  14531   Wed Apr 10 22:59:22 2019 gautamUpdateIOOSpooled fiberSteve had showed me some stock of long
fibers a while back - they are from Oz Optics,
and are 50m long, and are already spooled
  
  14532   Wed Apr 10 23:37:59 2019 gautamUpdatePSLPSL fan is noisyAttached is my phone recording of what
it sounds like right now in the PSL enclosure
- not good for frequency noise measurement!
 New_Recording.m4a 
  14533   Thu Apr 11 01:10:05 2019 gautamUpdateALSLarge 2kHz peak (and harmonics) in ALS XThese weren't present last week. The
peaks are present in the EX PDH error monitor
signal, and so are presumably connected with
 EX_PDH_2kNoise.pdf 
  14541   Mon Apr 15 10:20:44 2019 gautamUpdateOptical LeversBS Oplev PIT was oscillatingThe AS spot on the camera was oscillating
at ~3 Hz. Looking at the Oplevs, the culprit
was the BS PIT DoF. Started about 12 hours
 BS_OL_oscillating.png 
  14544   Mon Apr 15 22:39:10 2019 gautamUpdateFrequency noise measurementAlternate setup with PSL pickoff[anjali, gautam]

just main points, anajli is going
to fill out the details.
  
  14545   Mon Apr 15 22:55:34 2019 gautamFrogsThermal CompensationLab thermostat adjustedIt is feeling cold in the office area.
According to the digital wall clock near
the coffee machine, it is 19C. Rana bumped
  
  14546   Tue Apr 16 22:06:51 2019 gautamUpdateVACVac interlock tripped againThis happened again, about 30,000 seconds
(~2:06pm local time according to the logfile)
ago. The cited error was the same -
 Screenshot_from_2019-04-16_22-05-47.pngScreenshot_from_2019-04-16_22-06-02.png 
  14547   Wed Apr 17 00:43:38 2019 gautamUpdateFrequency noise measurementMZ interferometer ---> DAQ
Delay fiber was replaced with 5m
(~30 nsec delay)

The fringing
of the MZ was way too large even with the
  
  14548   Wed Apr 17 00:50:17 2019 gautamUpdateALSLarge 2kHz peak (and harmonics) in ALS X no moreI looked into this issue today. Initially,
my thinking was that I'd somehow caused
clipping in the beampath somewhere which
 EX_PDHnoise.pdf 
  14549   Wed Apr 17 11:01:49 2019 gautamUpdateALSLarge 2kHz peak (and harmonics) in ALS X no moreEX green stayed locked to XARM length overnight
without a problem. The spectrogram doesn't
show any alarming time varying features around
 EX_PDH_specGram.pdf 
  14550   Wed Apr 17 18:12:06 2019 gautamUpdateVACVac interlock tripped againAfter getting the go ahead from Chub and
Jon, I restored the Vacuum state to "Vacuum
normal", see Attachment #1. Steps:
 Screenshot_from_2019-04-17_18-11-45.pngScreenshot_from_2019-04-17_18-21-30.png 
  14551   Thu Apr 18 22:35:23 2019 gautamUpdateSUSETMY actuator diagnosis [rana, gautam]

Rana did a checkout of my story
  
  14552   Thu Apr 18 23:10:12 2019 gautamUpdateLoss MeasurementX arm misalignedYehonathan wanted to take some measurements
for loss determination. I misaligned the
X arm completely and we installed a PD on
  
  14554   Fri Apr 19 11:36:23 2019 gautamUpdateSUSNo consistent solution for output matrixTher isn't a consistent set of OSEM
coil gains that explains the best actuation
vectors we determined yesterday. Here are
  
  14556   Fri Apr 19 14:06:36 2019 gautamUpdatePSLInnolight NPRO shutoffWhen I got back from lunch just now, I
noticed that the PMC TRANS and REFL cameras
were showing no spots. I
 Screenshot_from_2019-04-19_14-06-11.png 
  14558   Fri Apr 19 16:19:42 2019 gautamUpdateSUSActuation matrix still not orthogonalI repeated the exercise from yesterday,
this time driving the butterfly mode [+1
-1 -1 +1] and adding the tuned PIT and
  
  14560   Fri Apr 19 20:21:52 2019 gautamUpdatePSLInnolight NPRO shutoffHappened again at ~730pm.

The NPRO diag channels don't
really tell me what happened in a causal
 Screenshot_from_2019-04-19_20-27-04.png 
  14562   Mon Apr 22 22:43:15 2019 gautamUpdateSUSETMY sensor diagnosis Here are the results from this test. The
data for 17 April is with the DC bias for
ETMY set to the nominal values (which gives
 ETMY_sensorSpectra_consolidated.pdf 
  14566   Wed Apr 24 16:06:44 2019 gautamUpdatePSLInnolight NPRO shutoffAfter discussing with Koji, I turned the
NPRO back on again, at ~4PM local time. I
first dialled the injection current down
 PMCrefl.png 
  14567   Wed Apr 24 17:07:39 2019 gautamUpdateSUSc1susaux in-situ testing [and future of IFOtest][jon, gautam]

For the in-situ test, I decided
that we will use the physical SRM to test
 2019-04-24_20-29.pdfScreenshot_from_2019-04-24_20-05-54.pngSRM_OSEMPD_WHT_ACROMAG.pdfDCVmon.png 
  14569   Thu Apr 25 00:30:45 2019 gautamUpdateSUSETMY BR mode We briefly talked about the bounce and
roll modes of the SOS optic at the meeting
today. 
 ETMY_sensorSpectra_BRmode.pdfETMY_sensorSpectra_BRmode.pdfETMX_sensorSpectra_BRmode.pdfIMG_5993.JPG 
  14570   Thu Apr 25 01:03:29 2019 gautamUpdatePSLMC trans is ~1000 cts (~7%) lower than usualWhen dialing up the current, I went up
to 2.01 A on the front panel display, which
is what I remember it being. The label on
  
  14573   Thu Apr 25 10:25:19 2019 gautamUpdateFrequency noise measurementHomodyne v HeterodyneIf I understand correctly, the Mach-Zehnder
readout port power is only a function of
the differential phase accumulated between
  
  14575   Thu Apr 25 11:27:11 2019 gautamUpdateVACPSL shutter re-openedThis activity seems to have closed the
PSL shutter (actually I'm not sure why
that happened - the interlock should only
  
  14577   Thu Apr 25 17:31:56 2019 gautamUpdatePSLInnolight NPRO shutoffNPRO shutoff at ~1517  local time
today afternoon. Again, not many clues from
the NPRO diagnostics channel, but to my eye,
 EdwinShutoff20190425.pngEdwinShutdown_zoomOut.png 
  14582   Sun Apr 28 16:00:17 2019 gautamUpdateComputer Scripts / ProgramsList of suspension testHere are some tests we should script.


Checking Coil Vmons, OSEM
PDmons, and watchdog enable wiring

Disable
  
  14583   Mon Apr 29 16:25:22 2019 gautamUpdatePSLPSL turned on againI turned the 2W NPRO back on again at ~4pm
local time, dialing the injection current
up from 0-2A in ~2 mins. I noticed today
  
  14584   Mon Apr 29 16:34:27 2019 gautamUpdateElectronicsITMX/IMTY mis-labelling fixed at 1X4 and 1X5After the X and Y arm naming conventions
were changed, the labelling of the electronics
in the eurocrates was not changed 😞
 IMG_7400.JPGIMG_7401.JPG 
  14587   Thu May 2 10:41:50 2019 gautamUpdateSUSSOS Magnet polarityA concern was raised about the two ETMs
and ITMX having the opposite response (relative
to the other 7 SOS optics) in the OSEM PDmon
  
  14591   Fri May 3 09:12:31 2019 gautamUpdateSUSAll vertex SUS watchdogs were trippedI found the 8 vertex watchdogs tripped
today morning. The ETMs were fine, suggesting
this was not an actual earthquake. I suspect
 SUSwatchdogs.png 
  14592   Fri May 3 12:48:40 2019 gautamUpdateSUS1X4/1X5 cable adminChub and I crossed off some of these items
today morning. The last bullet was addressed
by Jon yesterday. I added a couple of
 D38CC485-1EB6-4B34-9EB1-2CB1E809A21A.jpeg 
  14593   Fri May 3 12:51:58 2019 gautamUpdatePSLPSL turned on againPer instructions from Coherent, I made
the some changes to the NPRO settings. The
value we were operating at is in the column
  
  14594   Fri May 3 15:40:33 2019 gautamUpdateGeneralCVI 2" beamsplitters deliveredFour new 2" CVI 50/50 beamsplitters
(2 for p-pol and 2 for s-pol) were delivered.
They have been stored in the optics cabinet,
  
  14595   Mon May 6 10:51:43 2019 gautamUpdatePSLPSL turned off againAs we have seen in the last few weeks,
the laser turned itself off after a few hours
of running. So bypassing the lab interlock
 NPROshutoff.png 
  14599   Thu May 9 19:50:04 2019 gautamUpdatePSLPSL turned off againThis time, it stayed on for ~24 hours.
I am not going to turn it on again today
as the crane inspection is tomorrow and we
 Screenshot_from_2019-05-09_19-49-29.png 
  14602   Fri May 10 15:18:04 2019 gautamUpdatePSLSome work on/around PSL table
In anticipation of installing the
new fan on the PSL, I disconencted the old
fan and finally removed
 IMG_7427.JPGIMG_7428.JPGIMG_7429.JPGnewPSLAcro.png 
  14603   Fri May 10 18:24:29 2019 gautamUpdateNoiseBudgetaligoNBI pulled the aligoNB git repo to /ligo/GIT/aligoNB/aligoNB.   
  14605   Mon May 13 10:45:38 2019 gautamUpdatePSLPSL turned ON againI used some double-sided tape to attach
a San
Ace 60 9S0612H4011 to the Innolight controller
 IMG_7431.JPG 
  14606   Mon May 13 18:48:32 2019 gautamUpdateGeneralVent prep
c1auxey and c1aux VME crates were
keyed.
EX and EY NPROs were turned
on.
Y arm was aligned to the IR
 ventPrep_20190514.pngdriftMon_20190514.pnglowPowIMC.pngIMG_7434.JPG 
  14607   Tue May 14 10:35:58 2019 gautamUpdateGeneralVent underway
PSL had stayed on overnight. There
was an EQ (M 4.6 near Costa Rica) which showed
up on the Seis BLRMS, and I noticed that
 vent.pngScreenshot_from_2019-05-14_16-35-16.png 
  14608   Wed May 15 00:40:19 2019 gautamUpdateSUSETMY diagnosis planI collected some free-swinging data from
earlier today evening. There are still only
3 peaks visible in the ASDs, see Attachment
 ETMY_sensorSpectra.pdf 
  14609   Wed May 15 10:56:47 2019 gautamUpdatePSLPSL turned ON againTo test the hypothesis that the fan replacement
had any effect on the NPRO shutoff phenomena,
I turned the HEPA on the PSL table down to
  
  14610   Wed May 15 10:57:57 2019 gautamUpdateSUSEY chamber opened[chub, gautam]


Vented the EE annulus.
Took
the heavy door off, put it on the wooden
  
  14611   Wed May 15 17:46:24 2019 gautamUpdateSUSETMY inspectionI setup the usual mini-cleanroom setup
around the ETMY chamber. Then I carried out
the investigative plan outlined here.
 firstContactFiber.JPGETMY_sensorSpectra.pdf 
  14613   Thu May 16 13:07:14 2019 gautamUpdateSUSFirst contact residue removalI  used a pair of tweezers to remove
the stray fiber of first contact. As Koji
predicted, this was rather dry and so it
 etmy_sensors.pdfetmy_BRmode.pdf 
  14614   Thu May 16 22:58:25 2019 gautamUpdateASSIn air ASS test with green?We were wondering yesterday if we can somehow
test the ASS system in air. Though the arm
cavity can be locked with the low power IMC
  
  14615   Thu May 16 23:31:55 2019 gautamUpdateSUSETMY suspension characterizationHere is my analysis. I think there are
still some problems with this suspension.

 6x 
  14617   Fri May 17 10:57:01 2019 gautamUpdateSUSIY chamber openedAt ~930am, I vented the IY annulus by opening
VAEV. I checked the particle count, seemed
within the guidelines to allow door opening
  
  14618   Fri May 17 16:07:25 2019 gautamSummaryEquipment loanBorrowed componentZHL-3A (2 units) —-> QIL




  
  14620   Fri May 17 17:01:08 2019 gautamUpdateSUSETMY suspension characterizationTo investigate my mapping of the eigenfrequencies
to eigenmodes, I checked the Oplev spectra
for the last few hours, when the Oplev spot
 etmy_oplevs.pdf 