40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 216 of 344  Not logged in ELOG logo
ID Date Author Type Categoryup Subject Text Attachments
  10810   Wed Dec 17 14:42:13 2014 JenneUpdateLSCPRMI loops need helpEricQ's crazy people filter has been deleted. 
I'm trying to lock right now, to see if all
is well in the world.
  
  10814   Thu Dec 18 02:23:34 2014 ericqUpdateLSCLocking update [ericq, Diego]
Some locking efforts tonight; many
locklosses due to PRC angular motion. Furthest
 15lockloss.png15spec.pdf 
  10818   Fri Dec 19 15:59:49 2014 JenneUpdateLSCLockloss from WedI swapped out one of the channels on Q's
lockloss plotter - we don't need POP22Q,
but I do want the PC drive.  
 1102929772_PCdriveRailed.png 
  10856   Tue Jan 6 03:09:17 2015 diegoUpdateLSCPRFPMI status & IFO status [Jenne, Rana, EricQ, Diego]
Tonight we worked on getting the
IFO back in a working status after the break,
 Lockloss_20150106_074552.pngLockloss_20150106_074552_zoom.png 
  10857   Tue Jan 6 03:13:09 2015 ericqUpdateLSCPRFPMI status & IFO statusTwo plots from tonight:
Lock loss. Based on the fact that
it looked like the DARM servo was running
 Jan6lockloss1_zoom.pngJan6_asdcjump.png 
  10860   Wed Jan 7 02:54:09 2015 JenneUpdateLSCFiddling with DARM filtersOne of the things that we had talked about
last night was the totally tiny amount of
phase margin that we have in the CARM and
 DARM_design_orig.pdf 
  10861   Wed Jan 7 02:56:15 2015 diegoUpdateLSCUGF Servo for DARM [Jenne, Diego]
Today we began implementing the UGF
Servos. Things we did:
  
  10862   Wed Jan 7 03:04:13 2015 JenneUpdateLSCTRY (thorlabs pd) weird noise[Jenne, Diego, Rana]
This is a note about work done last
night. 
 TRY_60Hz_peaks_5Jan2015.pdf 
  10863   Wed Jan 7 03:09:15 2015 JenneUpdateLSCPRFPMI status & IFO statusAs a warm-up after the holidays, before
the real locking began, I installed 1064nm
bandpass filters in front of the transmission
  
  10864   Wed Jan 7 09:44:33 2015 ericqUpdateLSCDARM phase budgetAs Jenne mentioned, I created a model of
the DARM OLG to see why we have so little
phase margin. However, it turns out I
 DarmPhaseBudget.pdfDarmOLGresidual.pdf2015-01-DARMphase.zip 
  10865   Wed Jan 7 11:20:22 2015 SteveUpdateLSCX arm T-QPD gets SM1 thread adapterC1:SUS-ETMX_QPD is removed and internal
SM1 thread adapter epoxied into position
as it is at
  
  10868   Wed Jan 7 13:39:42 2015 ChrisUpdateLSCDARM phase budgetI think the dolphin and RFM transit times
are double-counted in this budget. As I understand
it, all IPC transit times are already built
  
  10869   Wed Jan 7 14:16:27 2015 JenneUpdateLSCtrans QPDs realignedNow that both end transmission QPDs have
the line filters, I aligned them.
I locked and aligned the IR using
  
  10872   Wed Jan 7 15:53:01 2015 JenneUpdateLSCDC PD analog settings exposedI have added another block to the LSC screen
(and made the corresponding sub-screen) to
expose the analog settings for the DC photodiodes. 
  
  10875   Thu Jan 8 02:52:09 2015 ericqUpdateLSCUGF Servo for LSCI added UGF servos for the DRMI DoFs, after
creating a library block for the servos.
I also deleted the FMs before the phase rotation,
  
  10876   Thu Jan 8 03:09:07 2015 JenneUpdateLSCToward variable finesse locking[Jenne, EricQ, Rana]
Tonight we started prepping for an
attempt at variable finesse locking. 
  
  10887   Tue Jan 13 00:42:15 2015 JenneUpdateLSCError signals for MICH with variable finesse techniqueIn order to know where we should try to
make the transition from REFL##Q to ASDC
for MICH, I did a quick Optickle simulation
 ErrSigs_vsMICHoffset_PRMI.pngErrSigs_vsMICHoffset_PRFPMI_3nmCARMoffset.pngErrSigs_vsMICHoffset_PRFPMI_1nmCARMoffset.pngErrSigs_vsMICHoffset_PRFPMI_0nmCARMoffset.pngErrSigs_vsMICHoffset_PRFPMI_3nmCARMoffset_zoom.png 
  10888   Tue Jan 13 01:11:51 2015 diegoUpdateLSCResponse of error signals to MICH EXCFor several MICH offsets, I measured the
response of REFL33Q, ASDC and the ratio ASDC/POPDC
to a MICH EXC. It appears that there is no
 MICH_to_REFL33Q_ASDC_12Jan2015_1.pdfMICH_to_REFL33Q_ASDC_12Jan2015_2.pdfMICH_to_REFL33Q_ASDC_12Jan2015_3.pdf 
  10891   Tue Jan 13 03:58:27 2015 JenneUpdateLSCTransitioned to ASDC MICH (PRMI and PRFPMI)[Jenne, Diego, EricQ]

Hopefully there will be more later,
but Chiara just went down (network? other? 
  
  10896   Tue Jan 13 15:11:30 2015 diegoUpdateLSCTransitioned to ASDC MICH (PRMI and PRFPMI)These are the parameters of the UGF servos
we used last night:

  
  10900   Wed Jan 14 03:42:31 2015 JenneUpdateLSCThoughts on going forward with variable finesse[Jenne, Rana]

We tried locking with the variable
finesse MICH offset technique again today. 
  
  10901   Wed Jan 14 19:27:09 2015 ericqUpdateLSCUGF servo now linear againThe UGF servos have been moved to the control
point, are are once again totally linear!
  
  10902   Thu Jan 15 03:18:11 2015 diegoUpdateLSCUGF servo now linear againThe UGF servos were recommissioned today:


suitable values of frequency,
excitation, phases and gain were found;
the
  
  10903   Thu Jan 15 04:41:01 2015 JenneUpdateLSCThoughts on going forward with variable finesse[Jenne, Diego]

Life would be easier with the UGF
servos working.  As Diego already elogged,
  
  10904   Thu Jan 15 14:28:14 2015 JenneUpdateLSCLSC model change ideaSomething that kind of drives me crazy
with our current LSC model setup is that
I can't make "finished" error
 SwitchableErrorSignalProposal_Jan2015.pdf 
  10910   Fri Jan 16 03:31:35 2015 JenneUpdateLSCLSC model change implementedOkay, it has taken me almost exactly 12
hours (with a dinner break), but I have implemented
this change.
 LSCorig_15Jan2015.pngLSCpost_15Jan2015.png 
  10911   Fri Jan 16 04:14:05 2015 diegoUpdateLSCUGF servo now linear againUGF Servos' commissioning still going
on, updates of today:


on Rana's suggestion,
  
  10914   Fri Jan 16 18:46:15 2015 KojiUpdateLSCLSC model change implementedWas the screen modified directly on LSC_OVERVIEW.adl?
Even if so, that's OK. I'll
incorporate the change to the screen making
  
  10915   Fri Jan 16 20:01:32 2015 JenneUpdateLSCLSC model change implementedNope, I used the script.

Yesterday's changes were mostly
to the generateLSCscreen/C1LSC_OVERVIEW_INPUT_MATRIX.adl
  
  10916   Fri Jan 16 20:37:52 2015 diegoUpdateLSCUGF servo now linear againI found an error in the model of the UGF
servos, I have now corrected it; for future
reference, now the division between TEST2
  
  10917   Sat Jan 17 01:10:36 2015 JenneUpdateLSCSome locking, may need to modify UGF part againI have been playing with the IFO tonight. 
Mostly, I wanted to make sure that all of
the scripts for the carm_cm_up sequence were
  
  10923   Tue Jan 20 15:09:01 2015 JenneUpdateLSCLSC model change implemented 




  
  10925   Tue Jan 20 20:03:17 2015 JenneUpdateLSCALS lock not staying?The Xarm ALS has been a little funky today. 

First, the green and the arm-axis
would not stay co-aligned.  I'm
  
  10926   Tue Jan 20 21:58:04 2015 diegoUpdateLSCSome locking, may need to modify UGF part again 




 UGF_SERVO_MDL.png 
  10927   Wed Jan 21 15:27:47 2015 JenneUpdateLSCFixed LSC model bugThis problem with the CARM loop last night
was the fault of a bug that I had put into
the LSC model last week.  When I gave
  
  10929   Thu Jan 22 03:21:24 2015 JenneUpdateLSCLocks with large MICH offsets[Jenne, Diego, EricQ]

Tonight we worked on the acquisition
sequence (including re-re-re-commissioning
 MICHoffset65percent.pnglockloss_21Jan2015_MICHhittingRails.png 
  10933   Fri Jan 23 02:11:40 2015 JenneUpdateLSCCARM filters modified slightly[Jenne, Diego]

One of tonight's goals was
to tweak the CARM filters, so that we could
 plot.pngCARM_22Jan2015.pdf 
  10938   Fri Jan 23 19:38:02 2015 JenneUpdateLSCcarm_cm_up supports both signs of CARM offsetA small change, but now the carm_up script
supports both sides of the CARM offset. 
After the arms are locked with ALS it asks
  
  10942   Tue Jan 27 04:11:21 2015 JenneUpdateLSCSmall tweaks to the locking[Jenne, Diego, EricQ]

We did a series of small things
that may have helped with the locking, although
 CARM_27Jan2015_JCD.pdfDARM_27Jan2015.pdf 
  10944   Tue Jan 27 15:45:26 2015 diegoUpdateLSCSmall tweaks to the lockingThe UGF Servo medm page has been updated
to reflect the last changes, namely the return
of the sum of squares and the disappearance
  
  10947   Wed Jan 28 03:01:24 2015 JenneUpdateLSCTransitioned DARM to AS55Q[Jenne, Diego]

Tonight
we were able to transition DARM from DC transmission
  
  10949   Wed Jan 28 14:19:02 2015 ranaUpdateLSCTransitioned DARM to AS55QWhy AS55/(TRX + TRY) instead of just TRX?
Isn't (TRX+TRY) controlled by CARM?
  
  10953   Thu Jan 29 04:27:35 2015 ericqUpdateLSCCARM on REFL11[ericq, Diego]

Tonight,
 Jan29_REFL11_lockloss.png 
  10960   Fri Jan 30 03:12:15 2015 diegoUpdateLSCCARM on REFL11I[Jenne, Diego]

Tonight we continued following
the plan of last night: perform the transition
 PRCL_29Jan2015_Weird_Shape.pdfArmPowers20_MICHoffsetBeingReduced_0CARMoffset_29Jan2015.pdf 
  10962   Sat Jan 31 01:34:12 2015 JenneUpdateLSCNot able to engage AO pathNothing earth-shattering today.

A few things of note:


I checked the coherence
 PRCL_CARM_Coupling_30Jan2015.pngPRCL_CARM_Coupling_lockloss_30Jan2015.png 
  10965   Mon Feb 2 22:59:49 2015 diegoUpdateLSCCM board input switched to AS55[Diego, Jenne]

We just changed the input to the
CM board from REFL11 to AS55.
  
  10966   Tue Feb 3 04:01:55 2015 diegoUpdateLSCCM servo & AO path status[Diego, Jenne]

Tonight we worked on the CM board
and AO path:
 CARM_03-02-2015_031754.pdf 
  10969   Tue Feb 3 16:36:33 2015 ericqUpdateLSCCM servo & AO path statusI have removed REFLDC and the SR560 offsetter
from the CM board IN2. Now, analog AS55 I
lives there, for our single arm testing.
 yarmAO.pdf 
  10971   Wed Feb 4 04:51:14 2015 diegoUpdateLSCCARM Transition to REFL11 using CM_SLOW Path[Diego, Jenne, Eric]

Tonight we kept on following our
current strategy for locking the PRFPMI:
 CARM_3Feb2015_CarmBwasCMslow_CarmAwasLiveALS.pdfCARM_3Feb2015_CarmBwasCMslow_CarmAwasLiveALS_Coh.pdfGlitch_in_CARM_and_PRCL_3Feb2015.pngslowCM_04-02-2015_042805.png 
  10972   Wed Feb 4 14:30:05 2015 ericqUpdateLSCASDC Whitening GainAt the lunch meeting, we were thinking
about the exess high frequency content of
the MICH control signal, which leads to railing
  
ELOG V3.1.3-