40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 218 of 344  Not logged in ELOG logo
ID Date Author Type Categoryup Subject Text Attachments
  11064   Wed Feb 25 04:59:47 2015 JenneUpdateLSCDelay line re-installed, measurements round 2[Jenne, EricQ, Rana]

We spent this evening measuring
and thinking about our 3f signals, and the
 SensMat_PRMI_24Feb2015.pdf 
  11066   Wed Feb 25 12:16:27 2015 KojiUpdateLSCDelay line re-installed, measurements round 2WHAT?
WHAT? WHAT? It's obviously opposite.

If
the reflectivity of the front mirror is fixed
  
  11067   Wed Feb 25 14:18:28 2015 ranaUpdateLSCDelay line re-installed, measurements round 2The Schnupp asymmetry is definitely not
an important parameter (no need for Koji
to explode). It only serves to give us a
  
  11069   Wed Feb 25 14:51:13 2015 JenneUpdateLSCDelay line un-installed againAnd now I've removed the delay line,
and am in the process of reverting the demod
phases, etc.
  
  11070   Wed Feb 25 20:00:39 2015 JenneUpdateLSCDelay line un-installed again - sensing matrix comparisonsI have measured the sensing matrix for
the PRMI at the REFL photodiodes for both
the nominal configuration and the 33MHz cancellation
  
  11071   Wed Feb 25 23:48:57 2015 ranaUpdateLSCsome thoughts
Comparing just the 2 cases with
locking on 33, it seems that the 55 MHz gain
has changed by 14 dB instead of the 10 dB
  
  11072   Thu Feb 26 00:20:54 2015 ericqUpdateLSCModelled effect of relative modulation phaseI'm working on some more modelling
investigations of this whole situation. The
main thing I wanted to do was to look at
 33budget_canceled.png33budget_nominal.png2015-02-ModPhase.zip 
  11073   Thu Feb 26 01:51:39 2015 ericqUpdateLSCSideband HOMsSo, my previous post suggested that 44*11
products might be the dominating signals
in our "nominal" setup. I suppose
 C1_HOMcurves_PR.pngC1_HOMcurves_Y.pngC1_HOMcurves_X.pngC1_HOMlist.zip 
  11074   Thu Feb 26 01:53:35 2015 KojiUpdateLSCModelled effect of relative modulation phaseOk... This is what I was afraid of, and
it seems true.
i.e. the relation ship of the modulations
  
  11078   Thu Feb 26 16:37:21 2015 manasaFrogsLSCRIP illegal power supplyNo more illegal power supply at the LSC
rack 
  
  11080   Thu Feb 26 20:02:46 2015 JenneUpdateLSCre: some thoughtsI have clarified my elog from last night
to indicate that the sensing matrix in the
"33MHz cancellation" configuration
  
  11081   Fri Feb 27 01:59:57 2015 ranaHowToLSCiPython Notebook for LSC Sensing MatrixI
have adapted one of Evan's python scripts
 Plots_1109056456.pdfRadar_1109056456.pdf 
  11082   Fri Feb 27 03:48:29 2015 JenneUpdateLSCPRMI locked during CARM scanOne of the things that I looked at tonight
was whether or not I could hold the PRMI
on REFL165 at CARM offset of 0, and it turns
 REFL33Lock.pngREFL165Lock.png 
  11086   Fri Feb 27 21:16:10 2015 JenneUpdateLSCPRMI locked during CARM scanHere are a bunch of PDFs of time series
from last night's CARM sweeps. 
The y-axes are all calibrated (except for
 8x 
  11087   Mon Mar 2 17:02:01 2015 ericqUpdateLSCBS - PRM decouplingUsing PRX, I remeasured the relative actuation
strengths of the BS and PRM to see if the
PRM correction coefficient we're using
  
  11090   Tue Mar 3 04:41:45 2015 JenneUpdateLSCTransitioned DARM to AS55Q, some other workBetter elog tomorrow - notes for now:

REFL165 for PRMI has been "a
champ" (quote from Q).  We're
  
  11095   Tue Mar 3 19:19:54 2015 JenneUpdateLSCTransitioned DARM to AS55Q, some other work[Jenne, EricQ]

A slightly more coherent elog for
last night's work.
 ALSfool_PRFPMI_2Mar2015.pdfALSfool_kindaEngaged_2March2015_noFrames.png 
  11097   Wed Mar 4 03:42:14 2015 JenneUpdateLSCTried a few CARM / ALS fool things, no successMuch of tonight was spent fighting with
ETMX.  This time, ASC was definitely
off, there was nothing coming out of the
 PRFPMI_DARMonAS55Q_3Mar2015.pdf 
  11098   Wed Mar 4 19:03:19 2015 ericqUpdateLSCArm length remeasurementAs discussed at today's meeting, we
would like to (re)measure the Arm cavity
lengths to ~mm precision, and their g-factors.
 Xscan.pngYscan.png 
  11099   Thu Mar 5 04:29:13 2015 ericqUpdateLSCLocking work tonightBrief elog of my activities tonight:

I was able to transition the digitial
CARM control to REFL11 through the common
  
  11105   Thu Mar 5 21:42:05 2015 JenneUpdateLSCAS55Q flat at DARM zero crossingI think we've seen this in simulations,
but it's a little disheartening to see
in real life.  AS55Q looks like it flattens
 DARM_TimeSeries_5March2015.pdf 
  11107   Fri Mar 6 02:10:35 2015 ranaUpdateLSCArm length remeasurementThis has been done before:

http://nodus.ligo.caltech.edu:8080/40m/6938

Arm length measurements and g-factor
  
  11108   Fri Mar 6 04:49:08 2015 JenneUpdateLSCAS55Q transition[Jenne, Ranah]

We played around tonight with different
possible ways of transitioning DARM to normalized
 DARM_AS55Qnormalized_5March2015.png 
  11113   Sat Mar 7 18:53:48 2015 JenneUpdateLSCDoF selector matrices replaced with filter banksThis is work that I did yesterday but didn't
have time to elog.  Since it seems non-trivial
to give ourselves ramping matrices, but we
 DoFselectors_7March2015.png 
  11114   Sat Mar 7 19:15:17 2015 JenneUpdateLSCModified zero crossing triggeringMore work from yesterday. 

Rana and I had discussed on Thursday
night that we probably want to be able to
 LatchLogic_6March2015.png 
  11115   Sat Mar 7 19:23:27 2015 JenneUpdateLSCUpdated ALSwatch scriptLast report on model change / screen work
from yesterday.

The ALSwatch script has always
  
  11116   Sat Mar 7 22:01:12 2015 JenneConfigurationLSCCARM and DARM on RF signals!!!!!!!!!!!!!!!!!!!![Jenne, with Matt and Fujimi as witnesses]

It
might be about time to throw that champagne
 ARM_POWERS_100.png 
  11117   Sun Mar 8 00:05:37 2015 KojiConfigurationLSCCARM and DARM on RF signals!!!!!!!!!!!!!!!!!!!!Exciting! How long was it?   
  11118   Sun Mar 8 01:27:01 2015 JenneConfigurationLSCCARM and DARM on RF signals!!!!!!!!!!!!!!!!!!!!I have in my notebook that at 9:49pm CARM
was no longer using ALS as an error signal,
and at 9:50pm, DARM was no longer using ALS
 RFlock3min.png 
  11119   Sun Mar 8 03:27:48 2015 JenneUpdateLSCError signal blending for CARM/DARM transitionsThis elog will be about work that happened
yesterday.  I will write a reply to
this with work from this evening's success.
  
  11120   Sun Mar 8 04:04:19 2015 JenneUpdateLSCError signal blending for CARM/DARM transitionsAs I (very excitedly) reported in elog
11116, I was able to follow the error
signal blending procedure from last night,
  
  11121   Sun Mar 8 13:51:41 2015 ranaUpdateLSCError signal blending for CARM/DARM transitionsAccording
to the official rules, we only need 8 seconds
  
  11122   Mon Mar 9 14:14:32 2015 JenneUpdateLSCError signal blending for CARM/DARM transitionsHere is a longer stretch of data, from
the first RF-only lock on Saturday night.
 Unfortunately daqd had died about 400
 First-ever_RFonly_lock_7March2015.pngSecond-ever_RFonly_lock_7March2015.png 
  11126   Tue Mar 10 03:37:03 2015 ericqUpdateLSCLocking efforts[Q,
J]

Not
 2015-03-10_rfCarmOLG.png2015-03-10_rfTransitions.png 
  11133   Wed Mar 11 18:02:02 2015 JenneUpdateLSCCARM and DARM loops marginalI have looked at the CARM and DARM RF loops,
assuming the loop shapes that we've been
using, and it pretty much looks like a miracle
 CARMloop_ALSvsREFL_fcav150_fcomp150.pngCARMloop_ALSvsREFL_fcav150_fcomp80.pngDARMloop_ALSvsAS55_fcav4500_nocomp.png 
  11134   Wed Mar 11 19:15:03 2015 KojiSummaryLSCROUGH calibration of the darm spectrum during the full PRFPMI lockI made very rough calibration of
the DARM spectra before and after the transition
for the second lock on Mar 8.
 150308_DARM_ROUGH_CALIB.pdf 
  11136   Thu Mar 12 03:47:56 2015 JenneUpdateLSCCARM and DARM loop adjustmentsNo wins tonight.

I've tried playing with the
shapes of the loops a little bit (mostly
  
  11138   Thu Mar 12 19:54:31 2015 Q UpdateLSCHow to: PRYQ doesn't like elogging, but he sent
me this nice detailed email, so I'm copying
it into the log:
  
  11139   Fri Mar 13 03:10:35 2015 JenneUpdateLSC6+ CARM->REFL transitions, 1 DARM->AS transitionMuch more success tonight. 
I only started my tally after I got the CARM
 AS55whitening_lockloss_12March2015.pdfMoreDARMB_powerWentDown_12March2015.pngcarm_cm_up_zip.sh.gz 
  11140   Fri Mar 13 14:11:59 2015 ranaUpdateLSC6+ CARM->REFL transitions, 1 DARM->AS transitionSince the DARM_OUT signal is only 500 counts_peak,
I don't see why AS55 whitening needs
to be switched on.
  
  11143   Sat Mar 14 01:14:09 2015 JenneUpdateLSCMore stable DARM transitions[Jenne, Koji, Rana]

Thanks to turning off the AS55
analog whitening as well as the 1k:6k lead
 DARM_RF-only_13Mar2015.pdf 
  11144   Sun Mar 15 18:49:57 2015 JenneUpdateLSCMore stable DARM transitionsI have modified the DARM model from elog
11133, to include the fact that these
 DARM_modelVsmeas_15March2015.pngDARMresiduals.png 
  11154   Sat Mar 21 05:19:49 2015 JenneUpdateLSCIFO awake[Jenne, Den]

The problem with the ASS
turned out to be a mode that was rung up
 carm_cm_up_zip.sh.gz 
  11163   Tue Mar 24 05:05:09 2015 ericqUpdateLSCAO Path engaged[J, Q]

Terse tonight, more verbose tomorrow. 

We have succesfully achieved multiple
 CARM_DARM_AOengaged_23March2015.pdfloops.png 
  11167   Tue Mar 24 18:22:11 2015 ericqUpdateLSCAO Path engagedFor increased flatness of the AO response,
and thus less gain peaking in the CARM loop,
I reccomend turning down the MC servo VCO
 IMC_ao_Mar242015.pngIMC_olgs_Mar242015.png 
  11168   Tue Mar 24 18:47:10 2015 ericqUpdateLSCAO Path engagedJenne has more detailed notes about how
things went down last night, but I figure
I should write about how we got the
  
  11169   Wed Mar 25 03:31:18 2015 JenneUpdateLSCMeh[Jenne, Den]

Overall a "meh" night
for locking I think.  The script to
  
  11170   Wed Mar 25 08:29:31 2015 SteveUpdateLSCMeh  I turned on the HEPA at the south
end during the LSC. Sorry I ment to turn
it off.
  
  11172   Wed Mar 25 18:46:14 2015 JenneUpdateLSCREFL PDs get more lightAfter discussions during the meeting today,
I removed the PBS from the REFL path, which
gives much more light to REFL11, REFL33 and
 AS_REFL_branchingRatios_25Mar2015.png 
  11173   Wed Mar 25 18:48:11 2015 KojiSummaryLSC55MHz demodulators inspection[Koji Den EricG]

We inspected the {REFL, AS, POP}55
demodulators.
  
ELOG V3.1.3-