  9364   Mon Nov 11 12:19:36 2013 ranaUpdateCDSFE Web view was fixed

    

       
            
  
  9365   Mon Nov 11 22:35:45 2013 RANAUpdateIOOPSL pointing monitoringSince the pointing has gone bad again,
I went to the PSL to investigate. Found some
bad things and removed them:
 qpd.pdf 
  9366   Tue Nov 12 15:04:35 2013 ranaUpdateCDSFE Web view was fixed

    

       
            
  
  9367   Tue Nov 12 16:49:22 2013 JenneUpdateLSCXend QPD and Whitening board pulled

    

       
            
 IMG_1262.JPGIMG_1260.JPGIMG_1264.JPGIMG_1276.JPG 
  9368   Tue Nov 12 21:50:01 2013 ranaUpdate zita network configured 
 I installed 'nfs-client' on
zita (the StripTool terminal). It now has
  
  9369   Tue Nov 12 23:05:06 2013 ranaUpdatePEMthump noise from particle counter[quote]The particle counter is back on the
IOOC location on a piece of  FOAM 
It needs this isolation, so when the pump
  
  9370   Tue Nov 12 23:48:23 2013 RANAUpdateIOOPSL pointing monitoring    
  9371   Wed Nov 13 01:35:40 2013 JenneUpdateLSCPRM motion causing trouble?

    

       
            
 xarmRIN_vs_CARM.pngASportOverlap_moveGaussianBeams.png 
  9372   Wed Nov 13 08:46:03 2013 SteveUpdateVACvertex crane repair completed

    

       
            
  
  9373   Wed Nov 13 09:31:15 2013 GabrieleUpdateLSCPRM motion causing trouble?Interesting results. When
you compute the effect of ETM motion, you
maybe should also consider that moving
  
  9374   Wed Nov 13 11:30:07 2013 SteveUpdatePEM particle counter MOVEDParticle counter moved from the top of IOOC
to the east wall
 Met1Moved.JPG 
  9375   Wed Nov 13 18:02:08 2013 JenneUpdateCDSCan't talk to AUXEY?The restore scripts from the IFO config
screen half-failed, with this error:
retrying (1/5)...
  
  9376   Wed Nov 13 18:32:04 2013 Nic, EvanUpdateISSSR560 ISS loopWe have implemented an SR560-based ISS
loop using the AOM on the PSL table. This
is a continuation of the work in 
 psl_aom_overhead.jpgaom_driver.jpgloop_on_settings.jpgfxn_gen.jpg40m_iss.pdf 
  9378   Wed Nov 13 19:22:58 2013 JenneUpdateLSCPRM motion correlated to intracavity power[Gabriele, Jenne]
Nic and Evan put the ISS together
(elog
 POPDC_sensors_30oct2013.pngAOMmodulated_POPDC_OSEM.pdf 
  9379   Wed Nov 13 19:41:55 2013 JenneUpdateISSISS AOMAOM driving from DAC:
I found that the DAC channels for
TT3 and TT4 are connected up in the simulink
  
  9380   Wed Nov 13 20:02:12 2013 Nic, EvanUpdateISSSR560 ISS loop

    

       
            
 ISS_560_rot.pdfISS_560cal.pdf 
  9382   Thu Nov 14 02:50:43 2013 JenneUpdateLSCPRM oplev measured and modeled TFIn the process of figuring out what we
can do to fix our PRM motion problem, I am
looking at the PRM oplev. 
 PRM_OL_TF_model.pngPRM_OLPIT_TF.pdfPRM_OLYAW_TF.pdf 
  9383   Thu Nov 14 02:55:26 2013 ranaUpdateSUSPRM motion correlated to intracavity power 
Some more words about the ISS ->
OSEM measurement:
  
  9384   Thu Nov 14 11:41:19 2013 SteveUpdateSUSPRM sensors effected by IR IR off for 11 minutes. The PRM 
face sensors are effected. The PRM side and
the rest of the SUS OSEMS are not effected.
 IRon_off.png 
  9386   Thu Nov 14 14:35:12 2013 SteveUpdateSUSIR effect on MC and PRM sensors Sorry to say but MC1, MC2, MC3 and
PRM face OSEMS are having the same problem
of leaking IR into the sensors
 MC_PRM_IReffect.png 
  9387   Thu Nov 14 22:23:22 2013 JenneUpdateCDSCan't talk to AUXEY?

    

       
            
  
  9388   Fri Nov 15 08:01:20 2013 SteveUpdateSUSETMY damping restoredETMY sus damping restored  ETMYsus.png 
  9389   Fri Nov 15 09:24:41 2013 SteveUpdateIOOWFS with beam dumpsThis is a proposal to move WFSs such way
that their reflected beam can be trapped.
Later ps: Nic will take care of the
 MCwfsRefTraped.jpg 
  9390   Fri Nov 15 09:27:58 2013 KojiUpdateIOOWFS with beam dumpsUnfortunately this does not work. These
WFSs are not the detectors which we can move
freely.
  
  9391   Fri Nov 15 10:19:26 2013 manasaUpdateCDSCan't talk to AUXEY?

    

       
            
  
  9392   Fri Nov 15 10:31:45 2013 SteveUpdateISSSR560 ISS loop connection

    

       
            
 ISS.png 
  9393   Fri Nov 15 10:49:55 2013 jamieUpdateCDSCan't talk to AUXEY?Please just try rebooting the vxworks machine. 
I think there is a key on the card or create
that will reset the device.  These machines
  
  9394   Fri Nov 15 12:00:28 2013 KojiUpdateCDSCan't talk to AUXEY?

    

       
            
  
  9395   Fri Nov 15 12:38:50 2013 JenneUpdateCDSCan't talk to AUXEY?

    

       
            
  
  9396   Fri Nov 15 13:26:00 2013 JenneUpdateCDSAUXEY is back

    

       
            
  
  9397   Fri Nov 15 14:08:13 2013 manasaUpdatePSLPSL Innolight shuts down again

    

       
            
  
  9398   Mon Nov 18 16:39:38 2013 SteveUpdateSUSPRM picturesPRM is aligned. IFO is not locked. It is
just flashing, including arms. Olympus SP570UZ
camera used without IR blocker. Note: PRM
 PRM1.JPGPRMsurface.JPGPRM2.JPG 
  9399   Mon Nov 18 17:00:20 2013 JenneUpdateSUSPRM picturesIt crossed my mind that, from these pictures,
it could be glow from the oplev scattered
light that is causing the problem. 
  
  9400   Mon Nov 18 19:45:42 2013 RANAUpdateSUSPRM picturesNice camera work Steve! I will use these
for publicity photos.
  
  9401   Mon Nov 18 21:02:54 2013 JenneUpdateLSCPRM oplev measured and modeled TFI have created a new filter for the PRM
oplev damping loops.  The biggest change
is an increase in the gain between 0.4 -
 PRM_OLG_NewOld.pngPRM_oplev_improvement.pdf 
  9402   Mon Nov 18 21:20:54 2013 JenneUpdateCDSCan't talk to AUXEY?

    

       
            
  
  9403   Mon Nov 18 21:26:13 2013 KojiUpdateSUSPRM picturesCan't we somehow hook up this camera to
the MUX with the movie mode? 
I think both the MUX and the sensoray
  
  9404   Mon Nov 18 21:40:24 2013 KojiUpdateLSCPRM oplev measured and modeled TFI forgot how we could turn on the PRM oplev
servo and the PRM ASC servo at the same time
without conflict.
  
  9405   Tue Nov 19 00:07:16 2013 JenneUpdateLSCGreen statusAfter I aligned the IR interferometer (no
ASS - we still need to figure out what's
going on with that), I am trying to find
  
  9406   Tue Nov 19 00:18:30 2013 JenneUpdateLSCGreen ALS wishlistEricQ said that he's going to start hanging
out at the 40m a bit, and I was thinking
about what I can have him help me with. 
  
  9407   Tue Nov 19 01:11:19 2013 JenneUpdateLSCGreen statusI am able to lock the Yarm ALS, but not
at the full gain that I should be. 
I attribute this to my mediocre alignment
  
  9408   Tue Nov 19 11:33:39 2013 SteveUpdateSUSPRM- OSEM side ccd camera is in place

    

       
            
 closetoWindowGlass.jpgDangerUnprotectedViewport.jpg 
  9409   Tue Nov 19 11:56:10 2013 manasa, jenne, ericQUpdateLSCPRM- OSEM side ccd camera is in place

    

       
            
  
  9410   Tue Nov 19 14:47:44 2013 JenneUpdateLSCPRM oplev measured and modeled TF

    

       
            
  
  9411   Tue Nov 19 14:47:59 2013 manasaUpdateLSCGreen status

    

       
            
  
  9412   Tue Nov 19 15:04:14 2013 JenneUpdateCDSCan talk to AUXEY againThe ETMY sliders on IFO_ALIGN were white
again this morning, so I went down to the
Yend and pushed the RESET button on auxey. 
  
  9413   Tue Nov 19 17:47:17 2013 JenneUpdateLSCPRMI+2arms attemptSo far this afternoon, I have redone the
IFO alignment, locked both arms with ALS,
moved both arms off resonance, locked PRMI,
  
  9414   Tue Nov 19 21:28:05 2013 manasaUpdateLSCPRMI carrier lockingSince we have never tried to lock PRMI
on carrier after the folding mirrors were
flipped, I tried to lock PRCL on carrier.
  
  9415   Tue Nov 19 21:59:35 2013 manasaUpdateLSCPRMI carrier locking

    

       
            
  
  9416   Wed Nov 20 01:10:38 2013 JenneUpdateLSCPRMI carrier lockingI have increased the gain of the MICH loop
to -100, and set FMs 2,3,7  to be triggered. 
I have also increased the PRCL gain to 2. 
  