ID |
Date |
Author |
Type |
Category |
Subject |
6472
|
Fri Mar 30 10:24:14 2012 |
steve | Update | SUS | new OSEM locking plunger |
Quote: |
Quote: |
Our existing 300 series SS plungers from McMastercar #8476A43 are silver plated as Atm2 shows.
Problems: 1, they become magnetized after years being close to the magnets
2, they oxidize by time so it is hard to turn them
I looked around to replace them.
Titanium body, nose and beryllium copper spring. None magnetic for UHV enviorment.
Can be made in 7 weeks at an UNREASONABLE $169.00 ea at quantity of 50
|
In order to get a better price from Vlier's Tom Chen I changed Ti body back to SS304L-siver plated and music wire spring. The price is still ~$120 ea. at quantity 50
I will talk to Mike G about modifying the McMaster plunger with a hex nut.
|
Conclusion: There is no need to silver plate the SS plunger at the torque level we hold the OSEMs
Mike Gerfen will be done with 50 pieces by April 4 and he will give them to Bob for cleaning. They should be cleaned and baked in a jig so the springs would be compressed for better venting. |
6471
|
Fri Mar 30 10:20:51 2012 |
kiwamu | Update | LSC | locking last night |
I was trying to make the DRMI lock more robust.
Increasing the gains of the oplev on SRM helped a lot, but the lock is still not solid enough for measurements.
According to some line injection tests, the SRCL and MICH signals show up in AS55Q with almost the same amplitudes.
I tried to diagonalize the input matrix (particularly MICH-SRCL in AS55) based on the result of the line injection tests, but I ran out the time.
Work continues. |
6470
|
Fri Mar 30 09:37:13 2012 |
steve | Update | SAFETY | safety audit 2012 CORRECTIONS |
Quote: |
Correction list by visiting safety committee, Haick Issaian is not shown:
1, update laser, crane operator list and post it
2, check fire extinguishers monthly, date and initials must be on the tags
3, move drinking water tower so it does not block fire extinguisher
4, post updated crane doc at cranes
5, post present phone lists at IFO room phones
6, emergency laser shutoff at the south end must be mounted without C-clamp
7, use heavy cable tie to insure position of mag-fan on cabinet top
Additional to do list:
a, safety glasses to be cleaned
b, let the electrical shop fix Rack-AC power to optical tables at the ends
c, measure transmission of laser safety glasses
d, update IFO outside door info signs
e, update laser inventory and post it
f, schedule annual crane inspection and renew maintenance contract
g, PSL enclosure inner shelf needs a good clean up so it is earthquake safe
|
Completed with the exception of d and g |
6469
|
Fri Mar 30 08:58:37 2012 |
steve | Update | SAFETY | Safety glasses checked |
Bob cleaned all safety glasses in 10 % Liquinox soap in water solution first. The transmittance of glasses were checked at 100 mW 1064 nm S polarization, beam diameter 0.5 mm at 0-20 deg incident.
Coherent FieldMate power meter measured T= < 1 mW of all glasses. |
6468
|
Thu Mar 29 20:13:21 2012 |
jamie | Configuration | PEM | PEM_SLOW (i.e. seismic RMS) channels added to fb master |
I've added the PEM_SLOW.ini file to the fb master file, which should give us the slow seismic RMS channels when the framebuilder is restarted. Example channels:
[C1:PEM-RMS_ACC6_1_3]
[C1:PEM-RMS_GUR2Y_0p3_1]
[C1:PEM-RMS_STS1X_3_10]
etc.
I also updated the path to the other _SLOW.ini files.
I DID NOT RESTART FB.
I will do it first thing in the am tomorrow, when Kiwamu is not busy getting real work done.
Here's is a the diff for /opt/rtcds/caltech/c1/target/fb/master:h
controls@pianosa:/opt/rtcds/caltech/c1/target/fb 1$ diff -u master~ master
--- master~ 2011-09-15 17:32:24.000000000 -0700
+++ master 2012-03-29 19:51:52.000000000 -0700
@@ -7,11 +7,12 @@
/opt/rtcds/caltech/c1/chans/daq/C0EDCU.ini
/opt/rtcds/caltech/c1/chans/daq/C1MCS.ini
/opt/rtcds/caltech/c1/target/gds/param/tpchn_c1mcs.par
-/cvs/cds/rtcds/caltech/c1/chans/daq/SUS_SLOW.ini
-/cvs/cds/rtcds/caltech/c1/chans/daq/MCS_SLOW.ini
-/cvs/cds/rtcds/caltech/c1/chans/daq/RMS_SLOW.ini
-/cvs/cds/rtcds/caltech/c1/chans/daq/IOP_SLOW.ini
-/cvs/cds/rtcds/caltech/c1/chans/daq/IOO_SLOW.ini
+/opt/rtcds/caltech/c1/chans/daq/SUS_SLOW.ini
+/opt/rtcds/caltech/c1/chans/daq/MCS_SLOW.ini
+/opt/rtcds/caltech/c1/chans/daq/RMS_SLOW.ini
+/opt/rtcds/caltech/c1/chans/daq/IOP_SLOW.ini
+/opt/rtcds/caltech/c1/chans/daq/IOO_SLOW.ini
+/opt/rtcds/caltech/c1/chans/daq/PEM_SLOW.ini
/opt/rtcds/caltech/c1/target/gds/param/tpchn_c1rfm.par
/opt/rtcds/caltech/c1/chans/daq/C1RFM.ini
/opt/rtcds/caltech/c1/chans/daq/C1IOO.ini
controls@pianosa:/opt/rtcds/caltech/c1/target/fb 1$
|
6467
|
Thu Mar 29 19:13:56 2012 |
Jamie | Omnistructure | Computers | Wireless router for GC |
I retrieved the newly "secured" router from Junaid. It had apparently been hooked up to the GC network via it's LAN port, but it's LAN services had no been shut off. It was therefore offering a competing DHCP server, which will totally hose a network. A definite NONO.
The new SSID is "40mWiFi", it's WPA2, and the password is pasted to the bottom of the unit (the unit is back in it's original spot on the office computer rack. |
6466
|
Thu Mar 29 18:42:11 2012 |
keiko | Update | LSC | POP22/POP110 amplifires |
Adding two amplifiers on POP22/110, I checked the signals going to the dmod board of 22 and 110.
The signal flows: Photodetector of POP --> Amp1 --> Amp2 --> RF splotter --> bandpass filter for 22MHz / 110MHz --> 22MHz / 110MHz demod board.
Here is the picture of RF spectrum just after the bandpass filter of 22MHz going to the 22MHz demod board. The signal peak at 22MHz is about -40dBm. There is a structure slightly lower than 22MHz.

The below is the RF spectrum for 110MHz branch. The peak at 110MHz is about -15dBm. The peak on the left of 110MHz is 66MHz peak.

Quote: |
Yesterday I and Kiwamu connected two amplifiers (mini-circuit, ZFL-1000LNB+) for POP22/110. Dataviewer can see some signals. I'll test the signal levels and freq components before the rack just in case. [Kiwamu, Keiko]
|
|
6465
|
Thu Mar 29 13:23:05 2012 |
Jenne | Omnistructure | Computers | Wireless router for GC |
Quote: |
I installed a NETGEAR Wireless Router (WPN824N) today on the 131 network. The admin password for it as well as the wireless access password are in the usual places.
The SSID is 40EARTH. I have set it to allow WPA as well as WPA2 access, so the speed is only 54 Mbps for now. In a year or so, we can turn off the WPA support and up the speed.
|
This router was confiscated by the GC guys this morning around ~10am. They barged in and said that someone at the 40m had connected a new router, and we had magically taken down half of the GC network. The cable was plugged in to the wrong port on the back of the router.
Junaid / Christian said that they would "secure" the router, and then reinstall it. Apparently just having a password didn't satisfy them. This was the compromise, versus them just taking the router and never bringing it back.
|
6464
|
Thu Mar 29 11:29:27 2012 |
keiko | Update | LSC | POP22/POP110 amplifires |
Yesterday I and Kiwamu connected two amplifiers (mini-circuit, ZFL-1000LNB+) for POP22/110. Dataviewer can see some signals. I'll test the signal levels and freq components before the rack just in case. [Kiwamu, Keiko] |
6463
|
Wed Mar 28 21:15:53 2012 |
rana | Omnistructure | Computers | Wireless router for GC |
I installed a NETGEAR Wireless Router (WPN824N) today on the 131 network. The admin password for it as well as the wireless access password are in the usual places.
The SSID is 40EARTH. I have set it to allow WPA as well as WPA2 access, so the speed is only 54 Mbps for now. In a year or so, we can turn off the WPA support and up the speed. |
6462
|
Wed Mar 28 20:54:02 2012 |
Jenne | Update | IOO | Beam Profile measurement: IPPOS beam |
I fitzed by hand with the numbers for the incident angles on MMT1 and MMT2, and then let the code optimize the position of MMT1 and MMT2.
Here I have set the incident angle for MMT1 = 25deg, and MMT2 = 12deg (should be 3.5deg, 1deg by design). The length of the telescope doesn't want to change by more than 7mm, but the position of the telescope wants to change by 1.3meters. Is it possible that the distances on the Monday IPPOS measurements aren't actually correct?

|
6461
|
Wed Mar 28 18:26:47 2012 |
Jenne | Update | IOO | Beam Profile measurement: IPPOS beam |
More calculations....
Game Plan: Using MC waist measured beam as the starting point of beam propagation, move MMT mirrors around until the beam profile fits with the IPPOS measurements from Monday.
Plot 1: Allow MMT mirrors to move as much as they want to. Note that the Y-beam goes through the IPPOS measured point. (This implies we put the MMT in the wrong place by ~half a meter. Unlikely)
Plot 2: Using MMT locations from plot 1, what does the beam look like at the ITMs?
Plot 3: Allow MMT mirrors to move as much as 2cm. Note that the Y-beam doesn't quite go through IPPOS measured point.
Plot 4: Using MMT locations from plot 3, what does the beam look like at the ITMs?
For all of the above, I was optimizing the propagation of the Y-beam profile. Since the X-beam profile measurement is so different, if I want to optimize to X and let the MMT mirrors move as much as they want, MMT1 ends up inside the MC. Unlikely. So I'm just looking at Y for now, and maybe Suresh or someone needs to rethink the error bars on their measurements or just remeasure.
Plot 1:

Plot 2:

Plot 3:

Plot 4:

|
6460
|
Wed Mar 28 01:17:29 2012 |
Jenne | Update | IOO | Beam Profile measurement: IPPOS beam |
As I was a little dissatisfied with the inaccuracy in the distance numbers in Kiwamu's sketch, I went back to the 18 Dec 2010 table layout drawing for more accurate numbers. These are now included in this round of plots.
Also, I include astigmatism due to the incident angles on MMT1 (~3.5 deg) and MMT2 (~1 deg).
First plot, IPPOS path, using the recent (fixed) measurements from Suresh to fix the beam width. Note that the old 2010 measurements of the MC waist are consistent with this measurement.
Second plot, Main IFO path all the way to the ITM (average) position, using the 2010 MC waist measurements to fix the beam width.
Third plot, Main IFO path all the way to the ITM position, but with PRM flipped (negative RoC), using the 2010 MC measurement to fix beam width.
With the PRM correctly oriented (2nd plot), I get beam waists of (x = 2.529 mm, y = 2.646 mm), which corresponds to a mode matching to the arm cavity of (eta = 97.43%, PRM correct).
With the PRM flipped (3rd plot), I get beam waists of (x = 3.176 mm, y = 3.3 mm), which corresponds to a mode matching to the arm cavity of (eta = 99.55%, PRM flipped).
First plot:

Second plot (this is how the MMT was designed to be, before the ETMs were moved, which made the ideal waist larger):

Third plot:

For both the 2nd and 3rd plot, we can't look at the post-MMT waist measurements, since that distance on the plots is after the PRM, which is a curved optic. So the fact that the post-MMT measurements match the correct-PRM plot better than the flipped-PRM plot can't be taken to be meaningful.
Moral of the story: I'm not sure how to interpret any of this to tell us if the PRM is flipped or not, since the measurements are all of the beam profile before the beam sees the PRM. We'd have to measure the profile after the PRM somehow in order to get that information. We have okay but not great mode matching to the arm if the PRM is correct, but I don't know that we readjusted the MMT after we moved the ETMs. I don't remember recalculating any optimal telescope lengths after the arm length change. If we need better mode matching, I can do that calculation, although given how much space we don't have, it would be hard in practice to move the MMT mirrors by much at all. |
6459
|
Tue Mar 27 23:37:35 2012 |
Suresh | Update | IOO | Beam Profile measurement: IPPOS beam |
Quote: |
Quote: |
The moral of the story that I'm getting from this plot: something funny is going on.
|
Yup, something funny was going on. Nic's MM code that I used, "a la mode", calls for the focal length of the optics, whereas the code that I wrote and used for ages called for the radius of curvature. f = R/2. Fixing that factor of 2 I get something more like:
.....
So, what does it all mean? That I'm not sure of yet.
|
In an attempt to estimate the errors on the fit parameters I upgraded my Mathematica code to use the function 'NonlinearModelFit', which allows us to define weights and also reports the errors on the fit parameters. The plots have been upgraded to show the error bars and residuals.

The parameters determined are given below and compared to the earlier measurements of 06/18/2010
Vertical Profile:
Parameter |
Estimate |
Standard Error |
95% Confidence interval |
06/18/2010 measurement |
Waist (mm) |
2.768 |
0.005 |
2.757 -- 2.779 |
2.81 |
Waist location from MMT2 (m) |
5.85 |
0.12 |
5.625-- 6.093 |
5.36 |
Horizontal Profile:
Parameter |
Estimate |
Standard Error |
95% Confidence Interval |
06/18.2010 measurement |
Waist (mm) |
2.476 |
0.009 |
2.455 -- 2.496 |
2.91 |
Waist Location from MMT2 (m) |
4.935 |
0.145 |
4.645 -- 5.225 |
1.96 |
There is a significant change in the beam waist location (as compared to previous report) because I corrected a mistake in the sign convention that I was using in measuring the distances to the waist from the zero-reference.
|
6458
|
Tue Mar 27 21:37:51 2012 |
keiko | Configuration | IOO | Beam Profile measurement: IPPOS beam |
From the mode measurement I and Suresh have done yesterday, I calculated what beam size we expect at ETM ((1) upper Fig.1) and at ETM after one bounce ((2) lower Fig.1).

Fig.1 (Yarm)
In case of (1), we expect approximately w=6300 um (radius), and w=4800 um for one-bounce spot (2) from the measured mode, see Fig.2.

Fig.2
This roughly agree with what we observed on CCD camera. See, pic1 for (1) and pic2 for (2). The spot at the ETMY (1) is larger than the one-bounced spot (2). From the monitor it is difficult to assume the radius ratio. The observed spot of (2) is a bit smaller than the prediction. It could happnen when (A) the ETMY (as a lens) is slightly back of the ideal position (= the distance between the ITM and ETM is longer than 40m) (B) the real waist is farer than ITM position toward MC (I assumed roughly 5 m from Jenne's plot, but could be longer than that).

pic1 (left): beam spot hitting on the suspension frame. pic 2 (right): the one-bounced beam spot hitting on the suspension frame.
|
6457
|
Tue Mar 27 21:20:32 2012 |
Jenne | Update | IOO | Beam Profile measurement: IPPOS beam |
Quote: |
The moral of the story that I'm getting from this plot: something funny is going on.
|
Yup, something funny was going on. Nic's MM code that I used, "a la mode", calls for the focal length of the optics, whereas the code that I wrote and used for ages called for the radius of curvature. f = R/2. Fixing that factor of 2 I get something more like:

This is obviously much better, in that the beam profile goes through (within some error) both of the measured sets of points - the MC waist measured in May 2010, and after the MMT measured yesterday.
So, what does it all mean? That I'm not sure of yet. |
6456
|
Tue Mar 27 18:03:46 2012 |
Jenne | Update | IOO | Beam Profile measurement: IPPOS beam |
This is wrong! See following elog for corrected plot (and explanation)
I'm not done meditating on what's going on, but here's what I've got right now:

This is a beam profile, using the distances from the combined Kiwamu / Jenne sketch earlier today.
0 meters along the horizontal axis is meters from the Mode Cleaner waist. (Yes, I was bad and forgot to label it. Get over it.)
The pink and green dots to the left of the plot are the MC fitted waist measurements that we made in May 2010.
The pink and green dots in the ~center of the plot are the fitted waist measurements that Suresh and Keiko took yesterday, of the IPPOS path, so after the MMT.
The black dot is where we would like our non-astigmatic beam to be. This is the calculated waist size of the cavity mode, using the new ~37.76m distance, after we moved the ETMs to their current positions. The black dot indicates 3.036 mm at the ITM (averaged between the BS-ITMX and BS-ITMY distances).
The moral of the story that I'm getting from this plot: something funny is going on.
The distances Kiwamu quoted on the sketch are very close to the ones that I used for designing and checking the MMT in the first place, which were based off of measurements using rulers etc to measure distances. Steve said he looked at photos today, and agreed that Kiwamu's numbers looked reasonable also.
Something that we haven't done lately is measure the position of each optic from every other optic, along the beam path. I propose we come up with a clever way to put a target on top of / next to mirrors, and then a way to hold the laser distance measure-er at an optic, so that we can go thorough systematically and measure the actual path that our beam is seeing. Maybe this is too much work, and not worth it, but it would make me happier. In my head, these 'fixtures' are just small pieces of cleaned aluminum, one that can sit on a mirror mount, and one which we can use to align the laser ruler to approximately the front of an optic. Nothing fancy. |
6455
|
Tue Mar 27 17:52:08 2012 |
Koji | Update | IOO | Another possibility / thought |
It is quite likely that we touched the Faraday in Nov 2010.
In this entry http://nodus.ligo.caltech.edu:8080/40m/3874 I wrote that I removed the MCT optics in the chamber.
This is the pickoff between the IMC and the Faraday. This causes the beam shift. Therefore, the Faraday had
to be moved.
There were intensive in-chamber activities from Nov to Dec 2010. I am sure that almost everytime we went into
the chamber, we checked the spot position on the MMT mirrors as well as the TT and PZT mirrors.
Does the miscentering of the spots on the MMT mirrors cause the mode matching significantly changed? |
6454
|
Tue Mar 27 17:38:03 2012 |
Jenne | Update | IOO | Another possibility / thought |
I'm meditating over the mode matching from the mode cleaner to the ITMs, and I had another thought:
Have we changed the pointing of the MC significantly enough that we are no longer on the center of the MMT mirrors? To be this significant, we would probably also have had to scoot the Faraday a bit too, since it's skinny like a straw. It looks like our measurements of the input beam have been the following:
MC waist, 21 May 2010
After MMT2, 18 June 2010 (a few days before this, we flipped the MMT2 mount to 'perfect' the mode matching up to 99.3%, so I don't think the MMT has moved since then.)
After MMT2, 26 March 2012
There's a big o' ~2 year gap between our measurements, and we've been in and out of the vacuum a few times since then. I'll flip through the elog, but does anyone have any memory of us moving the Faraday after June 2010? When was the last time we made sure that we were at least close to the center of the MMT mirrors? |
6453
|
Tue Mar 27 17:19:02 2012 |
Koji | Update | IOO | Beam Profile measurement: IPPOS beam |
The mode looks quite terrible in the plot, but in reality it is an illusion of the plot.
The actual TEM00 content in this beam is ~99.7%
mode_coupling.pdf
Based on the above document, you can calculate power coupling between two elliptic gaussian modes.
Give the parameters of one beam as
zRy1 = pi*(2.77e-3)^2 / 1064e-9
z1y = 3.37
zRx1 = pi*(2.47e-3)^2 / 1064e-9
z1x = 4.15
Then, assume a round beam for the other.
zRx2 = zRy2 = zR
z2x = z2y = z0
Then run the optimizer to find the maximum for the quantity |C|^2
|C|^2 max: 0.9967
zR = 20.19
z0 = 3.804
|
6452
|
Tue Mar 27 16:06:59 2012 |
keiko | Update | IOO | Beam Profile measurement: IPPOS beam |
I changed the ETMY CCD camera angle so that we can see the suspension frame in order to repeat the same thing as yesterday. The ETMY camera is not looking at the beam or mirror right now. |
6451
|
Tue Mar 27 11:54:18 2012 |
Jenne | Update | IOO | Beam Profile measurement: IPPOS beam |
I'd like to know what we expect for these numbers. I've added to Kiwamu's drawing some more distances, so I can calculate the expected beam size at the IPPOS port.

Quote: |
|
Vertical |
Vertical
06/18/2010
|
Horizontal |
Horizontal
06/18/2010
|
waist (radius) (mm) |
2.77 |
2.81 |
2.47 |
2.91 |
Rayleigh length (m) (computed) |
22.62 |
|
18.14 |
|
Waist location w.r.t. to MM2 * |
3.37 |
5.36 |
4.15 |
1.96 |
|
|
6450
|
Tue Mar 27 02:46:28 2012 |
kiwamu | Update | IOO | REFL beam available |
The dump and some temporary mirrors were removed and now the REFL beam is available again.
I locked PRMI with REFL signals, it locked as usual.
Quote from #6440 |
Currently the REFL beam is bypassed by additional mirrors and blocked by a razor blade dump.
|
|
6449
|
Tue Mar 27 02:18:31 2012 |
keiko | Update | IOO | Beam Profile measurement: IPPOS beam |
Keiko, Rana, Suresh
Related to the beam profile of IPPOS today, we tried to measure the beam size at the ETMY point in order to estimate the input beam mode. We measured the beam size hitting at the suspension frame by a camera image, with two situations to see two "z" for beam profile.
(1) Input beam is slightly misaligned and the injected beam hits the end mirror frame. Assuming z=0 at the input mirror, this should be z=40m.
(2) Input beam hits the centre of the end mirror, and ITMY is slightly misaligned and the beam hits the end mirror frame after the one-round trip. Assuming z=0 at the ITM, this position should be z=120m.

The injected beam at the end point and the one round trip ligt at the end point should be the same size, if the input mode matches to the cavity mode. You can see if your injected light is good for the cavity or not. We compared and assumed the above two beam sizes by looking at the photo of the beam spot.
(1) (2) 
Assuming the zoom factor difference by the part below the beam (shown with allow in the photos. Arbitrary unit.), the beam in (2) is smaller than expected (roughly 40%?).
However this is a very rough estimation of the beam sizes! It is difficult to assume the beam size shown on the photos! It looks smaller only because the power of (2) is smaller than of (1). I don't think we can say anything from this rough estimation. One may be able to estimate better with CCD camera instead of this normal camera.
|
6448
|
Tue Mar 27 02:05:40 2012 |
Suresh | Update | IOO | Beam Profile measurement: IPPOS beam |
Quote: |
[Keiko, Suresh]
|
Vertical |
Horizontal |
Waist (mm) |
2.77 |
2.48 |
Rayleigh length (m) |
23.5m |
15.87 |
Waist location (m) |
0.81 m |
1.85 |

|
If we assume the nominal wavelength of the IR light to be 1064nm and constrain the Rayleigh length to be zr = (pi w0^2)/lambda we obtain the following fit parameters: (these are compared with the beam profile measurements of June/18/2010 available in the wiki )
|
Vertical |
Vertical
06/18/2010
|
Horizontal |
Horizontal
06/18/2010
|
waist (radius) (mm) |
2.77 |
2.81 |
2.47 |
2.91 |
Rayleigh length (m) (computed) |
22.62 |
|
18.14 |
|
Waist location w.r.t. to MM2 * |
3.37 |
5.36 |
4.15 |
1.96 |
* I updated the waist waist location coz because I missed-out the distance in air from the vacuum port to the optic on the IPPOS table.

|
6447
|
Mon Mar 26 23:47:54 2012 |
Suresh | Update | IOO | Beam Profile measurement: IPPOS beam |
[Keiko, Suresh]
Keiko and I measured the IPPOS beam profile. The fit parameters are :
|
Vertical |
Horizontal |
Waist (mm) |
2.77 |
2.48 |
Rayleigh length (m) |
23.5m |
15.87 |
Waist location (m) |
0.81 m |
1.85 |

The data files are attached. |
6446
|
Mon Mar 26 18:04:43 2012 |
kiwamu | Update | IOO | mode scan at the REFL port |
For those who are interested in the actual data, I attache the actual data in zip file together with a python plot code.
The distance was set such that the 1st steering mirror (the one at the very left in the previous cartoon diagram #6445 ) in the REFL path is positioned at zero.

- - - Fitting results (chi-square fitting done by gnuplot):
All values are in unit of meter
# PRM (v) (Last tree points are excluded as the beam were clipped at the aperture of the beam scan)
w0 = 0.0015114 +/- 2.192e-05 (1.451%)
z0 = -4.46073 +/- 0.05605 (1.256%)
# PRM (h)
w0 = 0.00212796 +/- 1.287e-05 (0.6049%)
z0 = -2.53079 +/- 0.1688 (6.668%)
# ITM (v) (Last two points are excluded as the beam were clipped at the aperture of the beam scan)
w0 = 0.00190696 +/- 4.964e-05 (2.603%)
z0 = -8.09908 +/- 0.1525 (1.882%)
# ITM (h)
w0 = 0.0032539 +/- 4.602e-05 (1.414%)
z0 = -1.89484 +/- 1.524 (80.42%)
|
6445
|
Mon Mar 26 16:25:44 2012 |
kiwamu | Update | IOO | expected v.s. measured beam profile of PRM reflection |
[Suresh / Kiwamu]
We did the 2nd round of the PRM reflection mode scan on Friday.
It seems that the PRM curvature maybe correct if we look at the vertical mode, however but the horizontal mode doesn't seem to agree with any of the expected lines.
In order to increase the reliability of the measurement, we need to confirm the beam profile of the incident beam by looking at the IP-POS beam.
Right now Suresh and Keiko are mode-scanning the IP-POS beam.
The plot below shows both the expected beam profiles (see the detail in #6444) and the actual data.

This plot is the same as one shown in the previous entry ( #6444) with newly added actual data.
The errorbar in each data point is the standard deviation obtained by 100 times of averaging.
In this plot I made the error bars 10 times bigger in order to let them visible in the plot, so the actual deviation is much lesser than they appear.
(Discussion)
The vertical profile (shown in red) seems to be close to the curve for the correct PRM case.
However the horizontal profile has a bigger waist size of about 2 mm.
While measuring the waist size Suresh and I have noticed that the rotational angle of the scan head affects the measurement by 10% or so.
Of course in each data point we tried making the incident beam normal to the scan head by rotating the scan head.
But this 10% is not big enough to explain the discrepancy in the horizontal mode.
There are some possible scenario which can distort the beam shape in the horizontal direction:
- Clipping at some optics. (Since the beam shape looked very Gaussian, the amount of the clipping could be very slight ?)
- Astigmatism at some optics. (Possibly in the telescope ?)
(Some distances)

(Some notes)
We did the following things prior to the measurement.
- Put a boost filter in the PRM_OLYAW to suppress the beam jitter below 1 Hz.
- Checked the MC WFS servo loop although it looked healthy.
Quote from #6444 |
I have estimated how the mode profile of the PRM reflection should be, as shown in the plot blow.
A conclusion here is :
we should be able to constrain the PRM curvature situation if measurements are precise and accurate enough with a level of less than ~ 100 um
|
|
6444
|
Mon Mar 26 15:15:16 2012 |
kiwamu | Update | IOO | expected beam profile of PRM reflection |
I have estimated how the mode profile of the PRM reflection should be, as shown in the plot blow.
A conclusion here is :
we should be able to constrain the PRM curvature situation if measurements are precise and accurate enough with a level of less than ~ 100 um
In the calculation two cases are considered :
(1) PRM has the correct curvature of +122 m. This is shown as solid curves in the plot.
(2) PRM has a wrong curvature of - 122 m (mirror is flipped) This is shown as dashed curves in the plot.

The plot above shows beam radii of the PRM reflections for vertical and horizontal profiles in each case.
The x-axis is distance from PRM in meter and the y-axis is the beam radii in mm.
As for the initial beam parameter, I used the measured values ( see the wiki), which are that of after the beam exits from the mode matching telescope and before it goes to PRM.
(1) If PRM has the correct curvature, the reflection after it passes MMT1 will have ~ 1.6 mm beam radii.
This is intuitively correct because the beam profiles should match to that of the MC exiting beam ( see the wiki), which has waist size of 1.5 - 1.6 mm if everything is perfect.
(2) When PRM is flipped, the beam starts converging at the beginning as PRM act as a convex mirror, resulting in smaller beam sizes after it comes out from the telescope.
Roughly speaking the waist sizes will be different by ~ 5 mm between those two cases, so our measurement should be more precise and accurate than this number.
Note:
I have omitted the effect from the PRM thickness. Therefore PRM is dealt as just a curved reflector with RoC of +/- 122 m in the calculation.
|
6443
|
Mon Mar 26 12:50:24 2012 |
Zach | Update | elog | restarted with script |
On the plus side, it was the first time I've had to do it in a while.. |
6442
|
Sun Mar 25 20:13:31 2012 |
rana | HowTo | SUS | Optical Lever Servo Tuning thoughts |
To start the optical lever filter design, I looked into the noise on ITMY. It should be similar to the other arm cavity optics since they have the same whitening electronics.
The RED/BLUE are with loops open. The MAGENTA/CYAN with loops closed. Looks good; the bandwidth is a few Hz and there is not much peaking,
To figure out the contribution from the dark noise I misaligned the ITMY until the sum on the QPD went to zero. Then I took the spectra of the OL{1,2,3,4}_OUT signals (they all looked the same).
To normalize them properly I took OL4, multiplied it by 2 to account for the incoherent sum of 4 channels and then divided by the nominal SUM (which was 14685 counts). I've left the OL3 un-normalized to show the ratio.
From this plot it seems that the dark noise is not a problem at any frequency (no need to amplify for the new ADCs).
I'm going to use the open loop spectra to design the optimal feedback control. The file is saved as /users/rana/dtt/ITMY_OL-120325.xml |
6441
|
Fri Mar 23 05:10:46 2012 |
Suresh | Update | IOO | Beam Profile measurements: Errors too large to yield good fits. |
[Kiwamu, Suresh]
Today we attempted to measure the beam profile of the REFL beam under two conditions:
(a) with PRM aligned and ITMs misaligned
(b) with PRM misaligned and ITMs aligned
The raw data is shown below. In each of the above conditions we measured in both the vertical (v) and horizontal (h) directions. The measurements in the vertical direction were better than the ones in the horizontal direction because the optics had a horizontal oscillation which gave larger errors in measurement.

Looking at the general trend of these lines it is clear that modes are not matched since the beam reflected by the PRM has a different divergence than that reflected from ITMs. The beam is also astigmatic as the vertical and horizontal directions have different divergences.
I could find beam parameters only for the Blue line above (Profile in the vertical direction while PRM was aligned). The fit is quite sensitive to the data points close to the waist, so we need to make better (lower St.Dev.) measurements near the AP table closer to the beam waist. The intensity with only one ITM aligned is too low and also contributes to the errors. The beam size is close to 6mm in the horizontal direction, this coupled with yaw oscillations give large errors in this measurement.
Here is the only reliable fit that could be obtained, which is for the prompt reflection from the PRM in the vertical direction

The fit function I used is Beam Dia = Waist { Sqrt [ 1+ ((z + z0)/zr)^2). The fit parameters we get for this data are
z0 = 7.7 m
Waist = 2.4 mm
zr = 6.9 m
Will make another attempt later today...
|
6440
|
Fri Mar 23 01:59:59 2012 |
kiwamu | Update | IOO | REFL beam currently unavilable |
[Suresh / Kiwamu]
Currently the REFL beam is bypassed by additional mirrors and blocked by a razor blade dump.
Therefore the signals associated with the REFL ports (e.g. REFL11, REFLDC and etc.) are unavailable.
Just be aware of it. |
6439
|
Thu Mar 22 23:43:56 2012 |
Koji | Update | CDS | c1scx and c1scy not properly running |
Did you guys checked if the simplant switch is set to "REAL WORLD" mode?
Edit by KI:
Bingo ! The input signals were bypassed to the simplant. I switched the simplant settings to REAL WORLD and now both end suspensions are working fine. |
6438
|
Thu Mar 22 17:41:15 2012 |
suresh | Update | CDS | c1scx and c1scy not properly running |
Quote: |
It seems that neither c1scx nor c1scy is working properly as their ADC counts are showing digital-zeros.
Quote from #6434 |
The power was turned back on at 4pm It took some time for Suresh to restart the computers. We have damping but things are not perfect yet. Auto BURTH did not work well.
|
|
When Steve and I restarted the c1iscex and c1iscey computers after the power shutdown, the models within them did not start-up automatically. I had to start them manually from a terminal in the control room.
I also tried rebooting the FB a couple of times. Did not make any difference.
Manually starting the c1x05, c1scy and c1x01, c1scx models (with the Burt Restore button ON) did not resolve the issue of zeros in the epics screens. though it did re-establish timing. |
6437
|
Thu Mar 22 17:35:59 2012 |
kiwamu | Update | Locking | mode profiles of the POP and POX beams : not bright enough |
I tried to measure the beam profiles at the POP and POX ports as Koji mentioned in his entry (#6421).
However it turned out that the beam powers were too small to be measured with our beam scan at those ports.
So I will move on to measurements at the REFL port as Rana suggested because the laser power is much larger than that of POP and POX.
(If the data of the POP and POX beam profiles turn out to be very necessary, we will do the razor blade technique with a more sensitive photo diode)
Quote from #6421 |
More precise analysis can be done with quantitative analysis of those two spots with Beamscan. This could happen tomorrow.
|
|
6436
|
Thu Mar 22 16:45:06 2012 |
kiwamu | Update | CDS | c1scx and c1scy not properly running |
It seems that neither c1scx nor c1scy is working properly as their ADC counts are showing digital-zeros.
However the IOPs, c1gcx and c1gcy look running fine, and also the IOPs seem successfully recognizing the ADCs according to dmesg.
Also there is one more confusing fact : c1scx and c1scy are synchronizing to the timing signal somehow.
I restarted the c1scx front end model to see if this helps, but unfortunately it didn't work.
As this is not the top priority concern for now, I am leaving them as they are now with the watchgods off.
(I may try hardware rebooting them in this evening)
Quote from #6434 |
The power was turned back on at 4pm It took some time for Suresh to restart the computers. We have damping but things are not perfect yet. Auto BURTH did not work well.
|
|
6435
|
Thu Mar 22 08:14:21 2012 |
steve | Update | Green Locking | dichroic mirror quotes with large wedge |
Quote: |
Dichroic mirror quotes are in the wiki.
ATF is pricy.
We got a good price from Laseroptik, but the wedges are 5 arcminutes. The fused silica grade is 0F, meaning the homogeneity is 5 ppm instead of 1ppm. I requested an other large wedge quote on the substrates.We may have to get substrates from somebody else and ship it to Germany
MLT quote is outrageously high
REO is not interested in this low volume job.
|
The Laseroptik quote is here.The 2 degrees wedge cost is $40 on each optics! See wiki |
6434
|
Wed Mar 21 19:12:27 2012 |
steve | Update | Computers | AC power back on both ends |
Quote: |
Quote: |
ETMY sus damping was disabled. Green locking laser and associated electronics turned off. Computers and power supplies turned off at rack 1Y4
The electricians picking up ac power from 1Y4 manual disconnect box and installing conduit line to ISCT-ETMY east end optical table.
There will be no more daisy chaining this way.
|
The power is back on at ETMY . c1iscey has not been restarted.
Now I'm turning ac power off at ETMX for the same job to be done.
|
The power was turned back on at 4pm It took some time for Suresh to restart the computers. We have damping but things are not perfect yet. Auto BURTH did not work well. |
6433
|
Wed Mar 21 11:32:47 2012 |
steve | Update | SAFETY | AC power to ETMX turned off |
Quote: |
ETMY sus damping was disabled. Green locking laser and associated electronics turned off. Computers and power supplies turned off at rack 1Y4
The electricians picking up ac power from 1Y4 manual disconnect box and installing conduit line to ISCT-ETMY east end optical table.
There will be no more daisy chaining this way.
|
The power is back on at ETMY . c1iscey has not been restarted.
Now I'm turning ac power off at ETMX for the same job to be done. |
6432
|
Wed Mar 21 10:31:28 2012 |
steve | Update | SAFETY | AC power to ETMY turned off |
ETMY sus damping was disabled. Green locking laser and associated electronics turned off. Computers and power supplies turned off at rack 1Y4
The electricians picking up ac power from 1Y4 manual disconnect box and installing conduit line to ISCT-ETMY east end optical table.
There will be no more daisy chaining this way. |
6431
|
Tue Mar 20 17:50:44 2012 |
Suresh | Update | Computers | Beam Scan machine fixed |
There was something wrong with the Beam Scan PC. The mouse and screen were not responding and the PC was asking for drivers for any new hardware that we plugged in. We called in the services of Junaid and co. since we do not have a Win98 Second Edition installation disk in the lab. Junaid came with the disk, we changed the screen and the mouse and installed everything.
We tried to get the network going on the PC so that we could update stuff easily over the net. This didnt succeed. For now, we still have to depend on a Win98se CD to get drivers if any new hardware is connected to this machine.
For future reference, some notes:
1) We will get a copy of Win98SE for the lab from Junaid
2) We have to use a USB mouse from Dell. We have several spares of this. The drivers for these are present in the machine.
The Beam Scan is working okay now. We will proceed with the beam profile measurements. |
6430
|
Tue Mar 20 16:53:48 2012 |
steve | Update | PEM | cranes maintenance & certified inspection of 2012 |
Fred Goodbar of Konecrane has completed the annual certified crane inspection and maintenance of our cranes as required in safety document.
They are in good working condition and safe to use. |
6429
|
Tue Mar 20 09:59:01 2012 |
steve | Update | IOO | Laser tripped off |
Today is janitor day. It still does not explain why the 2W Innolight tripped off about an hour ago. All back to normal.
.......................................................I asked Keven later, he admitted hitting the emergency shut off next to the chemical storage cabinet. |
6428
|
Mon Mar 19 21:25:31 2012 |
Suresh | Update | Electronics | REFL165 calibration : measurements |
Quote: |
To characterize the RF V to counts we need to know the state of the whitening filter board. Was the filter on or off ? What was the value of the whitening gain slider?
|
The filter was ON and the whiterning filter gain was 45dB
|
6427
|
Sun Mar 18 00:29:24 2012 |
Den | Update | PEM | sts-2 |
I've turned off the power of the STS-2 readout box as it provides outputs with ~10 Volts DC offset! AA filter box works in the range -2 +2 Volts, so we do not have any useful information anyway. I'll adjust the mass positions in the seismometer. |
6426
|
Fri Mar 16 16:03:03 2012 |
kiwamu | Update | IOO | MC alignment servo : put some offsets in the TRANS QPD signal |
The MC alignment servo wasn't great in the last 1 hour or so as it kept disturbing the MC lock. It was found to be due to some offsets in the MC trans QPD signals.
I put some values to cancel the offsets and then the lock became stable.
This is a first aid. So we need to take a closer look at the QPD signals and also probably the spot position on the QPD.
The symptom was that every time the alignment servo was engaged, at the beginning the amount of the transmitted light went to 27000 counts, which is good.
However, then the amount of the transmitted light slowly decreased in a time scale of ~ 20 sec or so, ending up with destruction of the MC lock.
According to the time scale I suspected that the servos using the trans QPD signals were doing something bad because their control width had been designed to be slow and slower than the rest of the servo loops.
I switched off the servos, called C1:IOO-TRANS_PIT and C1:IOO-TRANS_YAW and found the MC stayed locked stably with 27000 counts of the transmitted light.
Leaving the trans QPD servos off, I zeroed the offsets and then switched them on. It worked.
The values below are the current offset that I put.
C1:IOO-MC2_TRANS_PIT_OFFSET = -0.115203
C1:IOO-MC2_TRANS_YAW_OFFSET = -0.0323576
|
6425
|
Fri Mar 16 16:01:53 2012 |
rana | Update | Electronics | REFL165 calibration : measurements |
To characterize the RF V to counts we need to know the state of the whitening filter board. Was the filter on or off ? What was the value of the whitening gain slider? |
6424
|
Fri Mar 16 10:37:52 2012 |
Jenne | Update | Electronics | Jenne Laser |
Quote: |
Here is a picture of the small black breadboard on which I have put together the PD characterisation setup. It would be great if we can retain this portable set up as it is, since we keep reusing it every couple of weeks. It would be convenient if we can fiber couple the path to the PD under test with a 2m long fiber. Then we will not have to remove the PD from the optical table while testing it.
|
This is totally sweet Suresh! I don't remember how much more fiber is coiled up under the plate that has the "Jenne Laser" label, but there's a reasonable amount. It's not 2m, but maybe we can just extend the blue snakey thing some? |
6423
|
Fri Mar 16 06:17:56 2012 |
Suresh | Update | Electronics | REFL165 calibration : measurements |
These are the measurements for estimating the amplitude of the signal recorded in the CDS when a known amount of modulated light is incident on the photodiode.
I mounted the PD characterisation setup onto a small breadboard which could then be placed close AP table. I then placed position markers for REFL165 on the AP table before moving it onto my small breadboard. The AM laser was driven by an RF function generator (Fluke 6061A) at a frequency of 165.98866 MHz, which is 102 Hz offset from the 165MHz LO. The power level was set at -45dBm. This power level was chosen since anything higher would have saturated the AntiAliasing Whitening Filters. The counts in the CDS were converted to voltage using the ADC resolution = 20V per 2^16 counts.
|
RF source |
RF power to AM laser |
1611 PD |
1611 PD |
REFL165 |
REFL165 |
CDS |
CDS |
|
power set (dBm) |
Actual power out (dBm) |
DC (V) |
RF out (dBm) |
DC (mV) |
RF out (dBm) |
Amplitude (V) 102 Hz |
Amplitude (V) 102 Hz |
|
|
|
|
|
|
|
|
|
1 |
-45 |
-50.6 |
-2.5 |
-58.9 |
10 |
-37.4 |
0.171 |
0.172 |
2 |
-48 |
-53.5 |
-2.5 |
-62.1 |
10 |
-40.3 |
0.122 |
0.121 |
3 |
-51 |
-56.5 |
-2.5 |
-65.0 |
10 |
-43.1 |
0.085 |
0.085 |
When the 166MHz power is decreased by a factor of 2 the amplitude of 102Hz wave recorded in CDS goes down by sqrt(2) as expected. The RF AM power incident on the REFL165 was estimated to be 0.011mW(rms) (case #1 in the above table) using the DC power ratio and using the transimpedance of the 1611 BBPD to be 700 Ohms. This produces a 171 mV amplitude wave at 102 Hz. I then stepped down the power by factor of 2 and repeated the measurement.
(These numbers however are not agreeing with the power incident on REFL165 if we assume its transimpedance to be 12500. It will take a bit more effort to make all the numbers agree. Will try again tomorrow)
Here is a picture of the small black breadboard on which I have put together the PD characterisation setup. It would be great if we can retain this portable set up as it is, since we keep reusing it every couple of weeks. It would be convenient if we can fiber couple the path to the PD under test with a 2m long fiber. Then we will not have to remove the PD from the optical table while testing it.

|