  11140   Fri Mar 13 14:11:59 2015 ranaUpdateLSC6+ CARM->REFL transitions, 1 DARM->AS transitionSince the DARM_OUT signal is only 500 counts_peak,
I don't see why AS55 whitening needs
to be switched on.
  
  11143   Sat Mar 14 01:14:09 2015 JenneUpdateLSCMore stable DARM transitions[Jenne, Koji, Rana]

Thanks to turning off the AS55
analog whitening as well as the 1k:6k lead
 DARM_RF-only_13Mar2015.pdf 
  11144   Sun Mar 15 18:49:57 2015 JenneUpdateLSCMore stable DARM transitionsI have modified the DARM model from elog
11133, to include the fact that these
 DARM_modelVsmeas_15March2015.pngDARMresiduals.png 
  11154   Sat Mar 21 05:19:49 2015 JenneUpdateLSCIFO awake[Jenne, Den]

The problem with the ASS
turned out to be a mode that was rung up
 carm_cm_up_zip.sh.gz 
  11163   Tue Mar 24 05:05:09 2015 ericqUpdateLSCAO Path engaged[J, Q]

Terse tonight, more verbose tomorrow. 

We have succesfully achieved multiple
 CARM_DARM_AOengaged_23March2015.pdfloops.png 
  11167   Tue Mar 24 18:22:11 2015 ericqUpdateLSCAO Path engagedFor increased flatness of the AO response,
and thus less gain peaking in the CARM loop,
I reccomend turning down the MC servo VCO
 IMC_ao_Mar242015.pngIMC_olgs_Mar242015.png 
  11168   Tue Mar 24 18:47:10 2015 ericqUpdateLSCAO Path engagedJenne has more detailed notes about how
things went down last night, but I figure
I should write about how we got the
  
  11169   Wed Mar 25 03:31:18 2015 JenneUpdateLSCMeh[Jenne, Den]

Overall a "meh" night
for locking I think.  The script to
  
  11170   Wed Mar 25 08:29:31 2015 SteveUpdateLSCMeh  I turned on the HEPA at the south
end during the LSC. Sorry I ment to turn
it off.
  
  11172   Wed Mar 25 18:46:14 2015 JenneUpdateLSCREFL PDs get more lightAfter discussions during the meeting today,
I removed the PBS from the REFL path, which
gives much more light to REFL11, REFL33 and
 AS_REFL_branchingRatios_25Mar2015.png 
  11173   Wed Mar 25 18:48:11 2015 KojiSummaryLSC55MHz demodulators inspection[Koji Den EricG]

We inspected the {REFL, AS, POP}55
demodulators.
  
  11174   Wed Mar 25 21:44:20 2015 KojiUpdateLSCIFO recovery / PRFPMI locking activity[Koji, Den]

- Aligned the arms with
ASS. It had alot of offset accumulated. We
  
  11176   Thu Mar 26 16:32:32 2015 JenneUpdateLSCREFL PDs get more lightSome more words on yesterday's REFL
path work. 

The 90/10 BS that splits the light
  
  11177   Fri Mar 27 04:36:46 2015 denUpdateLSCals->pdh transition, prcl on 1f, alignmentTonight I have modified transition steps
from als to pdh signals. I have added 1:20
filters to CARM_A and DARM_A filter banks
  
  11179   Fri Mar 27 14:47:57 2015 KojiUpdateLSCals->pdh transition, prcl on 1f, alignmentJenne and I interviewd Den this afternoon
to make the things clear

- His "duty cycle" is
 CARM_transition.pdf 
  11180   Fri Mar 27 20:32:17 2015 KojiSummaryLSCLocking activity- Adjutsed the IMC WFS operating point.
The IMC refl is 0.42-0.43.

- The arms are aligned with ASS
  
  11181   Sat Mar 28 03:21:49 2015 denUpdateLSCtowards angular ffTonight I measured seismic noise coupling
to beam spot on PR2. There is coherence of
0.9 from X to PIT and Y to YAW around the
  
  11182   Tue Mar 31 02:51:39 2015 ericqUpdateLSCSome locksI had a handful of ~10 minute locks tonight.
I intended to work on the 1f PRMI transition,
but ended just familiarizing myself with
  
  11183   Tue Mar 31 03:02:44 2015 KojiUpdateLSCSome locksAssuming the carrier mode in PRC is stable
and the SB is the one moving, can we just
use the POP DC QPD to control PRM?
  
  11185   Tue Mar 31 18:27:58 2015 ericqUpdateLSCSome locks


 qpdSwitch.pngqpdAlways.png 
  11187   Wed Apr 1 03:54:15 2015 JenneUpdateLSCPRMI to 1f twiceI got the PRMI transitioned from REFL165
over to REFL55 two times tonight.  Also,
I had 2 long-ish locks, one 9 minutes, and
 FirstLock_9min_arms150_1154pm.png 
  11190   Wed Apr 1 16:52:02 2015 JenneUpdateLSCList of measurementsI'd like to get a concrete list of
measurements written down, so that it's
clear what needs to be done before I graduate.
  
  11191   Wed Apr 1 23:56:36 2015 ericqUpdateLSCX Green Power driftingSomething
funky is happening with the green
light locked to the X arm. The green transmitted
 Xgreen_drifting.png 
  11192   Thu Apr 2 01:28:34 2015 JenneUpdateLSCX Green Power driftingHave you tried a different set of laser
temperatures?  I don't remember
the value for the Xgreen, but whatever the
  
  11193   Thu Apr 2 01:45:44 2015 JenneUpdateLSCX Green Power drifting


  
  11194   Thu Apr 2 04:11:20 2015 ericqUpdateLSCNot much locking, Xover measurementA paltry two locks tonight, but not entirely
useless. I had some issues keeping the PRMI
locked, which some additional boosts helped
 CARMxOver_Apr3.pngApr2_Xover.xml.zip 
  11195   Thu Apr 2 15:34:34 2015 ericqUpdateLSCNot much locking, Xover measurementHere's the comparison of last night's
crossover measurement to my loop model. Not
stellar, but not totally off base. All of
 xOverModel.pngloopModel.png 
  11196   Thu Apr 2 17:11:28 2015 ericqUpdateLSCNot much locking, Xover measurementWhoops, I implemented the IOP downsampling
filters wrong. Once I did that, it looked
like just delay mismatch, so I added two
 xOverModel.pngloopModel.png 
  11197   Fri Apr 3 05:17:36 2015 JenneUpdateLSCPRMI to 1f twelve timesI have 12 tick marks for times I got all
the way to 1f for all 4 degrees of freedom
in the PRFPMI.  The CARM / DARM transitions
  
  11207   Wed Apr 8 03:44:48 2015 JenneUpdateLSCMediocre locking nightIt was only a mediocre locking night. 
I was foiled for a long time by 2 things,
both of which are now taken care of in the
 PRCL_R165_offsetplus10.png 
  11208   Wed Apr 8 13:26:47 2015 ericqUpdateLSCREFL55 signal back to its normal ADC inputsAs the POP55 demod board is actually demodulating
the REFL55 signal, I have connected its outputs
to the REFL55 ADC inputs. Now, we can go
  
  11210   Thu Apr 9 02:58:26 2015 ericqUpdateLSCAll 1F, all whitenedblarg. Chrome ate my elog. 

112607010 is the start of five
minutes on all whitened 1F PDs. REFL55 has
 quickLockLoss.png55_1.png55_2.png 
  11212   Fri Apr 10 03:44:51 2015 JenneUpdateLSCSome small progress, may have DAC problem?Small steps tonight, but all in the forward
direction.

On one of my better locks, I saw
 PRMI_sb_powers_9Apr2015.png 
  11213   Fri Apr 10 12:09:19 2015 ericqUpdateLSCSome small progress, may have DAC problem?



  
  11214   Fri Apr 10 17:05:45 2015 ericqUpdateLSCRelative ETM calibration (Rough MC2 calibration)I did a quick measurement get an idea of
the ETM actuator calibration, relative
to the ITMs. This will still hold if/when
 quickCal.png 
  11215   Fri Apr 10 18:39:39 2015 ericqUpdateLSCRelative ETM calibration (Rough MC2 calibration)I didn't verify that the loop gain
was low enough at the excitation frequencies.
 betterCal.png 
  11219   Wed Apr 15 02:26:41 2015 ericqUpdateLSCAttempted DRMI + ALS armsI spent some time tonight trying to revive
DRMI locking, with the arms held off on ALS. Not
much news, I haven't been able to get
  
  11222   Wed Apr 15 21:00:56 2015 JenneUpdateLSCDAC fineThe DAC was fine.  I realized tonight
that the digital filter bank outputs were
off, so I wasn't actually sending signals
  
  11254   Sun Apr 26 14:17:40 2015 JenneUpdateLSCPOXDC, POYDC unplugged for nowI have unplugged POXDC and POYDC from their
whitening inputs.  They have labels
on them which whitening channel they belong
  
  11258   Mon Apr 27 01:13:08 2015 JenneUpdateLSCPRCL angular FF not working, no locking :(I'm sad.  And frustrated. 

The PRCL angular feed forward is
not working, and without it I am having a
 Pitch_oldVsNew.pdf 
  11271   Mon May 4 12:35:49 2015 ranaUpdateLSCdrift in Y armhttp://www.ligo.caltech.edu/~misi/summary/day/20150504/

I left the arms locked last night.
Looks like the drift in the Y arm power is
  
  11275   Fri May 8 08:16:46 2015 SteveUpdateLSCdrift in Y armWhy is the Y arm drifting so much?

The " PSL FSS Slow Actuator
Adjust " was brought back to range from
 1goodday.pngYishappy.png 
  11328   Wed May 27 17:14:08 2015 ericqUpdateLSCX Aux Laser crystal temperature changedRana suspects that the lack of X beatnote
is related to the PSL laser temperature change
(ELOG
  
  11335   Fri May 29 02:05:08 2015 ericqUpdateLSCEnd Laser temperatures setBoth
green beatnotes have been found with nominal
amplitudes. (X: -30dBm Y: -20dBm), at temperatures
  
  11351   Wed Jun 10 03:19:58 2015 ericqUpdateLSCAUX PDH error measured in CDSLooking over the old noise budget in the
green locking paper, it seems the main technical
noise sources were the AUX PDH error and
 AUXspectra.png 
  11355   Fri Jun 12 17:09:58 2015 ericqUpdateLSCBeatbox needs whitening gainShort entry just to preview a new development;
more detail about this investigation will
soon follow. 
 beatGain.png 
  11356   Sat Jun 13 18:37:46 2015 ericqUpdateLSCBeatbox needs whitening gainHere are the promised details!

I was worried about the lack of
whitening gain, as I saw that the DC phase
 ADCdiagnosis.png 
  11357   Sat Jun 13 23:52:14 2015 ericqUpdateLSCBeatbox needs whitening gainNice find!

We ought to use our noise model
of the ALS signal chain to determine what
  
  11368   Mon Jun 22 12:57:09 2015 ericqSummaryLSCX/Y green beat mode overlap measurement redoneI took measurements at the green beat setup
on the PSL table, and found that our power
/ mode overlap situation is still consistent
  
  11370   Mon Jun 22 14:53:37 2015 ranaSummaryLSCX/Y green beat mode overlap measurement redone
Why is there a factor of 20 power
difference? Some of it is the IR laser power
difference, but I thought that was just a
  