40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 207 of 341  Not logged in ELOG logo
ID Dateup Author Type Category Subject Text Attachments
  10363   Mon Aug 11 21:03:48 2014 ericq, ranaSummaryIOOMC demod measurementWe measured
the TF of the MC Demod board today. 
  
  10364   Mon Aug 11 22:07:31 2014 KojiSummaryIOOMC demod measurementSCLF-5!? It's surprising as the cut off
of the OLTF is just above 1Hz. cf
this entry
  
  10365   Mon Aug 11 23:32:54 2014 ericqSummaryIOOMC demod measurementHere's the magnitude plot of the board
TF. As mentioned above, this was done with
Marconi+Scope, so we were not able to get
 MCDemod.pdfdemodLP.txt 
  10366   Mon Aug 11 23:50:38 2014 ranaConfigurationWikiDokuWikis are back up

    

       
            
  
  10367   Tue Aug 12 02:09:39 2014 ericqUpdateGeneralReasonable alignment restoredI took over the IFO, after Jenne's locking
efforts, which included manual alignment,
since the ASS was doing bad things. 
  
  10368   Tue Aug 12 13:31:58 2014 JenneUpdatePEMSeismometer cables in place, ready for sensors[TaraV, Jenne]
The short cable from the slab to
the sensor has been assembled and installed
  
  10369   Tue Aug 12 14:29:01 2014 ericqUpdateGeneralReasonable alignment restored

    

       
            
 OLtrend.png 
  10370   Tue Aug 12 18:20:13 2014 ericqUpdateIOOFSS box TFsI made some measurements of the FSS box
today, to have TFs for a loop model, but
also to see what the difference between the
 FSSbox.pdfFSSfilt.pdfFSSdata.zip 
  10371   Tue Aug 12 23:07:24 2014 HarryUpdateGeneralPSL TelescopeI put the PSL telescope in place, and started
coupling to it.
Unfortunately, I was only able to
 PSLTelescopePic.png 
  10372   Wed Aug 13 03:03:37 2014 ericqUpdateGeneralGreen beatnote troubles[Jenne, Rana, ericq]
No luck locking tonight, as spent
a while trying to figure out the complete
  
  10373   Wed Aug 13 10:49:39 2014 HarryUpdateGeneralWeekly Update In the past week, I designed and
assembled coupling telescopes for the PSL
and Y Arm Lasers
  
  10374   Wed Aug 13 10:50:04 2014 AndresUpdateIMCCalculation for the input mode cleaner  Calculation for the input mode
cleaner
I have been working on the
calculation for the input mode cleaner. I
 ModeCleanerSetup0.PNGalaModeModeCleanersolution.png 
  10375   Wed Aug 13 13:08:24 2014 ranaUpdateIMCCalculation for the input mode cleanerCan you please give us some more details
on how this design was decided upon? What
were the design considerations?
  
  10376   Wed Aug 13 16:12:55 2014 HarryUpdateGeneralFOL Layout DiagramPer Q's request, I've made up a diagram
of the complete FOL layout for general reference.
 FOLLayout2.png 
  10377   Wed Aug 13 17:37:43 2014 JenneUpdateGeneralGame plan   2014_Aug_13.pdf 
  10378   Wed Aug 13 19:23:09 2014 JenneUpdateLSCPSL, Aux laser mode hop checkThis afternoon Q helped me put in some
temporary PDs for checking for any mode hopping
behavior in our 3 main lasers. 
 ModeHopCheck_PSL_13Aug2014.pdfModeHopCheck_Xend_13Aug2014.pdfModeHopCheck_Yend_13Aug2014.pdf 
  10379   Wed Aug 13 22:01:57 2014 ranaUpdateIMCCalculation for the input mode cleanerNic,
Andres, and I discussed some more about the
MC WFS project today. We want
  
  10380   Wed Aug 13 23:08:17 2014 ranaUpdateIOOFSS box TFsAs EQ pointed out recently, we're injecting
into the FSS error point just after an RF
pi filter, but before the VGA. We wondered
 FSScomm.pdf 
  10381   Wed Aug 13 23:58:49 2014 ranaHowToComputer Scripts / ProgramsHP8591E spectrum analyzer remote scan

    

       
            
 HP8591E_View.pdf 
  10382   Thu Aug 14 02:51:46 2014 JenneUpdateGeneralGame plan[Jenne, Rana]
* Decided that earlier mode hop scan
won't give us the information that we were
 Y_ALS_FINE_PHASE_OUT_noisy_13Aug2014.pdf 
  10383   Thu Aug 14 14:58:03 2014 JenneUpdateGeneralUpdated game plan   2014_Aug_14.pdf 
  10384   Thu Aug 14 15:10:47 2014 AndresUpdateIMCCalculation for the input mode cleaner

    

       
            
 SolutionForTheModeCleanerSetup00.pngSolutionForTheModeCleanerSetup11.pngPossibleSetupForModeCleaner.PNGalaModeSolution.zip 
  10385   Thu Aug 14 15:42:29 2014 KojiUpdateGeneralUpdated game plan - ALS
End PDH UGF improvement / post mixer
LPF investigation (with in 2 weeks)
  
  10386   Thu Aug 14 15:51:37 2014 JenneUpdateGeneralUpdated game plan

    

       
            
  
  10387   Thu Aug 14 18:02:11 2014 KojiUpdateGeneralUpdated game planGot the idea of ASC.
- Oplevs for PR2, PR3 => PR2 seems
OK. PR3 almost impossible. well
  
  10388   Thu Aug 14 18:05:05 2014 JenneUpdateGeneralUpdated game plan

    

       
            
  
  10389   Thu Aug 14 18:10:46 2014 HarryUpdateGeneralFiber Temperature Effects SetupPurpose
We want to characterize the sort
of response the fibers have to temperature
 tempAffectsSetup.zip 
  10390   Thu Aug 14 18:31:45 2014 ericqUpdateLSCLSC Modeling Update Based on the game plan, I have created
a slew of updated pretty plots about our
signals and loops. 
 7x 
  10391   Thu Aug 14 19:23:25 2014 ranaHowToIOOHow do I set the FSS offset to make the PZT voltage start at the right place? When the IMC locks, we want the FAST
OUT of the TTFSS box to be close to zero
volts. We also want the control signal from
  
  10392   Thu Aug 14 19:33:00 2014 JenneConfigurationIOOMoved MC2 spotLast night, and again just now, I used
the ./MC2_spot_[direction] scripts to center
the MC2 spot on the trans QPD.  The
  
  10393   Thu Aug 14 20:52:36 2014 ranaUpdateWikiViolin Mode table added to WikiMech
Resonance Wiki
I've updated the wiki by trawling
  
  10394   Thu Aug 14 22:16:02 2014 JenneUpdateSUSViolin Mode filters for ETMsThe instigator of this was that we were
seeing ring-ups of ETMs during our ALS locks
this evening.  We measured the ETMY
  
  10395   Thu Aug 14 22:31:12 2014 JenneUpdateLSCTRY gets mystery offsetI don't know why, but TRY has somehow gotten
a 0.3 count offset in the last hour. 
Rana and I are witnesses for each
 TRY_0pt3_offset.pdf 
  10396   Thu Aug 14 22:58:59 2014 rana, jenneSummaryGreen LockingALS DIFF tuning We've been having trouble tuning
the ALS DIFF matrix. Trying to see if the
MC2 EXC can be cancelled in ALS DARM by adjusting
 sweep.pdf 
  10397   Thu Aug 14 23:19:49 2014 ranaSummaryLSCETM Violin fundamental filters moved to LSC We used to do violin mode and test
mass body mode notches in the SUS-LSC filter
modules. Now we want them balanced in the
 01.png03.png 
  10398   Fri Aug 15 01:31:44 2014 JenneUpdateASCPOP QPD to ETMs model wiring completeI have added a few things to the ASS model,
and the ASC sub-block, so that we can send
POP QPD information down to the ETMs for
 ASC_newCARM.pngASSoverview_newCARM.pngASC_screen.png 
  10399   Fri Aug 15 02:05:55 2014 JenneUpdateLSCALS in-loop spectra Not sure why, but Rana and I didn't
see the super high Xarm noise with ALS that
we reported last night (elog
 ALS_XY_inloop_noise_14Aug2014_lowBeatFreq.pdf 
  10400   Fri Aug 15 13:29:31 2014 JenneUpdateGeneralGame plan: 15 Aug   40mToDoList.pdf 
  10401   Fri Aug 15 14:09:21 2014 JenneUpdateLSCTRY mystery offset goneAgain unknown, but about 6 hours ago (so
~8am) the offset disappeared. 
Here's a 1-day trend:
 TRY_0pt3_offset_gone.pdf 
  10402   Fri Aug 15 14:35:57 2014 ericqUpdateLSCTRY mystery offset goneOne question answered, but another raised.
The offset came from LSC-TRY switching to
the ETMY-QPD signal from ETMY-TRY (Hi gain
 TRYmystery.png 
  10403   Fri Aug 15 17:24:44 2014 HarryUpdateGeneralFiber Temp. Earlier today Q and I somewhat resurrected
my old PER measurement setup so I could run
the temperature characterization experiment.
  
  10404   Fri Aug 15 20:26:37 2014 ericqUpdateGeneralGame plan

    

       
            
  
  10405   Fri Aug 15 20:38:17 2014 ericqUpdateGeneralELOG dump A few things that I have neglected
to ELOG yet:

    
    scripts/offsets/LSCoffsets
  
  10406   Mon Aug 18 09:42:50 2014 KojiSummaryIOOMCREFL PD charcterizationRiju did the
measurement of the MCREFL PD.
I found data files in her directory
 MCREFLPD_transimpedance.pdfMCREFLPD_transimpedance_zoom.pdf 
  10407   Mon Aug 18 18:33:57 2014 ericqUpdateGreen LockingYarm Green PDHSo far today, I've been working with the
Y-end green PDH locking. Using a SR560 to
roll off the AG4395A output to take a loop
 yLoop.pdfcrap.pdf 
  10408   Tue Aug 19 01:01:36 2014 Jenne, RanaUpdateGreen LockingYarm Green PDH[ Rana, Jenne]
We remeasured the Yend PDH box.
When we first started, the green
 YPDH_OLG.pdfYPDH_noise.pdf 
  10409   Tue Aug 19 18:32:40 2014 ericqUpdateGreen LockingYarm Green PDHHeading to dinner, going to come back for
more green fun, but here's a quick update:
Xarm Peak-to-Peak of the PDH signal
  
  10410   Tue Aug 19 21:40:44 2014 AndresUpdateIMCNew Optical Setup for the IMCIMC
Calculation and Setup
I have been working in the calculation
 11x 
  10411   Tue Aug 19 23:11:15 2014 JenneUpdateGreen LockingYarm Green PDH 
 Here is a plot of last night's
data with both the control and the error
 ErrAndCtrlSpectra_VoltsPerRtHz.png 
  10412   Wed Aug 20 02:38:41 2014 JenneUpdateGreen LockingYarm Green PDH - requirement

    

       
            
 NoiseConsideration.pdf 
ELOG V3.1.3-