40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 207 of 341  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  12748   Tue Jan 24 01:04:16 2017 gautamSummaryIOOIMC WFS RF power levelsSummary:

I got around to doing this measurement
today, using a minicircuits bi-directional
 MC1_misalignment.png 
  12751   Wed Jan 25 01:27:45 2017 gautamUpdateIMCIMC feedforward checkupThis is probably just a confirmation of
something we discussed a couple of weeks
back, but I wanted to get more familiar with
 IMC_FF_potential.pdf 
  12754   Wed Jan 25 14:30:20 2017 gautamUpdateCDSslow machine bootfest[gautam, lydia]

We rebooted c1psl,
  
  12759   Fri Jan 27 00:14:02 2017 gautamSummaryIOOIMC WFS RF power levelsIt was raised at the Wednesday meeting
that I did not check the RF pickup levels
while measuring the RF error signal levels
  
  12765   Fri Jan 27 20:52:36 2017 gautamUpdateCDStest of new daqd code on fb1I'm not sure if this is related, but
since today morning, I've noticed that
the data concentrator errors have returned.
 DCerrors.png 
  12766   Fri Jan 27 21:21:35 2017 gautamUpdateCDSc1pem revampedThe coil and PD BLRMS are useful tools
in identifying when glitches occur in the
PD  readout, I thought it would be good
  
  12768   Sat Jan 28 01:25:51 2017 gautamUpdateIMC29.5 MHz modulation depth Some more details of our investigation:


Here is a spectrum of the
signal to the power combiner on the PSL table,
 IMC_mod.pdfLockMCNew.png 
  12771   Mon Jan 30 19:07:48 2017 gautamUpdateIMCRF AM stabilization box pulled out[johannes, gautam]

We pulled out the RF AM stabilization
box from the 1X2 rack. PSL shutter was closed,
  
  12775   Tue Jan 31 14:17:48 2017 gautamUpdateIMCRF AM stabilization box pulled out> What
is the probe situation? Ought to use a high
impedance FET probe to measure this or else
  
  12778   Tue Jan 31 18:51:07 2017 gautamUpdateSEISeismic Rainbow Strip - myths debunkedI've been suggesting that there may
be something wonky with the Seismic Rainbow
Striptool on the wall for the last couple
 Seis_BLRMS.png 
  12780   Tue Jan 31 22:07:13 2017 gautamUpdateIMCRF AM stabilization box revampI've added the schematic of the RF
AM stabilization board to the 40m
PSL document tree, after having created
  
  12790   Thu Feb 2 17:43:20 2017 gautamUpdatePEMEM172 mic is hooked up in the PSLI had noticed something wonky with the
microphone, but neglected to elog it. I had
tested it after installation by playing a
 Mic_broken.png 
  12793   Fri Feb 3 00:36:52 2017 gautamUpdateIMCMCL Feedback - framing the problemRana
motivated me to take a step back and reframe
the objectives and approach for this project,
  
  12803   Mon Feb 6 15:18:08 2017 gautamUpdateCDSslow machine bootfestHad to reboot c1psl,
c1susaux, c1auxex, c1auxey 
  
  12804   Mon Feb 6 17:03:41 2017 gautamUpdateIMCMCL Feedback - simulink model updatedI've edited Rana's Simulink model
to reflect the current IMC servo topology
(to the best of my understanding). I've
 mc40_v1.pdf 
  12806   Tue Feb 7 10:18:58 2017 gautamUpdateIMCMC REFL weirdnessA few minutes back, I glanced up at the
control room StripTool and noticed that the
MCREFL PD DC level had gone up from ~0 to
 MCREFLweirdness.png 
  12812   Wed Feb 8 19:13:02 2017 gautamUpdateIMCMCL Feedback - TF measurementsQuick summary elog, details to follow.
I did the following:


Updated the Simulink model
  
  12814   Thu Feb 9 11:22:56 2017 gautamUpdateGeneralSorensens and DIN connections at 1X1I'd like to fix a few things at 1X1
when we plug in the new amplifier for the
29.5MHz modulation signal. 
 Screen_Shot_2017-02-10_at_9.01.46_AM.png 
  12815   Thu Feb 9 23:35:34 2017 gautamUpdateIMCMCL Feedback - TF measurementsHere are the details as promised.

Attachment #1: Updated
simulink model. Since I haven't actually
 mc40_v1.pdfCMboard_OLTF_fit.pdfFSSFast_OLTF_fit.pdfPCdrive_OLTF_measured.pdfdata.zip 
  12816   Fri Feb 10 02:14:10 2017 gautamUpdateIMC29.5 MHz stabilizer box replacementLydia finished up installing the new RF
amplifier, and will elog the details of the
installation.
  
  12820   Fri Feb 10 18:21:21 2017 gautamUpdateIMCIMC Demod boardRana and I spent some time looking at the
IMC demod board earlier today. I will post
the details shortly, but there was a label
  
  12822   Sun Feb 12 01:16:57 2017 gautamUpdateIMCIMC length loop - summary of changes29.5 MHz RF Modulation Source


 DemodBoardOrthogonality.pdfIMC_PDH.pdfTEK00001.PNGIMC_OLTF.pdfFSS_gain_comparison.pdf 
  12824   Mon Feb 13 13:34:44 2017 gautamUpdateIMCIMC length loop - bad SMA cable replacedI was a little confused why the In1 Gain
had to be as high as +10dB - before the changes
to the RF chain, we were using +27dB, and
 noisy_PMC_REFL.png 
  12828   Tue Feb 14 10:43:06 2017 gautamBureaucracyEquipment loanEquipment to Cryo LabPZT   
  12833   Wed Feb 15 23:54:13 2017 gautamUpdateIMCIMC saga continues...Following
the discussion at the meeting today, I wanted
to finish up the WFS tuning and then hand
 MCstrip.pngIMCweirdness.png 
  12834   Thu Feb 16 13:29:38 2017 gautamSummaryGeneralAlternative Calibration SchemeSummary:

Craig and I have been trying to
put together a Simulink diagram of the proposed
 AltCal.pdf 
  12838   Fri Feb 17 20:10:18 2017 gautamUpdateIMCWFS servos turned back on[Koji, gautam]

Turns
out the "problem" with WFS2 and
  
  12840   Sat Feb 18 21:50:48 2017 gautamUpdateIMCWFS servos turned back onHere is a comparison  WFS_error_noise.pdf 
  12847   Thu Feb 23 10:59:53 2017 gautamUpdateCOCRC folding mirrors - coating optimizationI've now made
 PR3_R_170222_2006.pdfPR3_123_TOnoise_170222_2203.pdfPR3_123_Layers_170222_2203.pdfPR3AR_R_170222_2258.pdfPR3AR_123_Layers_170222_2258.pdf 
  12859   Wed Mar 1 16:00:41 2017 gautamUpdateComputer Scripts / ProgramsMatlab R2016b installedSince it would be nice to have the latest
version of Matlab, with all its swanky new
features (?), available on the control room
  
  12862   Wed Mar 1 23:56:09 2017 gautamUpdateIMCFront panel for 29.5 MHz amplifier boxThe
alignment wasn't disturbed for the photo-taking
- I just re-checked that the spot is indeed
  
  12867   Sun Mar 5 12:41:23 2017 gautamUpdateIMCWFS servo-steppinI've been sitting on some data for
a while now which I finally got around to
plotting. Here is a quick summary:
 WFS_stepping.pngWFS_comparisons.pdfWFSdigitalAA.pdf 
  12870   Mon Mar 6 14:47:49 2017 gautamUpdateSummary PagesCode status check script modifiedFor a few days now, the "code status"
page
has been telling us that the summary pages
  
  12880   Fri Mar 10 11:37:25 2017 gautamUpdateComputer Scripts / Programsloss scriptThis was still running at ~9.30am today
morning, at which point I manually terminated
it after confirming with Johannes that it
  
  12887   Tue Mar 14 10:56:33 2017 gautamUpdateCOCRC folding mirrors - coating optimizationRana suggested including some additional
terms to the cost function to penalize high
sensitivity to deviations in the layer thickness
 PR3_R_170313_1701.pdfPR3AR_123_Layers_170313_1701.pdfPR3AR_R_170313_1752.pdfPR3AR_123_Layers_170313_1752.pdf 
  12891   Fri Mar 17 14:49:09 2017 gautamUpdateLSCMCREFL condition picturesI did a quick measurement of the beam size
on the MC REFL PD today morning. I disabled
the MC autolocker while this measurement
 IMG_7219.JPGMCREFL_X.pdfMCREFL_Y.pdf 
  12893   Mon Mar 20 11:18:58 2017 gautamUpdateCDSNo internet connectivity on control room machinesThere
is no internet connectivity on any of the
  
  12894   Mon Mar 20 14:39:44 2017 gautamUpdateCDSNo internet connectivity on control room machinesKoji
diagnosed that the NAT router was to blame
  
  12896   Tue Mar 21 15:13:44 2017 gautamUpdateIMCIMC input beam mode matching[valera, gautam]

Last night, Valera and I looked
into two aspects of the IMC:
 IMG_7220.JPGIMC_ModeMatch.pdfsingleLensSensitivity.pdfsensitivity.pdfIMCmodeMatch.m 
  12897   Tue Mar 21 21:21:58 2017 gautamUpdateIOOWFS filter banks updatedThe arrangement of filters in the WFS loop
filter banks have been altered, Rana will
update with details of the motivation behind
 MCWFS_screen.png 
  12898   Tue Mar 21 21:59:48 2017 gautamUpdateIMCIMC input beam mode matching[valera, gautam]

We implemented the plan outlined
in the previous elog. The visibility (Pmax-Pmin)/(Pmax+Pmin) calculated
 IMG_3654.JPGIMG_3655.JPG 
  12899   Wed Mar 22 00:33:00 2017 gautamUpdateIMCIMC length offset nulling[valera, gautam]

Motivation: see this
elog
 offsetInvestigation.pdfoffset_summing_amp.pdf 
  12900   Wed Mar 22 16:58:25 2017 gautamUpdateIMCWFS sensing matrix measurementsI've taken a bunch of transfer function
measurements from the MC ASC PIT and YAW
channels to the WFS error signals using the
  
  12901   Thu Mar 23 01:44:53 2017 gautamUpdateIMCWFS sensing matrix measurementsThanks to Koji's nice MATLAB script
using DttData functions, I was able to quickly
analyze the TF data. Essentially, this measurement
 IMC_WFS_segment_TF.pdfIMC_WFS_channels_TF.pdfTFsummary.pdfIMC_WFS_170322.xlsx.zip 
  12903   Thu Mar 23 23:38:58 2017 gautamUpdateIMCMC SUS damping gains stepped downI've reduced the gains of the damping
on all 3 MC SUS by a factor of 3 for overnight
observation as part of the ongoing feedforward
  
  12904   Fri Mar 24 11:26:57 2017 gautamUpdateIMCMC SUS damping gains restoredI've restored the damping loop gains
to their nominal values. Analysis of the
coherence between MCL and seismometer channels
  
  12905   Fri Mar 24 12:21:27 2017 gautamSummaryIOOMCL / MCF / CalibrationI repeated this measurement as follows:


Added a filter in the MC_F
filterbank (FM9) to account for the Pomona
 6x 
  12906   Fri Mar 24 19:04:18 2017 gautamUpdateIMCSeismic feedforward and WFS[valera, gautam]

On Wednesday at the meeting, we
were discussing why we aren't able to
 MCL_comparison.pdfseis_comparison.pdf 
  12916   Wed Mar 29 11:41:19 2017 gautamUpdatePSLPMC DAQ assay for feed-forward integrationThe C1IOO frontend machine that resides
in 1X1/1X2 has 2 ADCs, ADC0 and ADC1. The
latter has 28 out of 32 channels unused at
 C1ALS_PSLnamespace.pngPMCcheckout.pdfD980352-A-40m_151119.pdf 
  12918   Thu Mar 30 00:16:09 2017 gautamUpdatePSLPSL NPRO PZT calibrationAs part of the ongoing effort to try and
calibrate the PMC DAQ channels into physical
units, I tried to get a calibration for the
  
ELOG V3.1.3-