  10563   Fri Oct 3 10:10:37 2014 SteveUpdateVACcold cathode gauge reading switched 
We have two cold cathode gauges at
the pump spool and one  signal cable
 CC1switched.png 
  10564   Fri Oct 3 13:03:05 2014 ericqUpdateIOOIMC WFS measurementsYesterday, Koji and I measured the transfer
function of pitch and yaw excitations of
each MC mirror, directly to each quadrant
 WFS1PIT.pdfWFS2PIT.pdfWFS1YAW.pdfWFS2YAW.pdfanalyzeWfs.zip 
  10565   Sun Oct 5 10:09:49 2014 ranaUpdateIOOIMC WFS measurementsIt seems clever, but I wonder
why use DTT and command line perl, instead
of using the FE lockins or just demod the
  
  10566   Sun Oct 5 23:43:08 2014 KojiUpdateIOOIMC WFS measurementsThere are several non scientific reasons.   
  10567   Mon Oct 6 10:04:58 2014 manasaUpdateGeneralUnexpected power shutdownWe had a unexpected    
  10568   Mon Oct 6 10:23:43 2014 SteveUpdateVACUnexpected power shutdown

    

       
            
  
  10569   Mon Oct 6 10:28:18 2014 manasaUpdateGeneralUnexpected power shutdown

    

       
            
  
  10570   Mon Oct 6 11:09:52 2014 JenneUpdateGeneralUnexpected power shutdown: slow computersAs per other slow computers, which Chris
figured out in elog
10189, I added all the rest of the slow
  
  10571   Mon Oct 6 17:04:51 2014 ericqUpdateGeneralUnexpected power shutdownI brought back the PMC, MC and Arms.
PMC:

    Same as when we replaced
  
  10572   Mon Oct 6 17:36:17 2014 ericqUpdateGeneralUnexpected power shutdownThe autolocker is now working, but I didn't
change anything to make it so. I was just
putting in some echo statements, to see where
  
  10573   Mon Oct 6 18:15:12 2014 manasaUpdateGeneralUnexpected power shutdown: end green alignmentAfter Q brought back the IR, I went to
check the green situation.
1. The end lasers had to be turned
  
  10574   Tue Oct 7 00:18:12 2014 JenneUpdateLSCYgreen PSL alignment, ETMX strain reliefNo exciting progress today.  I did
PSL green alignment for the Yarm, although
I now think that the Xarm green needs realigning
  
  10575   Tue Oct 7 10:09:07 2014 manasaUpdateGeneralChiara not respondingChiara  doesn't seem to be responding and
I guess something happened 7 hrs ago.
I tried to hook up chiara to a monitor
  
  10576   Tue Oct 7 16:17:15 2014 SteveUpdateGeneralreason for 8 sec power outage

    

       
            
  
  10577   Tue Oct 7 16:19:50 2014 ericqUpdateGeneralChiara not respondingWe're back! It   
  10578   Tue Oct 7 16:41:12 2014 JenneUpdateGeneralChiara not respondingI put a little script into ...../scripts/Admin
that will check the fullness of Chiara's
disk.  We only have the mailx program
  
  10579   Tue Oct 7 16:55:16 2014 SteveUpdateVACUnexpected sweaty valves Pump  spool valves V5, V4, V3
sweating a lot. VM3 and VC2 not so much.
 sweatyV5.jpgsweatyV5f.jpg 
  10580   Tue Oct 7 19:40:58 2014 ericqUpdateLSCCM, REFL11 WiringI've changed the LSC rack wiring a little
bit, to give us some flexibility when it
comes to REFL11. 
  
  10581   Wed Oct 8 03:20:46 2014 JenneUpdateLSCDo we need AO for acquisition?As part of trying to determine whether
we require the AO path for lock acquisition,
or if we can survive on just digital loops,
 EstimatedNoisePerformance.pngBodeLSCvsALS.pngCARMnoise_7Oct2014.zip 
  10582   Wed Oct 8 03:37:44 2014 ericqUpdateLSCPRFPMI, other sign of CARM offset [ericq, Jenne]
We attempted some of the same old
CARM offset reduction tonight, but from the
  
  10583   Wed Oct 8 03:49:42 2014 JenneUpdateLSCPRFPMI, other sign of CARM offsetOther thoughts from talking with Rana earlier:

    Is it possible to suppress
CARM motion enough that we can use just a
  
  10584   Wed Oct 8 08:46:57 2014 SteveUpdateVACVAT valves actuator lubricant

    

       
            
  
  10585   Wed Oct 8 15:31:31 2014 JenneUpdateCDSComputer statusAfter the Great Computer Meltdown of 2014,
we forgot about poor c0rga, which is why
the RGA hasn't been recording scans for the
  
  10586   Thu Oct 9 10:52:37 2014 manasaUpdateGeneralPower outage II & recoveryPost 30-40min unexpected power outage this
morning, Steve checked the status of the
vacuum and I powered up Chiara.
  
  10587   Thu Oct 9 11:56:35 2014 SteveUpdateVACPower outage II & recovery

    

       
            
  
  10588   Thu Oct 9 13:29:14 2014 JenneUpdatePSLPower outage II & recovery

    

       
            
  
  10589   Thu Oct 9 16:31:53 2014 ericqUpdateLSCCARM W/N TFsIn my previous simulation results, I've
always plotted W/m, which isn't exactly straightforward.
We often think about the displacement that
 carm2SQRTinv.pdfcarm2REFLDC.pdf 
  10590   Thu Oct 9 17:33:28 2014 SteveUpdateVACPower outage II & recovery

    

       
            
 pumpingAgain.png 
  10591   Thu Oct 9 18:30:59 2014 JenneUpdateLSCCARM W/N TFsOkay, here (finally) is the optickle version.
I have the antispring case, starting
at 501pm and going roughly every 10pm down
 6x 
  10592   Thu Oct 9 19:14:04 2014 ericqUpdateGeneralPower outage II & recoveryI touched up the PMC alignment. 
While bringing back the MC, I realized
IOO got a really old BURT restore again...
  
  10593   Fri Oct 10 00:20:37 2014 ranaUpdateLSCCARM W/N TFs 
 Assuming that these Watts/Newtons
TFs are correct, I've modeled the resulting
 carm40.pngcarm.pdf 
  10594   Fri Oct 10 03:05:09 2014 ericqUpdateLSCWhich side of optical spring are we on? I made some measurements to try and
see if any difference could be seen with
different CARM offset signs. 
 comparison.pdf 
  10595   Fri Oct 10 03:25:11 2014 JenneUpdateLSCWhich side of optical spring are we on (simulation)I have a simulated version of the differences
that we expect to see between the 2 different
sides of the CARM resonance.  The point
 10x 
  10596   Fri Oct 10 14:27:44 2014 SteveUpdateCDSc1Vac1 and c1vac2 reboot was a failure

    

       
            
 c1vac1resetReboot.pngc1Vac1&2down.jpg 
  10597   Fri Oct 10 14:41:04 2014 SteveUpdateVACPower outage II & recovery

    

       
            
 recovery_poweroutage.png 
  10598   Mon Oct 13 12:01:28 2014 ericqUpdateLSCWhich side of optical spring are we on? I went back into the DQ channels
to look at the TF from AO injection to REFLDC
(which is easy to do with this kind of noise
 AOInjection_SqrtInv_REFLDC.pngAOinjection_SqrtInv_REFLDC.xml.zip 
  10599   Mon Oct 13 14:44:52 2014 SteveUpdateVACRGA scan pd78 -day 13 Our first RGA scan since May 27,
2014 elog10585
 The Rga is still warming up.
 RGAscan13Oct2014.png 
  10600   Mon Oct 13 16:08:49 2014 JenneUpdateCDSFrame builder is madI think the daqd process isn't running
on the frame builder. 
 Daqd_problem_maybe.png 
  10601   Mon Oct 13 16:57:26 2014 KojiUpdateCDSFrame builder is madCPU load seems extremely high. You need
to reboot it, I think
controls@fb /proc 0$ cat loadavg
  
  10602   Mon Oct 13 17:09:38 2014 ericqUpdateCDSFrame builder is mad 
This CPU load may have been me deleting
some old frame files, to see if that would
  
  10603   Mon Oct 13 21:20:56 2014 JenneUpdateLSCWhich side of optical spring are we on? (No progress)[Jenne, Diego]
In order to distinguish between the
spring and antispring sides of the CARM resonance,
  
  10604   Mon Oct 13 21:59:47 2014 ranaUpdateComputer Scripts / ProgramsWhich side of optical spring are we on? (No progress) 
 Since no one was here, I started
the Ubuntu 10 - 12 upgrade on Rossa. It didn't
  
  10605   Tue Oct 14 17:38:31 2014 ericqUpdateComputer Scripts / ProgramsRossa and Allegra wiped, Ubuntu 12.04 installedWhen I came in, Rossa was booted to Ubuntu
10. I tried rebooting to select 12, but couldn't
ever successfully boot again. Since Diego
  
  10606   Tue Oct 14 23:44:42 2014 diegoUpdateComputer Scripts / ProgramsRossa and Allegra wiped, Ubuntu 12.04 installedAllegra and Rossa wiped and updated to
Ubuntu 12.04.5 by me and Ericq; the following
procedure was followed:
  
  10607   Wed Oct 15 02:58:03 2014 JenneUpdateLSCWhich side of optical spring are we on? Some measurements.  Unclear meaning.
 
We tried both positive and negative
 PRFPMI_MC2injection_PosCARMoffset_REFLDC_TRX_response_14Oct2014_TRX.pdfPRFPMI_MC2injection_PosCARMoffset_REFLDC_TRX_response_14Oct2014_REFLDC.pdfPRFPMI_MC2injection_NegCARMoffset_REFLDC_TRX_response_14Oct2014_TRX.pdfPRFPMI_MC2injection_NegCARMoffset_REFLDC_TRX_response_14Oct2014_REFLDC.pdf 
  10608   Wed Oct 15 02:59:04 2014 ranaUpdateLSCCARM W/N TFs In my previous elog in this thread,
I showed the CARM OLG given some new digital
filters and the varying CARM plant (spring
 spring.pdfantispring.pdf 
  10609   Wed Oct 15 13:38:33 2014 JenneUpdateLSCCARM W/N TFsHere are the same plots, but the legend
also includes the arm power that we expect
at that CARM offset.  
 7x 
  10610   Wed Oct 15 17:09:49 2014 manasaUpdateGeneralDiode laser test preparation[EricG, manasa]
The He-Ne laser oplev setup was swapped
with a fiber-coupled diode laser from W Bridge.
  
  10611   Wed Oct 15 17:18:10 2014 JenneUpdateComputer Scripts / ProgramsDataviewer fix with Ubuntu 12.04 
 I have modified the Dataviewer
launcher (which runs when you either click
  
  10612   Wed Oct 15 19:56:38 2014 JenneUpdateLSCWhich side of optical spring are we on? Meas vs Model I have plotted measured data from
last night (elog
10607) with a version of the result from
 AntispringModel_NegOffsetMeas_comparison.pdfSpringModel_NegOffsetMeas_comparison.pdf 