40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 208 of 337  Not logged in ELOG logo
ID Dateup Author Type Category Subject Text Attachments
  10413   Wed Aug 20 04:09:21 2014 ericqUpdateGreen LockingXarm Green PDHI've made
a whole bunch of measurements on the Xarm
green situation.
TL;DRs:

 Xbodes.pdfXspectra.pdfscopeSweep.jpg 
  10414   Wed Aug 20 15:31:27 2014 ericqUpdateCOCArm Loss Investigations Continue [ericq, Gabriele] 
Summary: After today's meeting, Gabriele
and I looked into the arm loss situation,
  
  10415   Wed Aug 20 16:10:43 2014 ericqUpdateGreen LockingXarm Green PDHA MIST simulation tells me that the green
pdh horn-to-horn displacement is about 1.2nm,
or ~18kHz. I used this, along with the scope
 XspectraCombined.pdf 
  10416   Wed Aug 20 18:05:18 2014 JenneUpdateGreen LockingYarm Green PDH - requirement 
 I calibrated the control signal
from Volts to Hz using the rough PZT calibration
 YPDH_noise.pdf 
  10417   Wed Aug 20 21:09:16 2014 ericqUpdateGreen LockingXarm Green PDHI remeasured all of the noise spectra again
today, making sure the input attenuation
was as low as it could safely be. I also
 scopeSweep.jpgXspectra.pdfYspectra.pdfXYcomp.pdf 
  10418   Thu Aug 21 02:42:17 2014 rana, ericqConfigurationGreen LockingGain changes on Green Y PDH[rana, ericq]
We spent time trying to relieve the
Yend green PDH of it troubles. 
 TEK00002.PNGTEK00003.PNG 
  10419   Thu Aug 21 15:07:48 2014 SteveUpdateVACRGA scan at day 197 
 
 RGAscan@d197.png 
  10420   Thu Aug 21 19:04:52 2014 ericqConfigurationGreen LockingGain changes on Green Y PDHI found that the barrel of one the BNC
to BNC connectors used for getting the output
of the PDH servo box to the laser controller
 TEK00005.PNG 
  10421   Thu Aug 21 22:10:52 2014 ranaSummaryComputer Scripts / Programsnetwork movements To help development of the data visualization
project, we've assigned the .101 and .102
IP to DataVis. This is being used by the
  
  10422   Fri Aug 22 03:55:45 2014 JenneUpdateLSCXarm PDH fine, Yarm PDH/ALS needs work[Rana, Jenne, EricQ]
We did several things tonight. 
First, a list (so I can remember them all),
 Xend_ErrorPointMeasurements.pdfDARM_ALSdiff_vs_sqrtInv.pdf 
  10423   Fri Aug 22 13:51:00 2014 JenneUpdateGeneralUpdated game plan   40mToDoList.pdf 
  10424   Fri Aug 22 15:11:55 2014 andres, nicolasSummaryIOOMC WFS activity1. Before doing anything, we centered the
IOO QPDs.
2. With the WFS enabled, we offloaded
  
  10425   Fri Aug 22 15:58:02 2014 SteveSummaryIOOMC WFS activity 
 
 GoyphaseSet.png 
  10426   Fri Aug 22 18:00:08 2014 jamieOmnistructureCDSubuntu12 awgstream installedI installed awgstream-2.16.14 in /ligo/apps/ubuntu12. 
As with all the ubuntu12 "packages",
you need to source the ubuntu12 ligoapps
  
  10427   Fri Aug 22 18:05:02 2014 AndresUpdateIMCUpgrade of the IMC WFSs for the reflection Upgrade of IMC Reflection Optical
Setup
Nick and I upgrade the IMC.
We move both WFSs and placed them facing
 ModeCleanerUpgrade.PNG 
  10428   Mon Aug 25 09:56:21 2014 SteveUpdateIMC IMC WFSs upgrade 
 The Napa earth quake magnitude
6 did not have any effect on the suspensions.
 eq6Mnapa.png 
  10429   Mon Aug 25 15:49:44 2014 SteveUpdatePSLHEPA turned onThe PSL HEPA was off. It was turned on
and it is running at 30VAC now.
  
  10430   Tue Aug 26 23:16:49 2014 ericqConfigurationGreen LockingGain changes on Green Y PDH Yesterday I measured the spectra
and OLTF of the Y-Arm green PDH, after the
LO touch-up and 60Hz hunt from last week.
 Ytfs.pdfpdhComparison.pdfnewY.zip 
  10431   Tue Aug 26 23:46:55 2014 ericqUpdateIMCWFS tuneup I decided to see what I could do
with the new WFS setup. 
First, I adjusted the WFS digital
 newWFSmatrix.pdf 
  10432   Wed Aug 27 09:12:47 2014 KojiUpdateIMCWFS tuneupI'm sure that the 1~3Hz motion comes from
the mirror motion, but not 100% sure what
is causing 
  
  10433   Wed Aug 27 18:03:47 2014 ericqUpdateGreen LockinguPDH Box Checkup Quick post of plots and data; I'll
fill in more detail tonight. 
TL;DR: I pulled both green PDH boxes
 uPDH_X.JPGuPDH_Y.JPGupdhTFs.pdfupdhNoises.pdfuPDH_Aug27.zip 
  10434   Thu Aug 28 01:41:03 2014 ericqUpdateLSCPhase Tracker UGF normalizationWe want both the X and Y phase trackers
to have the same UGF, so that the X and Y
ALS signals are subject to the same phase
 UGFnorm.png 
  10435   Thu Aug 28 08:31:16 2014 SteveUpdateGeneralone good day   1goodDay.png1gooday.png 
  10436   Thu Aug 28 11:02:53 2014 SteveUpdateCalibration-RepairSR785 repairSN 46,795 of 2003 is back.  08281401.PDF 
  10437   Thu Aug 28 17:34:20 2014 ericqUpdateGreen LockinguPDH Box CheckupI had noticed in the past, that the digital
control signal monitor for the X end would
saturate well before the ADC should saturate
 TEK00006.PNG 
  10438   Fri Aug 29 17:28:07 2014 ranaUpdateGreen LockinguPDH Box Checkup 
  
  10439   Fri Aug 29 23:53:35 2014 ericqUpdateGreen LockinguPDH Box CheckupI had pulled out both X and Y servo boxes
for inspection, put the Y box back, soldered
in a missing op amp power capacitor on the
  
  10440   Tue Sep 2 16:22:24 2014 JenneUpdateGeneralGame plan: 2 SeptSlightly updated Game Plan.  Mostly,
Q is continuing to check out the Xend PDH
box saturation, and I am thinking on what
 40mToDoList.pdf 
  10441   Tue Sep 2 20:02:06 2014 ericqUpdateGreen LockinguPDH Box CheckupI narrowed down the saturation point in
the X green PDH box to the preamp inside
the AD8336, but there is still no clear answer
  
  10442   Tue Sep 2 22:54:27 2014 KojiSummaryLSCphase tracker UGFFYI and FMI
Phase tracker UGF is  Q_AMP
* G * 2 PI / 360 where Q_AMP is
  
  10443   Wed Sep 3 00:17:22 2014 ranaUpdateGreen LockinguPDH Box CheckupWhat monitor point is being plotted here?
Or is it a scope probe output?
If this saturation is in the uPDH-X
  
  10444   Wed Sep 3 04:17:21 2014 JenneUpdateLSCY green ALS (not PDH) needs investigationQ put the X PDH box back, so that I could
try locking, and remember which end is up
after a week away.
 Yarm_noisy_above_20Hz.pdf 
  10445   Wed Sep 3 14:07:18 2014 ranaConfigurationGeneralnetgpibdata is working again now

    

       
            
  
  10446   Wed Sep 3 18:42:43 2014 JenneUpdateLSCGreen PDH box boostsFrom EricQ's simulations reported in elog
10390, we want to transition from ALS
 BoostCartoon.pdf 
  10447   Wed Sep 3 20:38:40 2014 ericqUpdateGreen LockinguPDH Box CheckupThe traces were from the front panel output
BNCs, but the VGA preamp exhibited this asymmetric
saturation at its output.  
  
  10448   Thu Sep 4 00:56:44 2014 JenneUpdateLSCGreen PDH box boostsOkay, went back to the drawing board with
Rana and Koji on PDH box stuff.
Currently (at least for the Yend),
 TFstage_newDesign_3Sept2014.pngBoostNoBoost_newDesign_3Sept2014.pngBoostOnly_newDesign_3Sept2014.pngD0901351-v1_3Sept2014.pdf 
  10449   Thu Sep 4 01:28:32 2014 ericqUpdateLSCRecycling cavity lengths Going off some discussion we had
at lunch today, here is my current knowledge
of the state of cavity lengths. 
  
  10450   Thu Sep 4 03:12:55 2014 ericqUpdateLSCGreen PDH box boostsJenne made her board modifications, and
the measured TF agreed with the design. Alas,
the green would not lock to the arm in this
 boostedTF.pdfgain.jpg 
  10451   Thu Sep 4 10:10:23 2014 KojiUpdateLSCRecycling cavity lengthsCom'on. This is just a 60ppm change of
the mod frequency from the nominal. How can
it change the recycling cav length by more
  
  10452   Thu Sep 4 16:45:10 2014 JenneUpdateLSCGreen PDH box boostsAs EricQ mentioned in last night's elog,
the modifications were made to the Yend (SN
17) uPDH board.
 IMG_1712.JPGIMG_1714.JPG 
  10453   Thu Sep 4 18:16:20 2014 ericqUpdateLSCRecycling cavity lengthsKoji correctly points out that I naïvely
overlooked various factors. With a similar
analysis to the wiki page, I get:
 2014-09-CavityLengths.zip 
  10454   Thu Sep 4 18:30:13 2014 GabrieleSummaryASCOptimal Gouy phase for POP QPD Jenne asked me to simulate the signals
on POP QPD when moving different mirrors,
as a function of the Gouy phase where the
 pop_qpd_dc.pngfortymeters.mistfortymeters_pop_qpd.mistpop_qpd.m 
  10455   Fri Sep 5 00:56:00 2014 ranaSummaryOptical LeversITM OLs recentered: violations foundI re-centered the ITMX & ITMY Optical
lever beams today since they were off. First
I aligned the beam into the vacuum so that
  
  10456   Fri Sep 5 03:36:00 2014 ranaUpdateComputer Scripts / Programsmartian wireless tweak I changed the Martian wireless router
to use channel 10 instead of something random
(as it was). Using the Android app 'Wifi
  
  10457   Fri Sep 5 04:07:44 2014 ericqUpdateGreen LockingX end uPDH Box ReplacedJust a quick note, plots and data will
come tomorrow:
I grabbed an unused uPDH board from
  
  10458   Fri Sep 5 05:32:57 2014 JenneUpdateLSCGreen PDH box boosts[Rana, Jenne, EricQ]
* Too much gain overall on Yend box,
needed attenuator on output to get lock. 
 TRX_TRY_ALSvsIR_4Sept2014.pdf 
  10459   Fri Sep 5 15:28:38 2014 SteveUpdateSUSHeNe laser test preparationThe SRM qpd was moved to accommodate the
HeNe laser qualification test for LIGO Oplev
use.
 beforeRSMqpdMoved.jpgafterSRMqpdMoved.jpg1103Ptest.pngND1onQPD.png 
  10460   Fri Sep 5 16:13:00 2014 ericqUpdateGreen Lockingnew X Green PDH measurements I measured the noise spectra and
loop TF of the green PDH with the newly stuffed
board. Unfortunately, I never took the noise
 6x 
  10461   Fri Sep 5 16:25:36 2014 SteveUpdateSUScenter ITMY oplev

    

       
            
  
  10462   Fri Sep 5 21:13:57 2014 JenneUpdateLSCGreen PDH out of loopI locked the arms with IR, and measured
the beatnote spectra to get the out of loop
noise for the PDH boxes. 
 ALS_XY_outOfLoop_5Sept2014.pdf 
ELOG V3.1.3-