  13908   Fri Jun 1 01:22:50 2018 gautamUpdateLSCDRMI locking restoredAs it happened last time, the problem apparently
fixed itself - somehow the act of me disconnecting
the cables and reconnecting them seems to
 DRMI_20180531.png 
  13920   Wed Jun 6 14:36:15 2018 gautamUpdateLSCTRX clippingFor some time now, I've been puzzled
by the unreliability of the ASS_X dither
alignment servo. Leaving the servo on, TRX
  
  13927   Thu Jun 7 16:15:03 2018 gautamUpdateLSCTRX clippingI opted for the quickest fix - I raised
the height of the offending steering mirror
using a 0.25" shim. In the long term,
  
  13933   Fri Jun 8 01:58:56 2018 gautamUpdateLSCDRMI locking attempt againGiven the various changes to the IFO config
since last Thursday when I was last able
to lock the DRMI, I wanted to try once again
  
  13948   Tue Jun 12 03:22:25 2018 gautamUpdateLSCAUX laser shutteredI worked a bit on recovering the DRMI locking
again tonight. I decided to shutter the AUX
laser on the PSL table at least until I figured
  
  13952   Wed Jun 13 01:02:40 2018 gautamUpdateLSCReliable and repeatable 1f DRMI locking[koji,
gautam]

With Koji's help, I got repeatable
  
  13953   Wed Jun 13 11:17:40 2018 gautamUpdateLSCPRCL loop shape anomalyAttachment
#1 shows the measured
 PRCL_12Jun2018_WeirdShape.pdf 
  13959   Thu Jun 14 00:40:42 2018 gautamUpdateLSCPRCL loop shape anomalydon't use IN_1/IN_2: recall pizza meeting
from a few weeks back: use IN1/EXC + Al-Gebra

  
  13966   Thu Jun 14 18:09:24 2018 gautamUpdateLSCReliable and repeatable 1f DRMI lockingI finally analyzed the sensing measurement
I ran on Tuesday evening. Sensing responses
for the DRMI DOFs seems consistent with what
 DRMI1f_June14.pdf 
  13969   Fri Jun 15 00:53:21 2018 gautamUpdateLSCCalibrated MICH spectrumUsing the numbers from the sensing measurement,
I calibrated the measured in-loop MICH spectrum
from Tuesday night into free-running displacement
 C1NB_disp_40m_MICH_NB_2018-06-14.pdf 
  14152   Fri Aug 10 01:10:56 2018 gautamUpdateLSCSome vertex locking restoredFor
the first time after the whirlwind vent,
 PRMIcarrier.png 
  14160   Tue Aug 14 00:27:55 2018 gautamUpdateLSCLocking prepIn preparation for attempting some DRMI
locking, I did the following:


Slow machine reboots for
  
  14162   Tue Aug 14 02:01:12 2018 gautamUpdateLSCDRMI locking - partial successAfter tweaking the AS55 demod phase, SRM
alignment, triggering settings, I got a few
brief
 DRMI.png 
  14235   Sun Oct 7 16:51:03 2018 gautamConfigurationLSCYarm triggering changedTo facilitate Yuki's alignment of the
EY green beam into the Yarm cavity, I have changed
  
  14236   Sun Oct 7 22:30:42 2018 yukiConfigurationLSCYarm Green locking was recoveredI finished installation of optics in the
Y-end and recovered green locking. Current
ALS-TRY_OUTPUT is about 0.25, which is lower
 Pic_NewLayout1007.jpgYendGreenModeMatching.zip 
  14240   Tue Oct 9 23:03:43 2018 yukiConfigurationLSCYarm Green locking was recovered[ Yuki, Gautam, Steve ]

To align the green beam in Y-end
these hardware were installed:
 Pic_1Y4.jpgPic_PZTcable.jpg 
  14241   Wed Oct 10 12:38:27 2018 yukiConfigurationLSCAll hardware was installedI connected DAC - AIboard - PZTdriver -
PZT mirrors and made sure the PZT mirrors
were moving when changing the signal
  
  14285   Wed Nov 7 23:07:11 2018 gautamUpdateLSCDRMI locking recoveredI had some
success today. I hope that the tweaks I made
will allow working with the DRMI during the
 Screenshot_from_2018-11-07_23-05-58.pngSRCL2MICH_crosscpl.pdfPRCangularCoh_rot.pdf 
  14288   Sat Nov 10 17:32:33 2018 gautamUpdateLSCNulling MICH->PRCL and MICH->SRCLWith the DRMI locked, I drove a line in
MICH using the sensing matrix infrastructure.
Then I looked at the error points of MICH,
 sensMat_2018-11-10.pdf 
  14292   Tue Nov 13 18:09:24 2018 gautamUpdateLSCInvestigation of SRCL-->MICH couplingSummary:

I've been looking into the
cross-coupling from the SRCL loop control
 TF_sweptSineMeas.pdfdigitalDemod.pdfdigitalDemod_hist.pdfDRMI_LSCspectrogram.pdf 
  14298   Fri Nov 16 00:47:43 2018 gautamUpdateLSCMore DRMI characterizationSummary:


More DRMI characterization
was done.
I was working on trying
 PRCff.pdfDRMI_withPRCff.png 
  14313   Wed Nov 21 09:59:26 2018 gautamUpdateLSCLSC feedforward block diagramAttachment
#1 is a block diagram depicting
the pathway by which the vertex DOF control
 IMG_7173.JPG 
  14326   Fri Nov 30 19:37:47 2018 gautamUpdateLSCLSC feedforward block diagramI wanted to set up an RTCDS model to understand
this problem better. Attachment #1 is the
simulink diagram of the signal flow. The
 LSC_FF_tester.pngScreenshot_from_2018-11-30_19-41-07.pngScreenshot_from_2018-12-10_15-31-23.pngSimLSC.png 
  14339   Mon Dec 10 15:53:16 2018 gautamUpdateLSCSwept-sine measurement with DTTDisclaimer:
This is almost certainly some user error
 SimTF.pdf 
  14445   Fri Feb 8 20:48:52 2019 gautamUpdateLSCIFO recoverySeveral housekeeping tasks were carried
out today in preparation for the Y-arm loss
measurement.
 IMG_7307.JPG 
  14446   Mon Feb 11 15:41:49 2019 gautamUpdateLSCTRY 60 Hz solved - but clipping persistsRich came by the 40m to photocopy some
pages from Hobbs, and saw me working on the
60 Hz hunting. As I suspected, the problem
  
  14447   Mon Feb 11 16:38:34 2019 gautamUpdateLSCETMY OL calibration updatedSince we changed the HeNe, I updated the
calibration factors, and accepted the changes
in the SDF.
 OL_calib_ETMY_PERROR.pdfOL_calib_ETMY_YERROR.pdf 
  14459   Fri Feb 15 18:42:57 2019 gautamUpdateLSCTRY 60 Hz solved A more permanent fix than a crocodile clip was
implemented. Should probably look to do this
for the X end unit as well.
 IMG_7323.JPG 
  14704   Wed Jun 26 21:01:26 2019 gautamUpdateLSCPOX and POY lockingNow that the IMC is remaining locked for
extended periods of time, the next problem
to attack is the ASS dither alignment system.
  
  14705   Thu Jun 27 14:28:12 2019 gautamUpdateLSCPOX and POY lockingAfter a more systematic alignment effort,
I was able to get the spots better centered
on the optics (judged by eye from the analog
  
  14720   Tue Jul 2 17:34:54 2019 gautamUpdateLSCIrides opened up on EY tableIn preparation for the ASS debugging, I decided   
  14738   Tue Jul 9 18:06:05 2019 gautamUpdateLSCY-arm ASS in a workable stateThe Y-arm ASS was tuned to be in a workable
state. Basically, I followed Koji's recipe.
 ditherFreqs.pdftransRenorm.png 
  14904   Fri Sep 20 18:28:34 2019 gautamUpdateLSCY arm locking attemptI tried to lock the Y arm cavity length
to the PSL frequency using POY11_I as an
error signal. Even though I think the cavity
 POYlocking.png 
  14910   Sun Sep 29 15:58:19 2019 gautamUpdateLSCPOX locking attemptSummary:

There is no visible PDH error signal
on the POX11 channels. As a result, I am
 POXlockAttempt.png 
  14915   Mon Sep 30 14:16:43 2019 gautamUpdateLSCPOX PD checkout - solvedI confirmed that there is light incident
on the POX photodiode. So the problem must
lie downstream in the demod / whitening /
  
  14920   Tue Oct 1 21:19:51 2019 gautamUpdateLSCPRMI locked on carrierSummary:

The
 PRMIlocked.png 
  14924   Wed Oct 2 11:52:16 2019 gautamUpdateLSCPRMI Oplev loop checkoutI measured the OLTF of both the PRM Oplev
loops. Nothing odd sticks out as odd to me
in this measurement - there seems to be ~40
 PRM_OLTF.pdf 
  14926   Wed Oct 2 23:15:02 2019 gautamUpdateLSCFPMI lockingSummary:

I was able to lock the FPMI. The
lock was quite stable. However,
 FPMIlocked.png 
  14928   Thu Oct 3 11:01:18 2019 ranaUpdateLSC(PR)FPMI lockingwonder if its possible to do variable finesse
locking

Gabriele mentioned that Virgo used
  
  14933   Thu Oct 3 19:40:18 2019 gautamUpdateLSCPOX/POY imbalanceSummary:

There is an imbalance between
the POX and POY detector outputs reported
  
  14954   Tue Oct 8 18:35:09 2019 gautamUpdateLSCLocking prepIn preparation for some locking work tonight,
I did the following at the POP in air table
with the PRMI locked on carrier:
  
  14960   Wed Oct 9 18:15:26 2019 gautamUpdateLSCPRMI 3f lockingAfter making sure the beams were hitting
the 3f photodiodes on the "AP"
table, I was able to lock the PRMI with the
 PRMI_1f.png 
  14961   Wed Oct 9 22:02:58 2019 gautamUpdateLSCREFL55 whitening issueThis
problem has re-surfaced. Is this indicative
of some problem with the on-board VGA? Even
  
  14962   Thu Oct 10 01:12:56 2019 gautamUpdateLSCLocking studiesSummary:


ALS control of arms in
the CARM/DARM basis seems pretty robust -
 PRFPMIstudies.png 
  14963   Thu Oct 10 22:11:53 2019 gautamUpdateLSCTrans QPD checkout
I removed the flip-mount that was
installed on the EY in-air table for the
mode-spectroscopy project (see 
 EY_table_20191010.jpegdarkNoise.pdf 
  14973   Wed Oct 16 11:42:17 2019 gautamUpdateLSCPoor separation of PRCL/MICH in 3f signalsSummary:

There is poor separation
of the PRCL and MICH length error signals
 sensMat.pdf 
  14974   Thu Oct 17 11:19:28 2019 gautamUpdateLSCLocking activity last night
Tuning the MICH-->PRM
output matrix element


Locked
the PRMI with the carrier field resonant
 MICH2PRCLnulling.pdfconsolidatedSensingMatrices.pdf.zip 
  14983   Tue Oct 22 00:52:27 2019 gautamUpdateLSCLocking updates
Transition of arms from POX/POY
to CARM/DARM was much smoother today - a
change was made at the EX PDH setup, see
 PRMI3f_ALS_Oct21sensMat.pdf 
  14996   Tue Oct 29 01:24:45 2019 gautamUpdateLSCMore locking updatesSummary:


The two arm lengths can
be controlled reliably in the CARM/DARM basis
 POP22_feature.pngPRMI3f_ALS_Oct21sensMat.pdf 
  14997   Tue Oct 29 15:13:19 2019 gautamUpdateLSCMore locking updatesI looked at some signals for a 10 second
period when the PRMI was locked with at some
CARM offset, just before the PRMI lost lock,
 PRMI_lockloss.png 
ELOG V3.1.3-