40m QIL Cryo_Lab CTN SUS_Lab CAML OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 210 of 354  Not logged in ELOG logo
IDdown Date Author Type Category Subject Text Attachments
  7293   Tue Aug 28 09:37:33 2012 SteveUpdateVACRGA scan at day 56RGA scan,  Maglev pumping speed at
day 56
CC1 is dying. CC4 is real.
 pd72m56d.pngpd72m56dpr.png 
  7292   Tue Aug 28 00:23:54 2012 JenneUpdatePSLPMC alignment going badPMC transmission started going down this
afternoon, around 3pm-ish.  Right now
it's 0.775, which is very, very low. 
 PMC_transmission_GoingDown_27Aug2012.png 
  7291   Tue Aug 28 00:16:19 2012 jamieUpdateGeneralAlignment and vent prepI think we (Jenne, Jamie) are going to
leave things for the night to give ourselves
more time to prep for the vent tomorrow.
 as1.png 
  7290   Mon Aug 27 23:52:59 2012 JenneUpdateIOOMC Spots centeredFinally!
Jamie and I have the MC spots centered. 
We did the normal move the input beam, realign
 MCdecenter_26Aug2012.png 
  7289   Mon Aug 27 18:59:24 2012 jamieUpdateIOOMC ASC screen was confusing - Jenne is not stupid

    

       
            
 Screenshot-1.pngScreenshot-2.png 
  7288   Mon Aug 27 18:32:48 2012 JenneUpdateIOOMC spot position - Jenne is stupid

    

       
            
  
  7287   Mon Aug 27 17:14:00 2012 jamieUpdateCDSc1oaf problem

    

       
            
  
  7286   Mon Aug 27 15:49:46 2012 JenneUpdateSUSEQ damage

    

       
            
  
  7285   Mon Aug 27 15:46:55 2012 SteveUpdateSAFETYsafety training Rijuparna                 Chakraborty
and Elli Elenora King received 40m specific 
basic safety training in the 40mLab
 IMG_1597.JPG 
  7284   Mon Aug 27 12:03:54 2012 KojiUpdateIOOMC spot position - callin' it quitsThe MC REFL path was checked. ==> Some
clippings were fixed. MC WFS is working now.
- MC was aligned manually
  
  7283   Mon Aug 27 10:49:03 2012 KojiUpdateSUSEQ damageAfter shaking ITMX by the alignment bias
in yaw, it came back.
As ETMX seems to be largely misaligned
  
  7282   Mon Aug 27 09:24:17 2012 SteveUpdateSUSEQ damage  It looks like we may lost 1 (or
3 )  magnets? Do not panic, it's not
for sure
 eqDamage.png 
  7281   Mon Aug 27 08:34:18 2012 SteveUpdatePEMearthquakesShasky
day yesterday postpones venting. We had
about 11 shakes larger than mag 4.0 Mag5.5
 eq5.5Msaltonsea.pngM5.5inaction.pngEQeffect.png 
  7280   Mon Aug 27 01:05:36 2012 JenneUpdateIOOMC spot position - callin' it quitsspot positions in mm (MC1,2,3 pit MC1,2,3
yaw):
[-0.98675603448324423, -0.94064212026141558,
 MCdecenter_26Aug2012.png 
  7279   Sun Aug 26 21:47:50 2012 KojiUpdateCDSC1LSC oozeI came in to the lab in the evening and
found c1lsc had "red" for FB connection.
I restarted c1lsc models and it kept
  
  7278   Sun Aug 26 20:58:21 2012 JenneUpdateVACDon't vent!!!![Koji, Jenne]
Steve, do not vent tomorrow morning! 
We are still not prepared, and will not finish
  
  7277   Sun Aug 26 12:26:44 2012 JenneUpdateIOOMC spot position - not done yet

    

       
            
  
  7276   Sun Aug 26 11:53:09 2012 JenneUpdateIOOMC2 getting kicked up regularlyWe need to re-look at this new MC autolocker
stuff, and the new MCL filters.
MC2 is getting kicked up (sometimes
  
  7275   Fri Aug 24 22:01:15 2012 JenneUpdateIOOMC spot position - closeI am getting closer with the MC spot centering. 
I had everything but MC1 really great, but
then I tweaked MC1's pointing, and things
 MCdecenter_24Aug2012.png 
  7274   Fri Aug 24 21:00:40 2012 KojiUpdateLSCX end green investigationI checked and fixed the X end green situation.
Now
the X green beam is locked with TEM00.
  
  7273   Fri Aug 24 20:48:10 2012 KojiUpdatePSLPMC alignedas usual.   
  7272   Fri Aug 24 16:03:39 2012 SteveUpdateVACVacuum related work at atmVacuum related work at atmosphere:
Atm1,  Check all chamber dog
clamps tightness with torque wrench,
 IMG_1563.JPGIMG_1565.JPGIMG_1566.JPG 
  7271   Fri Aug 24 14:46:08 2012 JenneSummaryGeneralDetailed alignment planFriday / pre-vent:
[done]
Align the MC mirrors for the incident
  
  7270   Fri Aug 24 13:22:19 2012 DenUpdateModern Controlcavity simulationI did a simulation of a cavity, feedback
signal was calculated using LQG controller.
I assumed that there is not length ->
 model.pngcontroller.pngcavity_lqg.pngcavity.png 
  7269   Fri Aug 24 11:46:59 2012 MashaUpdatePEMNew classification weightsI recently realized that I may have over-trained
my classification neural network and used
too many parameters, so that my weight vectors
 current_learning_curve.png 
  7268   Fri Aug 24 09:21:45 2012 SteveUpdateIOOMC2 damping restored

    

       
            
 10hrsMC2.png 
  7267   Fri Aug 24 00:23:20 2012 DenUpdateModern Controlfeedback using LQG methodI did a simulation of linear quadratic
gaussian (LQG) controller applied to local
damping. The cost function was frequency
 model.pngfeedback_lqg.png 
  7266   Thu Aug 23 22:54:32 2012 JenneUpdateGreen LockingXgreen still wouldn't lock

    

       
            
 Xarm_Green_ErrorReflSignals_23Aug2012_LowRes.png 
  7265   Thu Aug 23 22:44:32 2012 KojiUpdatePSLFSS Slow DC servo is turned off (not temporary)[Koji Rana]
The FSS Slow DC servo was turned
off.
  
  7264   Thu Aug 23 22:41:04 2012 KojiUpdateIOOMC Autolocker update[Koji Rana]
MC Autolocker was updated. (i.e.
mcup and mcdown were updated)
  
  7263   Thu Aug 23 22:21:13 2012 ranaConfigurationIOOMCL turned back onI turned on some filters and gain in the
SUS-MC2_MCL filter bank tonight so as suppress
the seismic noise influence on MC_F. This
 mcl-screen.pngmcf-noise.pdf 
  7262   Thu Aug 23 21:53:18 2012 YaakovUpdatePEMAccelerometer locationThe MC1 accelerometer cube (3 accelerometers
arranged in x,y,z) is under the PSL table,
as I found it at the beginning of the summer.
  
  7261   Thu Aug 23 21:53:06 2012 JenneUpdateGreen LockingXgreen still wouldn't lock[Jenne, Jamie]
We took a look at the Xend green,
and we weren't able to make it lock. 
  
  7260   Thu Aug 23 17:51:25 2012 ManasaUpdate IMC Ringdown

    

       
            
  
  7259   Thu Aug 23 17:17:49 2012 MashaSummaryComputersCode Folder StatusI cleaned up my directory (/users/masha)
today. A lot of the files are just code that
I experimented with, but the important files
  
  7258   Thu Aug 23 15:42:48 2012 ranaUpdateSTACISSTACIS signal box made 
 I found this
entry in the old 40m ilog which
 vsanni-1107222997.pdf 
  7257   Thu Aug 23 15:35:33 2012 ranaUpdate IMC Ringdown 
 It is HIGHLY unlikely
that the IMC mirrors are having any effect
  
  7256   Thu Aug 23 12:17:39 2012 ManasaUpdate IMC RingdownThe ringdown measurements are in progress.
But it seems that the MC mirrors are getting
kicked everytime the cavity is unlocked by
 mozilla.pdfMC_sus.pdf 
  7255   Thu Aug 23 10:38:12 2012 SteveUpdateGeneralvent prepartion for fast-track vent

    

       
            
  
  7254   Thu Aug 23 10:08:13 2012 SteveUpdatePEMseismometers?

    

       
            
 bajaMag3.pngseisvssus.png 
  7253   Thu Aug 23 00:18:54 2012 JenneUpdatePEMWeird BLRMS increaseWhile I was gone for dinner break, the BLRMS
went back to normal.  Then, almost 2 hours
later, another peak appeared, this time closer
 BS_OSEMsensors_higherFreqPeakIsOlder_LowerFreqPeakIsMoreRecent.pdf 
  7252   Wed Aug 22 20:33:51 2012 DenUpdateAdaptive FilteringMC_L in ARMSJenne and I did adaptive filtering of MC_L
and measured how X and Y ARM control signals
change compared to non-filtered MC_L. We
 oaf_arms.png 
  7251   Wed Aug 22 18:58:12 2012 JenneUpdatePEMWeird BLRMS increaseIt seems as though there is something funny
going on around ~1.5 Hz, starting a little
over an hour ago.
 10x 
  7250   Wed Aug 22 16:50:09 2012 JenneUpdateLockingDouble integrator in ARM LSC servosLast week, Rana changed the integrators
in the arm LSC servo filters to be double
integrators with complex poles. 
 DoubleIntegrator_timeSeries_LowRes.pngDoubleIntegrator_Bode_vs_Ramp_LowRes.png 
  7249   Wed Aug 22 15:47:34 2012 jamieSummaryGeneralvent prepartion for fast-track ventWe are discussing venting first thing next
week, with the goal of
diagnosing what's going on in the
  
  7248   Wed Aug 22 11:41:20 2012 steveUpdateGeneralgrout plate for optical table at the endsReinforced concrete grout plate for existing
carbon steel stands at the ends.
 
 IMG_1561.JPG08231201.PDF 
  7247   Wed Aug 22 01:54:03 2012 JenneUpdateGeneralList o' things: YarmASS, ETMXTcamera, POXwhiteningTriggeringWhile meditating
on other things, I have noticed / found the
following today:
  
  7246   Tue Aug 21 22:54:47 2012 JenneUpdateLockingRemoved beam dump from POY pathPOY was looking funny, and the YARM wasn't
locking.  It looked like POY wasn't
seeing any light at all.  I went to
  
  7245   Tue Aug 21 18:23:58 2012 ManasaUpdate40m UpgradingETMX table layoutOptical layout of the current endtable
at ETMX has been updated in the svn repository
(directory: 40M_Optical Layout). This layout
  
  7244   Tue Aug 21 15:26:04 2012 SteveUpdatePEMtemp sensor for vacuumTemperature sensor for vacuum. How many
: 2 or 3 ?  $350 each
Glass encapsulated thermistor
  
ELOG V3.1.3-