
and cut short for good access to seismometer.
 ETMYseismic.pngcut.jpg 
  11325   Tue May 26 19:57:11 2015 ranaUpdateComputer Scripts / ProgramsifoCouplingLooks like a very handy
code, especially with the real statistical
  
  11326   Wed May 27 02:53:57 2015 ericqUpdateGeneralifo recovery logGiven my suspicion of fault with the X
Green BBPD, Koji generously provided me with
another one that he had confirmed to be working. 
  
  11327   Wed May 27 15:20:54 2015 ericqUpdateComputer Scripts / ProgramsChiara Backup HiccupThe local chiara backups are still failing
due to vanished source files. I've emailed
Max about the summary page jobs, since
  
  11328   Wed May 27 17:14:08 2015 ericqUpdateLSCX Aux Laser crystal temperature changedRana suspects that the lack of X beatnote
is related to the PSL laser temperature change
(ELOG
  
  11329   Thu May 28 10:42:19 2015 SteveUpdatePEMbad Guralp X-cable


 Gurs180dXbad.pngswappedGurs.png 
  11330   Thu May 28 15:10:44 2015 ranaUpdatePEMSeismic ConfusionYou are plotting the STS channels,
not Guralp. These are for the Trillium
240 seismometer.
  
  11331   Thu May 28 16:43:52 2015 SteveUpdatePEMGuralps swappedKoji and Steve,

The result: bad Guralp x-arm cable.

I will swap the short cables tomorrow
 GursSwapped.png 
  11332   Thu May 28 17:00:04 2015 KojiUpdateIOOFSS SLOW not engaged: is this intentional?I found that FSS SLOW servo is not engaged.
Is this intentional test to keep the NPRO
temp constant?
  
  11333   Thu May 28 17:12:32 2015 ericqUpdateIOOFSS SLOW not engaged: is this intentional?Yes, I had turned it off while looking
for the PSL/X AUX beat, and forgot to turn
it back on.
  
  11334   Thu May 28 21:10:46 2015 KojiUpdateGreen LockingALS-X noise huntingI have been looking at the X-end ALS setup.
I was playing with the control bandwidth
to see the effect to the phase tracker output
 150528_ALS.pdf 
  11335   Fri May 29 02:05:08 2015 ericqUpdateLSCEnd Laser temperatures setBoth
green beatnotes have been found with nominal
amplitudes. (X: -30dBm Y: -20dBm), at temperatures
  
  11336   Fri May 29 11:28:42 2015 ericqUpdateComputer Scripts / ProgramsChiara Backup HiccupI've changed the chiara local backup
script to read a folder exclusion file, and
excluded /users/public_html/detcharsummary,
  
  11337   Fri May 29 12:49:53 2015 KojiUpdateComputer Scripts / ProgramsChiara Backup HiccupIn fact, the file access is supposed to
be WAY faster now than in the RAID case.

As
  
  11338   Fri May 29 15:12:39 2015 KojiUpdateComputer Scripts / ProgramsChiara Backup HiccupActual data  backup_hours.pdf 
  11339   Mon Jun 1 08:32:14 2015 SteveUpdateSUSPRM damping restoredLocal earthquake 3.8 Mag tripped only PRM

Vac monitor is not communicating.

PSL HEPA turned on
 indio3.8Meq.png 
  11340   Mon Jun 1 10:26:53 2015 ericqUpdateCDSRCG Upgrade ImminentWe
are planning on upgrading the 40 CDS system
to the latest version of the LIGO RCG software,
  
  11341   Mon Jun 1 15:22:19 2015 SteveUpdatePEMGuralps X- short cable is bad 




 seismGur1-2.png 
  11342   Mon Jun 1 20:05:36 2015 ranaUpdateCDSRCG Upgrade Imminent

  
  11343   Tue Jun 2 21:22:07 2015 rana, kojiConfigurationIOOAOM inserted in beam and alignedWe
spent an hour today to put the AOM back in
  
  11344   Wed Jun 3 11:55:52 2015 SteveUpdateOptical LeversPRM-BS oplev I'm getting ready change the Newport
Ultima U100-AC to SS-Polaris-K1 
LOW DRIFT MIRROR MOUNTS
 PRM-BS_oplEr_noLenses.pngPRM-BSopl_3jun2015.jpgopServos.png10d_trend_opl.pngopl_trend_40d.png 
  11345   Wed Jun 3 17:04:08 2015 ericqUpdatePEMWilcoxon Accelerometer Huddle TestI've set up the Wilcoxon accelerometers
on the SP table for a huddle test, to estimate
their noise levels. 
 AccHuddle.jpg 
  11346   Fri Jun 5 11:59:59 2015 ericqBureaucracyGeneralMaintenance Tasks, IFO upgradesAt wednesday's
meeting, Rana, Koji, Steve, and I started
making a list of maintenence tasks that should
  
  11347   Mon Jun 8 15:51:31 2015 ericqUpdateCDSRCG DiagnosticsI've started making some model changes
for RCG diagnostic tests. 

I put some blocks down in C1TST
 newTST.png 
  11349   Tue Jun 9 10:57:12 2015 SteveUpdateSUS BS oplev laser tunedLenses removed from oplev beam path at
elog entry 11246

 
 100dBStrend0425.png18dBSdrift.png 
  11350   Wed Jun 10 02:50:39 2015 ericqUpdatePEMWilcoxon Accelerometer Huddle TestHere are some results for the 3-corner
hat subtraction for the six accelerometers,
from ~1 hour of data that didn't
 hats2Acc.png3hatcode.zip 
  11351   Wed Jun 10 03:19:58 2015 ericqUpdateLSCAUX PDH error measured in CDSLooking over the old noise budget in the
green locking paper, it seems the main technical
noise sources were the AUX PDH error and
 AUXspectra.png 
  11352   Wed Jun 10 15:54:14 2015 SteveUpdateVACVacuum comp. rebootedKoji and Steve succeded rebooting C1vac1,
C1vac2 and pressure reading is working now

More tomorrow .........
 afterReb061015.png 
  11353   Thu Jun 11 19:40:59 2015 KojiUpdateVACVacuum comp. rebootedThe serial connections to the vacuum gauges
were recovered by rebooting c1vac1 and c1vac2.

Steve claimed that the vacuum screen
  
  11354   Fri Jun 12 08:40:17 2015 SteveUpdateVACVacuum comp. rebootedKoji and Steve,

One computer expert and one vacuum
expert required.
 vacMonNoGauges.pngprepReboot.png 
  11355   Fri Jun 12 17:09:58 2015 ericqUpdateLSCBeatbox needs whitening gainShort entry just to preview a new development;
more detail about this investigation will
soon follow. 
 beatGain.png 
  11356   Sat Jun 13 18:37:46 2015 ericqUpdateLSCBeatbox needs whitening gainHere are the promised details!

I was worried about the lack of
whitening gain, as I saw that the DC phase
 ADCdiagnosis.png 
  11357   Sat Jun 13 23:52:14 2015 ericqUpdateLSCBeatbox needs whitening gainNice find!

We ought to use our noise model
of the ALS signal chain to determine what
  
  11358   Mon Jun 15 11:54:44 2015 ericqUpdateCDSParts not in SVNI ran the following command to find which
models/parts are not under version control,
or have modifications not commited:
  
  11359   Mon Jun 15 16:55:39 2015 ericqUpdatePEMAccelerometers installedThe accelerometers have been installed
at MC1 and MC2. MC2 data is live, I haven't
yet run the cables from the MC1 set to the
 MC2.jpgMC1.jpgmc2accspectra.png 
  11360   Mon Jun 15 20:36:48 2015 ranaUpdateIOOIOO QPDs centredafter re-aligning the beam into the PMC,
I touched up the steering mirros into the
IOO QPDs so that the beams are now centered
 Untitled.png 
  11361   Mon Jun 15 22:36:40 2015 rana, kojiUpdateGreen LockingBeatBox Assay: not looking goodBecause the ALS beatbox schematic is out-of-date
and misleading, we pulled the box to photograph
the current implementation and figure out
  
  11362   Wed Jun 17 15:31:50 2015 ericqUpdatePEMAccelerometers fully installedMC1 accelerometer has been plugged in.
The modecleaner locking has been intermittent
today, but I looked at a 15 minute lock in
 IMCcoherence_Jun172015.xml.zipIMCcoherence.png 
  11363   Fri Jun 19 01:24:26 2015 rana, kojiUpdateGreen LockingBeatBox Assay: not looking goodWe had decided a few days ago, to bypass
the IF part of the BeatBox board and put
some of the Haixing Maglev generic filter
  
  11364   Fri Jun 19 01:55:35 2015 ericqUpdateGreen LockingBeatBox Assay: not looking good


  
  11365   Fri Jun 19 03:00:56 2015 ericqUpdateCDSLibrary Model Parts examinedAll simulink diagrams being used at the
40m are now under version control. I have
compiled, installed, and restarted all current
  
  11366   Fri Jun 19 16:54:20 2015 JenneUpdateComputer Scripts / ProgramsWiener scripts in scripts directoryI have put the Wiener filter scripts into 
/opt/rtcds/caltech/c1/scripts/Wiener/ 
  
  11367   Sun Jun 21 13:21:03 2015 ranaUpdatePEMWilcoxon Accelerometer Huddle TestTo improve our sensor
noise estimate, the ACC cables should
be clamped using a rubber pad and a big dog
  
  11368   Mon Jun 22 12:57:09 2015 ericqSummaryLSCX/Y green beat mode overlap measurement redoneI took measurements at the green beat setup
on the PSL table, and found that our power
/ mode overlap situation is still consistent
  
  11369   Mon Jun 22 14:21:42 2015 SteveMetaphysicsTreasureJenne and Den graduatedLast supper before departing at  "Grazie"
El Portal. All the best on your journey!
 ls.jpg 
  11370   Mon Jun 22 14:53:37 2015 ranaSummaryLSCX/Y green beat mode overlap measurement redone
Why is there a factor of 20 power
difference? Some of it is the IR laser power
difference, but I thought that was just a
  
  11371   Mon Jun 22 20:59:19 2015 ericqUpdateLSCDFD Delay lengthI've been thinking a bit about what
the ideal cable length / delay time for the
upgraded ALS beatbox should be. Here are
  
  11372   Tue Jun 23 11:18:20 2015 SteveUpdatePEMcleaning around chambersKeven is our regular janitor is out for
a few weeks.

The sub is careful- gentel Mario.
  
  11373   Wed Jun 24 08:05:43 2015 SteveUpdatePSLlaser turned onThe laser went off around 11am yesterday.
It was turned on
 laserWasOff.png 
ELOG V3.1.3-