  1001   Fri Sep 26 19:08:43 2008 ranaConfigurationPSLRefcav Trans: PD + Camera + DumpsI went out to improve the Refcav trans path.

I removed all ND filters to get rid of the
  
  1923   Tue Aug 18 14:24:43 2009 YoichiSummaryPSLReference Cavity InspectionRana, Koji, Yoichi

To see why the reflected beam from the RC
  
  3240   Fri Jul 16 20:25:52 2010 MeganUpdatePSLReference Cavity InsulationRana and I
1) took the temperature sensors off
the reference cavity;
 DSC_2271.JPGDSC_2266.JPG 
  3241   Fri Jul 16 23:53:27 2010 RanaUpdatePSLReference Cavity InsulationFrom the trend, it seems that the Reference
Cavity's temperature servo is working fine
with the new copper foil. I was unable to
  
  3280   Fri Jul 23 16:02:16 2010 RanaUpdatePSLReference Cavity InsulationThis is the trend so far with the copper
foil wrapping. According to Megan's calculation,
we need ~1 mm of foil and the thickness of
 Untitled.png 
  3282   Fri Jul 23 21:14:29 2010 RanaUpdatePSLReference Cavity InsulationI wrapped another ~3 layers onto there.
It occurs to me now that we could just get
some 2mm thick copper plates made to fit
  
  2732   Mon Mar 29 21:43:27 2010 AlbertoConfigurationPSLReference Cavity PD Noise Spectrum[Rana, Alberto]
This evening we measured the noise
spectrum of the reference cavity PD used
 2010-03-29_FSS_PD_shotnoise_and_darknoise.png2010-03-29_FSS_PD_shotnoise_and_darknoise.png 
  2733   Tue Mar 30 06:37:32 2010 ranaConfigurationPSLReference Cavity PD Noise SpectrumSome more words about the RFAM: I noticed
that there was an excess RFAM by unlocking
the RC and just looking at the RF out with
 rc.png 
  2759   Sat Apr 3 11:35:47 2010 ranaConfigurationPSLReference Cavity PD Noise SpectrumThe units on this
plot are completely bogus - we know that
the thermal noise from the resonant part
  
  2760   Sat Apr 3 16:07:40 2010 AlbertoConfigurationPSLReference Cavity PD Noise Spectrum I was aware of a problem on those
units since I acquired the data. Then it
wasn't totally clear to me which were the
 2010-03-29_FSS_PD_shotnoise_and_darknoise.png 
  2742   Wed Mar 31 15:31:53 2010 steveUpdatePSLReference Cavity RF PD base upgraded


   
        
            
 brspdbs.JPG 
  1954   Wed Aug 26 19:58:14 2009 Rana, AlbertoUpdatePSLReference Cavity Temperature Control: MINCO PID removedSummary: This afternoon we managed
to get the temperature control of the reference
cavity working again.
 rc.png 
  1956   Thu Aug 27 13:42:08 2009 ranaSummaryPSLReference Cavity Temperature Control: psl.db changesI made the changes
to the psl.db to handle the new Temperature
  
  1018   Wed Oct 1 23:21:03 2008 YoichiConfigurationPSLReference cavity reflection cameraI re-centered the reference cavity reflection
camera, which has been mis-aligned for a
while.
  
  1915   Mon Aug 17 02:05:49 2009 Yoichi,ranaUpdatePSLReference cavity reflection looks badRana, Yoichi

It has been a well known fact that the reference
 P8170113.JPGUntitled.png 
  1917   Mon Aug 17 04:16:13 2009 YoichiUpdatePSLReference cavity reflection looks bad[quote]Rana, Yoichi
- We also moved the Refcav reflection camera
to look at the leakage through a reflection
  
  1136   Fri Nov 14 19:20:42 2008 YoichiUpdatePSLReference cavity ring downThanks to Bob making the high-voltage BNC
cables for the HV pulse generator, I was
able to operate the EOM in front of
 RingDown.png 
  1137   Fri Nov 14 20:35:47 2008 ranaUpdatePSLReference cavity ring downTo make the DEI pulser make a fast pulse on
the EO shutter EOMs, we had to make sure:
  
  1138   Fri Nov 14 22:40:51 2008 YoichiUpdatePSLReference cavity ring down[quote]
To make the DEI pulser make a fast pulse
on the EO shutter EOMs, we had to make sure:
  
  1140   Mon Nov 17 15:07:06 2008 YoichiUpdatePSLReference cavity ring downI used MATLAB's system identification tool
box to estimate the response of the reference
cavity, i.e. cavity pole.
 Fit.png 
  1190   Fri Dec 12 22:51:23 2008 YoichiUpdatePSLReference cavity ring down measurement againBob made new HV-cables with HV compatible
coaxes. The coax cable is rated for 2kV,
which was as high as Bob
 RC-Ringdown.png 
  1191   Tue Dec 16 19:06:01 2008 YoichiUpdatePSLReference cavity ring down repeated many timesToday, I repeated the reference cavity ring
down measurement many times to see how much
the results vary.
 RC_Ringdown_Estimates.pngCavity_Pole_Histogram.png 
  2915   Wed May 12 02:35:13 2010 Koji, Rana, KiwamuUpdateGreen LockingReflection from ETM and ITM !We succeeded in getting
the reflected green beam from both ITMY and
  
  2917   Wed May 12 03:52:54 2010 KojiUpdateGreen LockingReflection from ETM and ITM !I could not understand this operation.
Can you explain this a bit more?
It sounds different from the standard
  
  2919   Wed May 12 09:16:29 2010 steveUpdateGreen LockingReflection from ETM and ITM ! 
 Now I know why Rana was wearing
his bright green pants yesterday. It is nice
  
  2930   Fri May 14 08:18:46 2010 steveUpdateGreen LockingReflection from ETM and ITM !I stopped AWG  1 Hz drive to ITMYs.
ITMXe was also driven or oscillating. ITMXe
damping was off, so I turned it on. It did
 itmx1hzos.jpg 
  476   Wed May 14 13:14:19 2008 AndreySummaryComputersReflective Memory Network is restored
[COLOR=blue]Reflective Memory Network is
restored, all watchdogs and oplevs are returned
  
  2362   Mon Dec 7 19:02:22 2009 MottUpdateGeneralReflectivity Measurements I have made some measurements of the R
value for some coatings we are interested
in.  The plots have statistical error
 Y1-45P_R.pngY1-45S_R.pngY1-50CC_R.png 
  1520   Sat Apr 25 00:45:31 2009 YoichiConfigurationVACReflector for the cryopump temperature monitor changedThe temperature of the cryopump head is monitored
by a photo switch looking at an aluminum
foil reflector attached to the needle of
  
  1521   Sat Apr 25 02:54:25 2009 YoichiConfigurationVACReflector for the cryopump temperature monitor changed[quote]The temperature of the cryopump head
is monitored by a photo switch looking at
an aluminum foil reflector attached to the
  
  300   Wed Feb 6 16:50:47 2008 josephbConfigurationCamerasRegions of Interest and max frame rateThe Snap code has once again been modified
such that setting the -l option to 0 will
take images as fast as possible.  Also, the
  
  301   Wed Feb 6 19:39:11 2008 ranaConfigurationCamerasRegions of Interest and max frame rateWe really need to look into making the 40m
CDS network have an all GigE backbone so
that we can have cooler cameras as well as
  
  5090   Tue Aug 2 10:53:03 2011 JenneOmnistructureSAFETYRegular door out of service. Use Control Room Door only!!The hazardous waste people are moving chemicals
around outside our door, and have roped off
our regular front door. 
  
  11214   Fri Apr 10 17:05:45 2015 ericqUpdateLSCRelative ETM calibration (Rough MC2 calibration)I did a quick measurement get an idea of
the ETM actuator calibration, relative
to the ITMs. This will still hold if/when
 quickCal.png 
  11215   Fri Apr 10 18:39:39 2015 ericqUpdateLSCRelative ETM calibration (Rough MC2 calibration)I didn't verify that the loop gain
was low enough at the excitation frequencies.
 betterCal.png 
  15326   Tue May 12 18:16:17 2020 gautamUpdateLSCRelative importance of losses in the arm and PRCAttachment
#1 is meant to show
 armLossVSPRCloss.pdf 
  15327   Tue May 12 20:16:31 2020 KojiUpdateLSCRelative importance of losses in the arm and PRCIs \eta_A the roundtrip loss for an arm?

Thinking about the PRG=10 you saw:
- What's the current PR2/3 AR?
  
  15328   Tue May 12 22:47:49 2020 gautamUpdateLSCRelative importance of losses in the arm and PRCYes, \eta_A is the (average) round-trip
loss for an arm cavity. I'd estimate
this is ~100ppm currently. I edited the original
  
  10848   Tue Dec 30 17:26:23 2014 ranaUpdatePSLRelaxation Osc and the NPRO Noise eaterI wonder if the variable bump around 100
kHz can be something about the NPRO and if
the bump we see is the closed loop response
 NE_Mephisto.png 
  11141   Fri Mar 13 23:49:28 2015 ranaUpdatePSLRelaxation Osc and the NPRO Noise eaterAnother thought about the mystery PCDRIVE
noise: we've been thinking that it could
be some slow death inside the NPRO, but it
  
  13952   Wed Jun 13 01:02:40 2018 gautamUpdateLSCReliable and repeatable 1f DRMI locking[koji,
gautam]

With Koji's help, I got repeatable
  
  13966   Thu Jun 14 18:09:24 2018 gautamUpdateLSCReliable and repeatable 1f DRMI lockingI finally analyzed the sensing measurement
I ran on Tuesday evening. Sensing responses
for the DRMI DOFs seems consistent with what
 DRMI1f_June14.pdf 
  17202   Thu Oct 20 19:47:24 2022 TegaUpdateCDSRelocate front-ends to Rack 1X7We mounted chiara, all front-end machines
and switches in rack 1x7; reconnected power,
dolphin, onestop and timing cables; and restarted
 IMG_20221020_193623269.jpgIMG_20221020_193637034.jpgiop_status_20221020.pngiop_status_20221020_restart_models.pngc1ioo_shm_glitch.png 
  16838   Mon May 9 18:49:05 2022 TegaUpdateBHDRelocate green TRX and TRY PDs/cams/optics from PSL table to BS table[Paco, Tega]

Started work on the relocating
the green transmission optics, cameras and
 IMG_20220509_184439943.jpgIMG_20220509_184154722.jpg 
  16842   Tue May 10 15:46:38 2022 JCUpdateBHDRelocate green TRX and TRY components from PSL table to BS table[JC, Tega]

Tega and I cleaned up the BS OPLEV
Table and took out a couple of mirrors and
 IMG_0741.jpegIMG_0753.jpeg 
  12114   Tue May 10 03:44:59 2016 ericqUpdateLSCRelockedALSX noise is solidly within past acceptable
performance levels. The DRFPMI was locked
on four out of six attempts. 
 2016-05-10_DARMcoherence.pdf 
  5271   Fri Aug 19 19:08:40 2011 JennyUpdatePSLRelocking NPRO to reference cavity. I am trying again to measure a temperature
step response on the reference cavity on
the PSL table.
  
  5272   Fri Aug 19 23:41:20 2011 JennyUpdatePSLRelocking NPRO to reference cavity.

    

       
            
  
  5468   Mon Sep 19 20:56:36 2011 PaulSummarySUSRemaining SRM and ITMY OSEMs calibrations 
I've now taken data for the pitch
and yaw calibrations for the OSEMs of SRM
 SRM_PITCH_calib_curve.pngSRM_YAW_calib_curve.pngITMY_PITCH_calib_curve.pngITMY_YAW_calib_curve.png 
  16519   Fri Dec 17 12:32:35 2021 KojiUpdateSUSRemaining task for 2021Anything else? Feel free to edit this entry.

- SUS: AS1 hanging

- SUS: PR3/SR2/LO2 3/4" thick
  