  10494   Thu Sep 11 02:08:32 2014 JenneUpdateLSCHigher transmission powersNo breakthroughs tonight. 
DRMI didn't want to lock with either
the recipe that we used a year ago (elog
 Zoom_TRXTRYat7_CARMsqrtInvTrans_DARMalsdiff.pngALSonly_TryingTransitionStraightToREFLDC.png 
  10497   Fri Sep 12 00:28:04 2014 ericqUpdateLSCHoly sensitivity, Batman!I took a quick measurement of the ALS stability,
using POX and POY as out of loop sensors,
using a CARM calibration line to line POX
 ALSoutOfLoop.pdf 
  10498   Fri Sep 12 00:40:23 2014 JenneUpdateLSCDRMI locking Tonight I worked on DRMI locking.
 
I think the reason the May2014 DRMI
  
  10499   Fri Sep 12 03:49:57 2014 ericqUpdateLSCSome more PRFPMI efforts Since DRMI didn't get fully commissioned,
I tried my hand at PRFPMI locking with the
newly improved ALS performance. 
  
  10500   Fri Sep 12 11:25:42 2014 KojiUpdateLSCDRMI lockingThis is great.
And I got confused. Is REFL11 going
through the CM board? 
  
  10501   Fri Sep 12 12:00:59 2014 ericqUpdateLSCDRMI lockingREFL11 I, as seen in digital land, is connected
to the slow output of the CM board. I tuned
the demod angle of the REFL11 demodulator
  
  10502   Fri Sep 12 14:11:17 2014 ericqUpdateLSCDRMI lockingWe
need to get an interferometric estimation
of the SRC length error / SRC sideband splitting,
 7x 
  10512   Wed Sep 17 01:40:55 2014 JenneUpdateLSCCloser to REFL DC? Maybe?I tried a bunch of times to reduce my CARM
offset so I could jump to REFLDC digitally,
but I think I'm maybe being a little ambitious
 Zoom_TRXTRYupto25_1094967592.png 
  10514   Wed Sep 17 15:40:00 2014 ericqUpdateLSCDRMI lockingI have not had any success the past two
days in getting an interferometric measurement
of the SRC length. 
 dcAngleDiff_srcL.pdfdrfpmiVertexSensing.zip 
  10516   Thu Sep 18 02:42:28 2014 JenneUpdateLSCAO path partly engagedTonight was a night of trying to engage
the AO path.  The idea was to sit at
arm powers of a few on sqrtInvTrans for CARM
 Zoom_TRXTRY4_EngagingAO_1095059162.png0020.pdf 
  10519   Thu Sep 18 17:44:55 2014 JenneUpdateLSCOld AO cable pulled[Q, Jenne]
We pulled the old 2-pin lemo cable
after I had a look at the connectors. 
  
  10520   Fri Sep 19 04:05:05 2014 ericqUpdateLSCAO path partly engagedMore AO efforts. No huge news. 
Came at AO from each side. For each
sign, I lost lock just a few dB from the
 TFSR785_19-09-2014_020555.pdfTFSR785_19-09-2014_033920.pdf 
  10521   Fri Sep 19 13:12:07 2014 JenneUpdateLSCAO path glitches

    

       
            
  
  10527   Tue Sep 23 17:37:10 2014 ericqUpdateLSCDRMI lockingRather than using a CAD drawing, I used
Gabriele's code from ELOG
 9590 to try and judge if we could
 SRCcorrection.pdf 
  10531   Wed Sep 24 11:02:38 2014 manasaUpdateLSCMoving SRMI looked at the CAD layout and it seems
like we will clearly
  
  10538   Thu Sep 25 11:33:41 2014 JenneUpdateLSCPOY alignment laser

    

       
            
  
  10554   Tue Sep 30 17:26:18 2014 ericqUpdateLSCNew AO cable in placeI've installed a new 2pin lemo cable going
from the CM servo out to in2 of the MC servo
board, and removed the temporary BNC. I used
  
  10558   Wed Oct 1 19:40:46 2014 ericqUpdateLSCArms IR alignedSummary:

    Beamsplitter
was put into MC refl path.
    HWP
was rotated to maximize power into PMC. 
  
  10562   Fri Oct 3 03:02:17 2014 ericqUpdateLSCNo luck locking DRMII haven't been able to lock the DRMI tonight,
neither with 1F and no arms nor 3F and arms
held off with ALS... I tried previous recipes,
  
  10574   Tue Oct 7 00:18:12 2014 JenneUpdateLSCYgreen PSL alignment, ETMX strain reliefNo exciting progress today.  I did
PSL green alignment for the Yarm, although
I now think that the Xarm green needs realigning
  
  10580   Tue Oct 7 19:40:58 2014 ericqUpdateLSCCM, REFL11 WiringI've changed the LSC rack wiring a little
bit, to give us some flexibility when it
comes to REFL11. 
  
  10581   Wed Oct 8 03:20:46 2014 JenneUpdateLSCDo we need AO for acquisition?As part of trying to determine whether
we require the AO path for lock acquisition,
or if we can survive on just digital loops,
 EstimatedNoisePerformance.pngBodeLSCvsALS.pngCARMnoise_7Oct2014.zip 
  10582   Wed Oct 8 03:37:44 2014 ericqUpdateLSCPRFPMI, other sign of CARM offset [ericq, Jenne]
We attempted some of the same old
CARM offset reduction tonight, but from the
  
  10583   Wed Oct 8 03:49:42 2014 JenneUpdateLSCPRFPMI, other sign of CARM offsetOther thoughts from talking with Rana earlier:

    Is it possible to suppress
CARM motion enough that we can use just a
  
  10589   Thu Oct 9 16:31:53 2014 ericqUpdateLSCCARM W/N TFsIn my previous simulation results, I've
always plotted W/m, which isn't exactly straightforward.
We often think about the displacement that
 carm2SQRTinv.pdfcarm2REFLDC.pdf 
  10591   Thu Oct 9 18:30:59 2014 JenneUpdateLSCCARM W/N TFsOkay, here (finally) is the optickle version.
I have the antispring case, starting
at 501pm and going roughly every 10pm down
 6x 
  10593   Fri Oct 10 00:20:37 2014 ranaUpdateLSCCARM W/N TFs 
 Assuming that these Watts/Newtons
TFs are correct, I've modeled the resulting
 carm40.pngcarm.pdf 
  10594   Fri Oct 10 03:05:09 2014 ericqUpdateLSCWhich side of optical spring are we on? I made some measurements to try and
see if any difference could be seen with
different CARM offset signs. 
 comparison.pdf 
  10595   Fri Oct 10 03:25:11 2014 JenneUpdateLSCWhich side of optical spring are we on (simulation)I have a simulated version of the differences
that we expect to see between the 2 different
sides of the CARM resonance.  The point
 10x 
  10598   Mon Oct 13 12:01:28 2014 ericqUpdateLSCWhich side of optical spring are we on? I went back into the DQ channels
to look at the TF from AO injection to REFLDC
(which is easy to do with this kind of noise
 AOInjection_SqrtInv_REFLDC.pngAOinjection_SqrtInv_REFLDC.xml.zip 
  10603   Mon Oct 13 21:20:56 2014 JenneUpdateLSCWhich side of optical spring are we on? (No progress)[Jenne, Diego]
In order to distinguish between the
spring and antispring sides of the CARM resonance,
  
  10607   Wed Oct 15 02:58:03 2014 JenneUpdateLSCWhich side of optical spring are we on? Some measurements.  Unclear meaning.
 
We tried both positive and negative
 PRFPMI_MC2injection_PosCARMoffset_REFLDC_TRX_response_14Oct2014_TRX.pdfPRFPMI_MC2injection_PosCARMoffset_REFLDC_TRX_response_14Oct2014_REFLDC.pdfPRFPMI_MC2injection_NegCARMoffset_REFLDC_TRX_response_14Oct2014_TRX.pdfPRFPMI_MC2injection_NegCARMoffset_REFLDC_TRX_response_14Oct2014_REFLDC.pdf 
  10608   Wed Oct 15 02:59:04 2014 ranaUpdateLSCCARM W/N TFs In my previous elog in this thread,
I showed the CARM OLG given some new digital
filters and the varying CARM plant (spring
 spring.pdfantispring.pdf 
  10609   Wed Oct 15 13:38:33 2014 JenneUpdateLSCCARM W/N TFsHere are the same plots, but the legend
also includes the arm power that we expect
at that CARM offset.  
 7x 
  10612   Wed Oct 15 19:56:38 2014 JenneUpdateLSCWhich side of optical spring are we on? Meas vs Model I have plotted measured data from
last night (elog
10607) with a version of the result from
 AntispringModel_NegOffsetMeas_comparison.pdfSpringModel_NegOffsetMeas_comparison.pdf 
  10613   Wed Oct 15 20:10:29 2014 ericqUpdateLSCInterim DARM SignalI've done
some preliminary modeling to see if there
is a good candidate for an 
 7x 
  10614   Wed Oct 15 22:39:17 2014 JenneUpdateLSCThe Plan [Rana, Jenne]
We're summarizing the discussions
of the last few days as to the game plan
  
  10615   Thu Oct 16 03:13:23 2014 JenneUpdateLSCPRMI on REFL165, and more The first thing I looked at tonight
was locking the PRMI on REFL 165.
I locked the PRMI (no arms), and
  
  10618   Thu Oct 16 16:21:42 2014 ericqUpdateLSCInterim DARM SignalI've added
(TRX-TRY)/(TRX+TRY) to the DC DARM sweep
plots, and it looks like an even better candidate.
 dcDARMSweep-300.pdfdcDARMSweep-120.pdfdcDARMSweep-50.pdfdcDARMSweep-0.pdf 
  10619   Thu Oct 16 21:20:59 2014 ranaUpdateLSCmisleading modelling I think these are all very helpful
and interesting plots. We should see some
better performance using either of the DC
  
  10620   Thu Oct 16 22:35:05 2014 ranaUpdateLSCCARM W/N TFsIn my last CARM loop modelling, all of
the plots are phony, so don't trust them.
The invbilinear function inside of StefanB's
 carm_spring.pdfcarm_antispring.pdf 
  10621   Fri Oct 17 03:05:00 2014 ericqUpdateLSCDARM locked on DC Transmission difference I've
been able to repeatedly get off of ALS and
onto (TRY-TRX)/(TRY+TRX). Nevertheless, lock
 TRdifflock.pngOct17lock.pdf 
  10622   Fri Oct 17 13:19:48 2014 JenneUpdateLSCPOP22 ?!?!We've seen this before, but we need to
figure out why POP22 decreases with decreased
CARM offset.  If it's just a demod phase
  
  10625   Fri Oct 17 17:52:55 2014 JenneUpdateLSCRAM offsetsLast
night I measured our RAM offsets and looked
at how those affect the PRMI situation. 
 16x 
  10626   Mon Oct 20 17:50:30 2014 JenneUpdateLSCCARM W/N TFs (Others were all wrong!)I realized today that I had been plotting
the wrong thing for all of my transfer functions
for the last few weeks! 
 7x 
  10627   Tue Oct 21 00:38:40 2014 ericqUpdateLSCsweep + RMS as uncertainty

    

       
            
 dcCARMSweep_uncertainties.png 
  10630   Wed Oct 22 02:35:45 2014 JenneUpdateLSCEfforts at hopping PRMI to REFL165[EricQ, Jenne]
The first half of our evening
was spent working on CARM and DARM in PRFPMI,
  
  10631   Wed Oct 22 06:32:29 2014 ranaUpdateLSCsweep + RMS as uncertainty 
 This is looking very useful.
It will be useful if you can upload some
  
  10634   Thu Oct 23 02:08:40 2014 JenneUpdateLSCIncreased DARM gainI changed the carm_cm_up.sh script so
that it requires fewer human interventions. 
Rather than stopping and asking for things
 6x 
  10637   Fri Oct 24 02:14:05 2014 JenneUpdateLSCIncreased DARM gain even more[Jenne, Diego]
We spent the afternoon working on
the new scan for IR resonance script. 
 DARM_23Oct2014.pdf 
ELOG V3.1.3-