  14007   Fri Jun 22 15:13:47 2018 gautamUpdateCDSDTT workingSeems like DTT also works now. The trick
seems to be to run 
 Screenshot_from_2018-06-22_15-12-37.png 
  14009   Fri Jun 22 18:30:21 2018 gautamUpdateSUSITMY_UL sensorI think if the magnet fell off, we would
see high DC signal, and not 0 as we do now.
I suspect satellite box or PD readout board/cabling.
  
  14012   Sun Jun 24 20:02:07 2018 gautamUpdateSUSSome notes about coil driver noiseSummary:

For a series resistance of 4.5
kohm, we are suffering from the noise-gain
 CoilDriverSchematic.pdfD010001_2k_fastOnly_2.25k.pdfD010001_4k_fastOnly_4.5k.pdf 
  14019   Tue Jun 26 16:28:00 2018 gautamUpdateSUSCoil driver protoboard characterizationI wanted to investigate my coil driver
noise measurement technique under more controlled
circumstances, so I spent yesterday setting
 IMG_7060.JPGETMXstitchced.pdfETMXfullSpan.pdfPSRR.pdf 
  14024   Wed Jun 27 18:12:04 2018 gautamUpdateElectronicsCoil driver dewhiteningSummary:

I've been thinking about what
we need to do to the de-whitening boards
 DeWhiteningSketch.pdf 
  14027   Wed Jun 27 21:18:00 2018 gautamUpdateCDSLab maintenance scripts from NODUS---->MEGATRONI moved the N2 check script and the disk
usage checking script from the (sudo) crontab
of 
  
  14032   Thu Jun 28 16:48:27 2018 gautamUpdateSUSSOS cage towers For the upcoming vent, we'd like to
rotate the SOS towers to correct for the
large YAW bias voltages used for DC alignment
  
  14038   Thu Jul 5 10:15:30 2018 gautamUpdateSUSPRM watchdog trippedPRM watchdog was tripped around 7:15am
PT today morning. I restored it.
 PRM_watchdogTrip.png 
  14055   Thu Jul 12 11:13:39 2018 gautamUpdateGeneralOMC revivalAaron and I are going to do the checkout
of the OMC electronics outside vacuum today.
At some point, we will also want to run a
  
  14061   Thu Jul 12 23:59:14 2018 gautamUpdateGeneralVent objectives and prepVent
objectives:
  
  14063   Fri Jul 13 02:52:11 2018 gautamUpdateGeneralVent objectives and prep[KA,
GV]
 preVentStatus.png 
  14068   Fri Jul 13 18:01:13 2018 gautamUpdateGeneralLow power MCAfter getting the go ahead from Steve,
I removed the physical beam block on the
PSL table, sent the beam into the IFO, and
  
  14075   Tue Jul 17 01:07:40 2018 gautamUpdateSUSETMY EQ stopsFor the heater setup on EY table, I EQ-stopped
ETMY. Only
  
  14085   Thu Jul 19 01:56:25 2018 gautamSummaryVACAUX pump shutdown[koji,
gautam]

Per Steve's instructions, we
  
  14094   Sat Jul 21 01:06:49 2018 gautamSummaryThermal CompensationY arm lockingI implemented this today. For now, the
LSC output matrix is set to actuate on MC2
for Y arm locking. As expected, the transmission
  
  14095   Sat Jul 21 01:14:02 2018 gautamUpdateOMCPZT Jena driver board check[Aaron, gautam]

We did a quick check of this
board today. Main takeaways:
  
  14101   Tue Jul 24 09:47:51 2018 gautamUpdateCamerasDeveloping neural networks on simulated videoI was thinking a little more about the
way we are training the network for the current
topology - because the network has no recurrent
  
  14104   Wed Jul 25 22:46:15 2018 gautamConfigurationComputersNDS access from outsideAfter this work, I've been having some
trouble getting data with Python NDS. Eventually,
I figured out that the nds connection request
  
  14107   Fri Jul 27 02:30:51 2018 gautamUpdateGeneralGlitchy MCKevin and I saw some weird IMC / PEM BLRMS
behaviour today - see Attached screenshot.
Not sure what was happening with the IMC,
 38.png 
  14115   Mon Jul 30 11:05:44 2018 gautamUpdateSUSIFO SUS wonkyWhen I came in this morning:


PMC was unlocked.
Seis
BLRMS were off scale.
ITMX OSEM
 IMG_7102.JPG 
  14117   Mon Jul 30 16:11:54 2018 gautamUpdateSUSTrillium interface box is broken[koji,
steve, gautam]
  
  14122   Wed Aug 1 19:41:15 2018 gautamSummaryComputersRTCDS recovery, c1ioo changes[Gautam Koji]

After this work, we recovered the
nominal RTCDS state. The main points were:
 CDS_overview.png 
  14123   Wed Aug 1 20:44:57 2018 gautamSummaryComputersc1omc model (re?)createdThe main motivation behind adding a DAC
card in c1ioo was to setup an RTCDS model
for the OMC. Attachment #1 shows the new
 CDS_OVERVIEW_withOMC.png 
  14125   Thu Aug 2 20:47:29 2018 gautamSummaryElectronicsX Green "Mystery" solvedI walked
down to the X end and found that the entire
  
  14126   Thu Aug 2 20:54:18 2018 gautamSummaryComputersc1omc model looks stableActually, c1lsc had crashed again sometime
last night so I had to reboot everything
this morning. I used the reboot script again,
  
  14128   Fri Aug 3 14:35:56 2018 gautamSummaryElectronicsEX AUX electronics power restoredSteve and I restored the power to the EX
AUX electronics rack. The power strip on
the lowest shelf of the AUX rack now
  
  14129   Fri Aug 3 15:53:25 2018 gautamUpdateSUSLow noise bias path ideaSummary:

The idea we are going with to push
the coil driver noise contribution down is
 LT1055_precOpAmp.pdf 
  14131   Fri Aug 3 18:54:58 2018 gautamUpdateSUSGlitchy MC1The wall StripTool indicated that the IMC
wasn't too happy when I came in today.
Specifically:
 MC1_sensorAnomaly.png 
  14132   Fri Aug 3 19:02:11 2018 gautamUpdateASSX arm ASS recovery[koji,
gautam]

After I effected the series resistance
  
  14133   Sun Aug 5 13:28:43 2018 gautamUpdateCDSc1lsc flakySince the lab-wide
computer shutdown last Wednesday, all
the realtime models running on c1lsc have
  
  14134   Sun Aug 5 13:45:00 2018 gautamUpdateSUSETMX trippedIndependent from the problems the vertex
machine has been having (I think, unless
it's something happening over the shared
 ETMX_tripped.pngETMX_tripped_zoom.png 
  14135   Sun Aug 5 15:43:50 2018 gautamUpdateSUSAnother low noise bias path ideaOK, how about this:


Attachment
 HV_Bias_schematic.pdfTF.pdfbias.pdfHVbias_currentNoise.pdf 
  14136   Mon Aug 6 00:26:21 2018 gautamUpdateCDSMore CDS woesI spent most of today fighting various
CDS errors.


I rebooted c1lsc around
 CDSoverview.png 
  14139   Mon Aug 6 14:38:38 2018 gautamUpdateCDSMore CDS woesStability was short-lived it seems. When
I came in this morning, all models on c1lsc
were dead already, and now c1sus is also
 CDScrash.pngMC1failures.png 
  14140   Mon Aug 6 19:49:09 2018 gautamUpdateCDSMore CDS woesI've left
the c1lsc frontend shutdown for now,
 IMG_7106.JPG 
  14142   Tue Aug 7 11:30:46 2018 gautamUpdateCDSMore CDS woesOvernight, all models on c1sus and c1ioo
seem to have had no stability issues, supporting
the hypothesis that timing issues stem from
  
  14143   Tue Aug 7 22:28:23 2018 gautamUpdateCDSMore CDS woesI am starting the c1x04 model (IOP) on
c1lsc to see how it behaves overnight.

Well, there was apparently an immediate
  
  14146   Wed Aug 8 23:03:42 2018 gautamUpdateCDSc1lsc model startedAs part of this slow but systematic debugging,
I am turning on the c1lsc model overnight
to see if the model crashes return.
  
  14147   Wed Aug 8 23:06:59 2018 gautamUpdateSUSAnother low noise bias path ideaToday while Rich Abbott was here, Koji
and I had a brief discussion with him about
the HV amplifier idea for the coil driver
  
  14148   Thu Aug 9 02:12:13 2018 gautamUpdateCOCSouth East or West?Summary:

For operating the SRC in the "Signal-Recycled"
tuning, the SRC macroscopic length needs
  
  14149   Thu Aug 9 12:31:13 2018 gautamUpdateCDSCDS status updateThe model seems to have run without issues
overnight. Not completely related, but the
MC1 shadow sensor signals also don't
  
  14150   Thu Aug 9 12:40:14 2018 gautamUpdateSUSETMX trip follow-upA brief follow-up on this since we discussed
this at the meeting yesterday: the attached
DV screenshot shows the full 2k data for
 ETMXglitch.png 
  14151   Thu Aug 9 22:50:13 2018 gautamUpdateCDSAlignSoft script modifiedAfter this
work of increasing the series resistance
on ETMX, there have been numerous occassions
 MichelsonFringing.png 
  14152   Fri Aug 10 01:10:56 2018 gautamUpdateLSCSome vertex locking restoredFor
the first time after the whirlwind vent,
 PRMIcarrier.png 
  14154   Fri Aug 10 16:43:50 2018 gautamConfigurationUpgradeParts list for BHDCan we use the leakage
beam from MMT2 on the OMC table as the
LO beam? I can't find the spec for this
  
  14157   Mon Aug 13 11:44:32 2018 gautamUpdateComputer Scripts / ProgramsPatch updates on nodusLarry W said that some security issues
were flagged on nodus. So I ran

  
  14160   Tue Aug 14 00:27:55 2018 gautamUpdateLSCLocking prepIn preparation for attempting some DRMI
locking, I did the following:


Slow machine reboots for
  
  14161   Tue Aug 14 00:50:32 2018 gautamUpdateASSX arm ASS still not quite right?While working on the single arm alignment,
I noticed that today, i was able to get the
X arm transmission back to ~1.22, and the
 POXPOY.pngIMG_7108.JPG 
  14162   Tue Aug 14 02:01:12 2018 gautamUpdateLSCDRMI locking - partial successAfter tweaking the AS55 demod phase, SRM
alignment, triggering settings, I got a few
brief
 DRMI.png 
  14164   Wed Aug 15 12:15:24 2018 gautamUpdateCOCMacroscopic SRC length for SR tuningSummary:

It
 SRC_MCMC_shortTerm.pdfSRC_dists_shortTerm.pdf 