  13952   Wed Jun 13 01:02:40 2018 gautamUpdateLSCReliable and repeatable 1f DRMI locking[koji,
gautam]

With Koji's help, I got repeatable
  
  13966   Thu Jun 14 18:09:24 2018 gautamUpdateLSCReliable and repeatable 1f DRMI lockingI finally analyzed the sensing measurement
I ran on Tuesday evening. Sensing responses
for the DRMI DOFs seems consistent with what
 DRMI1f_June14.pdf 
  17202   Thu Oct 20 19:47:24 2022 TegaUpdateCDSRelocate front-ends to Rack 1X7We mounted chiara, all front-end machines
and switches in rack 1x7; reconnected power,
dolphin, onestop and timing cables; and restarted
 IMG_20221020_193623269.jpgIMG_20221020_193637034.jpgiop_status_20221020.pngiop_status_20221020_restart_models.pngc1ioo_shm_glitch.png 
  16838   Mon May 9 18:49:05 2022 TegaUpdateBHDRelocate green TRX and TRY PDs/cams/optics from PSL table to BS table[Paco, Tega]

Started work on the relocating
the green transmission optics, cameras and
 IMG_20220509_184439943.jpgIMG_20220509_184154722.jpg 
  16842   Tue May 10 15:46:38 2022 JCUpdateBHDRelocate green TRX and TRY components from PSL table to BS table[JC, Tega]

Tega and I cleaned up the BS OPLEV
Table and took out a couple of mirrors and
 IMG_0741.jpegIMG_0753.jpeg 
  12114   Tue May 10 03:44:59 2016 ericqUpdateLSCRelockedALSX noise is solidly within past acceptable
performance levels. The DRFPMI was locked
on four out of six attempts. 
 2016-05-10_DARMcoherence.pdf 
  5271   Fri Aug 19 19:08:40 2011 JennyUpdatePSLRelocking NPRO to reference cavity. I am trying again to measure a temperature
step response on the reference cavity on
the PSL table.
  
  5272   Fri Aug 19 23:41:20 2011 JennyUpdatePSLRelocking NPRO to reference cavity.

    

       
            
  
  5468   Mon Sep 19 20:56:36 2011 PaulSummarySUSRemaining SRM and ITMY OSEMs calibrations 
I've now taken data for the pitch
and yaw calibrations for the OSEMs of SRM
 SRM_PITCH_calib_curve.pngSRM_YAW_calib_curve.pngITMY_PITCH_calib_curve.pngITMY_YAW_calib_curve.png 
  16519   Fri Dec 17 12:32:35 2021 KojiUpdateSUSRemaining task for 2021Anything else? Feel free to edit this entry.

- SUS: AS1 hanging

- SUS: PR3/SR2/LO2 3/4" thick
  
  16522   Fri Dec 17 19:19:42 2021 KojiUpdateSUSRemaining task for 2021I had the fear that any mistake in the
electronics chain could have been the show
stopper.
 PXL_20211218_030145356.MP.jpg 
  16525   Sun Dec 19 07:52:51 2021 AnchalUpdateSUSRemaining task for 2021The I/O chassis reassigns the ADC and DAC
indices on every power cycle. When we moved
it, it must have changed it from the order
  
  16534   Wed Dec 22 18:16:23 2021 KojiUpdateSUSRemaining task for 2021The in-vacuum installation team has reported
that the side OSEMs of ITMX and LO1 are going
to be interfering if place LO1 at the planned
 ITMX_2016_07_21.jpgScreen_Shot_2021-12-22_at_18.03.42.png 
  2074   Fri Oct 9 03:53:56 2009 JenneUpdateAdaptive FilteringRemaking the ASSThe c1ass computer, which is now used for
the OAF system, has many remnants from the
days when it was actually used as an ASS. 
  
  17712   Tue Jul 25 10:22:09 2023 KojiUpdatePEMRemarks on the IFO recovery after CDS restart.Yesterday during the recovery work from
the CDS restart, I found ASS was not working
for both arms. Both arms were flashing and
  
  17713   Tue Jul 25 15:06:57 2023 YehonathanUpdatePEMRemarks on the IFO recovery after CDS restart.Yes, it seems like ITMX UL sensor issue
has reared its ugly head again (see attachment).

 Screenshot_2023-07-25_15-06-17.png 
  17729   Thu Jul 27 21:39:50 2023 HirokiUpdatePEMRemarks on the IFO recovery after CDS restart.[Koji, Hiroki]

We
resotred the noisy ITMX UL sensor reported
 ITMX_SUS_Cables.jpgScreen_Shot_2023-07-27_at_9.36.52_PM.png 
  17733   Sat Jul 29 00:08:35 2023 HirokiUpdatePEMRemarks on the IFO recovery after CDS restart.[Koji, Hiroki]

We investigated the cause of the
unstable OPLEV damping in ITMX and found
 Screenshot_2023-07-29_00-23-17.pngScreenshot_2023-07-29_00-18-56.pngScreenshot_2023-07-28_22-41-00.png 
  17734   Sat Jul 29 00:44:57 2023 KojiUpdatePEMRemarks on the IFO recovery after CDS restart.I had a suspicion that some of the ITMX
coils were not properly working. So individual
coils of the 4 test masses were excited while
 ITMX_TF.pdfITMY_TF.pdfETMX_TF.pdfETMY_TF.pdf 
  11563   Thu Sep 3 00:45:25 2015 IgnacioUpdateIOORemeasured MC2 to MCL TF + Improved subtraction performanceToday, I
remeasured the transfer function for MC2
to MCL in order to improve the subtraction
 8x 
  8498   Fri Apr 26 20:43:51 2013 JenneUpdateLSCRemeasuring the Schnupp asymmetry[Jenne, Annalisa, with guidance from Koji]
We took data to remeasure the
Schnupp asymmetry, using the Valera method
  
  8528   Fri May 3 17:32:59 2013 JenneUpdateLSCRemeasuring the Schnupp asymmetryI have looked at / analyzed the Schnupp
data that Annalisa and I took last week,
as well as some more Yarm data that I took
 Xarm_SchnuppData_April2013.pngYarm_SchnuppData_April2013.png 
  17743   Tue Aug 1 21:52:46 2023 HirokiUpdatePSLRemote switching of PSL shutter is not working[Yuta, Hiroki]

Remote
switching of PSL shutter is not working.

 PSLshutterDriver.jpg 
  1738   Mon Jul 13 15:48:05 2009 ranaOmnistructureEnvironmentRemoval of the cold air deflection device for the MOPA chillerAround 2 PM today, I removed the blue flap
which has been deflecting the cold air from
the AC down into the laser chiller.
  
  1740   Mon Jul 13 23:03:14 2009 rob, albertoOmnistructureEnvironmentRemoval of the cold air deflection device for the MOPA chiller[quote]Around 2 PM today, I removed the blue
flap which has been deflecting the cold air
from the AC down into the laser chiller.
  
  1741   Tue Jul 14 00:32:46 2009 rob, albertoOmnistructureEnvironmentRemoval of the cold air deflection device for the MOPA chiller[quote][quote]Around 2 PM today, I removed
the blue flap which has been deflecting the
cold air from the AC down into the laser
  
  1745   Tue Jul 14 17:48:20 2009 JenneOmnistructureEnvironmentRemoval of the cold air deflection device for the MOPA chiller[quote][quote][quote]Around 2 PM today, I
removed the blue flap which has been deflecting
the cold air from the AC down into the laser
 ACeffectonLASER2.png 
  572   Thu Jun 26 10:56:15 2008 Max JonesUpdatePEMRemoved MagnetometerI removed the Bartington Magnetometer on the
x arm to one of the outside benches. I'll
be trying to determine if and how it works
  
  17691   Tue Jul 18 00:16:01 2023 HirokiUpdateGeneralRemoved T&R measurement setupI removed the T&R
measurement setup with permission from Radhika
 after_removal.jpg 
  7246   Tue Aug 21 22:54:47 2012 JenneUpdateLockingRemoved beam dump from POY pathPOY was looking funny, and the YARM wasn't
locking.  It looked like POY wasn't
seeing any light at all.  I went to
  
  16676   Wed Feb 23 15:08:57 2022 AnchalUpdateGeneralRemoved extra beamsplitter in MC WFS pathAs discussed in the meeting, I removed
the extra beam splitter that dumps most of
the beam going towards WFS photodiodes. 
  
  4561   Fri Apr 22 12:07:38 2011 josephb, steveUpdateCDSRemoved hanging D-sub to SCSI in 1X2Problem:
Way back, Jay had D-sub
to SCSI adapters made to adapt our existing
Sander box AA filters to the new SCSI based
  
  4590   Fri Apr 29 14:36:36 2011 josephb, steveUpdateCDSRemoved hanging D-sub to SCSI in 1X5

    

       
            
 P1070621.JPG 
  3080   Wed Jun 16 11:31:19 2010 josephbSummaryComputersRemoved scaling fonts from medm on AllegraBecause it was driving me crazy while working
on the new medm screens for the simulated
plant, I went and removed the aliased font
  
  17184   Tue Oct 11 16:52:42 2022 AnchalUpdateIOORenaming WFS channels to match LIGO site conventions[Tega, Anchal]

c1mcs and c1ioo models have been
updated to add new acquisition of data.
  
  2806   Mon Apr 19 07:38:07 2010 ranaHowToElectronicsRepair and Calibration of SR560: s/n 59650Frank noticed that this particular SR560
had an offset on the output which was unzeroable
by the usual method of tuning the trim pot
  
  9560   Thu Jan 16 21:38:13 2014 ericqUpdateLSCRepeat of PRC length measurement[ericq,Jenne]
Since we don't have agreement between
the measurements we made the other day and
  
  15966   Thu Mar 25 16:02:15 2021 gautamSummarySUSRepeated measurement of coil Rs & Ls for PRM/BSMethod

Since I am mainly concerned with
the actuator part of the OSEM, I chose to
  
  9335   Mon Nov 4 12:07:55 2013 DmassOmnistructureGeneralReplaced Broken Drill BitsI broke a small bit while using the 40m
drill press to vent some 1/4-20 screws for
the cryo experiment.
  
  9202   Fri Oct 4 12:33:27 2013 MasayukiUpdateSUSReplaced the laser for Optical Lever of ETMY [Steve, Masayuki]
We replaced the laser for optical
lever of ETMY. And also we aligned the path
 OPLEV_SUM.pdfETMYoplev.png 
  9203   Fri Oct 4 14:36:44 2013 ranaUpdateSUSReplaced the laser for Optical Lever of ETMY   That's good, but please no
more Oplev work. We want to do all of
it at once and to make no more changes until
  
  9206   Sun Oct 6 18:37:43 2013 ranaUpdateSUSReplaced the laser for Optical Lever of ETMY I centered the ETMY OL today and found
that the UGF was around 3-4x too LOW after
the laser swap and re-alignment. That's why
 web-burnt-toast.jpg 
  9212   Mon Oct 7 10:51:18 2013 SteveUpdateSUSReplaced the laser for Optical Lever of ETMY  Just plot.
RA: I'm not
 ETMXoplevETMY.pngoplevSettings.png 
  8125   Wed Feb 20 23:25:50 2013 ZachSummaryElectronicsReplacement for the AD743: OPA140 and OPA827I have found two great FET input chips  ULN_opamp_comparison_2_20_13.png 
  8151   Sat Feb 23 18:01:38 2013 ZachSummaryElectronicsReplacement for the AD743: OPA140 and OPA827Rana suggested that I measure the OPA827
and OPA140 noise with high source impedance
so as to see if we could find the low-frequency
 OPA140_OPA827_noise_vs_Rs.pngScreen_Shot_2013-02-24_at_12.12.23_PM.pngScreen_Shot_2013-02-24_at_12.12.43_PM.png 
  8153   Sun Feb 24 16:49:00 2013 ranaSummaryElectronicsReplacement for the AD743: OPA140 and OPA827  This looks pretty good already.
Not sure if we can even measure anything
reasonable below 0.1 Hz without a lot of
  
  12239   Fri Jul 1 17:51:28 2016 PrafulSummaryElectronicsReplacing DIMM on OptimusThere has been an ongoing memory error
in optimus with the following messages:

controls@optimus|~
  
  12275   Fri Jul 8 15:44:07 2016 PrafulUpdateElectronicsReplacing DIMM on OptimusOptimus' memory errors are back so
I found the exact DIMM model needed to replace:
http://www.ebay.com/itm/Lot-of-10-Samsung-4GB-2Rx4-PC2-5300P-555-12-L0-M393T5160QZA-CE6-ECC-Memory-/201604698112?hash=item2ef0939000:g:EgEAAOSwqBJXWFZh
  
  12613   Mon Nov 14 14:21:06 2016 gautamSummaryCDSReplacing DIMM on OptimusI replaced the suspected faulty DIMM earlier
today (actually I replaced a pair of them
as per the Sun Fire X4600 manual). I did
  
  12615   Mon Nov 14 19:32:51 2016 ranaSummaryCDSReplacing DIMM on OptimusI did apt-get update and then apt-get upgrade
on optimus. All systems are nominal.
  