40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 218 of 344  Not logged in ELOG logo
IDup Date Author Type Category Subject Text Attachments
  10918   Sat Jan 17 15:07:28 2015 manasaUpdateGeneralBeat note frequency discrepancyI
was around the PSL table and the X end table
today.
  
  10919   Mon Jan 19 11:03:32 2015 manasaUpdateGeneralRF connections to adderRF connections to the beat note adder on
the IOO rack have been undone and it
should be good to proceed with any locking
  
  10920   Mon Jan 19 18:27:16 2015 ericqUpdateASCQPD ASC saga continues. Herein,
I will try
to paint a more thorough picture of this
 oplevPlant.pdfloopDesignComparison.pdfJan16_newLoops_offOn.png 
  10921   Tue Jan 20 02:39:49 2015 ericqUpdateASCQPD ASC saga continues. Although the QPD loops are less than
ideal right now, I made changes to the ASC
model to trigger the QPD loops on and off
  
  10922   Tue Jan 20 09:32:19 2015 SteveUpdatePEMdusty Monday morningYesterday morning was dusty. I wonder why?

The PRM sus damping was restored
this morning.
 dustyMorning.png 
  10923   Tue Jan 20 15:09:01 2015 JenneUpdateLSCLSC model change implemented 




  
  10924   Tue Jan 20 19:32:06 2015 JenneUpdateSUSSUS Drift restore scriptsI made little scripts to go with the sus
driftmon buttons, that will servo the alignment
sliders until the susyaw and suspit values
  
  10925   Tue Jan 20 20:03:17 2015 JenneUpdateLSCALS lock not staying?The Xarm ALS has been a little funky today. 

First, the green and the arm-axis
would not stay co-aligned.  I'm
  
  10926   Tue Jan 20 21:58:04 2015 diegoUpdateLSCSome locking, may need to modify UGF part again 




 UGF_SERVO_MDL.png 
  10927   Wed Jan 21 15:27:47 2015 JenneUpdateLSCFixed LSC model bugThis problem with the CARM loop last night
was the fault of a bug that I had put into
the LSC model last week.  When I gave
  
  10928   Thu Jan 22 02:56:07 2015 ericqUpdateIOOFSS input offset adjustedSince Rana's overhaul of the IMC, the
FSS input offset had been sitting at zero. 

Over the last day or so, I had
  
  10929   Thu Jan 22 03:21:24 2015 JenneUpdateLSCLocks with large MICH offsets[Jenne, Diego, EricQ]

Tonight we worked on the acquisition
sequence (including re-re-re-commissioning
 MICHoffset65percent.pnglockloss_21Jan2015_MICHhittingRails.png 
  10930   Thu Jan 22 15:35:41 2015 diegoUpdateSUSBounce/Roll MeasurementsI measured the bounce/roll frequencies
for all the optics, and updated the Mechanical
Resonances wiki page accordingly.
 BR_Jan2015.tar.bz2 
  10931   Thu Jan 22 18:36:11 2015 diegoUpdateIOOMC FlashesI've been looking into the data of
Jan 06 and Jan 15 taken during daytime, as
the night before we left the PRC aligned
 1104612646_zoom_1.pngelog.tar.bz2 
  10932   Thu Jan 22 22:15:30 2015 diegoUpdateSUSCentered OpLevs[Diego, Jenne]

We centered the OpLevs for ITMX
and ITMY.
  
  10933   Fri Jan 23 02:11:40 2015 JenneUpdateLSCCARM filters modified slightly[Jenne, Diego]

One of tonight's goals was
to tweak the CARM filters, so that we could
 plot.pngCARM_22Jan2015.pdf 
  10934   Fri Jan 23 10:07:15 2015 SteveUpdateSUSSUS Drift ETMX vs ETMYETMX YAW stopped drifting Jan 8, 2015




 SUSdrift30d.png 
  10935   Fri Jan 23 14:25:03 2015 evanUpdateCDSNew netgpib scripts for SR785Does netgpibdata/TFSR785
work at the 40m currently? I rsynced the
netgpibdata
 TFSR785.zip 
  10936   Fri Jan 23 15:46:21 2015 ericqUpdateCDSNew netgpib scripts for SR785


  
  10937   Fri Jan 23 18:08:10 2015 JenneUpdateCDSEPICS freezesSo, I neglected to elog this yesterday,
but yesterday we had one of those EPICS freezes
that only affects slow channels that come
  
  10938   Fri Jan 23 19:38:02 2015 JenneUpdateLSCcarm_cm_up supports both signs of CARM offsetA small change, but now the carm_up script
supports both sides of the CARM offset. 
After the arms are locked with ALS it asks
  
  10939   Mon Jan 26 13:07:28 2015 JenneUpdatePEMSeismometers back in nominal placesI have just put the seismometers back into
their nominal positions, on the concreted
slabs.  The T-240 is in the vertex,
 IMG_1800.JPGIMG_1805.JPG 
  10940   Mon Jan 26 17:43:52 2015 ericqConfigurationIOOMC Autolocker updateThe MC autolocker hasn't been
so snappy recently, and has been especially fussy
today. Previously, the mcup script was triggered
  
  10941   Mon Jan 26 21:10:04 2015 JenneUpdateModern ControlWaking up the OAFI had a look at the OAF model today. 

Somehow, the screens that we had
weren't matching up with the model. 
  
  10942   Tue Jan 27 04:11:21 2015 JenneUpdateLSCSmall tweaks to the locking[Jenne, Diego, EricQ]

We did a series of small things
that may have helped with the locking, although
 CARM_27Jan2015_JCD.pdfDARM_27Jan2015.pdf 
  10943   Tue Jan 27 14:00:05 2015 JenneUpdateModern ControlPRMI lockedPRMI is locked on sideband, starting ~4
minutes ago, to collect ASC/seismic data
for feedforward.
  
  10944   Tue Jan 27 15:45:26 2015 diegoUpdateLSCSmall tweaks to the lockingThe UGF Servo medm page has been updated
to reflect the last changes, namely the return
of the sum of squares and the disappearance
  
  10945   Tue Jan 27 17:58:21 2015 JenneConfigurationTreasureWelcome, Donatella!Welcome to your new abode, Donatella!  IMG_1806.JPG 
  10946   Tue Jan 27 21:33:39 2015 KojiUpdateASCASS retunedI checked the situation of ASS. I wanted
to know how much we are away from the maximum
transmittion.
  
  10947   Wed Jan 28 03:01:24 2015 JenneUpdateLSCTransitioned DARM to AS55Q[Jenne, Diego]

Tonight
we were able to transition DARM from DC transmission
  
  10948   Wed Jan 28 08:53:01 2015 SteveUpdatePEMSeismometer Vertex is covered 




  
  10949   Wed Jan 28 14:19:02 2015 ranaUpdateLSCTransitioned DARM to AS55QWhy AS55/(TRX + TRY) instead of just TRX?
Isn't (TRX+TRY) controlled by CARM?
  
  10950   Wed Jan 28 17:32:26 2015 KojiUpdatePSLPMC alignedPMC aligned.

PMC Trans increased from 0.740
to 0.782
  
  10951   Wed Jan 28 17:39:17 2015 KojiConfigurationIOOX Trans Table less crazy but not enough yetThe X-end IR Trans path was cleaned
up.

I have been investigating the Xarm
 IMG_1808.JPG 
  10952   Wed Jan 28 23:53:24 2015 KojiSummaryASCXarm ASS fixX-Arm
ASS was fixed.
ASS_DITHER_ON.snap was updated so
 12.png 
  10953   Thu Jan 29 04:27:35 2015 ericqUpdateLSCCARM on REFL11[ericq, Diego]

Tonight,
 Jan29_REFL11_lockloss.png 
  10954   Thu Jan 29 09:50:47 2015 manasaUpdateElectronicsIOO rack amplifier panelThe RF amplifier panel on the IOO rack
(Attachment 1) will be used to also hold
the RF amplfiers for the frequency counters.
 panel_front.jpgpanel_back.jpg 
  10955   Thu Jan 29 10:14:21 2015 manasaUpdateGeneralX end space issuesIt is certain that we have space issues
at the X end that has been preventing us
from sticking in a lens to couple light into
 photo.pngdrawing.png 
  10956   Thu Jan 29 11:59:48 2015 manasaUpdateGeneralBeat note frequency discrepancyBelow is the set of plots comparing measurements
for the green and IR beat notes frequencies.
The measurements were made on the spectrum
 Freq_compare1.pngFreq_compare2.png 
  10957   Thu Jan 29 16:14:10 2015 manasaUpdateGeneralUpdated to do list for FOLSince there will be some work that supposedly
will involve moving stuff on the table and
racks; here is the updated to-do list for
 FOLtodolist1.png 
  10958   Thu Jan 29 17:20:58 2015 manasaConfigurationIOOX Trans Table less crazy but not enough yet[Koji, Manasa]

We cleared up some optics
and optomechanics at the X end table that
  
  10959   Fri Jan 30 02:57:03 2015 JenneUpdateModern ControlFirst try with PRCL ASC Wiener filtering[Aside - How do you rotate plots in the
new elog?  It's showing them correctly
in the attachments list below the entry,
 9x 
  10960   Fri Jan 30 03:12:15 2015 diegoUpdateLSCCARM on REFL11I[Jenne, Diego]

Tonight we continued following
the plan of last night: perform the transition
 PRCL_29Jan2015_Weird_Shape.pdfArmPowers20_MICHoffsetBeingReduced_0CARMoffset_29Jan2015.pdf 
  10961   Fri Jan 30 11:37:20 2015 manasaFrogsTreasureSP table madness endsSP table has been a mess because Q and
I had let our SURF leave without cleaning
up.
 before_after.jpgsort.jpg 
  10962   Sat Jan 31 01:34:12 2015 JenneUpdateLSCNot able to engage AO pathNothing earth-shattering today.

A few things of note:


I checked the coherence
 PRCL_CARM_Coupling_30Jan2015.pngPRCL_CARM_Coupling_lockloss_30Jan2015.png 
  10963   Mon Feb 2 12:24:27 2015 JenneUpdateASCPOP QPD centeredAfter aligning the PRC, I centered the
POP QPD.
  
  10964   Mon Feb 2 16:58:56 2015 manasaUpdateGeneralRF amplifier for ALSToday I was around the IOO rack.

I shutdown the power to the beat
PDs on the PSL table and disconnected the
 ALSXY_outLoop.png 
  10965   Mon Feb 2 22:59:49 2015 diegoUpdateLSCCM board input switched to AS55[Diego, Jenne]

We just changed the input to the
CM board from REFL11 to AS55.
  
  10966   Tue Feb 3 04:01:55 2015 diegoUpdateLSCCM servo & AO path status[Diego, Jenne]

Tonight we worked on the CM board
and AO path:
 CARM_03-02-2015_031754.pdf 
  10967   Tue Feb 3 04:07:49 2015 JenneUpdateModern ControlMeasured PRM -> POP QPD TFsToday (after centering the POP QPD), I
measured the PRM to POP QPD transfer functions. 
I am suspicious that this was part of my
 PIT_measured_TF.pngYAW_measured_TF.png 
ELOG V3.1.3-