40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 217 of 341  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  14085   Thu Jul 19 01:56:25 2018 gautamSummaryVACAUX pump shutdown[koji,
gautam]

Per Steve's instructions, we
  
  14094   Sat Jul 21 01:06:49 2018 gautamSummaryThermal CompensationY arm lockingI implemented this today. For now, the
LSC output matrix is set to actuate on MC2
for Y arm locking. As expected, the transmission
  
  14095   Sat Jul 21 01:14:02 2018 gautamUpdateOMCPZT Jena driver board check[Aaron, gautam]

We did a quick check of this
board today. Main takeaways:
  
  14101   Tue Jul 24 09:47:51 2018 gautamUpdateCamerasDeveloping neural networks on simulated videoI was thinking a little more about the
way we are training the network for the current
topology - because the network has no recurrent
  
  14104   Wed Jul 25 22:46:15 2018 gautamConfigurationComputersNDS access from outsideAfter this work, I've been having some
trouble getting data with Python NDS. Eventually,
I figured out that the nds connection request
  
  14107   Fri Jul 27 02:30:51 2018 gautamUpdateGeneralGlitchy MCKevin and I saw some weird IMC / PEM BLRMS
behaviour today - see Attached screenshot.
Not sure what was happening with the IMC,
 38.png 
  14115   Mon Jul 30 11:05:44 2018 gautamUpdateSUSIFO SUS wonkyWhen I came in this morning:


PMC was unlocked.
Seis
BLRMS were off scale.
ITMX OSEM
 IMG_7102.JPG 
  14117   Mon Jul 30 16:11:54 2018 gautamUpdateSUSTrillium interface box is broken[koji,
steve, gautam]
  
  14122   Wed Aug 1 19:41:15 2018 gautamSummaryComputersRTCDS recovery, c1ioo changes[Gautam Koji]

After this work, we recovered the
nominal RTCDS state. The main points were:
 CDS_overview.png 
  14123   Wed Aug 1 20:44:57 2018 gautamSummaryComputersc1omc model (re?)createdThe main motivation behind adding a DAC
card in c1ioo was to setup an RTCDS model
for the OMC. Attachment #1 shows the new
 CDS_OVERVIEW_withOMC.png 
  14125   Thu Aug 2 20:47:29 2018 gautamSummaryElectronicsX Green "Mystery" solvedI walked
down to the X end and found that the entire
  
  14126   Thu Aug 2 20:54:18 2018 gautamSummaryComputersc1omc model looks stableActually, c1lsc had crashed again sometime
last night so I had to reboot everything
this morning. I used the reboot script again,
  
  14128   Fri Aug 3 14:35:56 2018 gautamSummaryElectronicsEX AUX electronics power restoredSteve and I restored the power to the EX
AUX electronics rack. The power strip on
the lowest shelf of the AUX rack now
  
  14129   Fri Aug 3 15:53:25 2018 gautamUpdateSUSLow noise bias path ideaSummary:

The idea we are going with to push
the coil driver noise contribution down is
 LT1055_precOpAmp.pdf 
  14131   Fri Aug 3 18:54:58 2018 gautamUpdateSUSGlitchy MC1The wall StripTool indicated that the IMC
wasn't too happy when I came in today.
Specifically:
 MC1_sensorAnomaly.png 
  14132   Fri Aug 3 19:02:11 2018 gautamUpdateASSX arm ASS recovery[koji,
gautam]

After I effected the series resistance
  
  14133   Sun Aug 5 13:28:43 2018 gautamUpdateCDSc1lsc flakySince the lab-wide
computer shutdown last Wednesday, all
the realtime models running on c1lsc have
  
  14134   Sun Aug 5 13:45:00 2018 gautamUpdateSUSETMX trippedIndependent from the problems the vertex
machine has been having (I think, unless
it's something happening over the shared
 ETMX_tripped.pngETMX_tripped_zoom.png 
  14135   Sun Aug 5 15:43:50 2018 gautamUpdateSUSAnother low noise bias path ideaOK, how about this:


Attachment
 HV_Bias_schematic.pdfTF.pdfbias.pdfHVbias_currentNoise.pdf 
  14136   Mon Aug 6 00:26:21 2018 gautamUpdateCDSMore CDS woesI spent most of today fighting various
CDS errors.


I rebooted c1lsc around
 CDSoverview.png 
  14139   Mon Aug 6 14:38:38 2018 gautamUpdateCDSMore CDS woesStability was short-lived it seems. When
I came in this morning, all models on c1lsc
were dead already, and now c1sus is also
 CDScrash.pngMC1failures.png 
  14140   Mon Aug 6 19:49:09 2018 gautamUpdateCDSMore CDS woesI've left
the c1lsc frontend shutdown for now,
 IMG_7106.JPG 
  14142   Tue Aug 7 11:30:46 2018 gautamUpdateCDSMore CDS woesOvernight, all models on c1sus and c1ioo
seem to have had no stability issues, supporting
the hypothesis that timing issues stem from
  
  14143   Tue Aug 7 22:28:23 2018 gautamUpdateCDSMore CDS woesI am starting the c1x04 model (IOP) on
c1lsc to see how it behaves overnight.

Well, there was apparently an immediate
  
  14146   Wed Aug 8 23:03:42 2018 gautamUpdateCDSc1lsc model startedAs part of this slow but systematic debugging,
I am turning on the c1lsc model overnight
to see if the model crashes return.
  
  14147   Wed Aug 8 23:06:59 2018 gautamUpdateSUSAnother low noise bias path ideaToday while Rich Abbott was here, Koji
and I had a brief discussion with him about
the HV amplifier idea for the coil driver
  
  14148   Thu Aug 9 02:12:13 2018 gautamUpdateCOCSouth East or West?Summary:

For operating the SRC in the "Signal-Recycled"
tuning, the SRC macroscopic length needs
  
  14149   Thu Aug 9 12:31:13 2018 gautamUpdateCDSCDS status updateThe model seems to have run without issues
overnight. Not completely related, but the
MC1 shadow sensor signals also don't
  
  14150   Thu Aug 9 12:40:14 2018 gautamUpdateSUSETMX trip follow-upA brief follow-up on this since we discussed
this at the meeting yesterday: the attached
DV screenshot shows the full 2k data for
 ETMXglitch.png 
  14151   Thu Aug 9 22:50:13 2018 gautamUpdateCDSAlignSoft script modifiedAfter this
work of increasing the series resistance
on ETMX, there have been numerous occassions
 MichelsonFringing.png 
  14152   Fri Aug 10 01:10:56 2018 gautamUpdateLSCSome vertex locking restoredFor
the first time after the whirlwind vent,
 PRMIcarrier.png 
  14154   Fri Aug 10 16:43:50 2018 gautamConfigurationUpgradeParts list for BHDCan we use the leakage
beam from MMT2 on the OMC table as the
LO beam? I can't find the spec for this
  
  14157   Mon Aug 13 11:44:32 2018 gautamUpdateComputer Scripts / ProgramsPatch updates on nodusLarry W said that some security issues
were flagged on nodus. So I ran

  
  14160   Tue Aug 14 00:27:55 2018 gautamUpdateLSCLocking prepIn preparation for attempting some DRMI
locking, I did the following:


Slow machine reboots for
  
  14161   Tue Aug 14 00:50:32 2018 gautamUpdateASSX arm ASS still not quite right?While working on the single arm alignment,
I noticed that today, i was able to get the
X arm transmission back to ~1.22, and the
 POXPOY.pngIMG_7108.JPG 
  14162   Tue Aug 14 02:01:12 2018 gautamUpdateLSCDRMI locking - partial successAfter tweaking the AS55 demod phase, SRM
alignment, triggering settings, I got a few
brief
 DRMI.png 
  14164   Wed Aug 15 12:15:24 2018 gautamUpdateCOCMacroscopic SRC length for SR tuningSummary:

It
 SRC_MCMC_shortTerm.pdfSRC_dists_shortTerm.pdf 
  14165   Wed Aug 15 19:18:07 2018 gautamUpdateSUSAnother low noise bias path ideaI took another pass at this. Here is what
I have now:

Attachment
 HV_Bias.pdfHVamp_TF.pdfHVamp_noises.pdfcurrentNoises.pdfHVamp.fil.zip 
  14166   Wed Aug 15 21:27:47 2018 gautamUpdateCDSCDS status updateStarting c1cal
now, let's see if the other c1lsc FE
models are affected at all... Moreover, since
  
  14169   Thu Aug 16 23:06:50 2018 gautamUpdateSUSAnother low noise bias path ideaI had a very fruitful discussion with Rich
about this circuit today. He agreed
with the overall architecture, but made the
 HVamp_schem.PDFHvamp.zip 
  14192   Tue Sep 4 10:14:11 2018 gautamUpdateCDSCDS status updatec1lsc crashed again. I've contacted
Rolf/JHanks for help since I'm out of
ideas on what can be done to fix this
  
  14194   Thu Sep 6 14:21:26 2018 gautamUpdateCDSADC replacement in c1lsc expansion chassisTodd E. came by this morning and gave us
(i) 1x new ADC card and (ii) 1x roll of 100m
(2017 vintage) PCIe fiber. This afternoon,
 CDSoverview.png 
  14195   Fri Sep 7 12:35:14 2018 gautamUpdateCDSADC replacement in c1lsc expansion chassisLooks like the ADC was not to blame, same
symptoms persist.

 Screenshot_from_2018-09-07_12-34-52.png 
  14198   Mon Sep 17 12:28:19 2018 gautamUpdateIOOPMC and IMC relocked, WFS inputs turned offThe PMC and IMC were unlocked. Both were
re-locked, and alignment of both cavities
were adjusted so as to maximize MC2 trans
  
  14202   Thu Sep 20 11:29:04 2018 gautamUpdateCDSNew PCIe fiber housed[steve,
yuki, gautam]
 PCIeFiberSwap.pngPCIeFiberSwap_FBrebooted.png 
  14203   Thu Sep 20 16:19:04 2018 gautamUpdateCDSNew PCIe fiber install postponed to tomorrow[steve,
gautam]
  
  14206   Fri Sep 21 16:46:38 2018 gautamUpdateCDSNew PCIe fiber installed and routed[steve,
koji, gautam]
 PCIeFiber.pngIMG_5878.JPG 
  14207   Fri Sep 21 16:51:43 2018 gautamUpdateVACc1vac1 is unresponsiveSteve pointed out that some of the vacuum
MEDM screen fields were reporting "NO
COMM". Koji confirmed that this is a
  
  14215   Mon Sep 24 15:06:10 2018 gautamUpdateVACc1vac1 reboot + TP1 controller replacement[steve, gautam]

Following the procedure in this
 beforeReboot.pngafterReboot.pngCC1.png 
  14222   Mon Oct 1 20:39:09 2018 gautamConfigurationASCc1asyWe need to set up a copy of the c1asx   
ELOG V3.1.3-