40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 20 of 341  Not logged in ELOG logo
ID Date Author Type Categoryup Subject Text Attachments
  5871   Fri Nov 11 10:30:27 2011 ranaUpdateAdaptive FilteringMC_F 
 There should be a whitening
filter in the Pentek Generic DAQ board (Eurocard
  
  5879   Sat Nov 12 02:00:36 2011 MirkoUpdateAdaptive FilteringMC-F and other signalsRegarding http://nodus.ligo.caltech.edu:8080/40m/5867
and http://nodus.ligo.caltech.edu:8080/40m/5869
:
 Compare_signals_at_all_places.pngOAF-MCL-Delay-9Nov2011.pdfCompare_signals_at_all_places.figChannels_attached_to_the_PEM_ADC.pngChannels_attached_to_the_PEM_ADC.fig 
  5882   Sat Nov 12 02:46:13 2011 DenUpdateAdaptive Filteringstacks and groundWe measured the coherence between the seismometer
near the MC2 stack and accelerometers on
the vacuum tank where MC2 is. Because accelerometers
 ground_stack.jpgground_stack_coherence.jpg 
  5900   Tue Nov 15 22:31:39 2011 MirkoUpdateAdaptive FilteringTowards wiener filtering and improved OAFing
[Jenne, Mirko]
1. We should help the OAF by compensating
 7x 
  5919   Wed Nov 16 23:50:40 2011 DenUpdateAdaptive Filteringseismic noise injection[Micro, Den]
Analyzing coherence of seismic noise
and mode cleaner length we've figured out
 datespsd.jpgdatescoh.jpginjectionpsd.jpginjectioncoh.jpg 
  5932   Thu Nov 17 22:24:19 2011 DenUpdateAdaptive FilteringMC1_COILAnalyzing coherence between MC length and
signals on MC1, MC2 and MC3 coils we have
noticed that MC1 COIL signal is not coherent
 MC1COIL-crop.pdfMC2COIL-crop.pdfMC3COIL-crop.pdf 
  6065   Sat Dec 3 18:29:20 2011 DenUpdateAdaptive FilteringcoherenceI've looked through the coherence between
the MC length and seismometers after the
if-statement problem was fixed. Coherence
 coh_mcl_seis.pdfsensor_locker.pdf 
  6068   Mon Dec 5 02:55:30 2011 DenUpdateAdaptive FilteringC1OAFI've added filter banks for correction
path in the C1OAF model to use AA filters.
 I compiled and installed the new version.
  
  6070   Mon Dec 5 10:13:13 2011 JenneUpdateAdaptive FilteringC1OAF

    

       
            
  
  6078   Wed Dec 7 00:11:58 2011 DenUpdateAdaptive FilteringOfflineAF I did offline adaptive filtering
with yesterday's 3 hours of MC-F and GUR1X
data. It turns out that normalized-lms can
 offlineaf_psd.pngofflineaf_coh.png 
  6093   Fri Dec 9 13:28:09 2011 DenUpdateAdaptive FilteringC1OAFI tried to figure out why red NO SYNC label
became present in the C1OAF_GDS_TP screen
after I added AA filters to the C1OAF model.
  
  6094   Fri Dec 9 14:33:16 2011 Alex IvanovUpdateAdaptive FilteringC1OAF

    

       
            
  
  6100   Fri Dec 9 17:53:31 2011 DenUpdateAdaptive FilteringC1OAF[Jenne, Den]
AA filters for witness channels are
added to the oaf model. It is working now
  
  6110   Tue Dec 13 01:20:38 2011 DenUpdateAdaptive FilteringModifications to LSC, RFM models, added OAF model

    

       
            
  
  6137   Mon Dec 19 17:17:02 2011 DenUpdateAdaptive Filteringfilter tap dependenceOnline filter diverges. I did offline simulations
with current c-code. Offline filter also
diverges, even in the simplest case 
 OfflineAF.png 
  6199   Sun Jan 15 10:28:02 2012 DenUpdateAdaptive FilteringdelaysWe can account for delays in the oaf system
by compensating it in the adaptive path of
the filter. But using only this procedure
 2048_tau.png2048_delays.png 
  6200   Sun Jan 15 11:40:30 2012 DenUpdateAdaptive FilteringdownsamplingHere for the downsampling process we use
a low-pass Bessel digital filter of order
6, normalized cut-off frequency = 0.1. In
 2048_downsampling.png2048_512.png 
  6201   Sun Jan 15 12:18:00 2012 DenUpdateAdaptive Filteringrunning time In order to figure out what downsampling
ratio we can take, we need to determine the
running time of the fxlms_filter() function.
  
  6296   Sat Feb 18 17:01:26 2012 DenUpdateAdaptive Filteringstatic variablesIn order to prevent different DOF from
redetermining static variables in the adaptive
code, I've created a separate code for each
  
  6297   Sat Feb 18 18:29:38 2012 DenUpdateAdaptive Filteringonline filteringI tried to filter MC_F from seismic noise
measured by GUR1 seismometer. I've used 8000
tap filter, downsample ratio=8, delay=1.
 output.pdf 
  6332   Tue Feb 28 16:12:59 2012 DenUpdateAdaptive Filteringlunch talk Just to be clear what I said at the
meeting, I write all this down here. Adaptive
filtering of real signals (MC_F and GUR1_X)
 gains.pngwiener.png 
  6490   Thu Apr 5 18:24:55 2012 DenConfigurationAdaptive Filteringoaf starts to workToday I tried to make the lms filter to
work online. I played around with the signals
(GUR1_X and MC_F) to pre-whiten them and
 oaf2.pdf 
  6491   Fri Apr 6 09:57:24 2012 DenUpdateAdaptive Filteringstatic starts to workI made static filter to work to evaluate
the actuator TF.. Here is the result of static
filtering:
 7x 
  6492   Fri Apr 6 10:31:07 2012 DenUpdateAdaptive Filteringstatic and adaptiveI've run static and adaptive filters simultaneously.
AA32 filters rotate the phase of the witness
signals GUR1X and GUR1Y and now the performance
 static_oaf.pdf 
  6493   Fri Apr 6 11:14:34 2012 JenneUpdateAdaptive Filteringstatic and adaptive

    

       
            
  
  6551   Thu Apr 19 22:18:24 2012 DenUpdateAdaptive Filteringoaf algorithm: old vs new Here are the issues that I found
not quite accurate in the old oaf code:
1. There is no need to calculate
  
  6553   Fri Apr 20 23:02:25 2012 DenUpdateAdaptive Filteringfrequency domain filter DFT-LMS is a frequency domain adaptive
filter that demonstrates faster convergence
compared to the time-domain LMS filter.
 dft.pngnorm.png 
  6642   Fri May 11 23:33:41 2012 DenUpdateAdaptive Filteringoffline vs onlineI've compared offline Wiener filtering
with online static + adaptive filtering for
MC_F with GUR1_XYZ and GUR2_XYZ as witness
 off_on.jpg 
  7000   Sat Jul 21 18:04:02 2012 DenUpdateAdaptive Filteringfrequency domain filterI've implemented online frequency domain
filter and applied it to MC_F.
 freq_af.png 
  7234   Mon Aug 20 13:02:57 2012 DenUpdateAdaptive Filtering1 Hz resonanceStatic filter was adjusted to filter 1
Hz resonance in MCL and it could do it. Stack
is not great in this experiment due to the
 1hz.png 
  7252   Wed Aug 22 20:33:51 2012 DenUpdateAdaptive FilteringMC_L in ARMSJenne and I did adaptive filtering of MC_L
and measured how X and Y ARM control signals
change compared to non-filtered MC_L. We
 oaf_arms.png 
  7589   Mon Oct 22 20:44:49 2012 AyakaUpdateAdaptive Filteringmicrophone noiseI will do some experiments on acoustic
noise canceling during my stay.
Now I am planning to cancel acoustic
 mic_noise2.png 
  7592   Tue Oct 23 00:51:41 2012 JamieUpdateAdaptive Filteringmicrophone noise

    

       
            
  
  7596   Tue Oct 23 10:24:42 2012 AyakaUpdateAdaptive Filteringmicrophone noise

    

       
            
  
  7607   Wed Oct 24 14:15:34 2012 AyakaUpdateAdaptive Filteringmicrophone noisePrevious results
I am measuring the noise level of
the microphones. The circuit does not seems
 mic_open.pngmic_noise.png 
  7609   Wed Oct 24 15:29:52 2012 ranaUpdateAdaptive Filteringmicrophone noise  We have to change the sample
rate and AA filter for the mic channels before
going too far with the circuit design.
  
  7610   Wed Oct 24 17:02:01 2012 JenneUpdateAdaptive Filteringmicrophone noise

    

       
            
  
  7614   Wed Oct 24 22:20:24 2012 DenUpdateAdaptive Filteringmicrophone noise

    

       
            
 mic_64k.pdf 
  7621   Thu Oct 25 09:53:23 2012 AyakaUpdateAdaptive Filteringmicrophone noise

    

       
            
  
  7622   Thu Oct 25 10:03:38 2012 ranaUpdateAdaptive Filteringmicrophone noise  That's no good - we need BLRMS
channels for many PEM channels, not just
two. And the channel names should have the
  
  7623   Thu Oct 25 14:39:14 2012 DenUpdateAdaptive Filteringmicrophone noise

    

       
            
  
  7633   Fri Oct 26 18:25:02 2012 AyakaUpdateAdaptive FilteringMicrophone noise again[Raji, Ayaka]
Thanks to Den, power supplies for
microphone circuit are changed.
 mic_noise.png 
  7634   Fri Oct 26 19:06:14 2012 DenUpdateAdaptive FilteringMicrophone noise again

    

       
            
  
  7636   Mon Oct 29 08:41:22 2012 AyakaUpdateAdaptive FilteringMicrophone noise again

    

       
            
  
  7708   Tue Nov 13 21:05:35 2012 DenUpdateAdaptive Filteringonline and simulationFor a last few days I've been working on
oaf and simulink model to simulate it. First
I did online subtraction from MC when MC_L
 8x 
  7764   Fri Nov 30 02:40:44 2012 DenUpdateAdaptive FilteringYARMI've applied FIR adaptive filter to YARM
control. Feedback signal of the closed loop
was used as adaptive filter error signal
 yarm_oaf.png 
  7767   Fri Nov 30 11:49:24 2012 KojiUpdateAdaptive FilteringYARMThis is interesting. I suppose you are
acting on the ETMY.
Can you construct the compensation
  
  7769   Fri Nov 30 22:11:50 2012 DenUpdateAdaptive FilteringARMS

    

       
            
 arms_oaf.pdf 
  7771   Sat Dec 1 00:13:16 2012 DenUpdateAdaptive FilteringARMS and MC

    

       
            
 arms_mcl_oaf.pdf 
  7591   Tue Oct 23 00:41:55 2012 JenneUpdateAlignmentMC locked, spots centered[Jenne, Raji]
We replaced the MC Refl path BS with
the Y1, as usual, so that the full ~100mW
 Screenshot-Figure_1.png 
ELOG V3.1.3-