40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 221 of 344  Not logged in ELOG logo
ID Date Author Type Category Subjectup
  3094   Mon Jun 21 18:01:34 2010 JenneUpdate40m UpgradingSRM, PRM hung, magnets inspected

[Jenne, Kiwamu, Rana, Eric Gustafson]

The SRM and PRM have been re-hung, and are ready for installation into the chambers.  Once we put the OSEMs in, we may have to check the rotation about the Z-axis.  That was not confirmed today (which we could do with the microscope on micrometer, or by checking the centering of the magnets in the OSEMs).

Also, Eric and Rana inspected the Tip Tilt magnets, and took a few that they did their best to destroy, and they weren't able to chip the magnets.  There was concern that several of the magnets showed up with the coatings chipped all over the place.  However, since Rana and Eric did their worst, and didn't put any new chips in, we'll just use the ones that don't have chips in them.  Rana confiscated all the ones with obvious bad chips, so we'll check the strengths of the other magnets using a gaussmeter, and choose sets of 4 that are well matched. 

Eric, photographer extraordinaire, will send along the pictures he took, and we'll post them to Picasa.

  4655   Fri May 6 17:11:55 2011 steveUpdateSUSSRM-oplev cable

The SRM qpd cable was removed from the BS-table. It's path was changed from 1x4 to ITMY-table following the inner cable tray.

  4687   Wed May 11 11:24:59 2011 steveUpdateSUSSRM-oplev qpd is back

Quote:

The SRM qpd cable was removed from the BS-table. It's path was changed from 1x4 to ITMY-table following the inner cable tray.

 Laser diode oplev SRM is working. Qpd matrix values were reset like others.

In 0.44mW, returning 0.1mW,  -500 counts.

  2862   Fri Apr 30 23:16:51 2010 KojiUpdateSUSSRM/PRM ready for baking

Kiwamu and Koji

- Checked the SRM/PRM balancing after the gluing.

- The mirrors were removed from the suspensions for baking.

- Bob is going to bake them next week.

  10694   Mon Nov 10 23:14:20 2014 ranaSummarySUSSRM: damping gains & Optical Lever servo Tune-up
  1.  tweaked gains for POS, PIT, YAW, SIDE by ~10-20% to get nice ringdowns with Q~5.
  2. Measured bounce rool freqs = 16.43 / 23.99 Hz. Updated the Mech Res Wiki page. Tightened up the bandstops to get back a few deg of phase. Propagated these new bandstops into the SRM SUS damping filter banks.
  3. Made and turned on a LP filters for the loops.
  4. Added a ~0.3 Hz gain boost / bubble.
  5. Set UGF to be ~2.5x below where it rings up. Estimate this to be ~3.5 Hz.
  6. First PDF shows bounce/roll peaks in OSEMs. Notice how f_roll is > sqrt(2)*f_bounce. ??
  7. Second PDF shows the OL spectra with the loops on/off. Previously there was no Boost and no LP (!!) turned on.
  8. 3rd PDF shows the modeled Bode plot of the OLG. yellow/blue is boost off/on
  1134   Fri Nov 14 11:33:19 2008 steveUpdateVACSRS-RGA installed
Old Dycor rga is removed and new SRS-RGA200 installed.
It is pumped down and ready for hooking up its RS-232 output for operation.
  7925   Tue Jan 22 11:09:58 2013 SteveUpdateTip - TiltSS mirror holder ordered

Koji's design of the SS  2" mirror holder with flexure spring optic retainer  like Polaris-K1 has been ordered. We are getting just one to see it's effect on the hysteresis.

  550   Fri Jun 20 17:42:48 2008 steveUpdatePSLSS trap scattering compared to black glass trap
Circular SS304 trap was compared to wedged black glass trap.

The measurement set up of entry 529 was changed to define polarization.
CrystaLaser was remounted in horizontal position and half wave plate was placed after it.
These measurements were done in horizontal polarization.

atm1: the cSSt and wBGt was moved horizontally, ~90 degrees of the incident beam
atm2: traps were rotated around the incident beam, ~20 degrees each direction
atm3: set up
atm4: top view of traps
atm5: side view of trap
  14197   Wed Sep 12 22:22:30 2018 KojiUpdateComputersSSL2.0, SSL3.0 disabled

LIGO GC notified us that nodus had SSL2.0 and SSL3.0 enabled. This has been disabled now.
The details are described on 40m wiki.

  7   Mon Oct 22 12:02:59 2007 ajwRoutineGeneralSTACIS as microseismic shaker
In case we ever want to use our Stacis systems as shakers, check this:
link
  7231   Sun Aug 19 19:56:20 2012 YaakovUpdateSTACISSTACIS signal box made

I made the signal box as described in eLog 7210. It adds the geophone signal and an external signal.

It has six switches, for x, y, and z signals from both an external and local (geophone) source. The x signals add if both x switches are flipped down (and the same for the other directions). For example, if you want to feed in only an external signal in the x direction, flip down the external x direction switch (it's labeled on the box), leaving all others flipped up.

The x, y, and z outputs are wired to the pins from the preamplifier that go to the high voltage board. These I disconnected from the preamplifier by cutting at their base (there are spare connectors if this wants to be undone, or, a wire can just be soldered from the pin to its old spot on the board). The power (plus/minus) and ground are wired to the respective pins from the geophone preamplifier (naturally, the STACIS must be turned on for the box to work since the box shares its power source). Below, the front (switches and geophone/external inputs) and back (power, ground, outputs) of the box are shown:

SAM_0276.JPGSAM_0277.JPG

The preamplifier can plug into its regular connectors- the x,y,and z signals will all be redirected to the signal box with these modifications. The box sits outside the STACIS, there is room to feed the wires out from underneath the STACIS platform.

SAM_0275.JPG

NOTE: The geophone z switch is a little different than the others, just make sure it's flipped all the way down if you want that signal to be seen in the z output.

 

  7258   Thu Aug 23 15:42:48 2012 ranaUpdateSTACISSTACIS signal box made

 

 I found this entry in the old 40m ilog which describes the STACIS performance. It shows that even though the STACIS is bad for the differential arm motion below 3 Hz. It has quite a big and positive effect at 10-30 Hz. The OSEMs show a bigger effect than what the single arm does. I think this is because the single arm is limited by the MC frequency noise above 10 Hz.

We should figure out how to turn on the STACIS but set the lower UGF to be ~5 Hz.

  2428   Thu Dec 17 17:13:50 2009 AlbertoOmnistructureEnvironmentSTACIS stuff
One of the electronics benches is currently occupied by the STACIS equipment.
We need that table If no one is working on the STACIS anymore, it should be removed from there.
  16885   Wed Jun 1 12:56:44 2022 PacoSummaryElectronicsSTEMlab 125 handout

[Paco, Deeksha]

Yesterday I handed Deeksha a red pitaya (stemlab 125 - 10) to begin her summer work in the lab. The short term goal (~1 week) is to get it to work as a network analyzer and perhaps characterize its ADC/DAC noise spectra.

  6981   Tue Jul 17 18:00:58 2012 MashaUpdatePEMSTS

Den and investigated the STS-1 problem (which is currently plugged into ADC channels 13, 14, and 15, which correspond to the STS-3 channels in dtt). It turns out that I had plugged in the power to the monitor in the host box rather than the remote. The X, Y, and Z readout is currently approaching a mean of zero, and I will let it continue to do so overnight (pressing auto-zero as necessary). Attached is a plot of the coherence with GUR 1, and the time-domain signals.

  6987   Wed Jul 18 11:05:40 2012 MashaUpdatePEMSTS Coherene

I realized what the ADC channel mismatch was, and apologize for plotting a terrible coherence in log scale. The channels are now properly matched (there is decent coherence between GUR1_X/STS_X, etc.).

  6499   Fri Apr 6 19:04:35 2012 JenneUpdatePEMSTS releveled, GUR2 plugged in

[Den, Jenne]

We were wondering why the STS-2 signal was funny.  When I went to look at it, the X-axis indicator was pointing ~45deg from the x-axis, so that it was pointing between the arms of the IFO.  Also, the bubble in the level was totally stuck on one side.  We locked the masses, and I put the seismometer back to the correct orientation, and then leveled it.  We unlocked the masses and turned the power back on, and hit the auto-zero button a few times.  Right now the X-axis signal is fine, but Y and Z are still railed, but it's been like 24 seconds, not 24 hours since we last hit auto zero, so there's still some time to wait.

Also, GUR2 was unplugged on both ends of the cable.  We plugged it back in.  However, it looks like the *seismometer* labeled #1 is now plugged into *channels* GUR2, and the seismometer labeled #2 is plugged into channels GUR1.  Recall that Den has only modified X, Y, Z for GUR1 channels, not any other channels in the breakout box.

  7080   Thu Aug 2 22:52:23 2012 MashaConfigurationPEMSTS, GUR2, and Trillium in isolation box.

Den and I moved the Streckeisen, Guralp 2, and Trillium seismometers to the isolation box in order to measure the noise of the Streckeisen while we have the Trillium.

  6977   Mon Jul 16 11:50:56 2012 MashaUpdatePEMSTS-1

It seems that the STS-1 ADC channels had the same mismatch issue as the GUR-2 channels. The PEM_MONITOR has STS_1 listed as channels 6, 7, 8 (+1 on the actual ADC) whereas it was plugged into channels 13, 14, 15 (+1 on the actual ADC as well) with nothing in channels 6, 7, 8. Thus, I moved the cables and reset STS_1. The readout, however, is still only a magnitude of ~10 counts (I checked, however, that this is indeed the readout when the seismometer is plugged in vs. when it is unplugged), but hopefully it will stabilize during the day, as did GUR 2.

  5059   Fri Jul 29 12:25:54 2011 Ishwita, ManuelUpdatePEMSTS-2 seismometer box

The 'Bacardi' STS-2 seismometer was tested with the "purple" breakout box and it was found out that all the three axes gave a voltage of 11 V (as shown on the screen of the oscilloscope) before pressing the auto-zero button and after pressing it the voltage shown was 6 V. We tried again the blue box and it was working perfectly after pushing the auto zero button (the auto zero took a few seconds). The power of the purple box is still on, we will wait a few hours, to see if something changes.

  5018   Fri Jul 22 14:22:13 2011 Ishwita, ManuelUpdatePEMSTS-2 seismometer hardware testing

We have two STS-2 seismometer boxes... the blue box & the purple box. Initially we used the blue box for the STS-2 seismometer (named Bacardi by Jenne).

  • Oscilloscope powered on battery was used to test the blue box by observing the velocity output of the three axes (X, Y, Z).  It was found out that the mean value of DC volt of...

X = +10 V

Y = +11 V

Z = -0.1 V

Thus, X and Y axes showed abnormally high DC volt. It was also found out that in AC coupling mode of the oscilloscope... changes were observed in the signal received from Z axis when some seismic wave was generated near the Bacardi by jumping near it. No such changes were observed from signals received from X & Y axes.

  • We removed the blue box and used the purple box for the same Bacardi seismometer & used the oscilloscope powered on battery to test it. It was found out that the mean value of DC volt of...

X = +4.4 V

Y = +4.4 V

Z = +4.4 V

In Ac coupling mode of the oscilloscope... changes were observed in the signals from X, Y, Z axes when someone jumped near Bacardi.

  • The above voltages from the two STS-2 seismometer boxes are unsuitable for the ADC box since it works with voltages ranging from +2 V to -2 V.... meaning it will consider any voltage signal above +2 V as +2 V and any signal below -2 V as -2 V. Hence we need to find out how to use these STS-2seismometer boxes with the ADC box.
  • We also tried measuring the DC volt from the shield and the center of a BNC connector corresponding to Y axis of the purple box (lets call it 'BNC-test') by using BNC-to-banana adaptors and banana wires. Signal from shield of BNC-test was sent to oscilloscope's channel 1 (connected to center of its BNC connector) and signal from center of BNC-test was sent to oscilloscope's channel 2 (connected to center of its BNC connector). On the oscilloscope screen it was observed that both the signals gave the same mean voltage output (-2.2V).
  5033   Mon Jul 25 18:51:38 2011 ManuelUpdatePEMSTS-2 seismometer hardware testing with Jan

[Jan, Manuel, Jenne]

Jenne called Jan to check and figure out why the Streckeisen seismometer (SN #100151) doesn't work, hence we checked the output of the seismometer boxes as we did last friday. (This is the problem of seeing the X and Y channels saturated, when we look at them on a floating 'scope, as in the linked elog entry.)

Jan unplugged and plugged again the orange cable into the seismometer and nothing happened.   Well, what Jan was listening for was "clicks" inside the seismometer indicating that it was receiving power.  We heard these, and moved on to examining the breakout boxes.  Also, we checked that we could hear the "clicks" (one per mass) when we pushed the mass-centering button on the little green companion box.

We weren't sure that the purple box was working properly, so since we had seen the blue box work last time, we changed the purple box with the blue box in rack 1X6.

The Z-channel of the purple box returns a correct signal, that means that all the masses in the seismometer work (because the Z-signal is a linear combination of the three masses U, V, W), the X and Y channel have a DC component of about 10 Volts, Jan said that the recentering of the seismometer masses could need all the night, so we keep the power of the box on. If tomorrow morning the X and Y signal won't  both be zero mean, we will open and check the box.

The power of the box is still on so that the masses can recenter overnight.

Edits by JD

  5213   Fri Aug 12 17:05:22 2011 Manuel, IshwitaConfigurationPEMSTS2 Cable configuration

The WWF_M connector is the end of the STS2 seismometer orange cable and the S1 connector is the end of the gray 26-pin-cable

01050901.PDF

  4484   Mon Apr 4 11:52:13 2011 JenneUpdatePEMSTS2s unpacked

I unpacked the STS2 seismometers that we borrowed from LLO.  They are sitting underneath the Xarm, in the middle of the mode cleaner, near the other seismometer stuff. 

  6880   Wed Jun 27 11:35:06 2012 SashaSummaryComputer Scripts / ProgramsSURF - Week 1 - Summary

I started playing with matlab for the first time, accurately simulated a coupled harmonic oscillator (starting from the basic differential equations, if anyone's curious), wrote a program to get a bode plot out of any simulation (regardless of the number of inputs/outputs), and read a lot.

I'm currently going through the first stage of simulating an ideal Fabry-Perot cavity (I technically started yesterday, but yesterday's work turned out to be wrong, so fresh start!), and other than yesterday's setback, its going okay.

I attached a screenshot of my simulation of the pitch/pendulum motion of one of the mirrors LIGO uses. The bode plots for this one are turning out a little weird, but I'm fairly certain its just a computational error and can be ignored (as the simulation matlab rendered without the coupling was really accurate - down to a floating point error). I have also attached these bode plots. The first bode is based on the force input, while the second is based on the torque input. It makes sense that there are two resonant frequencies, since there ought to be one per input.

 

  6957   Wed Jul 11 10:17:18 2012 SashaSummarySimulationsSURF - Week 2 and 3 - Summary

These past two weeks, I've been working on simulating a basic Fabry-Perot cavity.  I finished up a simulation involving static, non-suspension mirrors last week. It was supposed to output the electric field in the cavities given a certain shaking (of the mirrors), and the interesting thing was that it outputted the real and imaginary components seperately, so I ended up with six different bode plots. Since we're only interested in the real part, bodes 2, 4, and 6 can be discarded (see attachment 1). There was a LOT of split-peak behavior, and I think it has to do either with matlab overloading or with the modes of the cavity being very close together (I actually think the first is more likely since a smaller value of T_1 resulted in actual peaks instead of split ones).

At any rate, there really wasn't much I could improve on that simulation (neither was there any point), but I attach the subsystem governing the electric field in the cavity as a matter of academic interest (see attachment 2). So I moved onto simulations where the mirrors are actually suspended pendulums as they are in reality.

 

A basic simulation of the suspended mirrors gave me fairly good results (see attachment 3). A negative Q resulted in a phase flip, detuning the resonance from the wrong side resulted in a complete loss of the resonance peak, and the peak looked fairly consistent with what it should be. The simulation itself is pretty bare bones, and relies on the two transfer functions P(s) and K(s); P(s) is the transfer function for translating the force of the shaking of the two test masses (lumped together into one transfer function) into actual displacement. Note that s = i*w, where w is the frequency of the force being applied. K(s), on the other hand, is the transfer function that feeds displacement back into the original applied force-based shaking. Like I said, pretty bare bones, but working (see attachment 4 for a bode plot of a standard detuning value and positive Q). Tweaking the restoring (or anti restoring, depending on the sign of the detuning) force constant (K_0 for short) results in some interesting behavior. The most realistic results are produced for K_0 = 1e4, when the gain is much lower overall but the peak in resonance gets you a gain of 100 in dB.  For those curious as to where I got P(s) and K(s), see "Measurement of radiation-pressure-induced optomechanical dynamics in a suspended Fabry-Perot cavity" by Thomas Corbitt, et. al.

I'm currently working on a more realistic simulation, with frequency and force noise as well as electronic feedback (via transfer functions, see attachment 5). The biggest thing so far has been trying to get the electronic transfer functions right. Corbitt's group gave some really interesting transfer functions (H_f(s) and H_l(s) for short; H_f(s) gives the frequency-based electronic transfer function, while H_l(s) gives the length-based electronic transfer function), which I've been trying to copy so that I can reproduce their results (see attachment 6). It looks like H_l(s) is a lowpass Butterworth filter, while H_f(s) is a Bessel filter (order TBD). Once that is successful, I'll figure out what H_f(s) and H_l(s) are for us (they might be the same!), add in degrees of freedom, and my first shot at the OSEM system of figuring out where the mirror's position is.

 

  6985   Wed Jul 18 09:53:20 2012 SashaSummarySimulationsSURF - Week 4 - Summary

This past week, I've been working on moving forward with the basic cavity model I developed last week (for future reference, that model was FP_3, and I am now working on FP_4) and refining the suspensions. I added three degrees of freedom to my simulation (such that it now consists of yaw, pitch, displacement, and side-to-side motion) and am attempting to integrate them with the OSEMS. I have also added mechanical damping for all degrees of freedom, and am adding electric damping and feedback. Concerning that, are all of the degrees of freedom locally damped in addition to being actuated on by the control system? Or does the control system do all of the damping itself? The first is the way I'm working on setting it up, but can easily change this if needed.

The next iteration of FP (FP_5) will replace my complicated OSEM --> Degrees of Freedom and vice versa system with the matrix system (see the poster Jenne and Jamie made, "Advanced Suspension Diagnostic Procedure"), as well as adding bounce/roll, yaw/y coupling, various non-damping filters as needed (i.e. the a2f filters), and noise sources. However, I'll only move on to that once I'm sure I have FP_4 working reasonably well. For now at least, the inputs/outputs look fine, and some of the DOF show resonance peaks. I'll become more concerned about where these resonance peaks actually are once I add damping.

Attached is a screenshot my work in progress. Only one of the suspensions has a basic feedback/damping loop going (as a prototype). It looks complicated now, but will simplify dramatically once I have damping worked out. Pink inputs are noises (will probably replace those with noise generators in FP_5) and green inputs are the OSEMS. The red output is the displacement of the cavity from resonance. The blue boxes are suspensions.

  7022   Wed Jul 25 10:31:33 2012 SashaSummarySimulationsSURF - Week 5 - Summary

This week I've been working on refining my simulation and getting it ready to be plugged into the control system. In particular, I've added a first attempt at a PDH control system, matrix conversion from OSEMs to DOF and back, and all necessary DAC/ADC/AA/AI/whitening/dewhitening filters. Most of these work well, but the whitening filters have been giving me trouble. At one point, they were amplifying the signal instead of flatting it out, such that my simulation started outputting NaN (again).

This was wholeheartedly depressing, but switching out the whitening filters for flat ones seemed to make the problem go away, but brought another problem to light. The output to input ratio is minuscule (as in 10^-300/10^243, see Attachment 3 for the resulting bode plot between a force on the suspension pt in the x-direction and my two outputs - error signal and length signal, which is pretty much what you would expect it to be). I suspect that its related to the whitening filter problem (perhaps the dewhitening filter is flattening the signal instead of amplifying?). If that is the case, then switching the whitening/dewhitening filters ought to work. I'll try today and see what happens. The white/dewhite filters together result in a total gain of 1, which is a good fundamental test, but could mean absolutely nothing (i.e. they could both be wrong!). Judging from the fact that we want to flatten out low frequency signal when it goes through the whitening filter, the filters don't look switched (see Attachment 4 for a bode plot of white and dewhite).

The only other source of problems (given that the suspensions/local damping have been debugged extensively throughout this process - though they could bug out in conjunction with the cavity controls?) is the PDH system. However, separating each of the components showed that the error signal generated is not absurd (I haven't tested whether it makes sense or not, but at any rate it doesn't result in an output on the order of 10^-300).

In summary, I've made progress this week, but there is still far to go. Attachment 1 is my simulation from last week, Attachment 2 is my simulation from this week. A talk with Jamie about the "big picture" behind my project helped tremendously.

  7028   Wed Jul 25 14:35:45 2012 SashaSummarySimulationsSURF - Week 5 - Summary

Quote:

This week I've been working on refining my simulation and getting it ready to be plugged into the control system. In particular, I've added a first attempt at a PDH control system, matrix conversion from OSEMs to DOF and back, and all necessary DAC/ADC/AA/AI/whitening/dewhitening filters. Most of these work well, but the whitening filters have been giving me trouble. At one point, they were amplifying the signal instead of flatting it out, such that my simulation started outputting NaN (again).

This was wholeheartedly depressing, but switching out the whitening filters for flat ones seemed to make the problem go away, but brought another problem to light. The output to input ratio is minuscule (as in 10^-300/10^243, see Attachment 3 for the resulting bode plot between a force on the suspension pt in the x-direction and my two outputs - error signal and length signal, which is pretty much what you would expect it to be). I suspect that its related to the whitening filter problem (perhaps the dewhitening filter is flattening the signal instead of amplifying?). If that is the case, then switching the whitening/dewhitening filters ought to work. I'll try today and see what happens. The white/dewhite filters together result in a total gain of 1, which is a good fundamental test, but could mean absolutely nothing (i.e. they could both be wrong!). Judging from the fact that we want to flatten out low frequency signal when it goes through the whitening filter, the filters don't look switched (see Attachment 4 for a bode plot of white and dewhite).

The only other source of problems (given that the suspensions/local damping have been debugged extensively throughout this process - though they could bug out in conjunction with the cavity controls?) is the PDH system. However, separating each of the components showed that the error signal generated is not absurd (I haven't tested whether it makes sense or not, but at any rate it doesn't result in an output on the order of 10^-300).

In summary, I've made progress this week, but there is still far to go. Attachment 1 is my simulation from last week, Attachment 2 is my simulation from this week. A talk with Jamie about the "big picture" behind my project helped tremendously.

 Here's a screenshot of what's going on inside the cavity (Attachment 1). The PDH/mixer system outputs 0 for pretty much everything except really high numbers, which is the problem I'm trying to solve now. I assumed that the sidebands were anti-resonant, calculated reflection coefficient F(dL) = Z * 4pi * i/(lambda), where Z = (-r_1 + r_2*(r_1^2 + t_1^2)/(1 - r_1*r_3)), then calculated P_ref = 2*P_s - 4sqrt(P_c*P_s) * Im(F(dL)) * sin(12.5 MHz * t) (this is pictured in Attachment 2), then mixed it with a sin(12.5MHz * t) and low-passed it to get rid of everything but the DC term (this is pictured in Attachment 3), which is the term that then gets whitened/anti-aliased/passed through the loop.

 

  7065   Wed Aug 1 10:45:38 2012 SashaSummarySimulationsSURF - Week 6 - Summary

This week, I worked on transferring my Simulink simulation to the RCG. I made all relevant library parts, now under "SASHA library" in the main Simulink library browser. My main concern has been noises - I've added some rudimentry shot noise, amplitude noise, phase noise, and intensity noise. I have yet to add local oscillator noise, and plan to upgrade the existing noises to actually have the PSD they should (using equations from Rana's and Robb Ward's theses). I'm fairly certain this can be achieved by applying the correct transfer function to white noise (a technique I learned from Masha this week!), so the RCG should be able to handle it (theoretically).

I've also been tweaking my main simulation. After a brief (but scary) attempt at adding optical levers, I decided to shelve it in order to focus on noises/RCG simulating. This is not permanent, and I plan to return to them at some point this week or next. My main problem with them was that I knew how to get from optical lever input to pitch/yaw, but had no idea how to get from pitch/yaw to optical lever input. If I had a complete basis for one in terms of the other, I'd be able to, but I don't think this is the way to go. I'm sure there is a good way to do it (it was done SOMEHOW in the original simulation of the suspensions), I just don't know it yet.

In the aftermath of the optical lever semi-disaster, my simulation is once again not really outputting anything, but since it actually worked before adding the optical levers, I'm pretty sure I can get it to work again (this is why its important to use either git or BACKUPS, >.< (or both)).

We also wrote our progress reports this week. Mine includes some discussion on the basics of cavities/the mechanics of the suspensions/brief intro to PDH, and I'll add a section on noises in the next draft. Maybe this'll be of some use to someone someday? One can only hope.

 

 

  7116   Wed Aug 8 11:16:06 2012 SashaSummarySimulationsSURF - Week 7 - Summary

This week, I brought my c1lsp model online and fixed up some the medm screens for c1spx. Along the way, I ran into a few interesting problems (and learned a bit about bash scripting and emacs! :D). The screens for the main TM_RESP matrix are not generating automatically, and the medm screens don't want to link to the channels, for some reason. I don't have this problem with the other matrices (i.e. C2DOF and SEN_OUT), so I think it has something to do with TM_RESP being a filter matrix (which the others are not). In addition, the noise overview medm screens for c1spx are practically nonexistent - someone just copied the file for the SUS-ETMX screens into the master directory for c1spx, so they need a complete overhaul. I am willing to do this, but Jamie told me to focus my attentions elsewhere.

So I went back to noise generation. I've been using Matlab to figure out how to recreate the various noise sources (laser amplitude noise, local oscillator phase/amplitude noise, and 60 Hz/ADC. Frequency noise will be added some time this week and seismic noise should be already covered in Jamie's suspension model) in my c1lsp model. I'm doing it the way the RCG does it - by applying a filter to white noise. I'm generating white noise by just using a random number generator and pwelch-ing it to get the power spectral density.

For the filters themselves, I picked z, p, k such that it shaped the white noise PSD to look like the PSD of the noise in question. This was fairly straightforward once I figured out how zeroes and poles affected PSD. Once I'd picked zpk, I applied a bilinear transform to get a discrete zpk out, then converted to a second order section to make computation faster. I then applied that to the white noise (matlab has a convenient "sosfilt" function) and pwelch-ed/graphed it to get the result.

Attached is my attempt at filtering white noise to look like 60 Hz. noise. I can't seem to find a way to pick z and p such that the peak is more narrow (i.e. other than having two complex conjugated poles at 60 Hz.). I took the spectrum of 60 Hz. noise from a terminated ADC channel (Masha kindly let me borrow one of her GURALP channels).

EDIT: I also remembered that I've been looking for how to get a good power spectrum for the rest of the noises. Jenne referred me to Kiwamu's work on this, and I'm mostly going off elog #6133. If you have any other good elogs/data on noises, please feel free to send them my way.

I then measured the PSD of the sensors on the real suspended optics and a PSD of the suspension model. It looks like the OSEMs on the suspension model are only reading white noise, which probably means a lost connection somewhere (Attachment 2 is what the model SHOULD produce, Attachment 3 is what the model ACTUALLY produces). I perused Jamie's model, but couldn't find anything. Not sure where else to check, but I'll continue thinking about it/trying to fix it.

  12118   Tue May 17 05:50:43 2016 Varun KelkarUpdateGeneralSURF 2016

Hello, I am Varun Kelkar. I will be working at the 40m lab as a SURF student this summer with Eric Quintero on Audio processing for real time control system signals. This week I will mostly be working on implementing basic DSP C-code offline. Currently I am trying to write a code for noise whitening.

-Varun

  12121   Wed May 18 17:42:52 2016 VarunUpdateGeneralSURF 2016

Finished writing the code on whitening. I have to still test it. uploaded on github noise cancellation repo. @eric could you give me some data of noise power spectral density for testing the code?

-Varun

Quote:

Hello, I am Varun Kelkar. I will be working at the 40m lab as a SURF student this summer with Eric Quintero on Audio processing for real time control system signals. This week I will mostly be working on implementing basic DSP C-code offline. Currently I am trying to write a code for noise whitening.

-Varun

 

  12123   Fri May 20 00:06:19 2016 VarunUpdateGeneralSURF 2016

I have written a basic version of AGC, and have done some tests with a data file. will do tests on whitening and agc today. Also, today I have to go to the SSN office. Hence will be late.

 

-Varun

Quote:

Finished writing the code on whitening. I have to still test it. uploaded on github noise cancellation repo. @eric could you give me some data of noise power spectral density for testing the code?

-Varun

Quote:

Hello, I am Varun Kelkar. I will be working at the 40m lab as a SURF student this summer with Eric Quintero on Audio processing for real time control system signals. This week I will mostly be working on implementing basic DSP C-code offline. Currently I am trying to write a code for noise whitening.

-Varun

 

 

  12127   Mon May 23 17:47:51 2016 VarunUpdateGeneralSURF 2016

Tested the AGC today with LSC cavity transmission signal and error signal. Not in real time still.

Key to attachments:

cav_tr-eps-converted-to.pdf: LSC cavity transmission signal input

cav_tr_out-eps-converted-to.pdf: LSC cavity transmission signal, output of the AGC.

  12136   Wed May 25 14:29:31 2016 VarunUpdateGeneralSURF 2016

Edited the AGC to include overlapping frames yesterday. forgot to put an elog on it!

Quote:

Tested the AGC today with LSC cavity transmission signal and error signal. Not in real time still.

Key to attachments:

cav_tr-eps-converted-to.pdf: LSC cavity transmission signal input

cav_tr_out-eps-converted-to.pdf: LSC cavity transmission signal, output of the AGC.

 

  12137   Thu May 26 18:10:48 2016 VarunUpdateGeneralSURF 2016

Wrote and tested a function for downconversion. It contains a mixer with a sinusoidal input for modulation with the desired frequency and a 2nd order butterworth low pass filter to remove the higher frequency-shifted part of the modulated signal. I have tested this with input of 2kHz giving a good output of 200 Hz on the speaker. Codes are uploaded on github, will update the real time document tomorrow.

 

-Varun

Quote:

Edited the AGC to include overlapping frames yesterday. forgot to put an elog on it!

Quote:

Tested the AGC today with LSC cavity transmission signal and error signal. Not in real time still.

Key to attachments:

cav_tr-eps-converted-to.pdf: LSC cavity transmission signal input

cav_tr_out-eps-converted-to.pdf: LSC cavity transmission signal, output of the AGC.

 

 

  12153   Tue Jun 7 17:21:13 2016 AakashUpdateGeneralSURF 2016

Hi!

I am Aakash Patil. I will be working at the 40m lab as a SURF student with Gautam Venugopalan on enclosures for seismometers to shield them from thermal and magnetic fluctuations. This week I will be working on the development of hardware for four probe measurement along with a constant current source. It will effectively help us in accurate temperature measurement throughout the development of enclosure.

 

  12134   Wed May 25 11:51:40 2016 SteveUpdatesafetySURF 2016 safety
Quote:

Hello, I am Varun Kelkar. I will be working at the 40m lab as a SURF student this summer with Eric Quintero on Audio processing for real time control system signals. This week I will mostly be working on implementing basic DSP C-code offline. Currently I am trying to write a code for noise whitening.

-Varun

Varun has received 40m specific basic safety training today.

  12157   Wed Jun 8 10:20:14 2016 SteveUpdatesafetySURF 2016 safety

Aakash Patil received 40m specific basic safety training.

Quote:
Quote:

Hello, I am Varun Kelkar. I will be working at the 40m lab as a SURF student this summer with Eric Quintero on Audio processing for real time control system signals. This week I will mostly be working on implementing basic DSP C-code offline. Currently I am trying to write a code for noise whitening.

-Varun

Varun has received 40m specific basic safety training today.

 

  12228   Wed Jun 29 15:34:00 2016 SteveUpdatesafetySURF 2016 safety

Praful Vasiceddy received 40m specific basic safety training.

Quote:

Aakash Patil received 40m specific basic safety training.

Quote:
Quote:

Hello, I am Varun Kelkar. I will be working at the 40m lab as a SURF student this summer with Eric Quintero on Audio processing for real time control system signals. This week I will mostly be working on implementing basic DSP C-code offline. Currently I am trying to write a code for noise whitening.

-Varun

Varun has received 40m specific basic safety training today.

 

 

  6962   Wed Jul 11 14:22:54 2012 EricSummaryGeneralSURF Update

Here's what I accomplished since my last elog:

I continued working on the beatbox calibration. Instead of using the function generator for an input signal,
I used the network analyzer because it can generate higher frequencies that are of more interest to us. I ran
the network analyzer output into the RF in port, and took voltage measurements from the Q port using the
oscilloscope. The frequency range I focused on was 100 - 200 MHz, and I also took more closely spaced measurements
from 180 - 200 MHz. The data is recorded on the computer now, and I will analyze it more fully in the future.

I also edited the Calibration page on the LIGO 40 m wiki. Rana showed me the page on calibration, but there was
limited information there, so he recommended that I post my work there as well. Right now I haven't posted much,
but I will likely add some information on the Simulink model I'm working on and results of measurements to be
taken as the project progresses.

The majority of my work has been on developing a Simulink model in Matlab of the differential arm length sensing
and control loop
. I am using Figure 6-1 from Rana's thesis as a guide on important components to include in the
model. Some of the details on the transfer functions of components need to be worked out, but a basic framework has
been established. Right now the transfer function of the arm cavity is being approximated as a single pole, but
we may integrate the calibration model I'm working on with Sasha's work on the arm cavity. I have also begun to
implement the length response function in the model
. I believe it is giving correct results at frequencies up to
100 Hz, but is off at higher frequencies. This might be fixed after I continue to fill in the transfer functions
of the digital components; they are currently set to 1 until I find more information on them.

  6990   Wed Jul 18 15:38:05 2012 EricSummarySimulationsSURF Update

Most of my work has been on continuing to develop the Simulink model of the differential arm length control loop.
I have filled in transfer functions for the digital components after looking up the configuration of filters and
gains on the control screens. Filters that were active at the time included 1:50 and 1000:10 on C1LSC_YARM and
C1LSC_POY11 with a gain of 0.1. Jamie also introduced me to foton so that I could obtain the transfer functions
for the necessary filters. I have also continued to work on obtaining the open loop gain and length response
function from the model. The majority of the work now is to refine what I've accomplished so far. Adding details
to the arm cavity and the optics is one potential area for improvement.

I have also spent some time looking at real-time calibration methods from GEO and a proposal for a similar system
on LIGO in P040057-x0 from the DCC. While the work for this project may follow a different path for a real-time
calibration, having a sense for what's been accomplished so far should be helpful in working on a new system.

  7025   Wed Jul 25 11:34:31 2012 EricSummarySimulationsSURF Update

I am continuing work on simulating the DARM control loop. There is now a block for the length response
function
that allows one to recover the h(t) GW input to the model. However, in order to add this
block I had to add some artificial poles to the length response function beacuse Simulink gave me errors
when the transfer function had more zeros than poles. The artificial poles are at 10^6 Hz and higher, so
that they should not affect the response function at the lower frequencies of interest. This approach
appears a bit computationally unstable though because without changing any parameters and re-running
the simulation, a different magnitude for h(t) would be calculated sometimes. A different method may be
necessary to get this working more accurately
.

By looking through the C1LSC Simulink model and the C1LSC control screens, Jenne helped me determine
which digital filters are active while the interferometer is locked
. To do this, open the C1LSC control
screen, then open the trigger matrix. Inside the trigger matrix window there is a button titled Filter
Module Triggers which opens another window that indicates which filters are triggered for a given channel,
and what values trigger them. For the y arm servo filters FM2, 3, 6, 7, 8 are triggered while in lock and
FM4 and 5 are controlled manually; I am including all of these in the model now. 

I have changed the way I manipulate the output from the model for analysis, using Rana's advice. I also
improved the plotting code, now using a custom Bode plot instead.

Attached is a screenshot of the Simulink model as it currently stands, and an older implementation of the
open loop gain
. I am in the process of updating the servo filters now, and what is shown in the plot does
not include all the filter modules for the servo filter.

 

 

  7064   Wed Aug 1 10:38:11 2012 EricSummaryGeneralSURF Update

Since my last update I have modified the DARM control loop model to the extent that it resembles the
measured open loop transfer function much more closely
. The phase especially is much more accurate, with
a phase margin of about 35 degrees at the unity gain frequency of 156 Hz. Right now I'm normalizing to
the unity gain frequency still to adjust the gain properly. Using the length response function from the
model, I can calibrate the error signal as well to find the simulated h(t) output. There were a number of
computational problems in calculating the length response function, but I eventually found a work-around.
Attached is an updated plot of the open loop transfer function and the length response function of the model.

This week Jamie showed me around the real-time Simulink models as well. The one specific to my project
is c1cal.mdl
. It takes the output in the form of the error and control signals from c1lsc.mdl as its
input and produces the calibrated signal as output. In order to produce the calibrated signal we need the actuation
function and the inverse of the sensing function for the model as it stands now. We also built, installed,
and restarted the c1cal model because no data was showing up in data viewer, but the problem remained
after this attempt. 

Jamie and I also started on calibrating the interferometer in the traditional way. Jamie aligned the beam
splitter and the input test masses so we could take free-swinging Michelson measurements. However, taking
the data with the nds system appears to be giving different results than what is showing up in data viewer.
The goal of this measurement is to get a value for the peak to peak amplitude of the Michelson error signal.

  7119   Wed Aug 8 13:16:58 2012 EricSummaryGeneralSURF Update

This week I spent most of my time learning about how the interferometer is calibrated and working on the calibration itself. I also looked more into the Pound-Drever-Hall technique.

Continuing work on the free-swinging Michelson measurements, I changed the signal that I was using to C1:LSC-ASDC_OUT_DQ. This is a proper power signal so that the peak-to-peak amplitude of this error signal can be directly read off the graph. The motivation to measure this amplitude is that it must be known in order to calibrate the actuation of the input and end test masses.

Next I looked into using DTT to make some measurements. I ran the Michelson restore script in the IFO Configure screen to adjust the optics to be near alignment. Then I tweaked the precise settings in the IFO Align screen of pitch and yaw for the ITMX, ITMY, and BS. The goal with this was to minimize the magnitude of the C1:LSC-ASDC_OUT_DQ signal. After it was well-aligned, back in DTT I sent in a sine wave excitation and used a Triggered Time Response measurement to see the output. As a first test I put the excitation signal in the ASDC channel and I was able to plot the resulting OUT signal in DTT. The amplitude was different than I input due to gains between the excitation and the point of measurement, but this can easily be accounted for by adjusting the amplitude in DTT accordingly.

The next step is to work on measurements of a single arm cavity, introducing excitations there and measuring the response.

  7195   Wed Aug 15 16:29:59 2012 Eric SummaryGeneralSURF Update

This week I took more data for the calibration of YARM. The summary of measurements taken is:

1. Peak-to-peak on Michelson
2. Michelson open loop
3. Excite ITMY and measure on AS55_Q_ERR
4. Excite ITMY and measure on POY11_I_ERR
5. Excite ETMY and measure on POY11_I_ERR
6. YARM open loop

Then I worked on comparing these measurements to the Simulink model of the interferometer control loop. The measured open loop transfer function of the YARM matched well with the model above about 20 Hz, after the gain was scaled properly to fit the data. Next is to fit the length response function of the model and the measurements, and then use DTT to calibrate the arm cavity's power spectrum.

  6881   Wed Jun 27 14:12:44 2012 EricSummaryGeneralSURF Week 1

I started work familiarizing myself with the ELOG and some of the control systems at the 40m. I spent a fair bit of time gaining some general knowledge of the interferometer, control systems, calibration, null instruments, etc. On Friday, June 22 Yaakov and I spent the afternoon pulling cables for the beatbox that Jamie had finished up. We were able to get the cables from the rack containing the beatbox routed to the control room.

Then I started work on calibrating the beatbox. I set up the function generator to send a sine wave into the beatbox, then sent the signal from the beatbox to the oscilloscope. I compared both the input sine wave and the output from the beatbox at many frequencies, taking peak to peak measurements. I'm working on using the data to calibrate the beatbox now.

  1697   Wed Jun 24 12:04:22 2009 ZachUpdateCamerasSURF entry

This week, I've been reading some literature concerning PLL and familiarizing myself with LINUX, MATLAB, and high-pass filter circuits.  In MATLAB, I started constructing matrices to be used for a beam path analysis from the laser output to the ccd camera.  I also built a simple high-pass filter on a bread-board that Joe and I are currently testing with the spectrum analyzer.

  3150   Wed Jun 30 18:16:55 2010 steveUpdateSAFETYSURF safety training 2010

40m SURFs Razib Obaid, Nancy Aggarwal, Unknown Bearded SMURF, Megan Daily, Gopal Nataraj, Katharine Larson and Sharmila Dhevi received 40m specific safety training on June 23, 2010.

ELOG V3.1.3-