ID Date Author Type Categoryup Subject Text Attachments
  15481   Tue Jul 14 17:28:29 2020 gautamUpdateLSCLocking with POX for CARMFrom Attachment
#1, looks like the
 PRFPMI_2020712sensMat.pdfLSCerrSigs.pdf 
  15714   Mon Dec 7 14:32:02 2020 gautamUpdateLSCNew demod phases for POX/POY lockingIn favor of keeping the same servo gains,
I tuned the digital demod
phases for the POX and POY photodiode signals
 POX_POY_OLTF.pdfPOX_POY_spectra.pdf 
  15715   Mon Dec 7 22:54:30 2020 gautamUpdateLSCModulation depth measurementSummary:

I measured the modulation depth
at 11 MHz andf 55 MHz using an optical beat
 modDepth.pdf 
  15718   Wed Dec 9 12:02:04 2020 gautamUpdateLSCPOX locking still unsatisfactoryContinuting the IFO recovery - I am unable
to recover similar levels of TRX RIN as I
had before. 
 armRIN.pdfPOX_OLTF.pdf 
  15750   Wed Jan 6 19:00:04 2021 gautamUpdateLSCPhase loss in POX/POY loopsI've noticed that there is some phase
loss in the POX/POY locking loops - see 
 POXloop.pdfloopFit.pdf 
  15768   Fri Jan 15 17:04:45 2021 gautamUpdateLSCMessed up LSC sensingI want to lock the PRFPMI again (to commission
AS WFS). Have had some
success - but in doing characterization,
 PRFPMI_Jan12sensMat.pdfPRMI3f_ALS_Jan11_largeOffsetsensMat.pdf 
  15769   Sat Jan 16 18:59:44 2021 gautamUpdateLSCModulation depth measurementI decided to analyze the data I took in
December more carefully to see if there are
any clues about the weird LSC sensing.
 PLL.pdfmodDepth.pdfmodProfile.pdfEOMpath_postMod.pdf 
  15822   Fri Feb 19 13:38:26 2021 gautamUpdateLSCPRFPMII forgot that I had already done some investigation
into recovering the PRFPMI lock after my
work on the RF source. I don't really
  
  15827   Fri Feb 19 18:22:42 2021 ranaUpdateLSCPRFPMI sensiing matrix woesI would:


look at the free swingin
michelson. Should be able tu null that siggnal
  
  15849   Sun Feb 28 16:59:39 2021 rana, gautamUpdateLSCmore PRMI checks here: what it is ain't exactly clearOn Friday evening we checked out
a few more things, somewhat overlapping with
previous tests. All tests done with PRMI
 RAMestimate.png 
  15850   Sun Feb 28 22:53:22 2021 gautamUpdateLSCmore PRMI checks here: what it is ain't exactly clearI looked into this a bit more and crossed
off some of the points Rana listed. In order
to use REFL 55 as a sensor, I had to fix
 PRMI_SBres_REFL55.pngPRMI1f_noArmssensMat.pdfPRMI1f_noArmssensMat.pdfPRMI_locked.pngactTFs.pdf 
  15853   Mon Mar 1 16:27:17 2021 gautamUpdateLSCPRM violin filter excessive?The PRM violin filter seems very suboptimal
- the gain peaking shows up in the MICH OLTF,
presumably due to the MICH-->PRM LSC output
 violins.pdfPRviolin.pdf 
  15854   Tue Mar 2 13:39:31 2021 ranaUpdateLSCPRM violin filter excessive?agreed, seems excessive. I always prefer
bandstop over notch in case the eigenfrequency
wanders, but the bandstop could be made to
  
  15855   Tue Mar 2 19:52:46 2021 gautamUpdateLSCREFL55 demod board reworkThere were multiple problems with the REFL55
demod board. I fixed them and re-installed
the board. The TFs and noise measured on
  
  15859   Wed Mar 3 22:13:05 2021 gautamUpdateLSCREFL55 demod board reworkAfter this work, I measured that the orthogonality
was poor. I confirmed on the bench that the
PQW-2-90
  
  15861   Thu Mar 4 10:54:12 2021 Paco, AnchalSummaryLSCPOY11 measurement, tried to lock Green Yend laser[Paco, Anchal]

- First ran burtgooey as last time.

- Installed pyepics on base environment
 20210304_POY11_Spectrum_YARMLocked.pdf20210304_POY11_Spectrum_YARMLocked.tar.gz 
  15862   Thu Mar 4 11:59:25 2021 Paco, AnchalSummaryLSCWatchdog tripped, Optics damped backGautam came in and noted that the optics
damping watchdogs had been tripped by a >5
magnitude earthquake somewhere off the coast
  
  15864   Thu Mar 4 23:16:08 2021 KojiUpdateLSCREFL55 demod board reworkA new hybrid splitter (DQS-10-100) was
installed. As the amplification of the final
stage is sufficient for the input level of
 D990511-00_REFL55.pdfP_20210304_215602.jpgP_20210304_222400.jpgP_20210304_222412.jpg20210304234400_IMG_0526.jpg 
  15867   Fri Mar 5 13:53:57 2021 gautamUpdateLSCREFL55 demod board rework0 dBm ~ 0.63 Vpp. I guess there is ~4dB
total loss (3dB from splitter
and 1dB from total excess loss above theoretical
  
  15869   Fri Mar 5 15:31:23 2021 KojiUpdateLSCREFL55 demod board reworkMissed to note: The IF test was done at
TP7 and TP6 using pomona clips i.e. brefore
the preamp.
  
  15871   Fri Mar 5 16:24:24 2021 gautamUpdateLSCREFL55 demod board re-installed in 1Y2I don't have a good explanation why,
but I too measured similar numbers to what
Koji measured. The overall conversion gain
 REFL55.pdfdemodNoise.pdf 
  15873   Fri Mar 5 22:25:13 2021 gautamUpdateLSCPRMI 1f SB locking recoveredNow that the REFL55 signal chain is capable
of providing balanced, orthogonal readout
of the two quadratures, I was able to recover
 PRMI1f_noArmssensMat.pdf 
  15874   Sat Mar 6 12:34:18 2021 gautamUpdateLSCSensing matrix settings messed withTo my dismay, I found today that somebody
had changed the oscillator frequencies for
the sensing matrix infrastructure we have.
 sensMat.png 
  15875   Sun Mar 7 15:26:10 2021 gautamUpdateLSCHousekeeping + more PRMI
Beam pointing into PMC was tweaked
to improve transmission.
AS110
photodiode was re-installed on the AS table
 PRMI_SBres.pngMICH_act_calib.pdf 
  15876   Sun Mar 7 19:56:27 2021 AnchalUpdateLSCSensing matrix settings messed withI understand this mst be frustrating for
you. But we did not change these settings,
knowingly atleast. We have documented all
  
  15883   Mon Mar 8 22:01:26 2021 gautamUpdateLSCMore PRMIThere are still many mysteries remaining
- e.g. the MICH-->PRCL contribution still
can't be nulled. But for now, I have
 PRMI1f_noArmssensMat.pdfPRMI3f_noArmssensMat.pdf 
  15892   Wed Mar 10 00:32:03 2021 gautamUpdateLSCPRFPMiThe interferometer can nearly be locked
again. I was unable to fully hand off control
from ALS-->RF, I suspect I may be using
 PRMI3f_ALSsensMat.pdf 
  15899   Wed Mar 10 19:58:27 2021 gautamUpdateLSCSR785 hooked up to CM boardIn preparation for later today evening.
The TT alignment wasn't visibly disturbed.
  
  15900   Thu Mar 11 01:45:42 2021 gautamUpdateLSCPRFPMi
PRM satellite box indeed seems
to have been the culprit - shortly after
I swapped it to the SRM, its shadow sensors
  
  15903   Thu Mar 11 14:03:02 2021 gautamUpdateLSCAO pathThere is some evidence of weird saturation
but the gain balancing (0.8dB) and orthogonality
(~89 deg) for the daughter board on the REFL11
 IMG_9127.HEIC 
  15906   Thu Mar 11 20:18:00 2021 gautamUpdateLSCHigh bandwidth POYI repeated the high bandwidth POY locking
experiment.


The "Q" demod
 OLGevolution.pdfinLoopSpec.pdf 
  15917   Fri Mar 12 19:44:31 2021 gautamUpdateLSCDelay lineI may want to use the delay line phase
shifter in 1Y2 to allow remote actuation
of the REFL11 demod phase (for the AO path,
  
  15918   Fri Mar 12 21:15:19 2021 gautamUpdateLSCcoronaversary PRFPMiAttachment
#1 - proof that the
 PRFPMI.pngCARM_OLTF.pdf 
  15923   Tue Mar 16 16:02:33 2021 KojiUpdateLSCREFL11 demod retrofittingI'm going to remove REFL11 demod for
the noise check/circuit improvement.

----
 IMG_0545.jpegIMG_0547.jpegD040179-A.pdfIMG_0548.jpegIMG_0550.jpeg 
  15927   Wed Mar 17 00:05:26 2021 gautamUpdateLSCDelay line BIO remote controlWhile Koji is working on the REFL 11 demod
board, I took the opportunity to investigate
the non-remote-controllability of the 
  
  15935   Thu Mar 18 01:12:31 2021 gautamUpdateLSCPRFPMi
Integrated >1
hour at RF only control, high circulating
powers tonight.


All
 DARM_OLTF_20210317.pdfCARMTF_20210317.pdfPRFPMI_Mar_17sensMat.pdf 
  15936   Thu Mar 18 07:02:27 2021 KojiUpdateLSCREFL11 demod retrofittingAttachment 1: Transfer Functions

The original circuit had a gain
of ~20 and the phase delay of ~1deg at 10kHz,
 TFs.pdfPSD.pdf 
  15942   Thu Mar 18 21:37:59 2021 ranaUpdateLSCPRMI investigations: what IS the matrix??
Locked PRMI several tmes after
Gautam setup. Easy w IFO CONFIG screen
 PXL_20210319_045925024.jpg 
  15944   Fri Mar 19 11:18:25 2021 gautamUpdateLSCPRMI investigations: what IS the matrix??From Finesse simulation (and also analytic
calcs), the expected PRCL optical gain
is ~1 MW/m (there is a large uncertainty,
  
  15949   Fri Mar 19 22:24:54 2021 gautamUpdateLSCPRMI investigations: what IS the matrix??I did all these checks today. 




 IMG_9140.jpgIMG_9141.jpgREFL55.png 
  15956   Wed Mar 24 00:51:19 2021 gautamUpdateLSCSchnupp asymmetryI used the Valera technique to measure
the Schnupp asymmetry to be 
 Lsch.pdf 
  15958   Wed Mar 24 15:24:13 2021 gautamUpdateLSCNotes on testsFor my note-taking:


Lock PRMI with ITMs as
the MICH actuator. Confirm that the MICH-->PRCL
  
  15960   Wed Mar 24 22:54:49 2021 gautamUpdateLSCNew day, new problemsI thought I'd get started on some of
the tests tonight. But I found that this
problem had resurfaced. I don't know
 PRMI3f_noArmssensMat.pdfREFL55_whtGainStepping.pngREFL55_whtGainStepping2.png 
  15977   Mon Mar 29 19:32:46 2021 gautamUpdateLSCREFL55 whitening checkoutI repeated the usual whitening board characterization
test of:


driving a signal (using
 REFL55wht.png 
  15994   Sat Apr 3 00:42:40 2021 gautamUpdateLSCPRFPMI locking with half input powerSummary:

I wanted to put my optomechanical
instability hypothesis to the test. So
 PRFPMIlock_1301464998_1301465238.pdfCARMplant.pdf 
  15996   Mon Apr 5 22:26:01 2021 gautamUpdateLSCPRMI 1f locking (no ETMs) recoveredSince it seems like the entire electronics
chain has no obvious failure, I decided to
compensate for the apparent increased optical
 PRMI_Apr5sensMat_consolidated.pdf 
  16095   Thu Apr 29 11:51:27 2021 AnchalSummaryLSCStart of measuring IMC WFS noise contribution in ar cavity length noiseTried locking the arms


Ran IFO > Configure
> ! (YARM) > Restore YARM. Nothing
  
  16101   Thu Apr 29 17:51:19 2021 AnchalSummaryLSCStart of measuring IMC WFS noise contribution in arm cavity length noiset Both arms were locked simply by using
IFO > Configure > ! (YARM) > Restore
YARM. I had to use ASS to improve the TRX/TRY
 WFS1_PIT_exc_80-100Hz_Arms_ASD.pdf 
  16104   Fri Apr 30 00:18:40 2021 gautamSummaryLSCStart of measuring IMC WFS noise contribution in arm cavity length noiseThis is the actuator calibration.
For the error point calibration, you have
to look at the filter in the calibration
  
  16108   Mon May 3 09:14:01 2021 Anchal, PacoUpdateLSCIMC WFS noise contribution in arm cavity length noiseLock
ARMs
 WFS1_PIT_Noise_Inj_Test_IMC_unlocked.pdfWFS1_PIT_Noise_Inj_Test_ARM_locked.pdf 