40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 213 of 344  Not logged in ELOG logo
Entry  Wed Jul 2 21:30:42 2014, Jenne, Update, LSC, Little Bo-Peep has lost her phase CARM_loop_ArmPowers1_2July2014.pdf
    Reply  Wed Jul 2 22:58:11 2014, Jenne, Update, LSC, Little Bo-Peep has found her phase 
Entry  Mon Jul 7 13:55:26 2014, Jenne, Update, LSC, c1cal model restarted 
Entry  Thu Jul 10 02:15:36 2014, Jenne, Update, LSC, QPD dark noise checkout 
    Reply  Fri Jul 11 20:05:34 2014, Jenne, Update, LSC, QPD dark noise checkout TransQPDY_darkNoise_vs_TransimpedanceGain_9July2014.pdfTransQPDY_darkNoise_vs_WhiteningGain_9July2014.pdfsqrtTrans_sensitivity.pngsqrtTrans_Noise_vs_CARMoffset.png
Entry  Tue Jul 15 01:41:43 2014, Jenne, Update, LSC, Data for DARM on sqrtInv investigation 
    Reply  Tue Jul 15 21:43:28 2014, Jenne, Update, LSC, QPDs back 
    Reply  Wed Jul 16 01:04:09 2014, Jenne, Update, LSC, Data for DARM on sqrtInv investigation 
Entry  Wed Jul 16 01:18:02 2014, rana, Summary, LSC, Python Wavelet peak finding for dramatic ALS - Red Resonance finding speedup findRedResonance.pdf
    Reply  Wed Jul 16 01:35:16 2014, Koji, Summary, LSC, Python Wavelet peak finding for dramatic ALS - Red Resonance finding speedup 
Entry  Thu Jul 17 00:38:30 2014, Jenne, Update, LSC, RIN in arm transmission TransRIN.pdf
    Reply  Sat Jul 19 17:36:44 2014, Jenne, Update, LSC, RIN in arm transmission TransSqrtInvRIN_vs_ALSsensing_18July2014.pngThorlabsRIN_16July2014.png
    Reply  Sat Jul 19 20:51:51 2014, Koji, Update, LSC, RIN in arm transmission 
    Reply  Mon Jul 21 17:32:43 2014, ericq, Summary, LSC, Arm losses 
    Reply  Wed Jul 23 02:01:15 2014, Jenne, Update, LSC, RIN in arm transmission - revised calibration TransSqrtInvRIN_vs_ALSsensing_18July2014.png
Entry  Wed Jul 23 11:32:04 2014, Koji, Update, LSC, IFO warming up 140722_ALS.pdf
Entry  Wed Jul 23 23:43:28 2014, ericq, Update, LSC, Locking efforts; Wrath of the Mode Cleaner 
    Reply  Tue Jul 29 16:41:54 2014, Koji, Update, LSC, MC servo MCservo.pdf
Entry  Tue Jul 29 18:00:20 2014, Akhil, Update, LSC, Calibration of ETMX and ETMY actuators PZT_ETMX_TF.pngPZT_ETMY_TF.pngPZT_ITMX_TF.pngPZT_ITMY_TF.png
    Reply  Wed Jul 30 00:42:27 2014, Koji, Update, LSC, MC servo MCservo.pdf
    Reply  Wed Jul 30 22:01:24 2014, Koji, Update, LSC, MC servo 
Entry  Thu Jul 31 01:08:54 2014, Koji, Update, LSC, ALS stability check postXGreenUpgradeCheckup.pdf
Entry  Mon Aug 4 22:52:03 2014, Jenne, Update, LSC, ALS alignment tweak-up 
Entry  Wed Aug 6 00:14:10 2014, Jenne, Update, LSC, ALS is iffy tonight 
    Reply  Thu Aug 7 12:34:56 2014, Jenne, Update, LSC, Suspensions not kicking? 
Entry  Wed Aug 13 19:23:09 2014, Jenne, Update, LSC, PSL, Aux laser mode hop check ModeHopCheck_PSL_13Aug2014.pdfModeHopCheck_Xend_13Aug2014.pdfModeHopCheck_Yend_13Aug2014.pdf
Entry  Thu Aug 14 18:31:45 2014, ericq, Update, LSC, LSC Modeling Update 7x
Entry  Thu Aug 14 22:31:12 2014, Jenne, Update, LSC, TRY gets mystery offset TRY_0pt3_offset.pdf
Entry  Thu Aug 14 23:19:49 2014, rana, Summary, LSC, ETM Violin fundamental filters moved to LSC 01.png03.png
Entry  Fri Aug 15 02:05:55 2014, Jenne, Update, LSC, ALS in-loop spectra ALS_XY_inloop_noise_14Aug2014_lowBeatFreq.pdf
    Reply  Fri Aug 15 14:09:21 2014, Jenne, Update, LSC, TRY mystery offset gone TRY_0pt3_offset_gone.pdf
    Reply  Fri Aug 15 14:35:57 2014, ericq, Update, LSC, TRY mystery offset gone TRYmystery.png
Entry  Fri Aug 22 03:55:45 2014, Jenne, Update, LSC, Xarm PDH fine, Yarm PDH/ALS needs work Xend_ErrorPointMeasurements.pdfDARM_ALSdiff_vs_sqrtInv.pdf
Entry  Thu Aug 28 01:41:03 2014, ericq, Update, LSC, Phase Tracker UGF normalization UGFnorm.png
Entry  Tue Sep 2 22:54:27 2014, Koji, Summary, LSC, phase tracker UGF 
Entry  Wed Sep 3 04:17:21 2014, Jenne, Update, LSC, Y green ALS (not PDH) needs investigation Yarm_noisy_above_20Hz.pdf
Entry  Wed Sep 3 18:42:43 2014, Jenne, Update, LSC, Green PDH box boosts BoostCartoon.pdf
    Reply  Thu Sep 4 00:56:44 2014, Jenne, Update, LSC, Green PDH box boosts TFstage_newDesign_3Sept2014.pngBoostNoBoost_newDesign_3Sept2014.pngBoostOnly_newDesign_3Sept2014.pngD0901351-v1_3Sept2014.pdf
Entry  Thu Sep 4 01:28:32 2014, ericq, Update, LSC, Recycling cavity lengths 
    Reply  Thu Sep 4 03:12:55 2014, ericq, Update, LSC, Green PDH box boosts boostedTF.pdfgain.jpg
    Reply  Thu Sep 4 10:10:23 2014, Koji, Update, LSC, Recycling cavity lengths 
    Reply  Thu Sep 4 16:45:10 2014, Jenne, Update, LSC, Green PDH box boosts IMG_1712.JPGIMG_1714.JPG
    Reply  Thu Sep 4 18:16:20 2014, ericq, Update, LSC, Recycling cavity lengths 2014-09-CavityLengths.zip
    Reply  Fri Sep 5 05:32:57 2014, Jenne, Update, LSC, Green PDH box boosts TRX_TRY_ALSvsIR_4Sept2014.pdf
    Reply  Fri Sep 5 21:13:57 2014, Jenne, Update, LSC, Green PDH out of loop ALS_XY_outOfLoop_5Sept2014.pdf
Entry  Tue Sep 9 00:34:34 2014, Jenne, Update, LSC, Figuring out where to do DARM->AS55 
    Reply  Tue Sep 9 14:25:46 2014, jamie, Update, LSC, Figuring out where to do DARM->AS55 
Entry  Wed Sep 10 02:26:20 2014, Jenne, Update, LSC, DARM -> AS55 optickle AS55Q_vs_DARM_PRFPMI_0pm300pm.pngAS55I_vs_DARM_PRFPMI_0pm300pm.pngAS55Q_vs_DARM_DRFPMI_0pm300pm.pngAS55I_vs_DARM_DRFPMI_0pm300pm.pngAS55Q_vs_DARM_DRFPMI_0pm1000pm.png
Entry  Wed Sep 10 02:53:32 2014, Jenne, Update, LSC, Locking activities - nothing new :( LocklossZoom.png
    Reply  Wed Sep 10 02:59:42 2014, ericq, Update, LSC, Locking activities - nothing new :( 
ELOG V3.1.3-